• Title/Summary/Keyword: 심실수

Search Result 363, Processing Time 0.026 seconds

The Feasibility of the DKUH-75 Left Ventricular Assist Device for Acute Cardiogenic Shock in Pigs (돼지의 급성 심인성 쇼크 모델에서 DKUH-75 좌심실보조키의 유용성에 관한 연구)

  • Park, Seong-Sik
    • Journal of Chest Surgery
    • /
    • v.40 no.3 s.272
    • /
    • pp.168-179
    • /
    • 2007
  • Background: The recent trend of an increasing number of patients with acute cardiogenic shock or chronic congestive heart failure following myocardial infarction, as well as the considerable number who can not be weaned from cardiopulmonary bypass after open heart surgery, call for immediate efforts to develop affordable ventricular assist devices that are suitable for the Korean physique. Recently, a pneumatic pulsatile ventricular assist device (VAD), named DKUH-75, has been developed by the Department of Biomedical Engineering, in collaboration with the Department of Thoracic and Cardiovascular Surgery of Dankook University College of Medicine. The feasibility of the DKUH-75 VAD was evaluated on the bases of common hemodynamic variables and echocardiographic measurements in pigs, which are subjected to an acute cardiogenic shock state following myocardial infarction, using a novel coronary artery ligation method employing the ischemic preconditioning concept. Material and Method: Acute cardiogenic shock was induced in 10 Yorkshire Landrace Duroc strain pigs by ligating the left anterior descending coronary artery via an ischemic preconditioning process. The hemodynamic variables were monitored, with epicardial echocardiographic measurements performed before and one hour after the ligation. The DKUH-75 VAD was implanted into 5 pigs one hour after the onset of the shock. The hemodynamic variables and echocardiographic measurements were taken one hour after installation of the VAD. Result: The systolic, diastolic and mean systemic arterial pressures were significantly decreased in all the experimental animals one hour after the ligation. The systolic, diastolic and mean pulmonary arterial pressures were increased (Eds note: this completely contradicts the preceding statement? However, if you mean the non-experimental animals this should be stated?). The left ventricular end diastolic pressure (LVEDP) was increased, but the cardiac index decreased, An increase in the left ventricular end systolic dimension and decreases in the fractional shortening and ejection fraction were observed all animals one hour after the coronary artery ligation. In all 5 of the VAD implanted pigs, the systolic and mean systemic arterial pressures were increased, and the pulmonary arterial pressures decreased one hour after the implantation; the LVEDP decreased, but the cardiac index was significantly increased, In the echocardiographic measurements, the left ventricular end systolic dimension decreased after the implantation of the VAD, but the fractional shortening and ejection fraction significantly increased. Conclusion: Significant improvements in the hemodynamic variables and echocardiographic measurements were observed in the 5 VAD implanted animals one hour after installation, which had been subjected to an acute cardiogenic shock state by ligation of the coronary artery, indicating that the DKUH-75 VAD could help in the recovery of the myocardial function. This suggests that the DKUH-75 VAD is feasible in the short term in relation to an acute cardiogenic shock state due to myocardial infarction.

Hybrid Procedure for Muscular Ventricular Septal Defects -2 case reports- (근육형 심실중격결손에 대한 하이브리드 수술법 -2예 보고-)

  • Choi, Seon-Uoo;Yang, Ji-Hyuk;Jun, Tae-Gook;Park, Pyo-Won;Min, Sun-Kyung;Kang, I-Seok
    • Journal of Chest Surgery
    • /
    • v.41 no.6
    • /
    • pp.747-750
    • /
    • 2008
  • Although surgical closure is the standard approach for a muscular ventricular septal defect, the procedure may be complicated by poor visualization and the need for incision on the ventricle. Another approach is, catheter-based intervention. However, it also has limitations. A hybrid procedure, the intraoperative combined use of an interventional device may reduce the procedure's invasiveness. We successfully managed two cases of muscular ventricular septal defect with a hybrid procedure. We report here on these 2 cases along with a review of the literature.

Patient Adaptive Pattern Matching Method for Premature Ventricular Contraction(PVC) Classification (조기심실수축(PVC) 분류를 위한 환자 적응형 패턴 매칭 기법)

  • Cho, Ik-Sung;Kwon, Hyeog-Soong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.9
    • /
    • pp.2021-2030
    • /
    • 2012
  • Premature ventricular contraction(PVC) is the most common disease among arrhythmia and it may cause serious situations such as ventricular fibrillation and ventricular tachycardia. Particularly, in the healthcare system that must continuously monitor patient's situation, it is necessary to process ECG (Electrocardiography) signal in realtime. In other words, the design of algorithm that exactly detects R wave using minimal computation and classifies PVC by analyzing the persons's physical condition and/or environment is needed. Thus, the patient adaptive pattern matching algorithm for the classification of PVC is presented in this paper. For this purpose, we detected R wave through the preprocessing method, adaptive threshold and window. Also, we applied pattern matching method to classify each patient's normal cardiac behavior through the Hash function. The performance of R wave detection and abnormal beat classification is evaluated by using MIT-BIH arrhythmia database. The achieved scores indicate the average of 99.33% in R wave detection and the rate of 0.32% in abnormal beat classification error.

Postcardiotomy Ventricular Support with Biomedicus Pump (Biomedicus pump를 이용한 개심술후 심실보조)

  • Kim, Won-Gon;Lee, Chang-Ha;Kim, Ki-Bong;Ahn, Hyuk;Rho, Ryang-Joon
    • Journal of Chest Surgery
    • /
    • v.29 no.11
    • /
    • pp.1218-1222
    • /
    • 1996
  • The reported incidence of postcardiotomy cardiogenic shock not responding to conventional therapy is still 0.1 to 0.8%. For this group of patients, more aggressive form of circulatory support must be employed. Centrifugal pumps are a ventricular assist device most commonly used on this purpose, due to low cost and easy availability. Currently, however, clinical experience of centrifugal pumps as a ventricular assist device is rarely reported in Korea. From January 1992 to January 1996, 2986 patients underwent cardiac operations on cardiopulmonary bypass at Seoul National University Hospital. Refractory postcardiotomy cardiac failure requring ventricular support with a Biomedicus centrifugal pump developed in ten of these patients. There were eight men and two women, ranged in age from nine years to 77 years with a mean of 50$\pm$20 years. The primary surgical procedures consisted of isolated coronary revascularization in four patients, combined coronary revascularization and aortic valve replacement in two, aortic dissection repair in two, pulmonary embolectomy in one, and heart transplantation in one. Of the ten patients, five had left ventricular assistance, one had right ventricular assistance, and four had biventricular assistance. Duration of ventricular assistance ranged from 24 to 175 hours, with a mean of 76$\pm$51 hours. Seven patients were weaned from ventricular assistance, and four of them discharged. The causes of death for nonsurvivors were progressive cardiac failure in two patients and multiorgan failure, intractable ventricular fibrillation, irreversible brain injury, and mechanical problem, respectively, in the other four. Survival was not predicted by time on cardiopulmonary bypass, aortic cross-clamp time, or duration of ventricular support. Major complications included bleeding(7), renal failure(6), infection(3) and neurologic complication(2). These results indicate that a centrifugal pump can provide reasonably satisfactory short-term circulatory support.

  • PDF

Bidirectional Cavopulmonary Shunt for Isolated Right Ventricular Endomyocardial Fibrosis (우심실에 생긴 심근내막섬유증에서 시행한 양 방향성 상대정맥-폐동맥 단락 수술)

  • 서영준;이덕헌;박남희;최세영;유영선
    • Journal of Chest Surgery
    • /
    • v.36 no.7
    • /
    • pp.523-526
    • /
    • 2003
  • A 44-year-old man had been admitted for dyspnea on exertion and abdominal distension. The echocardiography revealed abnormal mass in right atrium and tricuspid valve stenosis with right ventricular obliteration. The operation was performed with mass removal, enlargement of tricuspid valve opening, and right ventricular endocardiectormy. And then, atrial septal defect was made due to inadequate right ventricular volume. The patient's symptom was improved and he discharged without events. The endomyocardial fibrosis was diagnosed with microscopic examination. Eighteen months later, the patient was readmitted due to aggravated dyspnea and cyanosis. The right ventricular obliteration was progressed and pulmonary blood flow was severely decreased in follow up echocardiography. Palliative bidirectional cave-pulmonary shunt was performed due to functional single ventricle. The dyspnea and cyanosis was markedly improved. Bidirectional cavo-pulmonary shunt for advanced and isolated right ventricular endomyocardial fibrosis provided effective palliation at early postoperative period, However, long-term follow up is mandatory.

Infective Endocarditis Involving Aortic Valve, Mitral Valve, Tricuspid Valve, and luterventricular Septum -A Case Report (대동맥판막, 승모판막, 삼첨판막과 심실중격을 침범한 심내막염 -1예 보고-)

  • 박종빈;서동만
    • Journal of Chest Surgery
    • /
    • v.30 no.2
    • /
    • pp.200-204
    • /
    • 1997
  • This is a report of a successful management of a patient with infective endocarditis involving native aortic valve, mitral valve, tricuspid valve, and Interventric lar septum. A 16 year-old patient who underwent VSD patch closure, and aortic valvuloplasty at the age of 1 1 years showed Intractable congestive heart failure during antibiotics treatment for infective endocarditis. Operative findings revealed that there were large defect along the previous patch, aortic regurgitation with multiple perforations and vegetations, mitral regurgitation with vegetation, aortic paraannular abscess, interventricular myocardial abscess, and tricuspid regurgitation with perforations and vegetations. We reconstructed the interventricular defect with Dacron patch extending to the aortic valve annulus after radical debridement of all infected or devitalized tissues, and could implant aortic valve by anchoring to the reconstructed Dacron patch. Mitral valve was replaced and tricuspid valve was repaired with patient's own pericardium. The patient was discharged after antibiotics treatment for 6 weeks and in good condition without any sequelae for 12 months.

  • PDF

An Animal Study on Electrohydraulic Type Ventricular Assist Device (전기 유압식 심실보조장치의 동물실험 연구)

  • 백완기;심상석
    • Journal of Chest Surgery
    • /
    • v.29 no.7
    • /
    • pp.689-699
    • /
    • 1996
  • An animal experiment was designed for the evaluation of in vivo performance of the newly developed electrohydraulic type ventricular assist device and its influence on the left ventricular function during pal- satile left ventricular assist. Eight adult sheep were incorporated into the study and data were collected from seven sheep. Total as- sist time ranged from 69 minutes to 7 days. The performance of the device was satisfactory both in asyn- chr nous and synchronous mode within the range of given native heart rate. More than 4 liters of device output could be reached within the range of normal left atral pressure without development of negative pressure in the left atrium. Moderate to severe degree of hemolysis was noted as evidenced by significant increase of plasma free hemoglobin level after 3 days of left ventricular support along with the presence of the small amount of thrombi around the floating disc type polymer valve apparatus reflecting that further study and refinement of the device need to be done in regard of biocompatibility and thromboresistance. The hemodynamics showed increase in heart rate (p < 0.05), cardiac output and left ventricular minute work (p < 0.05) after placement of the device at the flow rate of 2.0∼2.5 Llmin. The left atrial pressure, left ventricular pressure and LV dpldt were decreased after the device placement(p < 0.05). The endocardial viability ratio and oxygen contents of the mixed ven us blood and coronary venous blood were all increased (p < 0.05) after the device placement suggesting effective unloading of the left ventricle was accomplished. The myocardial perfusion was thought improved in synchronous counterpulsation as suggested by sig- nificant increase in endocardial viability ratio and coronary venous blood oxygen content in synchronous assist mode comparing with asynchronous mode.

  • PDF

Post-Infarction Ventricular Septal Rupture : 10 Years of Experience (급성 심근경색증 후 심실중격 결손: 10년 경험)

  • Jung, Yo-Chun;Cho, Kwang-Ree;Kim, Ki-Bong
    • Journal of Chest Surgery
    • /
    • v.40 no.5 s.274
    • /
    • pp.351-355
    • /
    • 2007
  • Background: Postinfarction ventricular septal rupture is associated with mortality as high as $85\sim90%$, if it is treated medically. This report documents our experience with postinfarction ventricular septal rupture that was treated surgically, Material and Method: We retrospectively reviewed the medical records of 11 patients who were operated on due to postinfarction ventricular septal rupture between August 1996 and August 2006. There were 4 men and 7 women, with a mean age of $70{\pm}11$ years (age range: $50\sim84$ years). The location of the rupture was anterior in 7 cases and posterior in 4 cases. The interval between the onset of acute myocardial infarction and the occurrence of the ventricular septal rupture was $2.0{\pm}1.3$ days (range: $1\sim5$ days). Operation was performed at an average of $2.4{\pm}2.7$ days (range: $0\sim8$ days) after the diagnosis of septal rupture. Preoperative intraaortic balloon pump therapy was performed in 10 patients. Result: The infarct exclusion technique was used in all cases. Coronary artery bypass grafting was done in 8 cases, with the mean number of distal anastomosis being $1.0{\pm}0.8$. There was one operative death. In 2 patients, reoperation was performed due to a residual septal defect. The postoperative morbidities were transient atrial fibrillation (n=7), paroxysmal supraventricular tachycardia (n=1), low cardiac output syndrome (n=3), bleeding reoperation (n=2), delayed sternal closure (n=2), acute renal failure (n=2), pneumonia (n=1), intraaortic balloon pump-related thromboembolism (n=1), and transient delirium (n=2). Nine patients have been followed up for a mean of $38{\pm}40$ months except for one follow-up loss. There have been 3 late deaths. At the latest follow-up, all 6 survivors were in a good functional class. Conclusion: We demonstrated satisfactory operative and midterm results with our strategy of preoperative intraaortic balloon pump therapy, early repair of septal rupture by infarct exclusion and combined coronary revascularization.

Primary Surgical Closure of Large Ventricular Septal Defects in Small Infants (조기 영아기 심실 중격 결손의 개심술)

  • 최종범;양현웅
    • Journal of Chest Surgery
    • /
    • v.30 no.5
    • /
    • pp.486-492
    • /
    • 1997
  • We r viewed a policy of primary surgical closure of large ventricular septal defects in small infants. Sixty-three infants met criteria for inclusion in the study, and were divided into two groups based on age: group 1 infants aged less than 5 months(n = 31), and group 2 infants aged 5 months or more(n = 32). Both groups had similar variation in ventricular septal defect location(paramembranous versus muscular), and showed no significant difference in left to right shunt and in ratio of systemic and pulmonary vascualr resistance. Three early deaths(9.7%) occurred in group 1, but no death(0%) in group 2. The causes of death were preoperative cardiac arrest and cerebral injury followed by postoperative respiratory insufficiency in two patients, and preoperative tracheomalacia followed by laryngeal edema and respiratory arrest in one Two patients in group 1 showed postoperative low cardiac output syndrome(6.5% in group 1 versus 0% in group 2). There was no late death during the follow-up per od in both groups. No surviving patients had postoperative patch leakage, or required a second operation. These results indicate that primary surgical closure of large ventricular septal defects, if logical perioperative care is accompanied, can be saefly performed in small infants aged less than 5 months with low postoperative mortality or morbidity rates.

  • PDF

A Thrombus within an Interventricular Membranous Septal Aneurysm Leading to Cerebral Infarction: A Case Report (심실간 막 중격류에 생긴 혈전으로 인한 뇌경색: 증례 보고)

  • Seongken Kim;Joon-Won Kang;Hyun Jung Koo;Dong Hyun Yang
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.1
    • /
    • pp.210-214
    • /
    • 2024
  • Interventricular membranous septal aneurysms are rare. Since these aneurysms can lead to complications such as obstruction of right ventricular outflow and thromboembolism, the detection of this aneurysm has clinical significance. Herein, we report a case of an interventricular membranous septal aneurysm with an internal thrombus thought to be the cause of a cerebral infarction.