• Title/Summary/Keyword: 심미 치과학

Search Result 859, Processing Time 0.029 seconds

DOUBLE TEETH IN MAXILLARY PERMANENT INCISORS : CASE REPORTS (상악 전치부에 발생한 이중치: 증례보고)

  • Kim, Mi-Ni;Kim, Young-Jae;Kim, Jung-Wook;Jang, Ki-Taek;Kim, Chong-Chul;Hahn, Se-Hyun;Lee, Sang-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.36 no.1
    • /
    • pp.119-125
    • /
    • 2009
  • Fusion and gemination are irregularities in tooth development. It is often difficult to differentiate between gemination and fusion and it is common to refer to these anomalies as 'double teeth'. The deciduous teeth are most commonly involved, but in 0.1% of cases permanent teeth are affected, in which case aesthetic, funtional and periodontal problems can result. Double teeth present great difficulties in management and required a multidisciplinary approach. The central groove on the labial and palatal surfaces of a double tooth is extremely prone to caries, therefore early 'fissure sealing' is essential. In permanent dentition, surgical separation of fused teeth may be possible with subsequent orthodontic alignment and restorative treatment as needed to reshape the crown. Reshaping or reduction of a double tooth with a single canal may be attempted by modifying the appearance of the labial groove and the use of composite tints but is often impossible and extraction may be the only alternative. Orthodontic treatment and prosthetic replacement is then required. Implants may be an option for adolescents. The present study describes three clinical cases of double teeth in the position of the maxillary permanent incisors. The first case demonstrates an example of multidisciplinary care including surgical intraoral hemisection, root canal therapy, restorative and orthodontic treatment. The second and third cases describe the external and internal morphology of the two fused teeth by means of three dimensional dental computer tomography.

  • PDF

Microleakage of endodontically treated teeth restored with three different esthetic post and cores (심미적 포스트 코어의 종류에 따른 미세누출에 관한 연구)

  • Park, Ji-Geun;Park, Ji-Man;Park, Eun-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.1
    • /
    • pp.53-60
    • /
    • 2009
  • Statement of problem: At present, as the esthetic demands are on the increase, there are many ongoing studies for tooth-colored post and cores. Most of them are about fiber post and prefabricated zirconia post, but few about one-piece milled zirconia post and core using CAD/CAM (computer-aided design/computer-aided manufacturing) technique. Purpose: The objective of this study was to compare microleakage of endodontically treated teeth restored with three different tooth-colored post and cores. Material and methods: Extracted 27 human maxillary incisors were cut at the cementoenamel junction, and the teeth were endodontically treated. Teeth were divided into 3 groups (n=9); restored with fiber post and resin core, prefabricated zirconia post and heat-pressed ceramic core, and CAD/CAM milled zirconia post and core. After the preparation of post space, each post was cemented with dual-polymerized resin cement (Variolink II). Teeth were thermocycled for 1000 cycles between $5-55^{\circ}C$ and dyed in 2% methylene blue at $37^{\circ}C$ for 24 hours. Teeth were sectioned (bucco-lingual), kept the record of microleakage and then image-analyzed using a microscope and computer program. The data were analyzed by one-way ANOVA and Scheffe's multiple range test (${\alpha}=0.05$). Results: All groups showed microleakage and there were no significant differences among the groups (P>.05). Prefabricated zirconia post and heat-pressed ceramic core showed more leakage in dye penetration at the post-tooth margin, but there was little microleakage at the end of the post. Fiber post and resin core group and CAD/CAM milled zirconia post and core group indicated similar microleakage score in each stage. Conclusion: Prefabricated zirconia post and heat-pressed ceramic core group demonstrated better resistance to leakage, and fiber post and resin core group and CAD/CAM milled zirconia post and core group showed the similar patterns. The ANOVA test didn't indicate significant differences in microleakage among test groups. (P>.05)

The influence of Collar design on peri-implant marginal bone tissue (Collar design이 임플랜트 주위 변연골 흡수에 미치는 영향)

  • Kim, Jee-Hwan;Jung, Moon-Kyou;Moon, Hong-Suk;Han, Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.1
    • /
    • pp.53-64
    • /
    • 2008
  • Statement of problem: Peri-implant marginal bone loss is an important factor that affects the success of implants in esthetics and function. Various efforts have been made to reduce this bone loss by improving implant design and surface texture. Previous studies have shown that early marginal bone loss is affected by implant neck designs. Purpose: The purpose of this study was to examine the influence of laser microtexturing of implant collar on peri-implant marginal bone loss. Materials and methods: Radiographical marginal bone loss was examined in patients treated with implant-supported fixed partial dentures. Marginal bone level was examined with 101 implant fixtures installed in 53 patients at three periods(at the time of implantation, prosthetic treatment and 6-month after loading). Four types of implants were examined. The differences of bone loss between implants(ITI standard) with enough biologic width and implants(ITI esthetic plus, Silhouette IC, Silhouette IC Laser-$Lok^{TM}$) with insufficient biologic width have been compared. Resorption angles were examined at the time of prosthetic delivery and 6-month after loading. Results and Conclusion: Within the limitation of this study, the following results were drawn. 1. The marginal bone loss of ITI standard and Silhouette IC Laser-$Lok^{TM}$ was less than that of ITI esthetic plus and Silhouette IC(P<0.05). The marginal bone loss between ITI standard and Silhouette IC Laser-$Lok^{TM}$ had no significant statistical difference(P>0.05). There was no significant statistical difference between marginal bone loss of ITI esthetic plus and Silhouette IC(P>0.05). 2. There was no significant difference in marginal bone loss between maxilla and mandible(P>0.05). 3. There was no significant difference in resorption angle among four types of implants(P>0.05). The marginal bone of implants with supracrestal collar design of less than that of biologic width had resorbed more than those with sufficient collar length. The roughness and laser microtexturing of implant neck seem to affect these results. If an implant with collar length of biologic width, exposure of fixture is a possible complication especially in the anterior regions of dentition that demand high esthetics. Short smooth neck implant are often recommended in these areas which may lack the distance between microgap and the marginal bone level. In these cases, the preservation of marginal bone must be put into consideration. From the result of this study, it may be concluded that laser microtexturing of implant neck is helpful in the preservation of marginal bone.

Shear bond strength of ceramic and resin brackets used with visible light-cured adhesives (도재 및 레진 브라켓에 대한 광중합 접착제의 전단 접착 강도)

  • Hwang, Yu-Sun;Row, Joon;Hwaang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.26 no.2 s.55
    • /
    • pp.233-244
    • /
    • 1996
  • The purpose of this study was to compare the shear bond strength obtained from ceramic and plastic brackets bonded with various light-cured adhesives and to evaluate their debonded failure sites. Plastic brackets, Transcend 6000, Signature and Starflre TMB brackets were bonded with Orthobond, Light Bond and Transbond on one hundred forty extracted human premolar teeth as manufacturer's descriptions. After thermocycling the brackets were debonded with an Instron universal testing machine and the debonded bracket base surfaces were inspected under stereoscope to evaluate the failure sites. Also the shear bond strength and failure patterns with different curing time and with two different source of light were compared. The results were as follows. 1. There were no statistically significant differences among the mean shear bond strength of Orthobond, Light Bond and Transbond in a same bracket group except Plastic bracket group(p<0.05). 2. The mean shear bond strength of each adhesive with different bracket groups showed statistically significant differences. Stafire TMB showed the highest shear bond strenght among the brackets in this study, but there was no statistically singnificant difference with Transcend 6000 while there was statistically significant difference with Signature.(p<0.05) 3. The various bonding failure patterns were occurred among different bracket groups but most of failure sites were bracket base -adhesive interfaces. 4. There were no statistically significant differences in shear bond strength between the groups with curing time of 10 second and 20 second, and between the groups with two different sources of light as long as sufficient light intensity(above $400mWcm^2$) were provided(p<0.05). According to the result, it should be considered in clinical use of ceramic bracket with light-cured adhesives that the shear strengths of ceramic brackets were influenced by the retention from of bracket base as well as the composition of bracket and there was no difference in the shear bond strenght among various light-cured adhesives used in this study.

  • PDF

A study of Korean Norm about tooth size and ratio in Korean adults with normal occlusion (한국성인 정상교합자의 치아크기와 비율에 관한 연구)

  • Kim, Dae-Sik;Kim, Young-Jun;Choi, Jae-Hoon;Han, Jong-Hoon
    • The korean journal of orthodontics
    • /
    • v.31 no.5 s.88
    • /
    • pp.505-515
    • /
    • 2001
  • The purpose of this study was to measure the average tooth size of Korean with normal occlusion. According to the study, the average tooth ratios between the upper and lower teeth which could assure the proper ovebite, overjet and good interdigitation were calculated. The normal occluson sample of this study consisted of 43 Korean male adults and 51 Korean female adults. Among them, 22 Korean male adults and 51 Korean female adults were from KAO(Korean Association of Orthodontists), 21 Korean male adults were from Department of Orthodontics, College of Dentistry, Yonsei University. The results from this study were as follows : 1 The average tooth size of Korean Norm classified by male and female was measured. 2. The average tooth size of Korean male adults with normal occlusion was significantly larger than that of Korean female adults except upper and lower first molars. (p<0.05) 3. The tooth ratio which could Predict the proper overbite and overjet in anterior teeth and proper occlusion in posterior teeth was calculated. 1) Sum of inciosrs = 4:2.97 2) Neff's anterior coefficient = 1.22 3) Bolton's anterior ratio = 78.29%, overall ratio = 91.14% 4. A positive correlation was observed between the sum of lower anterior incisors and the sum of unilateral canine and premolars In each jaw. Based this correlation, the regression equation was made which could Predict the sum of unerupted unilateral canine and premolars in mired dentition. 1) Sum of unilateral unerupted upper canine and premolars' width = 10.435018 + 0.513346 ${\times}$ (sum or lower 4 incisors' width) 2) Sum of unilateral unerupted lower canine and premolars' width = 9.654002 + 0.502565 ${\times}$ (sum of lower 4 incisors' width)

  • PDF

EFFECT OF APF GEL ON THE SURFACE OF COMPOSITE RESIN (복합레진 표면에 대한 APF gel의 영향)

  • Yuk, Gun-Yeung;Yang, Kyu-Ho;Kim, Seon-Mi;Choi, Nam-Ki
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.1
    • /
    • pp.43-52
    • /
    • 2006
  • Topical fluoride application for children is a widely peformed procedure in the field of pediatric dentistry to prevent dental caries. However, it is recently recognized as having some unwanted effects on several esthetic restorative materials as it roughens the surface of the restorative materials. The aim of this study was to evaluate the surface changes in composite resins to topical fluoride. Composite resins(Z $250^{(R)}$, Ultraseal $XT^{(R)}$ Filtek $flow^{(R)}$ $Revolution^{(R)}$, $Denfil^{(R)}$) in topical fluoride agents were immersed and their surface roughness, weight loss and SEM were evaluated. The results were as follows : 1. The 4 minutes-immersion groups showed more roughened surface than 1 minute-immersion groups and the control groups showed the smoothest surface among all the materials, and there was statistically significant difference except the revolution between the groups. 2. There was no significant difference between the 1 minute-immersion groups and 4 minutes-immersion groups in weight loss. 3. The experimental group treated with topical fluoride gel showed the generally mere roughened surface than control group in the SEM findings.

  • PDF

The effects of mandibular setback osteotomy on the oropharyngeal airway space in mandibular prognathic patients (하악전돌 환자에서 하악골 후퇴수술이 기도공간에 미치는 영향)

  • Kim, Hyo-Young;Choi, Hyun-Gue;Kim, Eun-Kyung;Kim, Jong-Ghee
    • The korean journal of orthodontics
    • /
    • v.27 no.5 s.64
    • /
    • pp.733-741
    • /
    • 1997
  • As a result of surgical orthodontic treatment of mandibular prognathism, changes take place in the skeletal and soft orofacial components. Although some investigators had stated that permanent reduction of airway space was observed after mandibular setback surgery, it was not clear that this permanent reduction was sustained during long-term follow-up. The purpose of this study was to assess the changes in oropharyngeal airway space and soft tissue orofacial component following the mandibular setback surgery and during the follow-up period. The correlation between the changes of the oropharyngeal airway space and the changes of other soft tissue orofacial component was also assessed. The findings of this study were as follows ; 1. The oropharyngeal airway space area decreased following mandibular setback surgery for mandibular prognathism and continued to decrease during the follow-up period(p<0.05). 2. The pharyngeal depth at Xi point level and the 2nd cervical vertebra point level decreased after the surgery and remained during the follow-up period(p<0.05). The decrease of these pharyngeal depth was correlated with the decrease of oropharyngeal airway space area(p<0.01). 3. The decrease of pharyngeal depth at the 3rd and 4th cervical vertebra point level was not significant after the surgery and during the follow up period. 4. The hyoid bone moved downward after the surgery(p<0.05), but returned to its original position during the follow-up period. 5. The length & height of tongue and the Position of epiglottis base did not change significantly(p>0.05). 6. The soft palate was displaced posteriorly after the surgery and remained to its changed position during the follow-up period(p<0.05) due to posterior displacement of tongue. The changes of soft palate were significantly correlated with the decrease of oropharyngeal airway space area(p<0.01). 7. The narrowing of oropharyngeal airway space was due to the posterior displacement of tongue above the level of epiglottis tip. The posterior displacement of tongue following mandibular setback osteotomy remained during the follow-up period.

  • PDF

Changes of root length and crestal bone height before and after the orthodontic treatment in nail biting patients (손톱 깨물기 습관을 가진 아동의 교정 치료 시 전치부 치근 길이와 치조골 높이의 변화)

  • Hwang, Chung-Ju;Yang, Jae-Hong
    • The korean journal of orthodontics
    • /
    • v.34 no.1 s.102
    • /
    • pp.47-61
    • /
    • 2004
  • Although the purpose of orthodontic treatment is to increase the function and esthetics of the jaws along with increasing stability, there are many side effects during the treatment itself, such as root resorption and alveolar bone resorption. Such resorption of the apical root Is unpredictable, and may even proceed into the dentin layer. Once the process has begun, it is irreversible. By evaluating the effect of many oral habits, especially that of nail biting, in correlation with the root and the periodontal tissues, the appropriate biomechanics for orthodontic treatment can be taken into consideration, along with the possibility of root resorption and alveolar bone loss during orthodontic treatment, and any legal problems that might occur. Among the male and female patients of the ages $10\~15$ without skeletal deformity, 63 were chosen as the experiment group with known nail biting habits at time of examination, and within the same age group without nail biting habits as the control. After the orthodontic treatment, number of the experiment group was 31 and the control group was 22. The periapical radiographies of anterior teeth were taken and the assesment of the root length and alveolar bone level were taken before(T1) and after(T2) the orthodontic treatment. The results from this study were as follows : 1. Before the orthodontic treatment, average crown-to-root ratio of the experimental group showed noticeably high values in 4 maxillary incisors and mandibular right central incisor. 2. Before the orthodontic treatment, comparing the root length, maxillary and mandibular right central incisors and both mandibular incisors had a smaller value in the experimental group. 3. Before the orthodontic treatment, comparing and evaluating the alveolar bone loss measured from the cemento-enamel junction to the alveolar bone crest, some crestal bone of the experiment group showed greater loss than the control. 4. After the orthodontic treatment, there was shortening of the root length and loss of the crestal bone in both groups. 5. After the orthodontic treatment, the changes of C/R ratio and the shortening of root length were significantly high in the experimental group. 6. After the orthodontic treatment, the level of alveolar crestal bone showed greater loss in the experimental group.

The study on the shear bond strength of resin and porcelain to Titanium (티타늄에 대한 레진과 도재의 결합 강도에 관한 연구)

  • Park, Ji-Man;Kim, Yeong-Soon;Jun, Sul-Gi;Park, Eun-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.1
    • /
    • pp.46-52
    • /
    • 2009
  • Statement of problem: Recently, titanium has become popular as superstructure material in implant dentistry because titanium superstructure can be easily milled by means of computer-aided design and manufacture (CAD/CAM) technique. But retention form such as nail head or bead cannot be cut as a result of technical limitation of CAD/CAM milling and bond strength between titanium and porcelain is not as strong as that of conventional gold or metal alloy. Purpose: The objective of this study was to evaluate the shear bond strength of three different materials: heat curing resin, composite resin, porcelain which were bonded to grade II commercially pure Titanium (CP-Ti). Material and methods: Thirty seven CP-Ti discs with 9 mm diameter, 10 mm height were divided into three groups and were bonded with heat curing resin (Lucitone 199), indirect composite resin (Sinfony), and porcelain (Triceram) which were mounted in a former with 7 mm diameter and 1 mm height. Samples were thermocycled for 1000 cycles at between $5-55^{\circ}C$. Shear bond strength (MPa) was measured with Instron Universal Testing Machine with cross head speed of 1 mm/min. The failure pattern was observed at the fractured surface and divided into adhesive, cohesive, and combination failure. The data were analyzed by one-way ANOVA and Scheffe's multiple range test (${\alpha}=0.05$). Results: Lucitone 199 ($17.82{\pm}5.13\;MPa$) showed the highest shear bond strength, followed by Triceram ($12.97{\pm}2.11\;MPa$), and Sinfony ($6.00{\pm}1.31\;MPa$). Most of the failure patterns in Lucitone 199 and Sinfony group were adhesive failure, whereas those in Triceram group were combination failure. Conclusion: Heat curing resin formed the strongest bond to titanium which is used as a CAD/CAM milling block. But the bond strength is still low compared with the bond utilizing mechanical interlocking and there are many adhesive failures which suggest that more studies to enhance bond strength are needed.

A study on the smile of Korean Youth compared with twenty years ago (20년전과 비교한 한국청년의 미소 변화에 관한 연구)

  • Beom, Seung-Gyun;Jung, Ji-Hye;Kim, Tae-Young;Lee, Kyung-Eun;Dong, Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.3
    • /
    • pp.162-168
    • /
    • 2012
  • Purpose: Teeth are generally exposed when people smiling. Moreover, the exposed teeth and soft tissue when smiling becomes an important guideline for esthetically prosthetic restoration. This research is to compare and find out differences of Korean young men's smile living in presence and twenty years ago. Materials and methods: Subjects, 100 young men (50 male and 50 female), were required about several aspects; normally developed physical condition, no psychological or genetic disorders, a fine face with no loss of teeth, no experience in orthodontic or prosthetic treatment, relatively normal occlusion, aged between 20-29. The photos of the subject at rest position and front face when fully smiled were taken three times. 100 photos (50 male and 50 female) were chosen at random from the 240 university students' smile photos taken by Yoon and his colleagues in 1991. By Hulsey's method of measuring smile, several factors; the change of upper lip curvature, the change of the relation between the upper lip and teeth, parallelism between Mx. incisor and lower lip, contact relation between Mx. incisor and lower lip and teeth displayed in a smile, were measured and analyzed. Meanwhile, ten dentists assessed aesthetic evaluation about men and women's smile for twice and recorded and compared smile score. The -test (P<.05) was used to compare the measured value. The difference of smile score was analyzed by t-test (P<.05). Results: The smile score calculated in 2011 (60.22) was higher than that of 1991 (52.80). Among five measurement categories, the noticeable difference was distinguished from two factors; the change of upper lip curvature and contact relation between Mx. incisor and lower lip. Conclusion: The Korean young men's smile has been considerably improved for twenty years. And it is found that the change of upper lip curvature plays an important role, that is, the smile formed with an ascended labial commissure has been increased significantly.