• Title/Summary/Keyword: 심전도 생체인식

Search Result 33, Processing Time 0.03 seconds

ECG-based Biometric Authentication Using Random Forest (랜덤 포레스트를 이용한 심전도 기반 생체 인증)

  • Kim, JeongKyun;Lee, Kang Bok;Hong, Sang Gi
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.6
    • /
    • pp.100-105
    • /
    • 2017
  • This work presents an ECG biometric recognition system for the purpose of biometric authentication. ECG biometric approaches are divided into two major categories, fiducial-based and non-fiducial-based methods. This paper proposes a new non-fiducial framework using discrete cosine transform and a Random Forest classifier. When using DCT, most of the signal information tends to be concentrated in a few low-frequency components. In order to apply feature vector of Random Forest, DCT feature vectors of ECG heartbeats are constructed by using the first 40 DCT coefficients. RF is based on the computation of a large number of decision trees. It is relatively fast, robust and inherently suitable for multi-class problems. Furthermore, it trade-off threshold between admission and rejection of ID inside RF classifier. As a result, proposed method offers 99.9% recognition rates when tested on MIT-BIH NSRDB.

A Research Trend Study on Bio-Signal Processing using Attention Mechanism (어텐션 메카니즘을 이용한 생체신호처리 연구 동향 분석)

  • Yeong-Hyeon Byeon;Keun-Chang Kwak
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2023.05a
    • /
    • pp.630-632
    • /
    • 2023
  • 어텐션 메커니즘은 딥 뉴럴네트워크에 결합하여 언어 생성 모델에서 성능을 개선하였고, 이러한 성공은 다양한 신호처리 분야에 응용 및 확장되고 있다. 특정 입력 신호 부분에 선택적으로 집중함으로써, 어텐션 모델은 음성 인식, 이미지와 비디오 처리, 그리고 생체인식 등의 분야에서 더 높은 성능을 보여주고 있다. 어텐션 기반 모델은 심전도 신호를 이용한 개인식별 및 부정맥검출, 뇌파도 신호를 이용한 발작유형분류 및 수면 단계 분류, 근전도 신호를 이용한 제스처 인식 등에 사용되고 있다. 어텐션 메커니즘은 딥 뉴럴네트워크의 해석 가능성과 설명 가능성을 향상시키기 위해 사용되기도 한다. 신호 처리 분야에서의 어텐션 모델 연구는 지속적으로 진행 중이며, 다른 분야에서의 잠재력 탐구에 대한 관심이 높아지고 있다. 따라서 본 논문은 어텐션 메카니즘을 이용한 생체신호처리 연구 동향 분석을 수행한다.

Research on the Emotion Recognition System based on Electrocardiograph and Pulse Signals (심전도 및 맥파신호 기반의 감정인식 시스템에 관한 연구)

  • Hong, Yoon-Jung;Hwang, Yun-Kyung;Shin, Dong-Kyoo;Kim, Dong-Hyun;Shin, Dong-Il
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2008.05a
    • /
    • pp.175-178
    • /
    • 2008
  • 본 논문은 생체 신호들 중 데이터 획득이 간편한 심전도와 맥파를 실시간으로 취득하여 기계학습 기법인 SVM (Support Vector Machine)알고리즘과 클러스터링 기법인 k-NN (Nearest Neighbor)알고리즘을 적용한 인간의 감정을 분석하는 시스템에 대한 연구결과를 제시한다.

ZigBee를 이용한 생체신호 전송 및 관리시스템

  • Kim, Hyun-Gyu;Kim, Hye-Jung;Lee, Seung-Jae
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2005.07a
    • /
    • pp.526-528
    • /
    • 2005
  • 헬스 산업에 대한 요구와 관심이 점차 사회적으로 증가하고 있으며, 이를 위한 서비스 모델과 시스템에 대한 필요성이 인식되고 있다. 본 논문에서는 혈당, 심전도와 같은 만성질환자의 생체정보를 측정하고 ZigBee기반의 무선모듈을 통해 헬스센터 서버에 전송함으로써 실내외 환경에서 이용 가능한 생체신호 전송 및 관리 시스템의 설계 및 구현에 대해 기술하고자 한다.

  • PDF

텔레바이오인식기반 비대면 인증기술 표준화 동향

  • Kim, Jason;Lee, Sung Jae;Kim, Byoungsub;Lee, Sang-Woo
    • Review of KIISC
    • /
    • v.25 no.4
    • /
    • pp.43-50
    • /
    • 2015
  • 바이오인식기술은 사람의 지문 얼굴 홍채 정맥 등 신체적 특징(Physiological characteristics) 또는 음성 서명 자판 걸음걸이 등 행동적 특징(Behavioral characteristics)을 자동화된 IT 기술로 추출 저장하여 다양한 IT 기기로 개인의 신원을 확인하는 사용자 인증기술이다. 2001년 미국의 911 테러사건으로 인하여 전 세계 국제공항 항만 국경에서 지문 얼굴 홍채 등 바이오정보를 이용한 출입국심사가 보편화됨과 동시에 ISO/IEC JTC1 SC37(바이오인식) 국제표준화기구를 중심으로 표준화가 급속도로 진행되어 왔다. 최근 들어 스마트폰 테블릿 PC 등 모바일기기에 지문 얼굴 등 바이오정보를 탑재하여 다양한 모바일 응용서비스를 가능하게 해주는 모바일 바이오인식 응용기술이 전 세계적으로 개발 보급되고, 삼성전자 페이팔 중심으로 바이오인식기술을 이용한 모바일 지급결제솔루션에 대한 사실표준화협의체인 FIDO, ITU-T SG17 Q9(텔레바이오인식) 국제표준화기구를 중심으로 표준화가 진행되고 있다. 특히 이러한 모바일 바이오인식기술은 스마트폰을 통한 비대면 인증기술 수단으로서 핀테크의 중요한 요소기술로 작용될 전망이다. 한편, 위조지문 등 전통적인 바이오인식 기술의 위변조 위협으로 인한 우려도 증폭됨에 따라 스마트워치 등 웨어러블 디바이스에서 살아있는 사람의 심박수(심전도), 뇌파 등의 생체신호를 측정하여 스마트폰을 통하여 개인을 식별하는 차세대 바이오인식기술로 진화중에 있다. 본고에서는 바이오인식기술의 변천사와 함께 국내외 모바일 바이오인식기술 동향과 표준화 추진현황을 살펴보고, 지난 2015년 5월 29일 발족한 KISA "모바일 생체신호 인증기술 표준연구회"를 통하여 뇌파 심전도 등생체신호를 이용한 차세대 바이오인식 기술 및 표준화 계획을 수립하여 향후 바이오인식기반의 비대면 인증기술에 대한 추진전략을 모색하고자 한다.

A Study of ECG Pattern Classification of Using Syntactic Pattern Recognition (신택틱 패턴 인식 알고리즘에 의한 심전도 신호의 패턴 분류에 관한 연구)

  • 남승우;이명호
    • Journal of Biomedical Engineering Research
    • /
    • v.12 no.4
    • /
    • pp.267-276
    • /
    • 1991
  • This paper describes syntactic pattern recognition algorithm for pattern recognition and diagnostic parameter extraction of ECG signal. ECG signal which is represented linguistic string is evaluated by pattern grammar and its interpreter-LALR(1) parser for pattern recognition. The proposed pattern grammar performs syntactic analysis and semantic evaluation simultaneously. The performance of proposed algorithm has been evaluated using CSE database.

  • PDF

A Study on Ubiquitous Psychological State Recognition Model Using Bio-Signals (생체정보를 이용한 유비쿼터스 심리상태 인식 모델 연구)

  • Chon, Ki-Hwan;Choi, Hyung-Jin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.2B
    • /
    • pp.232-243
    • /
    • 2010
  • In this paper, various physiological signals of humans were measured and analyzed to inference their psychological state and biological information, and Bio-Signal Context aware system (BSC), which recognizes the current context of its users as well as the information of exterior environment and offers the service appropriate for them, was designed and implemented. The BSC extracts and analyzes the features from bio-signals, such as the measured electroencephalogram (EEG), electrocardiogram (ECG), and galvanic skin response (GSR), with its different sensors, has the input of the analyzed results, and discriminates four psychological states of rest, concentration, tension and melancholy. In addition to the results of the discriminated psychological states, the information of biological condition analyzed from the user's bio-signals, for example, heart rate variability (HRV), Galvanic skin response (GSR) and body temperature, and the information of external environment related to the user's are collected to offer the service fit for the user's present biological condition by inferring and recognizing the user's present situation.

A Study on the Synthetic ECG Generation for User Recognition (사용자 인식을 위한 가상 심전도 신호 생성 기술에 관한 연구)

  • Kim, Min Gu;Kim, Jin Su;Pan, Sung Bum
    • Smart Media Journal
    • /
    • v.8 no.4
    • /
    • pp.33-37
    • /
    • 2019
  • Because the ECG signals are time-series data acquired as time elapses, it is important to obtain comparative data the same in size as the enrolled data every time. This paper suggests a network model of GAN (Generative Adversarial Networks) based on an auxiliary classifier to generate synthetic ECG signals which may address the different data size issues. The Cosine similarity and Cross-correlation are used to examine the similarity of synthetic ECG signals. The analysis shows that the Average Cosine similarity was 0.991 and the Average Euclidean distance similarity based on cross-correlation was 0.25: such results indicate that data size difference issue can be resolved while the generated synthetic ECG signals, similar to real ECG signals, can create synthetic data even when the registered data are not the same as the comparative data in size.

ITU-T SG17 텔레바이오인식 국제표준화 현황

  • Lee, Saewoom;Kim, Jason
    • Review of KIISC
    • /
    • v.28 no.4
    • /
    • pp.18-24
    • /
    • 2018
  • 전통적으로 바이오인식기술은 출입국심사, 출입통제 행정, 사회복지, 의료, 금융 등 다방면에서 폭넓게 보급되어 실생활에서 널리 활용되고 있다. 최근 들어, 모바일 지급결제서비스 ATM 인출기 인터넷전문은행 등과 같은 핀테크 분야에서 비대면 인증기술로 바이오인식기술이 각광을 받기 시작했다. 그러나 지문 얼굴 홍채 정맥 등 기존의 신체적 특징을 이용한 바이오인식기술은 가짜지문 등 신체적 특징을 이용한 바이오인식기술의 위변조 위협에 대한 우려가 존재하여 심전도 등 생체신호, 걸음걸이와 같이 살아있는 사람의 행동학적 특징을 이용한 차세대 바이오인식기술에 박차를 가하고 있는 추세이다. 이에 본 논문에서는 바이오인식 표준화를 위한 ITU-T SG17 Q9 국제표준화기구를 소개하고, X.tab 국제표준화 현황에 대하여 집중적으로 살펴보고자 한다.

Development of Electrocardiogram Identification Algorithm for a Biometric System (생체 인식 시스템을 위한 심전도 개인인식 알고리즘 개발)

  • Lee, Sang-Joon;Kim, Jin-Kwon;Lee, Young-Bum;Lee, Myoung-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.5
    • /
    • pp.365-374
    • /
    • 2010
  • This paper is about the personal identification algorithm using an ECG that has been studied by a few researchers recently. Previously published algorithm can be classified as two methods. One is the method that analyzes ECG features and the other is the morphological analysis of ECG. The main characteristic of proposed algorithm uses together two methods. The algorithm consists of training and testing procedures. In training procedure, the features of all recognition objects' ECG were extracted and the PCA was performed for morphological analysis of ECG. In testing procedure, 6 candidate ECG's were chosen by morphological analysis and then the analysis of features among candidate ECG's was performed for final recognition. We choose 18 ECG files from MIT-BIH Normal Sinus Rhythm Database for estimating algorithm performance. The algorithm extracts 100 heartbeats from each ECG file, and use 40 heartbeats for training and 60 heartbeats for testing. The proposed algorithm shows clearly superior performance in all ECG data, amounting to 90.96% heartbeat recognition rate and 100% ECG recognition rate.