• Title/Summary/Keyword: 심박 분류

Search Result 103, Processing Time 0.02 seconds

Coronary Artery Bypass Graft in Patient with Advanced Left Ventricular Dysfunction (중등도 이상의 좌심실 기능 부전 환자에서의 관상동 우회술의 임상 분석)

  • 정종필;김승우;신제균
    • Journal of Chest Surgery
    • /
    • v.34 no.12
    • /
    • pp.901-908
    • /
    • 2001
  • Background : Coronary artery bypass graft(CABG) in patients with advanced left ventricular dysfunction has often been regarded as having high mortality rate, despite the great improvement in operative result of CABG. With recent advances in surgical technique and myocardial protection, surgical revascularization improved the symptom and long-term survival of these high risk patients more than the medical conservative treatment. Material and Methold : Clinical data of 31(4.1%) patients with preoperative ejection fraction less than 30% among 864 CABGs performed between January 1995 and March 1999 were retrospectively analyzed and pre- and postoperative changes of the ejection fraction on echocardiography were analyzed. There were 26 men and 5 women. The mean age was 60.7 years(range 41 to 72 years). History of myocardial infarction(30 cases, 98%) was the most common preoperative risk factor. There were seven irreversible myocardial infarction on thallium scan. Most patients had triple vessel diseases(26 cases, 84%) and first degree of Rentrop classification(16 cases, 52%) on coronary angiography. The mean number of distal anastomosis during CABG was per patient was 4.9${\pm}$0.8 sites in each patient. In addition to long saphenous veins, the internal mammary artery was used in 20 patients. Total bypass time was 244.7${\pm}$3.7 minutes(range, 117 to 567 minutes), and mean aortic cross-clamp time was 77.9 ${\pm}$ 1.6 minutes(range, 30 to 178 minutes). There were five other reparative procedures such as two left ventricular aneurysrmectomy, two mitral repair, and one aortic valve replacement. There were twelve postoperative complications such as three cardiac arrhythmia, two bleeding(re-operation), one delayed sternal closure, eleven usage of intra-aortic balloon counterpulsation for low cardiac output. Two patients died, postoperative mortality was 6.5% . Twenty-nine patients were relieved of chest pain and left ventricular ejection fraction after operation was significantly higher(38.5${\pm}$11.6%, p 0.001) as compared with preoperative left ventricular ejection fraction(25.3${\pm}$2.3%). The follow up period of out patient was 25. 3 months. Conclusion: In patients with coronary artery disease and advanced left ventricular dysfunction, coronary artery bypass grafting can be performed relatively safely with improvement in left ventricular function, but it will be necessary to study long term results.

  • PDF

Early and Mid-term Results of Operation for Infective Endocarditis on Mitral Valve (감염성 승모판 심내막염의 중단기 수술 성적)

  • Ahn, Byong-Hee;Chun, Joon-Kyung;Yu, Ung;Ryu, Sang-Wan;Choi, Yong-Sun;Kim, Byong-Pyo;Hong, Sung-Bum;Bum, Min-Sun;Na, Kook-Ju;Park, Jong-Chun;Kim, Sang-Hyung
    • Journal of Chest Surgery
    • /
    • v.37 no.1
    • /
    • pp.27-34
    • /
    • 2004
  • Background: Infective endocarditis shows higher operative morbidity and mortality rates than other cardiac diseases. The vast majority of studies on infective endocarditis have been made on aortic endocarditis, with little attention having been paid to infective endocarditis on the mitral valve. This study attempts to investigate the clinical aspects and operative results of infective endocarditis on the mitral valve. Meterial and Method: The subjects of this study consist of 23 patients who underwent operations for infective endocariditis on the mitral valve from June 1995 to May 2003. Among them, 2 patients suffered from prosthetic valvular endocarditis and the other 21 from native valvular endocarditis. The subjects were evenly distributed age-wise with an average age of 44.8$\pm$15.7 (11∼66) years. Emergency operations were performed on seventeen patients (73.9%) due to large vegetation or instable hemodynamic status. In preoperative examinations, twelve patients exhibited congestive heart failure, four patients renal failure, two patients spleen and renal infarction, and two patients temporary neurological defects, while one patient had a brain abscess. Based on the NYHA functional classification, seven patients were determined to be at Grade II, 9 patients at Grade III, and 6 patients at Grade IV. Vegetations were detected in 20 patients while mitral regurgitation was dominant in 19 patients with 4 patients showing up as mitral stenosis dominant on the preoperative echocardiogram. Blood cultures for causative organisms were performed on all patients, and positive results were obtained from ten patients, with five cases of Streptococcus viridance, two cases of methicillin-sensitive Staphylococcus aureus, and one case each of Corynebacteriurn, Haemophillis, and Gernella. Operations were decided according to the AA/AHA guidelines (1988). The mean follow-up period was 27.6 $\pm$23.3 (1 ∼ 97) months. Result: Mitral valve replacements were performed on 43 patients, with mechanical valves being used on 9 patients and tissue valves on the other 4. Several kinds of mitral valve repair or mitral valvuloplasty were carried out on the remaining 10 patients. Associated procedures included six aortic valve replacements, two tricuspid annuloplasty, one modified Maze operation, and one direct closure of a ventricular septal defect. Postoperative complications included two cases of bleeding and one case each of mediastinitis, low cardiac output syndrome, and pneumonia. There were no cases of early deaths, or death within 30 days following the operation. No patient died in the hospital or experienced valve related complications. One patient, however, underwent mitral valvuloplasty 3 months after the operation. Another patient died from intra-cranial hemorrhage in the 31st month after the operation. Therefore, the valve-related death rate was 4.3%, and the valve-related complication rate 8.6% on mid-term follow-up. 1, 3-, and 5-year valve- related event free rates were 90.8%, 79.5%, and 79.5%, respectively, while 1, follow-up. 1, 3-, and 5-year valve- related event free rates were 90.8%, 79.5%, and 79.5%, respectively, while 1, 3-, and 5-year survival rates were 100%, 88.8%, and 88.8%, respectively. Conclusion: The findings suggest that a complete removal of infected tissues is essential in the operative treatment of infectious endocarditis of the mitral valve. It is also suggested that when infected tissues are completely removed, neither type of material nor method of operation has a significant effect on the operation result. The postoperative results also suggest the need for a close follow-up observation of the patients suspected of having brain damage, which is caused by preoperative blood contamination or emboli from vegetation, for a possible cerebral vascular injury such as mycotic aneurysm.

Medical Information Dynamic Access System in Smart Mobile Environments (스마트 모바일 환경에서 의료정보 동적접근 시스템)

  • Jeong, Chang Won;Kim, Woo Hong;Yoon, Kwon Ha;Joo, Su Chong
    • Journal of Internet Computing and Services
    • /
    • v.16 no.1
    • /
    • pp.47-55
    • /
    • 2015
  • Recently, the environment of a hospital information system is a trend to combine various SMART technologies. Accordingly, various smart devices, such as a smart phone, Tablet PC is utilized in the medical information system. Also, these environments consist of various applications executing on heterogeneous sensors, devices, systems and networks. In these hospital information system environment, applying a security service by traditional access control method cause a problems. Most of the existing security system uses the access control list structure. It is only permitted access defined by an access control matrix such as client name, service object method name. The major problem with the static approach cannot quickly adapt to changed situations. Hence, we needs to new security mechanisms which provides more flexible and can be easily adapted to various environments with very different security requirements. In addition, for addressing the changing of service medical treatment of the patient, the researching is needed. In this paper, we suggest a dynamic approach to medical information systems in smart mobile environments. We focus on how to access medical information systems according to dynamic access control methods based on the existence of the hospital's information system environments. The physical environments consist of a mobile x-ray imaging devices, dedicated mobile/general smart devices, PACS, EMR server and authorization server. The software environment was developed based on the .Net Framework for synchronization and monitoring services based on mobile X-ray imaging equipment Windows7 OS. And dedicated a smart device application, we implemented a dynamic access services through JSP and Java SDK is based on the Android OS. PACS and mobile X-ray image devices in hospital, medical information between the dedicated smart devices are based on the DICOM medical image standard information. In addition, EMR information is based on H7. In order to providing dynamic access control service, we classify the context of the patients according to conditions of bio-information such as oxygen saturation, heart rate, BP and body temperature etc. It shows event trace diagrams which divided into two parts like general situation, emergency situation. And, we designed the dynamic approach of the medical care information by authentication method. The authentication Information are contained ID/PWD, the roles, position and working hours, emergency certification codes for emergency patients. General situations of dynamic access control method may have access to medical information by the value of the authentication information. In the case of an emergency, was to have access to medical information by an emergency code, without the authentication information. And, we constructed the medical information integration database scheme that is consist medical information, patient, medical staff and medical image information according to medical information standards.y Finally, we show the usefulness of the dynamic access application service based on the smart devices for execution results of the proposed system according to patient contexts such as general and emergency situation. Especially, the proposed systems are providing effective medical information services with smart devices in emergency situation by dynamic access control methods. As results, we expect the proposed systems to be useful for u-hospital information systems and services.