• Title/Summary/Keyword: 심박출계수

Search Result 37, Processing Time 0.02 seconds

Comparison of the Ejection Fraction Between Gated Blood Pool, Gated Blood Pool SPECT and Echocardiography (게이트심장혈액풀스캔과 게이트심장혈액풀 SPECT로 측정한 심박출계수의 심초음파와의 비교 연구)

  • Jeong, Ji-Uk;Lee, Hyo-Yeong;Yun, Jong-Jun;Lee, Hwa-Jin;Lee, Moo-Seok;Song, Hyeon-Seok;Park, Se-Yun;Kim, Jae-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.150-154
    • /
    • 2010
  • Purpose: Ejection fraction (EF) is one of the most important factors that evaluate heart function. Recently, according to echocardiography and myocardial perfusion SPECT, the number of gated blood pool scan (planar GBP) is declining. Measurement of left ventricular ejection fraction using gated blood pool SPECT (GBPS) is known as relatively correspond with echocardiography. We compared EF derived from plnar GBP, GBPS and echocadiography using modified simpson method to determine the accuracy. Materials and Methods: From January 2007 to June 2010, planar GBP and GBPS were performed on 34 patients who admitted to Pusan National University Hospital (men 23, women 11, mean age $52.6{\pm}27.2$). Each patient was injected with $^{99m}{TcO_4}^-$ of 20 mCi after pyrophosphate injection and then scanned using both planar GBP and GBPS techniques. For image analysis, we use ADAC Laboratories, Ver. 4.20 software. The result analyzed was processed by SPSS 17.0 Win statistic program and statistical method applied in data analysis is one-way anova, Tukey's post hoc test, pearson correlation test. Results: One-way anova test show no significant difference (planar GBP $56.3{\pm}13.9%$; GBPS $60.4{\pm}16.0%$; echocardiography $59.1{\pm}14.4%$, p=0.486, p>0.05). Tukey's post hoc test show no significant difference (planar GBP-echocardiography p=0.697; GBPS-echocardiography p=0.928; planar GBP-GBPS p=0.469, p>0.05). Values for EF obtained with planar GBP and GBPS correlated well with those obtained with echocardiography (planar-echocardiography r=0.697; GBPS-echocardiography r=0.928; planar GBP-GBPS r=0.469). Conclusion: The problems of accuracy and reproducibility for planar GBP still remain. But planar GBP is a safe and non-invasive method. In addition, planar GBP is useful to evaluate patient with low resolution echocardiography images. GBPS is not appicated clinically. but GBPS can be obtain various left ventricular functional parameters. planar GBP, GBPS and echocardiography show a good correlation between each other. Therefore, planar GBP and GBPS are useful for evaluating left ventricular ejection fraction.

  • PDF

The Study on the Correlation of the Ejection Fraction of Multi Gated Blood Pool Scan and Echocardiography According to the Condition of Cardiac Function (심장기능상태의 분류에 따른 게이트심장혈액풀 검사와 심장초음파의 심박출계수 상관관계에 관한 고찰)

  • Lee, Dong Hun;Park, Jang Won;Nam, Ki Pyo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.57-61
    • /
    • 2015
  • Purpose We considered the correlation of Ejection Fraction (EF) which was analyzed by Multi Gated Blood Pool Scan (MUGA) and Echocardiography (ECHO) for the patients who were classified according to the condition of cardiac function. Materials and Methods We analyzed the patients (female 60) who were diagnosed with breast cancer and were examined by both MUGA and ECHO. The 30 patients (age: $58.27{\pm}13.48$) who were analyzed into less than 50% to 70% of EF were categorized as normal group and the other 30 patients (age: $53.70{\pm}8.45$) who were analyzed into less than 50% of EF were categorized as abnormal group. Statistical analysis with SPSS ver. 18 was applied. Results Each of the value of mean and standard deviation of normal group was $66.43{\pm}5.80$ (MUGA), $60.50{\pm}4.93$ (ECHO). There was a significant difference (p<0.001). Each of the value of mean and standard deviation of abnormal group was $41.93{\pm}7.58$ (MUGA), $41.70{\pm}11.49$ (ECHO). There was no significant difference (p>0.001). In the result, all 30 cases of normal group showed the same reading. 8 out of 30 cases in abnormal group showed inconsistency of the reading. Conclusion We could confirm the correlation of the EF in MUGA and ECHO statistically. There was difference between abnormal groups from the result of reading. If we are aware of the result according to the different cardiac function categorization, MUGA and ECHO can be used as even more accurate interchangeable test.

  • PDF

Study the Analysis of Comparison with AROI and MROI Mode in Gated Cardiac Blood Pool Scan (게이트심장혈액풀 스캔에서 자동 관심영역 설정과 수동 관심영역 설정 모드의 비교 분석에 관한 고찰)

  • Kim, Jung-Yul;Kang, Chun-Koo;Kim, Yung-Jae;Park, Hoon-Hee;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.222-228
    • /
    • 2008
  • Purpose: The objectives of this study were to compare the left ventricle ejection fraction (LVEF) from gated cardiac blood pool scan (GCBP) for analysis auto-drawing region of interest mode (AROI) and manual-drawing region of interest mode (MROI), respectively. To evaluation the relationships between values produced by both ROI modes. Materials and Methods: Gated cardiac blood pool scan using in vivo method Tc-99m Red Blood Cell were performed for 33 patients (mean age: $53.2{\pm}13.2\;y$) with objective of chemotherapy using single head gamma camera (ADAC Laboratories, Milpitas, CA). Left ventricular ejection fraction was automatically and manually measured, respectively. Results: There was significant difference statistically between AROI and MROI ($LVEF^{AROI}$: $71.4{\pm}12.4%$ vs. $LVEF^{MROI}$: $65.8{\pm}5.9%$, p=0.003). Intra-observer agreements in AROI was higher than MROI ($\gamma^{AROI}=0.964$, Cronbach's $\alpha^{AROI}=0.986$ vs. $\gamma^{MROI}=0.793$, Cronbach's $\alpha^{MROI}=0.911$), either. Additionally, there was no significant difference statistically at best septal view (${\Delta}LVEF^{BSV}=0.7{\pm}2.3%$, p=0.233), however statistically significant difference was found at badly separated septal view (${\Delta}LVEF=10.9{\pm}11.4%$, p=0.001). Moreover, Intra-observer agreements in best septal view was higher than badly separated septal view ($\gamma^{BSV}=0.939$, Cronbach's $\alpha^{BSV}=0.978$; $\gamma=0.948$, Cronbach's $\alpha=0.981$ at AROI, $\gamma^{BSV}=0.836$, Cronbach's $\alpha^{BSV}=0.936$; $\gamma=0.748$, Cronbach's $\alpha=0.888$ at MROI). Conclusion: When best septal view was acquired, LVEF by AROI and MROI indicated not different. Comparing Intra-observer agreements with AROI and MROI, the AROI tended to show higher. Therefore, it is considered that the AROI than MROI is valuable in reproducibility and objective when ROI analysis by acquire left ventricular of best septal view.

  • PDF

Endoventricular Circular Patch Plasty (Dor Procedure) for Ischemic Left Ventricular Dysfunction (허혈성 좌심실 부전증에서의 좌심실내 원형 패취성형술)

  • Cho, Kwang-Ree;Lim, Cheong;Choi, Jae-Sung;Hong, Jang-Mee;Kim, Hyeong-Ryul;Kim, Ki-Bong
    • Journal of Chest Surgery
    • /
    • v.37 no.9
    • /
    • pp.755-761
    • /
    • 2004
  • We evaluated the efficacy of Dor procedure in patients with ischemic left ventricular dysfunction. Material and Method: Between April 1998 and December 2002, 45 patients underwent the Dor procedure con-comitant with coronary artery bypass grafting (CABG). Left ventricular ejection fraction (LVEF) and left ventricular end-diastolic/end-systolic volumes (LVEDV/LVESV) were measured by echocardiography, myocardial SPECT, and cardiac catheterization and angiography performed at the sequence of preoperative, early postoperative, and one year postoperative stage. Result: Cardiopulmonary bypass and aortic clamp times were mean 141$\pm$64, 69$\pm$24 minutes, respectively. Intraaortic balloon pump (IABP) therapy was required in 19 patients (42%; 7 preoperatively, 9 intraoperatively, 3 postoperatively). Operative mortality rate was 2.2% (1/45). Postoperative morbidities were low cardiac output syndrome (12), atrial fibrillation (5), acute renal failure (4), and postoperative bleeding (4). Functional class (NYHA) was improved from classes 2.8 to 1.1 (p < 0,01). When we compared between the preoperative and early postoperative values, LVEF was improved from 32$\pm$9% to 52$\pm$11% (p<0.01). The asynergy portion decreased from 57$\pm$12% to 22$\pm$9%, and LVEDV/LVESV indexes improved from 125$\pm$39 mL/$m^2$, 85$\pm$30 mL/$m^2$ to 66$\pm$23 mL/$m^2$, 32$\pm$16 mL/$m^2$ (p<0.01). Although these changes in volumes were relatively preserved at postoperative one year, the left ventricular volumes showed a tendency to increase. Conclusion: After the Dor procedure for ischemic left ventricular dysfunction, LVEF improvement and left ventricular volume reduction were maintained till postoperative one year. The tendency for left ventricular volume to increase at postoperative one year suggested the requirement of strict medical management.

Evaluation of Cardiac Ejection Fraction using Cardiac MRI (Cardiac MRI를 이용한 심박출계수의 평가)

  • Eun, Sung-Jong;Kook, Jin-Sun
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.5
    • /
    • pp.289-294
    • /
    • 2011
  • The aim of this study is to evaluate the differences of ejection fraction of left ventricle through the quantitative analysis of diastolic and systolic volumes according to slices selected using cardiac MR imaging. A total of 12 volunteers (7 normal, 1 myocardium bridge, and 4 arrhythmia) underwent cardiac MRI on a MR scanner(Magnetom Trio, Siemens, Germany). Ejection fractions for quantitative analysis were calculated at single slice of center of left ventricle, 3, 5, and 6-7 slices extending from the center of left ventricle. Average values were analyzed for evaluating differences of ejection fraction according to the number of slices selected. Mean value of normal person of ejection fraction were 67.14% at single slice of center of left ventricle, 66.24% at 3 slices, 65.63% at 5 slices, and 65.29% at 6-7 slices. While ejection fraction obtained from a patient with 61.74% at single slice of center of left ventricle, 60.92% at 3 slices, 60.89% at 5 slices, and 61.89% at 6-7 slices. There was no significant differences by the number of slices selected. This study demonstrates that ejection fraction obtained from single slice of center of left ventricle may represent a optimum parameter for cardiac function, instead of the value calculated on the variable slices selected.

Cardiovascular Effects of Free Movement of Abdominal Muscle in Prone Positioning during General Anesthesia (전신마취동안에 복와위시 자유로운 복근 움직임이 심혈관계에 미치는 영향)

  • Kim, Ji-Yoon;Lee, Dong-Won;Seo, Il-Sook;Kim, Sae-Yeon
    • Journal of Yeungnam Medical Science
    • /
    • v.24 no.2
    • /
    • pp.206-215
    • /
    • 2007
  • Background : The prone position is often used for operations involving the spine and provides excellent surgical access. The complications associated with the prone position include ocular and auricular injuries, and musculoskeletal injuries. In particular, the prone position during general anesthesia causes hemodynamic changes. To evaluate the cardiovascular effects of the prone position in surgical patients during general anesthesia, we investigated the effects on hemodynamic change of the prone position with the Jackson spinal surgery table. Materials and Methods : Thirty patients undergoing spine surgery in the prone position were randomly selected. After induction of general anesthesia, intra-arterial and central venous pressures (CVP) were monitored and cardiac output was measured by $NICO^{(R)}$. We measured stroke volume, cardiac index, cardiac output, mean arterial pressure, heart rate, CVP and systemic vascular resistance (SVR) before changing the position. The same measurements were performed after changing to the prone position with the patient on the Jackson spinal surgery table. Results : In the prone position, there was a significant reduction in stroke volume, cardiac index and cardiac output. The heart rate, mean arterial pressure and CVP were also decreased in the prone position but not significantly. However, the SVR was increased significantly. Conclusion : The degree of a reduced cardiac index was less on the Jackson spinal surgery table than other conditions of the prone position. The reduced epidural pressure caused by free abdominal movement may decrease intraoperative blood loss. Therefore, the Jackson spinal surgery table provides a convenient and stable method for maintaining patients in the prone position during spinal surgery.

  • PDF