• Title/Summary/Keyword: 심장 판막, 기계

Search Result 127, Processing Time 0.026 seconds

Twenty-year Experience of Mitral Valve Replacement with the St. Jude Medical Mechanical Valve Prosthesis (St. Jude 기계 판막을 이용한 승모판막 치환술의 20년 장기성적)

  • Seo Yeon-Ho;Kim Kong-Soo;Jo Jung-Ku
    • Journal of Chest Surgery
    • /
    • v.39 no.7 s.264
    • /
    • pp.527-533
    • /
    • 2006
  • Background: A retrospective study was conducted to analyze the results of St. Jude Medical mitral valve replacement at the Chonbuk National University Hospital since the initial implant in May 1984. Material and Method: Between May of 1984 and December of 1996, 95 patients underwent MVR with the St. Jude Medical mechanical valve prosthesis at Department of Medical Science of Chonbuk National University Hospital and follow-up ended in May of 2004. Result: Age ranged from 19 to 69 years. Follow-up (mean${\pm}$standard deviation) averaged $10.6{\pm}4.2\;year$. Thirty-day operative mortality was 4.2% (4/95). Nine late deaths have occurred and actuarial survival was $90.5{\pm}3.0%,\;87.9{\pm}3.4%\;and\;83.2{\pm}4.6%$ at 5, 10 and 20 years, respectively. Probability of freedom from valve-rotated death was $95.5{\pm}2.1%,\;94.3{\pm}2.4%\;and\;91.0{\pm}3.9%$ at 5, 10 and 20 years, respectively. Seven patients have sustained thromboembolic events (1,05%/patient-year). Fifteen patients had anticoagulation related hemorrhage (3.56%/patient-year). There was no structural valve deterioration. Probability of freedom from all complications was $82.0{\pm}3.9%,\;71.3{\pm}4.8%\;and\;42.4{\pm}10.5%$ at 5, 10 and 20 years, respectively. Conclusion: We confirm the effective and excellent durability of the St. Jude Medical prosthesis in the mitral position with a low event rate at long-term follow-up. It also demonstrates the commonly encountered practical difficulty of adjusting the anti-coagulation protocol in patients with prosthetic mitral valves.

Long Term Clinical Results of Duromedics Valve (Duromedics 판막의 장기 임상 성적 고찰)

  • Jeong, Dong-Seop;Lim, Chung;Kim, Kyung-Hwan;Kim, Ki-Bong;Aun, Hyuk
    • Journal of Chest Surgery
    • /
    • v.34 no.9
    • /
    • pp.686-691
    • /
    • 2001
  • Background: The Duromedics valve has been used in Korea since 1982, however, but there were no long term clinical results that have been reported. This paper presents the long term clinical results of Duromedics valve implanted in Seoul National University Hospital. Material and method: Between 1987, 23 patients underwnet cardiac valve replacement with Duromedics mechanical valve. There were 8 mitral valve replacements, 5 aortic valve replacements, one tricuspid valve replacement, 6 aortic and mitral valve replacements, and one mitral and tricuspid valve replacement. There were 12 men and 11 women. The mean age was 35$\pm$10(15~52) years. We evaluated the clinical performance of Duromedics cardiac prosthesis. Result: The early operative mortality was 4.3%(1/23) and the late morlatity was 4.3%(1/23). Causes of death were low cardiac output syndrome and structural valvular failure. The mean follow-up duration was 133$\pm$43(8~157) months. There were 3 reoperations. The causes of reoperations were thrombosis and structural failure and nonstructural valvular failure. The actuarial survival rate at 10 years was 90.9%. Conclusion: Although the number of patients was not sufficient for effective clinical study, the long term clinical results of Duromedics valve was relatively good and there was no structural defect in this mechanical valve. However, more research is needed in the future.

  • PDF

Long Term Experience of Mitral Valve Replacement (승모판치환수술의 장기 임상성적)

  • 조용길;류지윤
    • Journal of Chest Surgery
    • /
    • v.29 no.10
    • /
    • pp.1102-1110
    • /
    • 1996
  • Between Oct. 1985 and July 1995, 230 patients underwent mitral valve replacement. There were 77 men and 153 women whose mean age was 35.7 years, range 9 to 62 The concomitant operations were 40 aortic valve replacements(17.4%), 25 tricuspid annuloplasties(10.4%), 8 aortic valve replacements & tricuspid annuloplasties(3.5%), 2 tricuspid valve replacements(0.9%) and others, We used 139 mechanical (76 51. Jude medical, 33 CarboMedics, 30 Sorin) and 91 tissue 386 Carpentier-Edwards, 5 lonescu-Shiley) valves. The early postoperative complications occurred in 28 cases. There were 8 low cardiac output syndrome, 5 pleural effusion, 3 significant arrhythmia, 2 cardiac rupture and others. There were 6 early hospital deaths (2.6%) due to low cardiac output syndrome(2), arrhythmia(2) and ventricul r rupture(2). The cuAmulative notal follow-up period was 764. 4 patient-years with a mean of 4).9 months. The long term follow-up information was available for 212 patients(94.6%). There were 21 cases of valve-related complications. Prosthetic valve failure(10), anti-coagulation related bleeding (5), prosthetic valve endocarditis (4), and thromboembolism (2) occurred at rates of 1.3, 0.7, 0.5, and 0.3%Ipt-yr respectively. Late death occurred In 5 cases (0.7%/pt-yr) associated with prosthetic valve endocarditis (2), heart failure (2) and anti-coagulation related bleeding (1). There was no difference in the rate of freedom from prosthetic valve failure between the mechanical and tissue valve group at 6 years (100%), but there was significant difference at 9 years between the tissue (34.4%) and mechanical valve (100%) group (p=0.032). Actuarial survival rates were 98. 8% in tissue valve. 9).7% in mechanical valve group and 96.6% in total patients at 9 years.

  • PDF

Postoperative Echocardiographic Hemodynamic Comparison between Recently Available Bileaflet Mechanical Valves (수종의 기계판막치환후 초음파심음향도를 이용한 판막간의 혈류역학적 비교)

  • Kang Joon Kyu;Hong Joon Hwa;Kim Hyung Tai;Park In Duk;Lee Cheol Joo
    • Journal of Chest Surgery
    • /
    • v.38 no.7 s.252
    • /
    • pp.496-500
    • /
    • 2005
  • There was no difference between the bileaflet mechanical valves on the midterm and longterm clinical outcome. We reviewed the hemodynamic comparison between recently available mechanical valves by Doppler Echocardiography. Material and Method: We retrospectively reviewed 396 postoperative hemodynamic datas (EOA, MDPG, and MSPG) by doppler echocardiography in 345 patients. Mechanical valves from 5 venders (Sorin Bicarbon, SJM, ATS, On-X, and Edward MIRA) were compared. There were 232 valves in mitral position, 162 in aortic, and 2 in tricuspid. Result: There were 178 men (mean age; $50.6\pm13.9$ years old) and 167 women $(52.6\pm,4.6)$. MDPG/EOA of 27 mm in mitral position was Sorin; $4.2\pm1.5 mmHg/3.0\pm0.9cm^2,\;SJM;\;2.3\pm1.2/3.5\pm0.6$. In 29mm, Sorin, SJM, ATS, On-X, MIRA revealed $3.4\pm1.2/3.1\pm0.6,\;3.3\pm1.1/2.7\pm0.4,\;3.8\pm0.8/3.2\pm0.6,\;4.0\pm3.0/3.1\pm0.9,\;2.9\pm0.9/3.0\pm0.8$ In 31mm, Sorin, SJM, ATS, MIRA revealed $3.9\pm1.9/2.9\pm0.6,\;3.5\pm1.2/3.0\pm0.6,\;3.4\pm0.8/2.8\pm0.2,\;3.7\pm1.5/2.7\pm0.7$. In 33mm, Sorin, SJM, MIRA revealed $4.4\pm0.9/2.5\pm0.4,\;3.4\pm1.5/3.3\pm0.5,\;4.7\pm2.4\3.0\pm0.3$. MSPG/EOA of 19mm aortic position was Sorin, SJM, ATS, On-X, MIRA $18.0 mmHg/1.2cm^2,\;25.6\pm8.7/1.1\pm0.3,\;25.9\pm12.6/1.2\pm0.3,\;23.0/1.3,\;27.9\pm7.1/1.2\pm0.1$ in that order. In 21mm, SJM, ATS, On-X, MIRA revealed $18.3\pm6.7/1.5\pm0.5,\;13.7\pm2.1/1.7\pm0.3,\;17.0/1.4,\;17.1\pm5.5/1.8\pm0.5$. In 23mm Sorin, SJM, ATS, On-X, MIRA revealed $14.0\pm4.6/1.7\pm0.6,\;12.8\pm3.2/2.0\pm0.2,\;16.8\pm12.2/2.1\pm0.9,\;14.0/1.5,\;15.0\pm5.5/1,8\pm0.5$. In 25mm, SJM and MIRA revealed $14.0\pm5.1/1.8\pm1.0,\;11.0/2.3$. There was no statistically significant difference in these values between the venders given the same position and size. 2 redo valve replacements were performed, 1 due to severe hemolysis in ATS and 1 due to leaflet immobilization in SJM. Conclusion: Postoperative hemodynamic comparison by doppler echocardiography shows no statistically significant difference between recently available mechanical valves in this country.

Long Term Results of Carbomedics Mechanical Valve (Carbomedics 기계판막 치환환자의 장기성적)

  • 김병열;임용택;정승혁;강경훈;이정호
    • Journal of Chest Surgery
    • /
    • v.33 no.7
    • /
    • pp.552-559
    • /
    • 2000
  • Background; The aim of this study is to evaluate our clinical experience with the Carbomedics heart valve prosthesis. Material and Method; Between Aug. 1988 and Dec. 1998, 294 Carbomidics valves were implanted in 235 patients(mitral; 143, mitral and aortic; 59, aortic; 33) The mean age at operation is 40.0$\pm$12.3 years(range 7 to 68 years); 63.8% (150patients) were woman. Follow up was 97.4% complete and mean follow up time was 5.7years with a total of 1209.2 patient-years. Result; The hospital mortality was 8.9%(mitral; was 95.2$\pm$1.6%(mitral ; 94.9$\pm$2.1%, mitral and aortic 95.0$\pm$3.7%, aortic 96.2$\pm$3.8%). Actual freedom rates from complications(linearized rates in parentheses) were fllowings; thromboembolism 96.2$\pm$1.5%(0.59%pt-yr), valve thrombosis 96.7$\pm$1.4%(0.5%/pt/yr), anticoagulant related hemorrhage 98.3$\pm$1.0%(0.25%/pt-yr), perivalvular leak 99.0$\pm$1.4%(0.5%/pt-yr), endocarditis 98.7$\pm$1.0%(0.25%/pt-yr), perivalvular leak 99.0$\pm$0.7%(0.17%pt-yr), endocarditis 98.7$\pm$1.0%(0.17%$\pm$pt-yr) and overall valve-related complications 88.9$\pm$2.5%(1.68%/pt-yr). Conclusion; The clinical performance of the Carbomedics valve was quite satisfactory with a low incidence of valve related mortality and morbidity.

  • PDF

Trido Mitral Valve Replacement with Dacron Collar Prosthetic Valve due to Paravalvular Leak (판막주위 누출에 대한 다크론 확장 인공판막을 이용한 판막치환술 치험)

  • 배윤숙;정성철;김우식;정승혁;이정호;김병열
    • Journal of Chest Surgery
    • /
    • v.35 no.11
    • /
    • pp.822-825
    • /
    • 2002
  • The paravalvular leak after redo mitral prosthetic valve replacement is rare but serious complication when it does happen. This condition should be corrected surgically to increase life span and improve symptoms. But simple closure or patch closure of paravalvular leak are not effective in cases of weak annulus or broad defect. We report 3 cases of trido mitral valve replacement using mechanical valve with its sewing ring expanded by a collar of Dacron sheet. The prosthetic sewing ring is anchored on the weak mitral annulus with multiple interrupted sutures, while the Dacron collar is contineuously sutured to the left atrial wall for blood tight sealing. All of the three cases showed event free postoperative course.

A Numerical Analysis on the Motion of Mechanical Heart Valve(MHV) and Characteristics of Blood Flow in an Elastic Blood Vessel (탄성혈관 내 기계식 인공심장판막(MHV)의 거동 및 혈액 유동 특성에 관한 수치해석적 연구)

  • Bang Jin-Seok;Choi Choeng-Ryul;Kim Chang-Nyung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.3 s.168
    • /
    • pp.154-161
    • /
    • 2005
  • In this study, the leaflet motion of a mechanical heart valve and the characteristics of two-dimensional transient blood flow in an elastic blood vessel have been numerically investigated by using fluid-structure interaction method. Here, blood has been assumed as a Newtonian, incompressible fluid. Pressure profiles have been used as boundary conditions at the ventricle and the aorta. As a result, closing motion of the leaflet is faster than opening one. While opening angles of leaflet grow up, vortex is detected at the sinus and backward of the leaflets. When the leaflet is fully closed, vortex is detected at the ventricle and at that moment maximum displacement of the elastic blood vessel is observed in the vicinity of the sinus region. Maximum displacement is caused in association with the blood flow that is oriented toward the elastic blood vessel.

Surgical Management of Aortic Valve Injury after Nonpenetrating Trauma (외상성 대동맥 판막 손상의 수술적 처치)

  • Seo, Yeon-Ho;Kim, Kong-Soo;Kim, Jong-Hun
    • Journal of Chest Surgery
    • /
    • v.40 no.3 s.272
    • /
    • pp.232-235
    • /
    • 2007
  • We present 2 cases of patients who underwent surgical repair and replacement of an injured aortic valve that was secondary to nonpenetrating trauma. Primary repair was undertaken on an 18-year old boy, but he had persistent moderate aortic regurgitation for five years after surgery. Another 64-year old man was treated successfully with surgical replacement of the aortic valve via employing a prosthetic mechanical valve. Attempts at valvuloplasty for the treatment of traumatic aortic valve injury have not been uniformly successful, and prosthetic valve replacement is recommended for repair, except for highly selected cases.

Redo Konno Procedure - A case report - (Konno씨 수술 재수술 -1례 보고-)

  • 구관우;강신광;원태의;김시욱;박상순
    • Journal of Chest Surgery
    • /
    • v.35 no.2
    • /
    • pp.133-136
    • /
    • 2002
  • A 28 year-old male who had received Konno procedure twelve years ago with 23mmmechanical aortic valve and bovine pericardium with which his small aortic annulus, ventricular septum and right ventricular outflow tract had been enlarged was transferred due to sudden congestive heart failure. There were perforations on aortic and interventricular portion of bovine pericardial patch above and below the aortic valve, respectively, which was calcified and denaturated severely. The perforations seemed to be attributed to the cracks, resulting from mobility of mechanical aortic valvc itself and stiffness of calcified and denaturated bovine patch. We performed a redo Konno procedure applying PTFE patch.

Short Term Clinical Experiences of 52 Sorin Bicarbon Mechanical Valves (Sorin Bicarbon 기계판막의 단기 임상성적)

  • Lee, Cheol-Joo;Choi, Ho;Kim, Jung-Tai;Soh, Dong-Moon;Roh, Hwan-Kyu;Han, Jeong-Seon
    • Journal of Chest Surgery
    • /
    • v.31 no.7
    • /
    • pp.679-683
    • /
    • 1998
  • From June 1995 to May 1997, we have implanted 52 Sorin Bicarbon mechanical valves in 41 patients. They were 16 men and 25 women, and their mean age was 47.4${\pm}$14.8(range; 18∼74 y.o.). 35(27 mm∼31 mm) were in mitral position, 15(19 mm∼25 mm) in aortic position, and 2(31 mm) in tricuspid position. 3 CABGs and a tumor excision were taken concomittantly. 35 patients were primary operation, and 6 were re-do operations. By intraoperative transesophageal doppler echocardiography, transvalvular peak/mean pressure gradient was 6.1${\pm}$2.7/2.4${\pm}$1.4 mmHg in mitral position and 27.6/10.7 mmHg in aortic position. The effective valve opening area in mitral position was 3.2${\pm}$0.6 cm2. Follow-up was total 508.6 patient-months, and mean follw-up was 12.7${\pm}$9.2 months. NYHA class was improved from 2.6${\pm}$0.6 to 1.2${\pm}$0.3 in average postoperatively. During that period, there was no operative death. 2 late non-valve related deaths were occurred. One was died of COPD, and the other was possible acute myocardial infarction. Among 7 postoperative complications, one valve related complication(minimal paravalvular leakage) was noticed. In conclusion, Sorin Bicarbon mechanical valve is believed one of the safe choice in clinical settings. It showed excellent hemodynamic and mechanical functions, and very low postoperative valve related complications in short term clinical experience.

  • PDF