• Title/Summary/Keyword: 심장전기도

Search Result 206, Processing Time 0.026 seconds

Effects of Sodium Bicarbonate on Electrocardiogram in Hyperkalemia (과칼륨혈증의 심전도변화와 중조(重曹)투여가 이에 미치는 영향)

  • Cho, Young-Ho;Chae, E-Up
    • The Korean Journal of Physiology
    • /
    • v.16 no.1
    • /
    • pp.41-50
    • /
    • 1982
  • The effects of $NaHCO_3$ on the electrocardiogram of rats were studied in the induced hyperkalemia. The subjects were divided into 4 groups: the group 1 was normal control and the data on this normal control had teen obtained from the following three groups before administration of KCl or $NaHCO_3$, the group 2 (KCl) was administered 40 ml per kg body weight of the 10 per cent KCl solution, the group 3 $(NaHCO_3)$ was administered 40 ml per kg body weight of the 10 per cent $NaHCO_3$ solution, and the group 4 $(KCl+NaHCO_3)$ was received 10 per cent KCl, which was followed by administration of 10 per cent $NaHCO_3$ at one and half hours later. In KCl, the heart rate was decreased rapidly, and then maintained its level, later rapid decreasing heart rate was followed by the cardiac stand still. The mean electrical axis of QRS complex became progressively deviated to the left. The amplitude of T wave was increased transiently but was not changed thereafter. There was prolongation of the P-Q interval and the Q-T interval at the beginning and then they were shortened. In $NaHCO_3$, the heart rate was decreased rapidly at the beginning, later showed a tendency of recovery. The mean electrical axis of QRS was not changed initially, but later became deviated to the left. The amplitude of T wave was not changed. There was prolongation of the P-Q interval and the Q-T interval at the beginning and then they were shortened. In $KCl+NaHCO_3$, there were a tendency of recovery of both the amplitude of the T wave and the electrical axis of the QRS complex after administration of $NaHCO_3$ but the heart rate was not recovered. There was prolonged P-Q interval, but the Q-T interval was relatively unchanged.

  • PDF

Effects of Whole Body Electric Muscle Stimulation Training on Body Composition and Heart Rate Variability based on Obesity Level in Women

  • Seung-Hyeon Lim;Jin-Wook Lee;Yong-Hyun Byun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.29 no.3
    • /
    • pp.137-146
    • /
    • 2024
  • The purpose of this study was to determine the effects of 12 weeks of WB-EMS training on body composition and heart rate variability based on BMI Level in Women. The subjects of the study were premenopausal women, and they were classified into the BMI-N(n=15) group for BMI<25, the BMI-1(n=16) group for BMI=25~29.9, and the BMI-2(n=9) group for BMI>30. And then, WB-EMS training was performed of 3 times a week for 12 weeks. Body composition and HRV were measured before and after the participation in exercise, which were subjected to a repeated-measures two-way ANOVA. In the case of a significant interaction between time and group, paired sample t-tests were conducted for a post-hoc analysis within each subject group. Tukey's method was used for post-hoc testing of differences between groups, and the significance level was set at 0.5. The results were as follows; First, The effect of WB-EMS training was found in all variables of body composition. In particular, Weight, BMI, FFM, and FM decreased the most in the BMI-2 group, followed by the BMI-1 and BMI-N groups. %BF and VF decreased the most in the BMI-2 group. Second, There was a difference in BPM in all groups, and the BMI-2 group showed the greatest decrease. There were differences in SDNN and RMSSD for each group, and there was no difference according to obesity level. There was no difference in LF, HF, and LF/HF ratio. In conclusion, it was confirmed that WB-EMS training can be an exercise therapy that has a positive effect on the body composition change and cardiac circulatory system in women with a high level of obesity.

SVM Classifier for the Detection of Ventricular Fibrillation (SVM 분류기를 통한 심실세동 검출)

  • Song, Mi-Hye;Lee, Jeon;Cho, Sung-Pil;Lee, Kyoung-Joung
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.42 no.5 s.305
    • /
    • pp.27-34
    • /
    • 2005
  • Ventricular fibrillation(VF) is generally caused by chaotic behavior of electrical propagation in heart and may result in sudden cardiac death. In this study, we proposed a ventricular fibrillation detection algorithm based on support vector machine classifier, which could offer benefits to reduce the teaming costs as well as good classification performance. Before the extraction of input features, raw ECG signal was applied to preprocessing procedures, as like wavelet transform based bandpass filtering, R peak detection and segment assignment for feature extraction. We selected input features which of some are related to the rhythm information and of others are related to wavelet coefficients that could describe the morphology of ventricular fibrillation well. Parameters for SVM classifier, C and ${\alpha}$, were chosen as 10 and 1 respectively by trial and error experiments. Each average performance for normal sinus rhythm ventricular tachycardia and VF, was 98.39%, 96.92% and 99.88%. And, when the VF detection performance of SVM classifier was compared to that of multi-layer perceptron and fuzzy inference methods, it showed similar or higher values. Consequently, we could find that the proposed input features and SVM classifier would one of the most useful algorithm for VF detection.

Purification and Characterization of Cytochrome c Oxidase from Photosynthetic Bacterium, Rhodopseudomonas gelatinosa (광합성세균 Rhodopseudomonas gelatinosa 의 시토크롬 c 산화효소의 정제 및 특성)

  • 강대길;최원기
    • Korean Journal of Microbiology
    • /
    • v.30 no.2
    • /
    • pp.101-107
    • /
    • 1992
  • Cytochrome c oxida5e from chemotrophically grown R p , geliitinosu was purified by cytochrome c affinity chromatography and DEAE-Sephacel ion exchange chromatography. The molecular weight of the cytochrome c oxidase was approximately 110.000 Da by sephacryl s-300 gel chromatography and approximately 52, 000 Da by SDS-gel electrophoresis, respectively. Therefore. cytochrolne c oxidase of Rps. gehtinosu seems to be dimer. The cytochrome c oxidasc was very sensitive to temperature. It's Km and Vmax were 20 pM and 44 unitlmg protein for horsc heart cytochrome c as a substrate. respectively, and its optimum pH and temperature were 6.4 and 25$^{\circ}$C. respectively. The absorption peaks of the reduced cytochrome c oxidase showed at 554 nm, 523 nm. and 422 nm. The activiiy of cytochrome c oxidase was inhibited by KCN, and NaN3, but not by CO, antimycir~ A. and myxothiazol. The cytochrome c-551 was produced either in phototrophically or chemotrophically grown Rps. gelaiinosci. The rcduced cytochrome c-551 was oxidized by b-type cytochrome c oxidase from Rp.v. gc.lrtino.sc~. Km and Vmax of cytochrome c oxidase was 26 pM and 31 unitlnlg protein For cytochrome c-551 as a substrate. respectively. Thercfore. thc electron transfer chain of chemotrophically grown Rps. glatinosa seems lo be ubiquinol cytochrome bc, complex -'cytochrome c-55lMb-type cytochrome c oxidase+02.

  • PDF

Protein Synthesis during Somatic Embryo Development and Artificial Seed Germination of Apium graveolens L. after Abscisic Acid or Cold Treatment (쎌러리(Apium graveolens L.)의 체세포배 발생 및 인공종자 발아에 있어서 앱시스산 및 저온처리에 의한 단백질 합성)

  • 소웅영;여읍동;소상섭;조덕이
    • Korean Journal of Plant Tissue Culture
    • /
    • v.21 no.1
    • /
    • pp.15-22
    • /
    • 1994
  • To understand the molecular mechanism of hardening process in somatic embryo development and artificial seed germination in celery (Apium graveolens L.), the changes of protein synthesis by ABA or cold teatment at early globular stage were examined. Protein content and nitrate reductase activity in ABA- or cold-treated somatic embryo and seedlings were higher than that in unheated ones. The protein content and nitrate reductase activity were more prominent in somatic embryos than in seedlings. From two-dimensional electrophoresis, several protein spots specific to ABA or cold treatment were identified: 30 KD, 32 KD, 171 KD and 205 KD at heart-shaped stage; and 29 KD, 33 KD, 37 KD, 38 KD, 41 KD, 55 KD, 66 KD, and 110 KD at cotyledonary stage were the most specifically synthesized However the synthesis of certain polypeptides were repressed at heart-shaped or cotyledonary stage: 42 KD, 44 KD, 59 KD, 64 KD, 101 KD, 104 KD, and 190 KD at heart-shaped stage; and 29 KD and 116 KD at cotyledonary stage. The protein pattern changes by ABA or cold treatment occurred simultaneously and mainly in acid-soluble proteins during somatic embryo development and artificial seed germination. Therefore it is suggested that the metabolic changes for adaptation to environmental change occur during somatic embryo development and the germination and growth of seedling from embryo.

  • PDF

P Wave Detection Algorithm through Adaptive Threshold and QRS Peak Variability (적응형 문턱치와 QRS피크 변화에 따른 P파 검출 알고리즘)

  • Cho, Ik-sung;Kim, Joo-Man;Lee, Wan-Jik;Kwon, Hyeog-soong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.8
    • /
    • pp.1587-1595
    • /
    • 2016
  • P wave is cardiac parameters that represent the electrical and physiological characteristics, it is very important to diagnose atrial arrhythmia. However, It is very difficult to detect because of the small size compared to R wave and the various morphology. Several methods for detecting P wave has been proposed, such as frequency analysis and non-linear approach. However, in the case of conduction abnormality such as AV block or atrial arrhythmia, detection accuracy is at the lower level. We propose P wave detection algorithm through adaptive threshold and QRS peak variability. For this purpose, we detected Q, R, S wave from noise-free ECG signal through the preprocessing method. And then we classified three pattern of P wave by peak variability and detected adaptive window and threshold. The performance of P wave detection is evaluated by using 48 record of MIT-BIH arrhythmia database. The achieved scores indicate the average detection rate of 92.60%.

Implementation of the ECG Monitoring System for Home Health Care Using Wiener Filtering Method (Wiener Filtering 기법을 적용한 홈헬스케어용 심전도 신호 모니터링 시스템 구현)

  • Jeong, Do-Un;Kim, Se-Jin
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.9 no.2
    • /
    • pp.104-111
    • /
    • 2008
  • The ECG is biomedical electrical signal occurring on the surface of the body due to the contraction and relaxation of the heart. This signal represents an extremely important measure for health monitoring, as it provides vital information about a patient's cardiac condition and general health. ECG signals are contaminated with high frequency noise such as power line interference, muscle artifact and low frequency nose such as motion artifact. But it is difficult to filter nose from ECG signal, and errors resulting from filtering can distort a ECG signal. The present study implemented a small-size and low-power ECG measurement system that can remove motion artifact for convenient health monitoring during daily life. The implemented ECG monitoring system consists of ECG amplifier, a low power microprocessor, bluetooth module and monitoring program. Amplifier was designed and implemented using low power instrumentation amplifier, and microprocessor was interfaced to the ECG amplifier to collect the data, process, store and feed to a transmitter. And bluetooth module used to wirelessly transmit and receive the vital sign data from the microprocessor to an PC at the receiving site. In order to evaluate the performance of the implemented system, we assessed motion artifact rejection performance in each situation with artificially set condition using adaptive filter.

  • PDF

Using the X-ray Image, Augmented Reality based electrocardiogram measurement system Development (X-ray 이미지를 활용한 증강현실 기반 심전도 측정시스템 개발)

  • Lee, Kwang-In;Jang, Jin-Soo;Lee, Tae-Ro
    • Journal of Digital Convergence
    • /
    • v.14 no.9
    • /
    • pp.331-339
    • /
    • 2016
  • Chronic diseases are increasing nowadays as daily habits changed due to economic growth. Among chronic diseases, heart cerebrovascular disease is one of the major causes of death in South Korea that accounts for approximately 20% of mortality. Tests to measure anomaly of the heart is ECG tests, which measures and analyzes the electrical heart activity. Any mistakes in lead attachment location critically affects ECG testings, and statistical facts showed that only 2.8% of the nurses properly located leads to patients. As a solution, this paper proposes a system based on a projection-based augmented reality technology to generate X-ray images to the patient's chest to point out exact attachment locations of ECG leads. Evaluation comparison results showed a 2.6 cm difference between the conventional system and the proposed system. ECG test results also showed significant signal differences between the systems in leads V1, V2, and V3. The ECG measured accurately by the proposed system would help greatly in patient management and clinical decisions of clinicians.

Development of a Pacemaker with a Ventricular Assist Device for End-Stage Heart Failure Patients (말기 심질환 환자를 위한 심실보조장치용 심박조율기의 개발)

  • Kim, Yoo-Seok;Park, Sung-Min;Choi, Seong-Wook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.11
    • /
    • pp.1205-1211
    • /
    • 2011
  • In this paper, we developed a pacemaker that can increase the efficacy of a left ventricular assist device (LVAD) and increase the survival rate for patients suffering end-stage heart failure. Because LVAD patients can experience arrhythmia, the pacemaker incorporated into the LVAD has the important role of sustaining sufficient blood circulation during arrhythmia. The electrode of the pacemaker is located at the apex of the left ventricle, where the VAD's inlet cannula is connected. This is efficient placement, in that the electrode can transmit electrical stimulation directly to the Purkinje fibers of the myocardium. The pacemaker can change the stimulation rate from 0 bpm to 191.4 bpm when a button is pressed on the external control module, and the pacemaker normally stimulates the heart at 60 bpm with 0.25 J of energy. We performed animal experiments to evaluate the performance and reliability of the combination of the LVAD and pacemaker. At pacemaker stimulation rates of 86.4 bpm, 100.2 bpm, 126.6 bpm, we recorded the ECGs, aortic pressures, and flow rates to analyze the heart loads.

Computed Tomography of the Left Atrium and Left Atrial Appendage: A Pictorial Essay on the Anatomy, Normal Variants, and Pathology (좌심방과 좌심방이의 전산화단층촬영 소견: 해부학, 정상변이 및 질환에 관한 임상화보 )

  • Minji Song; Sung Jin Kim;Hyun Jung Koo;Moon Young Kim;Jin Young Yoo
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.2
    • /
    • pp.272-289
    • /
    • 2020
  • Current advances in CT techniques allow thorough evaluation of the beating heart. The strengths of cardiac CT relative to echocardiography and magnetic resonance imaging are its high availability in most institutions, rapid production of high-quality images, and outstanding delineation of the anatomy. For many normal variants and pathologic conditions, such as thrombi, masses, and congenital abnormalities of the left atrium, CT findings are sufficient to make a presumptive diagnosis. Assessments of the left atrium and left atrial appendage are particularly important for the management of atrial fibrillation, as various catheter-based procedures are aimed at the mechanical and electrical isolation of these structures. CT offers information crucial to a successful catheter-based procedure or surgery. Therefore, a comprehensive review of the geometry (shape, size, and relative position), along with various CT imaging features of pathologic states, should be provided in radiology reports to be of clinical value.