• Title/Summary/Keyword: 심부체온

Search Result 24, Processing Time 0.017 seconds

Accuracy Evaluation of Bi-medium Deep Body Thermometer Based on Finite Element Simulation (유한 요소 시뮬레이션을 이용한 이중 매질 심부 체온계의 정확도 평가)

  • Sim, S.Y.;Ryou, H.S.;Kim, H.B.;Jeong, J.H.;Lee, S.J.;Kim, S.M.;Park, Kwang Suk
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.5
    • /
    • pp.160-168
    • /
    • 2014
  • Continuous body temperature monitoring is useful and essential in diverse medical procedures such as infection onset detection, therapeutic hypothermia, circadian rhythm monitoring, sleep disorder assessment, and gynecological research. However, the existing thermometers are too invasive or intrusive to be applied to long-term body temperature monitoring. In our previous study, we invented the bi-medium deep body thermometer which can noninvasively and continuously monitor deep tissue temperature. And the ratio of thermal resistances expressed as K-value should be obtained to estimate body temperature with the thermometer and it can be different under various measurement environments. Although the device was proven to be useful through preliminary simulation test and small group of human study, the experimental environment was restrictive in our previous approach. In this study, a finite element simulation was executed to obtain the K-value and evaluate the accuracy of bi-medium thermometer under various measurement environments. In addition, K-value estimation equation was developed by analyzing the influence of 5 measurement environmental factors (medium length, medium height, tissue depth, blood perfusion rate, and ambient temperature) on K-value. The results revealed that the estimation accuracy of bi-medium deep body thermometer based on computer simulation was very high (RMSE < $0.003^{\circ}C$) in various measurement environments. Also, bi-medium deep body thermometer based on K-value estimation equation showed relatively accurate results (RMSE < $0.3^{\circ}C$) except for one case. Although the K-value estimation technology should be improved for more accurate body temperature estimation, the results of finite element simulation showed that bi-medium deep body thermometer could accurately measure various tissue temperatures under diverse environments.

The Clinical Outcome of Pulmonary Thromboendarterectomy for the Treatment of Chronic Pulmonary Thromboembolism (만성 폐동맥 색전증 환자에서의 폐동맥 내막절제술의 임상적 결과)

  • Bang, Jeong-Hee;Woo, Jong-Soo;Choi, Pil-Jo;Jo, Gwang-Jo;Park, Kwon-Jae;Kim, Si-Ho;Yie, Kil-Soo
    • Journal of Chest Surgery
    • /
    • v.43 no.3
    • /
    • pp.254-259
    • /
    • 2010
  • Background: Diagnosing chronic pulmonary embolism at an early stage is difficult because of the patient’s nonspecific symptoms. This condition is not prevalent in Korea, and in fact, there have been only a few case reports on this in the Korean medical literature. We analyzed the surgical outcome of performing pulmonary thromboendarterectomy in patients with chronic pulmonary embolism. Material and Method: The study subjects included those patients who underwent surgery for chronic pulmonary embolism from 1996 to 2008. For making the diagnosis, echocardiography, chest CT and a pulmonary perfusion scan were performed on the patients who complained of chronic dyspnea. Result: Pulmonary endarterectomy was performed as follows: by incision via a mid-sternal approach (7 patients); by incision via a left posterolateral approach (1 patient); using the deep hypothermic circulatory arrest technique (4 patients); under ventricular fibrillation (3 patients); and under cardioplegic arrest (1 patient). The postoperative systolic pulmonary artery blood pressure significantly decreased from a preoperative value of $78.9{\pm}14.5\;mmHg$ to $45.6{\pm}17.6\;mmHg$ postoperatively (p=0.000). The degree of tricuspid regurgitation was less than grade II after surgery. Two patients died early on, including one patient who had persistent pulmonary hypertension without improvement and right heart failure. Conclusion: Patients who have chronic pulmonary embolism are known to have a poor prognosis. However, we think that early surgical treatment along with making the proper diagnosis before the aggravation of right heart failure can help improve the quality of a patient's life.

Clinical Analysis of the Recent Results of Coronary Artery Bypass Grafting (관상동맥 우회술의 최근성적에 대한 임상적 고찰)

  • Han, Sung-Ho;Kim, Hyuck;Lee, Chul-Bum;Chung, Won-Sang;Jee, Heng-Ok;Kang, Jung-Ho;Kim, Young-Hak
    • Journal of Chest Surgery
    • /
    • v.35 no.7
    • /
    • pp.523-529
    • /
    • 2002
  • Background: Previous reports present that the early results of coronary artery bypass grafting (CABG) has been improving with the accumulation of surgical experience. We conducted a retrospective analysis of the patients who received CABG to evaluate the recent results of CABG. Material and Method: Between January 1996 and August 2001, 154 patients underwent CABG at Hanyang University Hospital. There were 47 patients(group I) who were operated between 1996 and 1998, and 107 patients(group II) who were operated thereafter. The preoperative diagnosis, operative procedure, mortality, and complications were analyzed retrospectively. Result: There were 35 males and 12 females in group I, and 78 males and 29 females in group II, which shows similar ratio of sexes between the two groups. The average age of patients for group I and group II was $55.9{\pm}6.2$ years and $61.0{\pm}8.0$ years, respectively, showing a significant increase in group II(p<0.05). The average left ventricular ejection fraction(LVEF) for group I and group II was $54.6{\pm}11.8$% and $56.9{\pm}13.0$%, respectively. The number of patients who had previous MI in group I and group II were 13 patients(27.7%) and 14 patients(13.1%), respectively, which shows a significant difference (p<0.05). All procedures were performed using the cardiopulmonary bypass(CPB) and moderate systemic hypothermia. Myocardial protection was achieved using intermittent hypothermic ischemia under ventricular fibrillation state or cold crystalloid cardioplegic solution for most of group I patients, whereas cold blood cardioplegic solution was used for group II patients. The mean CPB times for group I and group II were $149.2{\pm}48.7$ minutes and $113.1{\pm}30.6$ minutes, respectively. The mean aortic cross clamp times for group I and group II were $81.3{\pm}26.5$ minutes $72.2{\pm}23.9$ minutes, respectively. These figures show that CPB and aortic cross clamp times were significantly reduced in group II(p<0.05). The use of the left internal thoracic artery(LITA) was increased from 42%(20/47) for group I to 81% (87/107) for group II. The mean number of grafts also significantly increased from $2.5{\pm}0.6$ for group I to $3.0{\pm}1.1$ for group II(p<0.05). Intra-aortic balloon pump(IABP) was applied in 7 cases in group I and 17 cases in group II. Of these, 28.6%(2/7) and 52.9%(9/17) were broadly applied preoperatively in patients with LVEF<40% or congestive heart failure. The operative mortalities for group I and II were 10.6%(5/47) and 0.9%(1/107), respectively, which shows significant decrease for group II(p.0.05). Conclusion: This report suggest that CABG using CPB can recently be performed more safely in virtue of the accumulation of surgical experience with reduction in CPB and aortic cross clamp times and improved surgical techniques and myocardial protection. And we think that the optimal treatment of patients with left ventricular dysfunction associated with congestive heart failure and the extended application of IABP, especially have contributed to the reduction of operative mortality and morbidity.

Studies on the Storage Stability of Traditional Andong sikhe using Lactobacillus delbreuckii (Lactobacillus delbreuckii를 이용한 전통안동식혜의 저장 안정성)

  • Choi, Cheong;Son, Gyu-Mok;Woo, He-Sob
    • Journal of the Korean Society of Food Culture
    • /
    • v.7 no.4
    • /
    • pp.329-338
    • /
    • 1992
  • This study was attempted aimed to prepare of Andong sikhe by pure culture inoculation and to improve storage stability by the addition of stabilizers to the product. Lactobacillus delbreuckii was selected for pure culture inoculation in the fermentation. The effect of stabilizers on the sedimentation, sensory evaluation and viscosity of Sikhe were investigated during the fermentation of traditional Andong Sikhe stored at $4^{\circ}C$ Morphological characteristics of Sikhe were determined by scanning electromicrograpy. Among the stabilizers added to the traditional Andong sikhe Na-alginate was found to be best stabilizers. When the product was evaluated by the sensory panel, the addition of stabilizers up to 0.1% level actually increased the acceptability of the product, while the concentration of more than 0.2% stabilizers affected the acceptability of the negatively. Sikhe added Na-carboxymethyl cellulose and Na-alginate showed highest viscosity on the 2nd day of fermentation, while homogenized Andong sikhe with Carrageenan showed the highest peak in viscosity on the first day of fermentation. Lactic acid bacterial count reached to $3.2{\times}10^8/ml$ after 20 days of storage. The surface and cross section of rice was observed by scanning electron microscope. As the fermentation proceeded holes on the surface increased, and nearly empty cell wall remained at the later stage of fermentation. Use of pure cultured inoculum of L. delbreuckii supported the rapid build up of the lactic acid bacteria and consequently the whole process of the fermentation was shortened. The acceptability and product quality were improved by use of L. delbreuckii inoculum.

  • PDF