• Title/Summary/Keyword: 심박동

Search Result 159, Processing Time 0.03 seconds

Asymmetric Activation in the Prefrontal Cortex and Heart Rate Variability by Sound-induced Affects (음향감성에 의한 전전두엽의 비대칭성과 심박동변이도)

  • Jang Eun-Hye;Lee Ji-Hye;Lee Sang-Tae;Kim Wuon-Shik
    • Science of Emotion and Sensibility
    • /
    • v.8 no.1
    • /
    • pp.47-54
    • /
    • 2005
  • This study is aimed to inspect how the different sensitivities in Behavioral activation system(BAS) and behavioral inhibition system(BIS) modulate on the properties of physiological responses stimulated by positive or negative affective sound. We measured the electroencephalogram(EEG) and electrocardiogram (ECG) of 32 students, consisted of four groups depending on the BAS and BIS sensitivities, during listening to meditation music or noise. The EEG was recorded at Fpl and Fp2 sites and Power spectral density(PSD) of HRV was derived from the ECG, and the power of HRV was calculated for 3 major frequency ranges(low frequency[LF], medium frequency and high frequency[HF]). After listening to music or noise, subjects reported the affect induced by the sound. For EEG, the power in the alpha band at Fp2, especially in the alpha-2 band(9.0-11.0 Hz) increased during the subjects listening to music, while the power at Fpl increased during noise. During listening to meditation music, there is a tendency that the left-sided activation in prefrontal cortex(PFC) is positively correlated with the difference of BAS(Z)-BIS(Z). During listening to noise, there is a tendency that the right-sided activation in PFC is dominant in case any of the sensitivity of BAS or BIS is high. For HRV, we found that the index of MF/(LF+HF), during listening to music, was higher significantly in the individuals with a low BIS but high BAS than in the individuals with a low sensitivity both BIS and BAS individuals. With high BIS, regardless of the BAS sensitivity, the difference of this index values was not significant. From these results we suggest that the physiological responses of different individuals in BAS and BIS react differently under the same emotionally provocative challenge.

  • PDF

Design of Filter to Remove Motion Artifacts of Photoplethysmography Signal Using Adaptive Notch Filter and Fuzzy Inference system (적응 노치필터와 퍼지추론 시스템을 이용한 광용적 맥파 신호의 동잡음 제거 필터 설계)

  • Lee, Ju-Won;Lee, Byeong-Ro
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.20 no.1
    • /
    • pp.45-50
    • /
    • 2019
  • When PPG signal is used in mobile healthcare devices, the accuracy of the measured heartbeat decreases from the influence by the movement of the user. The reason is that the frequency band of the noise overlaps the frequency band of the PPG signal. In order to remove these same noises, the methods using frequency analysis method or application of acceleration sensor have been investigated and showed excellent performance. However, in applying these methods to low-cost healthcare devices, it is difficult to apply these methods because of much processing time and sensor's cost. In order to solve these problems, this study proposed the filter design method using an adaptive notch filter and the fuzzy inference system to extract more accurate heart rate in real time and evaluated its performance. As results, it showed better results than the other methods. Based on the results, when applying the proposed method to design the mobile healthcare device, it is possible to measure the heartbeat more accurately in real time.

Factor Analysis of Decreased Score on Coronary Artery Calcium Score (관상동맥 석회화점수 감소 요인 분석)

  • Shim, Jae-Goo;Kim, Yon-Min;Kim, Jin-Woo
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.4
    • /
    • pp.285-290
    • /
    • 2016
  • The purpose of our study was to retrospectively evaluate the cause of a decreased calcium score of follow-up studies on coronary artery calcium scores (CACs) computed tomography (CT). The subjects were healthy 100 people(85 males $60.6{\pm}6.9$ years, 15 females $67.2{\pm}7.3$ years). The subjects decreased CACs were divided into 4 subgroups depending on Agatston classification, minimal (1-10), mild (11-100), moderate (101-400), severe (400<). As a result of decreased CACs were scan location disagreement 51%, motion artifact 26%, equipment changes 14%, operator mistakes 5%, input miss 2%, image loss 1%, arrhythmia 1%. In the mild group, the most common decreased CACs were 49 people. In the minimal group, the most significant variation reduction has occurred to 6 people. Scan location disagreement was considered a partial volume effects due to the scan starting position. It showed less than 100 CACs a high variation (19.7%) in more than 100 CACs, a lower variation (2.2%), these could be seen that the variation range is different that can be tolerated according to the calcification score. Motion artifact factor was found in 26%, which is so closely related to the preceding tests that affect the higher heart rate like this pulmonary function test, exercise stress test.

Glove Type Heart Rate Monitoring System Using Blood Flow Change (혈류량 변화를 이용한 장갑형 심박수 모니터링 시스템)

  • Han, Yun-Cheol;Noh, Yun-Hong;Jeong, Do-Un
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.503-504
    • /
    • 2017
  • Recently, economic growth in the world has increased interest in healthy life, and the smart health care industry is growing. In the field of smart healthcare, wearable-type biometric information measurement technology has been highlighted due to the importance of IoT technology. The purpose of this study is to develop a wearable heart - rate monitoring system that can be applied to wearable health care and glove - type monitoring that enables convenient monitoring of heart rate during activity. For this purpose, a glove - type wearable health care system was developed and its performance was evaluated. Experimental results showed that the heartbeat monitoring was possible even in the presence of actual daily activities.

  • PDF

Design and Implementation of a Prediction System for Cardiovascular Diseases using PPG (PPG를 이용한 심혈관 질환 예측 시스템의 설계 및 구현)

  • Song, Je-Min;Jin, Gye-Hwan;Seo, Sung-Bo;Park, Jeong-Seok;Lee, Sang-Bock;Ryu, Keun-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.1
    • /
    • pp.19-25
    • /
    • 2011
  • Photoplethysmogram(PPG) is the method to obtain the biomedical signal using the linear relationships between the blood volume for changing the cardiac contraction and relaxation and the amount of light for absorbing the hemoglobin in the blood. In this paper, we proposed the analyzed results which show the heart rate variability and the distribution of heart rate for before and after using PPG. Moreover, this paper designed and implemented the system based on personal computer to predict cardiovascular disease in advance using the analyzed results for the autonomic balance from taking the spectral analysis of heart rate and the state of the blood vessel for analyzing APG(acceleration plethysmogram).

A Study of the Heart Rate Detection Using Variable Threshold Method (가변 기준값을 이용한 심박동 검출 기법에 관한 연구)

  • Kim, Se-Jin;Jeong, Do-Un
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.10a
    • /
    • pp.222-226
    • /
    • 2008
  • 본 논문에서는 장시간 심전도를 측정하더라고 착용의 불편함을 최소화하기 위해 가슴에 착용 가능한 벨트형 심전도 전극을 제작하였다. 그리고 심전도 신호의 검출을 위하여 초저전력 계측시스템을 구현하였으며, Zigbee호환의 무선노드를 이용하여 계측된 심전도 신호를 PC측으로 무선 전송하는 시스템을 구현하였다. 또한 착용을 통해 장시간 심전도 측정이 가능하도록 움직임에 따른 동잡음을 제거하고자 하였으며, 이를 위해 적응 신호처리기법을 사용하였다. 그리고 가변 기준값을 이용하여 보다 정확한 심전도 R피크를 검출하고자 하였다. 구현된 적응신호처리와 R피크검출의 성능을 평가하기 위하여 MIT-BIH 데이터를 이용한 잡음제거성능 및 피크검출 실험을 수행하였으며, 실제 피검자를 대상으로 활동 중 심전도 계측 실험을 통해 구현된 시스템의 성능평가를 수행하였다.

  • PDF

Severity of Obstructive Sleep Apnea and Heart Rate Variability : Detrended Fluctuation Analysis (폐쇄성 수면 무호흡증의 심각도와 심박동 변이율 : 탈경향변동분석)

  • Ju, Gawon;Shin, Chul-Jin;Park, Doo-Heum
    • Korean Journal of Biological Psychiatry
    • /
    • v.16 no.2
    • /
    • pp.69-75
    • /
    • 2009
  • Objectives : The detrended fluctuation analysis is one of the nonlinear methods for the investigation of biological time series. It quantifies the fractal scaling properties and is known to be useful in the evaluation of long-range correlations in time series. The heart rate variability(HRV) of obstructive sleep apnea syndrome (OSAS) patients during nighttime was analyzed by detrended fluctuation analysis to assess its relationship with the severity of the symptoms. Methods : Fifty nine untreated male OSAS patients with moderate to severe symptoms(mean age=45.4${\pm}$11.7 years, apnea-hypopnea index, AHI${\geq}$15) underwent nocturnal polysomnography. Moderate(AHI=15-30, N=22) and severe(AHI>30, N=37) OSAS patients were compared for the indices derived from detrended fluctuation analysis and frequency domain analysis of HRV. Results : In the detrended fluctuation analysis, the alpha values were 0.75${\pm}$0.11 and 0.82${\pm}$0.07 for the severe and the moderate OSAS groups respectively. The difference was significant(p<.01). The alpha value had negative correlation with AHI(r=-.425, p=.001). Negative correlation coefficients were also found in the relationships between the alpha values and very low frequency(VLF)(r=-.425, p=.001), low frequency(LF)(r=-.633, p= <.001) and the LF/HF ratio(r=-.305, p=.019) respectively. LF/HF ratio(p=.005) was higher in the severe OSAS group compared to that of the moderate OSAS group. Conclusion : In this study, the detrended fluctuation analysis showed the significant difference between the two OSAS groups classified according to their severity of symptoms. The scaling exponent showed the negative correlation with AHI and indicies of frequency domain analysis. This result suggests that detrended fluctuation analysis can be helpful to estimate the severity of OSAS.

  • PDF

Effects of Heart Rate Variability after Visiting the Gotjawal Forest in Jeju (제주 곶자왈숲 삼림욕 후에 심박동변이에 미친 영향)

  • Sin, Bangsik;Lee, Hyung H.;Lee, Keun Kwang
    • Journal of Naturopathy
    • /
    • v.7 no.1
    • /
    • pp.1-9
    • /
    • 2018
  • The purpose of this study is to statistically investigate the changes in mean differences of the vascular age types and index, heart beating, vessel elasticity, diastolic reserves contents measured by the fingertip plethysmogram before and after the subjects (49 people) visit the Gotjawal forest for two hours. While there is no significant change in the mean differences of vascular age types and index, heart beating, diastolic reserves contents in the control group before and after the visit, the differences in the test groups gets higher than the control group and shows a significant difference. Moreover, the variance analyses of the mean values of the contents shows a significant change after the visit. There is no significant change in the values of vessel elasticity changes between the groups after the visit, but the change of values is significant in the within group, and it is not significant between group by variance analysis. The differences of the heart beating was insignificant in the within group, but significant between group after the visit. In conclusion this study proves the effects of forest bathing, because the HRV index significantly improved after the bathing. Therefore the b-c-d-e/a ratio may be useful for evaluation of HRV.

  • PDF

Thirteen-year Experience of Permanent Epicardial Pacing in Children (소아연령군에서의 영구 심외막 심박 조율 13년 경험)

  • 한국남;임홍국;김웅한;김용진;노준량;배은정;노정일;윤용수;안규리
    • Journal of Chest Surgery
    • /
    • v.37 no.6
    • /
    • pp.499-503
    • /
    • 2004
  • Background: We investigated the longevity, thresholds of epicardial pacemaker and causes of reoperation in the pediatric patients who underwent epicardial pacemaker implantation performed during the last 13 years Material and Method: 121 operations were performed in 83 patients from January 1989 to July 2002. We analyzed the stimulation threshold, resistance, R-wave and P-wave, and sensitivity of pacemaker lead at initial implantation. Longevity and causes of reoperations were investigated. Result At implantation, epicardial ventricular mean stimula-tion threshold was 1.2$\pm$0.1 (0.1∼5) mV, mean resistance was 519.1$\pm$18.1 (319∼778) Ohm, and mean R-wave sensitivity was 8.9$\pm$0.7 (4∼20) mV, and mean P wave sensivity was 2.5$\pm$0.7 (0.4∼12) mV. The mean longe-vity of pacemaker generator was 64.7$\pm$3.7 (2∼196) months. The reoperation free rate was 94.6% for 1 year, 93.6% for 2 years, 80.8% for 5years, 63.7% for 7 years, and 45.5% for 10 years. The causes of reoperation were battery waste in 26 cases and lead malfunction in 9 cases. There was no postoperative death related to pacemaker malfunction. Conclusion: in the childrens, average longevity of epicardial pacemaker was within accep-table range. 19.1% of the patients required pacemaker related reoperation. However, recent developments, including steroid eluting lead, 6.7% of the patients required pacemaker related reoperation, look promising in expansion of pacemaker life span.