Clinical Application of Stent-graft in Thoracic Aortic Diseases (흉부 대동맥 질환에서 스텐트-그라프트의 임상적 적용)

  • Kim, Kyung-Hwan;Lee, Cheul;Chang, Ji-Min;Chung, Jin-Wook;Ahn, Hyuk;Park, Jae-Hyung
    • Journal of Chest Surgery
    • /
    • v.34 no.9
    • /
    • pp.698-703
    • /
    • 2001
  • Background: Endovascular stent-graft insertion in aortic diseases is now generally accepted as an attractive alternative treatment modality. We reviewed our clinical experiences of endovascular stent-graft insertion in thoracic aorta. Material and Method: Since 1995, we performed 8 cases of endovasclar stent-graft insertion. Preoperative diagnoses were aortic aneurysms in 4, traumatic aortic ruptures in 3, and ruptured aortic pseudoaneurysm in 1. All procedures were performed in angiography room with the guidance of fluoroscopy. The stent-graft device is a custom-made 0.35mm thickness Z-shaped stainless steel wires, intertwined with each other using polypropylene suture ligation. It is covered with expanded Dacron vascular graft. Result: All procedures were performed successfully. Follow-up studies revealed 2 minimal perigraft leakages. There was no significant leakage or graft migration. 2 patients expired due to multiple organ failure and fungal sepsis. Other survivors(6) are doing well. Conclusion: Endovascular stent-graft insertion is relatively saft and effective treatment modality in the managment of various types of aortic diseases. In may be an effective alternative in aortic diseases of great surgical risk.

  • PDF

A Refined Method for Quantification of Myocardial Blood Flow using N-13 Ammonia and Dynamic PET (N-13 암모니아와 양전자방출단층촬영 동적영상을 이용하여 심근혈류량을 정량화하는 새로운 방법 개발에 관한 연구)

  • Kim, Joon-Young;Lee, Kyung-Han;Kim, Sang-Eun;Choe, Yearn-Seong;Ju, Hee-Kyung;Kim, Yong-Jin;Kim, Byung-Tae;Choi, Yong
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.1
    • /
    • pp.73-82
    • /
    • 1997
  • Regional myocardial blood flow (rMBF) can be noninvasively quantified using N-13 ammonia and dynamic positron emission tomography (PET). The quantitative accuracy of the rMBF values, however, is affected by the distortion of myocardial PET images caused by finite PET image resolution and cardiac motion. Although different methods have been developed to correct the distortion typically classified as partial volume effect and spillover, the methods are too complex to employ in a routine clinical environment. We have developed a refined method incorporating a geometric model of the volume representation of a region-of-interest (ROI) into the two-compartment N-13 ammonia model. In the refined model, partial volume effect and spillover are conveniently corrected by an additional parameter in the mathematical model. To examine the accuracy of this approach, studies were performed in 9 coronary artery disease patients. Dynamic transaxial images (16 frames) were acquired with a GE $Advance^{TM}$ PET scanner simultaneous with intravenous injection of 20 mCi N-13 ammonia. rMBF was examined at rest and during pharmacologically (dipyridamole) induced coronary hyperemia. Three sectorial myocardium (septum, anterior wall and lateral wall) and blood pool time-activity curves were generated using dynamic images from manually drawn ROIs. The accuracy of rMBF values estimated by the refined method was examined by comparing to the values estimated using the conventional two-compartment model without partial volume effect correction rMBF values obtained by the refined method linearly correlated with rMBF values obtained by the conventional method (108 myocardial segments, correlation coefficient (r)=0.88). Additionally, underestimated rMBF values by the conventional method due to partial volume effect were corrected by theoretically predicted amount in the refined method (slope(m)=1.57). Spillover fraction estimated by the two methods agreed well (r=1.00, m=0.98). In conclusion, accurate rMBF values can be efficiently quantified by the refined method incorporating myocardium geometric information into the two-compartment model using N-13 ammonia and PET.

  • PDF

Usefulness of Pulsatile Flow Aortic Aneurysm Phantoms for Stent-graft Placement (스텐트그라프트 장치술을 위한 대동맥류 혈류 팬텀의 유용성)

  • Kim, Tae-Hyung;Ko, Gi-Young;Song, Ho-Young;Park, In-Kook;Shin, Ji-Hoon;Lim, Jin-Oh;Kim, Jin-Hyoung;Choi, Eu-Gene K.
    • Journal of radiological science and technology
    • /
    • v.30 no.3
    • /
    • pp.205-212
    • /
    • 2007
  • To evaluate the feasibility and efficacy of a pulsatile aortic aneurysm phantoms for in-vitro study. The phantoms consisted of a pulsating motor part(heart part) and an aortic aneurysm part, which mimicked true physiologic conditions. The heart part was created from a high-pressured water pump and a pulsatile flow solenoid valve for the simulation of aortic flow. The aortic aneurysm part was manufactured from paper clay, which was placed inside a acrylic plastic square box, where liquid silicone was poured. After the silicone was formed, the clay was removed, and a silicone tube was used to connect the heart and aneurysm part. We measured the change in pressure as related to the opening time(pulse rate, Kruskal-Wallis method) and pressure before and after the stent-graft implantation(n = 5, Wilcoxon's signed ranks test). The changes in blood pressures according to pulse rate were all statistically significant(p<0.05). The systolic/diastolic pressures at the proximal aorta, the aortic aneurysm, and the distal aorta of the model were $157.80{\pm}1.92/130.20{\pm}1.92$, $159.40{\pm}1.14/134.00{\pm}2.92$, and $147.20{\pm}1.480/129.60{\pm}2.70\;mmHg$, respectively, when the pulse rate was 0.5 beat/second. The pressures changed to $161.40{\pm}1.34/90.20{\pm}1.64$, $175.00{\pm}1.58/93.00{\pm}1.58$, and $176.80{\pm}1.48/90.80{\pm}1.92\;mmHg$, respectively, when the pulse rate was 1.0 beat/second, and $159.40{\pm}1.82/127.20{\pm}1.48$, $166.60{\pm}1.67/138.00{\pm}1.87$, and $161.00{\pm}1.22/135.40{\pm}1.67\;mmHg$, respectively, when it was 1.5 beat/second. When pulse rate was set at 1.0 beat/second, the pressures were $143.60{\pm}1.67/90.20{\pm}1.64$, $147.20{\pm}1.92/84.60{\pm}1.82$, and $137.40{\pm}1.52/88.80{\pm}1.64\;mmHg$ after stent-graft implantation. The changes of pressure before and after stent-graft implantation were statistically significant(p<0.05) except the diastolic pressures at the proximal(p =1.00) and distal aorta(p=0.157). The aortic aneurysm phantoms seems to be useful for the evaluation of the efficacy of stent-graft before animal or clinical studies because of its easy reproducibility and ability to display a wide range of pressures.

  • PDF

A Preliminary Study on Emotion, Self-Esteem and Quality of Life in the Patients with Chest Pain (흉통 환자에서의 정서, 자존감 및 삶의 질에 대한 예비 연구)

  • Park, Sook Hyun;Jae, Young Myo;Lee, Dae Su;Jang, Saeheon;Choi, Jin Hyuk;Lee, Han Cheol
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.20 no.2
    • /
    • pp.120-126
    • /
    • 2012
  • Objectives : The objective of this study is to measure and to compare the rate of depression, anxiety, self-es-teem and the quality of life of the patients with chest pain. Based on the result of this study, the necessity of the psychiatric assessment and treatment of the patients with chest pain is emphasized. This study is a preliminary research for a larger scale investigation to be carried out in the future. Methods : Thirty nine patients with chest pain who visited Cardiovascular Division of Dept. of Internal Medicine Pusan National University Hospital and fourty normal control group(NC) were included in this study. The patients were classified into typical chest pain group(TCP, N=19) and atypical chest pain group(ACP, N=20) based on the cause of the pain. The cause was determined by cardiac computed tomography, exercise stress test, coronary angiography, and questionaires by a cardiology specialist. The patients were assessed with Beck Depression Inventory(BDI), State-Trait Anxiety Inventory(STAI), Rosenberg Self-Esteem Scale(RSES) and Korean version of the Smith Klein Beecham 'Quality of Life' scale(KvSBQOL). Results : 1) When the risk factors of cardiac disease is compared, most of the factors(Hypertension, Diabetes, Hyperlipidemia, Cerebral infarction) did not differ significantly among the two chest pain groups, except for the family history, for which TCP group showed higher risk than ACP group did. 2) As for the self-report questionaires scores, BDI score, which indicates the rate of depression, of both ACP group and TCP group was significantly higher than that of NC group in BDI for depression. STAI score, which measures anxiety, was also significantly high in both groups. Especially, STAI score was significantly higher in ACP group than TCP group. 3) In the aspect of self-esteem and quality of life, ACP group scored significantly lower than TCP group and NC group. The scores for TCP group and NC group did not differ significantly. Conclusions : The patients with chest pain showed more depression and anxiety than normal control group, regardless of the cause of the pain. However, TCP group did not show significantly larger drop in self-esteem and quality of life than ACP group did. This result implies that early psychiatric assessment and treatment is needed for the patients with such chest pain, since it is highly likely that the pain would lead to lower quality of life of the patients.

  • PDF