• Title/Summary/Keyword: 심장판막질환

Search Result 227, Processing Time 0.037 seconds

Valve Replacement in an Anuric Patient with Chronic Renal Failure - 1 Case Report - (만성 신부전으로 인한 무뇨증 환자에서의 판막치환술 - 1례 보고 -)

  • Kim, Si-Hoon;Kwack, Moon-Sub;Lee, Sun-Hee;Park, Jae-Kil;Jin, Ung
    • Journal of Chest Surgery
    • /
    • v.32 no.6
    • /
    • pp.588-590
    • /
    • 1999
  • It is now generalized to perform cardiac surgery in the patients with end-stage renal disease. The growing number of patients with chronic renal failure wake us up to the need to prepare for proper management. There are not only the prevalence of coronary artery disease, but also a great amount of valve dysfunction exist in this group. Peritoneal dialysis may be one of the obstacles for cardiopulmonary bypass but it is not a great hindrance in cardiac surgery with careful preparation and well organized perioperative care. The author has performed mitral valve replacement in a 33-year-old anuric female patient with chronic renal failure and severe mitral insufficiency. Preoperatively, the patient was kept in adequate fluid and electrolyte balance using peritoneal dialysis. Peritoneal dialysis continued and regulated according to the laboratory data in this patient during and after the surgery. She recovered well showing an uneventful course and was discharged on postoperative 1 th day.

  • PDF

Clinic Analysis of Heart Surgery -110 cases- (심장수술 110례 임상고찰)

  • Chang, Hoon;Shin, Sung-Aia;No, Joong-Kee;Rho, Jun-Ryang
    • Journal of Chest Surgery
    • /
    • v.34 no.8
    • /
    • pp.597-603
    • /
    • 2001
  • Background: The purpose of writing this article is to get better clinical results and further clinical improvement based on subject to 110 cases of cardiac surgery which were performed and clinically analyzed. Material and Method: Since January 1995, the patent ductus arteriosus surgery had started in our hospital. In February 1999, an open heart surgery had started and up to September 2000, total of 110 cases were performed as of double ligation of patent ductus arteriosus(10 cases) and open heart surgery(100 cases). Result: Among the patients, Korean-Chines was 74(67.3%) and Han-Chinese was 35(31.8%). Congenital heart disease was 95 cases and acquired valvular heart disease was 15 cases. 83 cases of acyanotic congenital heart disease consisted of ventricular septal defect(VSD) with associated anomaly(45 cases), atrial septal defect(ASD) with associated anomaly(20 cases), patent ductus arteriosus(PDA) with associated anomaly(11 cases), cogenital aortic stenosis(5 cases), double chamber right ventrical(1 case) and Ebstein's anomaly(1 case). Among the 12 cases of cyanotic congenital heart disease, 11 cases of tetralogy of Fallot underwent total correction. Among the 15 cases of acquired valvular heart disease, valvular replacement(7 cases), double valve replacement (3 cases), mitral valve replacement(3 cases) and aortic valve replacement(1 case) were performed. And 8 cases of valvuloplasty were performed by using of commissurotomy, chordal plasty, plasty of papillary muscle, ring type annuloplasty, repair of leaflet. Conclusion: on cogenital heart disease, short term results of surgery for acyanotic cogenital heart disease was good. Among the cyanotic congenital heart disease, tetralogy of Fallot showed a little difference of recovery according to the surgery method so that further follow up observation was needed for long term result. On acquired valvular heart disease, especially, in terms of short term result of valvuloplasty, was relatively good, but further follow up observation was also needed for long term result. There wasn's any operative mortality.

  • PDF

Establishment of Valve Replacement Registry and Risk Factor Analysis Based on Database Application Program (데이터베이스 프로그램에 기반한 심장판막 치환수술 환자의 레지스트리 확립 및 위험인자 분석)

  • Kim, Kyung-Hwan;Lee, Jae-Ik;Lim, Cheong;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.35 no.3
    • /
    • pp.209-216
    • /
    • 2002
  • Background: Valvular heart disease is still the most common health problem in Korea. By the end of the year 1999, there has been 94,586 cases of open heart surgery since the first case in 1958. Among them, 36,247 cases were acquired heart diseases and 20,704 of those had valvular heart disease. But there was no database system and every surgeon and physician had great difficulties in analysing and utilizing those tremendous medical resources. Therefore, we developed a valve registry database program and utilize it for risk factor analysis and so on. Material and Method: Personal computer-based multiuser database program was created using Microsoft AccessTM. That consisted of relational database structure with fine-tuned compact field variables and server-client architecture. Simple graphic user interface showed easy-to-use accessability and comprehensibility. User-oriented modular structure enabled easier modification through native AccessTM functions. Infinite application of query function aided users to extract, summarize, analyse and report the study result promptly. Result: About three-thousand cases of valve replacement procedure were performed in our hospital from 1968 to 1999. Total number of prosthesis replaced was 3,700. The numbers of cases for mitral, aortic and tricuspid valve replacement were 1600, 584, 76, respectively. Among them, 700 patients received prosthesis in more than two positions. Bioprosthesis or mechanical prosthesis were used in 1,280 and 1,500 patients respectively Redo valve replacements were performed in 460 patients totally and 40 patients annually Conclusion: Database program for registry of valvular heart disease was successfully developed and used in personal computer-based multiuser environment. This revealed promising results and perspectives in database management and utilization system.

Absent Pulmonary Valve with Intact Ventricular Septum, PDA. ASD (온전한 심실중격을 가진 폐동맥판막무형성증, 동맥관개존, 심방중격결손의 수술치험 1례)

  • 유지훈;박계현;이영탁;박표원;전태국
    • Journal of Chest Surgery
    • /
    • v.35 no.8
    • /
    • pp.590-593
    • /
    • 2002
  • Absent pulmonary valve syndrome with intact ventricular septum(APVS with IVS) is a rare congenital anomaly. The severe form of this syndrome, characterized by severe respiratory distress presented soon after birth, has been attributed to the compression of the airways caused by aneurysmal dilatation of pulmonary artery. Several operative treatments such as pulmonary valve insertion, or reductive angioplasty of pulmonary artery have been applied. We present a 3-day-old male who showed improvement after PDA ligation, reductive angioplasty of pulmonary artery, pulmonary valve reconstruction, and ASD closure.

Congenital Quadricuspid Aortic Valve Disease (선천성 사엽성 대동맥 판막 질환)

  • Park Chan Beom;Kim Jae Jun;Jo Min Seop;Jin Ung;Cho Deog-Gon;Park Kuhn;Cho Kyu-Do;Kim Chi Kyung
    • Journal of Chest Surgery
    • /
    • v.38 no.11 s.256
    • /
    • pp.780-782
    • /
    • 2005
  • The quadricuspid aortic valve is a rare congenital cardiac morphology. In regard to the hemodynamics of the quadricuspid aortic valve, the regurgitation is most common, the regurgitation accompanying the stenosis or pure stenosis are rare. We report hear a case with quadricuspid aortic valve disease which has been known to be extremely rare.

Clinical Analysis of Repeated Heart Valve Replacement (심장판막치환술 후 재치환술에 관한 임상연구)

  • Kim, Hyuck;Nam, Seung-Hyuk;Kang, Jeong-Ho;Kim, Young-Hak;Lee, Chul-Burm;Chon, Soon-Ho;Shinn, Sung-Ho;Chung, Won-Sang
    • Journal of Chest Surgery
    • /
    • v.40 no.12
    • /
    • pp.817-824
    • /
    • 2007
  • Background: There are two choices for heart valve replacement-the use of a tissue valve and the use of a mechanical valve. Using a tissue valve, additional surgery will be problematic due to valve degeneration. If the risk of additional surgery could be reduced, the tissue valve could be more widely used. Therefore, we analyzed the risk factors and mortality of patients undergoing repeated heart valve replacement and primary replacement. Material and Method: We analyzed 25 consecutive patients who underwent repeated heart valve replacement and 158 patients who underwent primary heart valve replacement among 239 patients that underwent heart vale replacement in out hospital from January 1995 to December 2004. Result: There were no differences in age, sex, and preoperative ejection fraction between the repeated valve replacement group of patients and the primary valve replacement group of patients. In the repeated valve replacement group, the previously used artificial valves were 3 mechanical valves and 23 tissue valves. One of these cases had simultaneous replacement of the tricuspid and aortic valve with tissue valves. The mean duration after a previous operation was 92 months for the use of a mechanical valve and 160 months for the use of a tissue valve. The mean cardiopulmonary bypass time and aortic cross clamp time were 152 minutes and 108 minutes, respectively, for the repeated valve replacement group of patients and 130 minutes and 89 minutes, respectively, for the primary valve replacement group of patients. These results were statistically significant. The use of an intra aortic balloon pump (IABP) was required for 2 cases (8%) in the repeated valve replacement group of patients and 6 cases (3.8%) in the primary valve replacement group of patients. An operative death occurred in one case (4%) in the repeated valve replacement group of patients and occurred in nine cases (5.1%) in the primary valve replacement group of patients. Among postoperative complications, the need for mechanical ventilation over 48 hours was different between the two groups. The mean follow up period after surgery was $6.5{\pm}3.2$ years. The 5-year survival of patients in the repeated valve replacement group was 74% and the 5-year survival of patients in the primary valve replacement group was 95%. Conclusion: The risk was slightly increased, but there was little difference in mortality between the repeated and primary heart valve replacement group of patients. Therefore, it is necessary to reconsider the issue of avoiding the use of a tissue valve due to the risk of additional surgery, and it is encouraged to use the tissue valve selectively, which has several advantages over the use of a mechanical valve. In the case of a repeated replacement, however, the mortality rate was high for a patient whose preoperative status was not poor. A proper as sessment of cardiac function and patient status is required after the primary valve replacement. Subsequently, a secondary replacement could then be considered.

The Clinical Results of Heart Valve Replacements (심장 판막 치환술의 임상 성적)

  • Park Sung Min;Son Hosung;Shin Jaesung;Sohn Young-sang;Sun Kyung;Choi Young Ho;Kim Kwan Taik;Lee In Sung;Kim Hackje;Kim Hyung Mook
    • Journal of Chest Surgery
    • /
    • v.38 no.3 s.248
    • /
    • pp.204-213
    • /
    • 2005
  • In spite of the improvement in the quality of artificial heart valves and surgical techniques, the incidence of the complications following valve replacement is still high. We reviewed the clinical results of the valve replacements peformed in Korean University Anam Hospital during the last 26 years. Material and Method: The data of 571 patients who received valve replacement between December 1976 and December 2003 were reviewed. Result: There were 304 cases of MVR which was the most common procedure performed. There were 122 cases of AVR, and 111 cases of AVR with MVR. Among the 47 patients who received redo operation 38 cases were redo cases including 31 cases of MVR. $32.5\%$ of the patients who had tissue valve replacement had second valve replacement with 10.2 $\pm$ 3.9 years interval. $24.3\%$ (139/571) of the patients developed valve related complications and cerebral infarction was the highest in frequency. Atrial fibrillation was related with increased complication rates and the mechanical valve replaced group had higher hemorrhagic complication rate than tissue valve replaced group. The operative mortality was $3.68\%$ and the most common cause of the failure was low output syndrome. The operative mortality was higher in the patient group who had valve replacement before the year 1990. The patient group who had mechanical valve replacement had higher operative mortality rate th;3n the tissue valve group. The 5-year survival rate was $92.2\%$ and 10 year survival rate was $85.7\%$. Conclusion: The operative mortality of valve replacement has been improved. The mechnical valve replaced patients had higher hemorrhagic complication rate than the tissue valve replaced patients and more tissue valve replaced patients received redo valve replacement.

The Cox-Maze Procedure for Atrial Fibrillation Concomitant with Mitral Valve Disease (승모판막질환에 동반된 심방세동에서 Cox-Maze 술식)

  • Kim, Ki-Bong;Cho, Kwang-Ree;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.31 no.10
    • /
    • pp.939-944
    • /
    • 1998
  • Background: The sugical results of the Cox-Maze procedure (CMP) for lone atrial fibrillation(AF) have proven to be exellent. However, those for AF associated with mitral valve(MV) disease have been reported to be a little inferior. Materials and methods: To assess the efficacy and safety of the CMP as a combined procedure with MV operation, we studied retrospectively our experiences. Between April 1994 and October 1997, we experienced 70 (23 males, 47 females) cases of CMP concomitantly with MV operation. Results: The etiologies of MV disease were rheumatic in 67 and degenerative in 3 cases. The mean duration of AF before sugery was 66$\pm$70 months. Fifteen patients had the past medical history of thromboembolic complications, and left atrial thrombi were identified at operation in 24 patients. Twelve cases were reoperations. Aortic cross clamp (ACC) time was mean 151$\pm$44 minutes, and cardiopulmonary bypass (CPB) time was mean 246$\pm$65 minutes. Concomitant procedures were mitral valve replacement (MVR) in 19, MVR and aortic valve replacement (AVR) in 14, MVR and tricupid annuloplasty (TAP) in 8, MVR with AV repair in 3, MV repair in 11, MVR and coronary artery bypass grafting (CABG) in 2, MVR and AVR and CABG in 1, redo-MVR in 10, redo-MVR and redo-AVR in 2 patients. The rate of hospital mortality was 1.4%(1/70). Perioperative recurrence of AF was seen in 44(62.9%), and atrial tachyarrhythmias in 10(14.3%), low cardiac output syndrome in 4(5.7%), postoperative bleeding that required mediastinal exploration in 4(5.7%) patients. Other complications were acute renal failure in 2, aggravation of preoperative hemiplegia in 1, and transient delirium in 1 patient. We followed up all the survivors for 16.4 months(3-44months) on an average. Sinus rhythm has been restored in 65(94.2%) patients. AF has been controlled by operation alone in 73.9% and operation plus medication in 20.3%. Two patients needed permanent pacemaker implantation; one with sick sinus syndrome, and the other with tachycardia- bradycardia syndrome. Only two patients remained in AF. We followed up our patients with transthoracic echocardiography to assess the atrial contractilities and other cardiac functions. Right atrial contractility could be demonstrated in 92% and left atrial contractility in 53%.We compared our non-redo cases with redo cases. Although the duration of AF was significantly longer in redo cases, there was no differences in ACC time, CPB time, postoperative bleeding amount and sinus conversion rate. Conclusions: In conclusion, the CMP concomitant with MV operation demonstrated a high sinus conversion rate under the acceptable operative risk even in case of reoperation.

  • PDF

A Clinical Analysis on the Restoration of Sinus Rhythm Following Mitral Valve Surgery (승모판 수술 후 동율동 회복에 관한 임상분석)

  • 백완기;심상석;김현태;조상록;진성훈
    • Journal of Chest Surgery
    • /
    • v.32 no.4
    • /
    • pp.347-352
    • /
    • 1999
  • Background: The atrial fibrillation in patients with mitral valvular heart disease is frequently converted to sinus rhythm after the mitral valve surgery. This sinus restoration implies an important meaning in that it not only helps postoperative convalescence in patients with unstable hemodynamics but also reduces the rate of postoperative thromboembolism. Material and Method: We retrospectively analyzed 184 patients who received mitral valve surgery from June 1986 to December 1996 to investigate the trend of rhythm change following mitral valve surgery and thus to clarify the predisposing factors of postoperative sinus rhythm conversion and its maintenance. Result: The sinus rhythm was restored after the operation in 54 out of 139 patients with atrial fibrillation preoperatively(38.8%). However, the atrial fibrillation recurred in 41 patients at the time of discharge showing a recurrence rate of 75.9 percent. The mean duration of sinus rhythm in patients with eventual atrial fibrillation recurrence was 8.2${\pm}$5.9 days. Only 15 patients were in sinus rhythm at the time of late follow-up with the mean follow-up period of 84.4${\pm}$34.7 months. While the age, duration of symptoms, duration of atrial fibrillation, left atral size, and pulmonary artery pressure were thought to be the predisposing factors for sinus conversion after the operation, only the duration of atrial fibrillation and ejection fraction were considered risk factors for the recurrence of the atrial fibrillation following sinus conversion. Conclusion: This study suggests that the early operation is mandatory for the satisfactory result regarding postoperative rhythm. Moreover, additional operative measure in adjunct to the intervention of mitral valve should be considered for the maintenance of restored sinus rhythm as reflected by high postoperative recurrence rate of atrial fibrillation.

  • PDF

Fibrocalcific Embolism of Right Coronary Artery Combined with Aortic Valvular Stenosis (대동맥판협착증에 동반된 우관상동맥의 석회성 색전증)

  • 장성욱;박정옥;김영권;이명용;류재욱;박성식;서필원;김삼현
    • Journal of Chest Surgery
    • /
    • v.36 no.11
    • /
    • pp.858-861
    • /
    • 2003
  • The main cause of ischemic heart disease combined with aortic valve disease is the systemic atherosclerotic process. Coronary artery embolism by a particle from the calcified aortic valvular tissue is very rare. A 73-year-old female patient was admitted due to chest tightness of recent onset. Two dimensional echocardiogram showed severe calcific aortic valve stenosis. Preoperative coronary angiogram exhibited a stenotic lesion at the distal right coronary artery, which seemed to be embolic in origin. The coronary embolus was removed through the coronary arteriotomy and then the arteriotomy site was repaired by onlay patch angioplasty technique. Aortic valve was replaced by a bioprosthetic valve. The embolus was reported as a fibrocalcified particle of diseased valve.