• 제목/요약/키워드: 실외기

검색결과 199건 처리시간 0.024초

에어컨 실외기 받침대의 구조진동 특성 (Structural Vibration Characteristics for an Outdoor Units Support of an Air-conditioner)

  • 류봉조;송선호;임채욱
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 추계학술대회논문집
    • /
    • pp.215-217
    • /
    • 2008
  • This paper deals with the structural vibration characteristics for an outdoor units support of an air-conditioner. Even though main noise sources are compressor noise and fluid noise which is caused by the fan, the structural modification of the outdoor units support may affect vibration and noise. In this paper, damping ratios for two kinds of an outdoor units support of an air-conditioner are measured through the modal testing. In order to reduce the structural borne noise due to an outdoor units support of an air-conditioner, four kinds of rubber materials are selected and tested.

  • PDF

실외기 shroud 형상 최적 설계 (Optimization of design parameters on the shroud of air conditioner outdoor unit)

  • 유기정;예휘열;이상봉;이관수;차우호
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.453-458
    • /
    • 2009
  • This paper presents a numerical evaluation of the flow rate of air conditioner outdoor unit as function of shroud design parameters. To determine the optimal design parameters, we investigated the flow rate by changing bell mouth height, fan height, fan guide height, fan width. The evaluation of the relative priority of the design parameters was performed to choose three important parameters in order to use a response surface method. The flow rate of the optimum model, compared to that of the base model, was increased by about 6.25%.

  • PDF

반동 전단 구조 인텐서티 측정에 의한 제진재 적용과 그에 따른 에어컨 실외기 구조 방사 소음 저감 (Placing Constrained Layer Damping Patches Using Reactive Shearing Structural Intensity in Order to Reduce the Radiated Sound Power of a Air-Conditioner Outdoor Unit)

  • 김규식;강연준;진심원;정인화;이정우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.333-337
    • /
    • 2003
  • The use of reactive shearing structural intensity to place small patches of constrained layer damping material in order to achieve the largest reduction in the radiated sound power of Air-conditioner outdoor unit is described. The normal surface velocity of each panel was measured using a laser doppler vibrometer. Experimental results indicated that patches of constrained layer damping material placed over areas of high reactive structural intensity reduced the radiated sound power significantly more than patches of the same area placed over areas of low reactive structural intensity

  • PDF

실외기 토출 유량 증대를 위한 Shroud 형상 및 휀 위치 최적 설계 (Optimization of Shroud Shape and Fan Location for Increasing Exhaust Flow Rate of Air Conditioner Outdoor Unit)

  • 유기정;김유일;이관수;차우호
    • 설비공학논문집
    • /
    • 제21권11호
    • /
    • pp.599-605
    • /
    • 2009
  • This paper presents a numerical evaluation of the flow rate of air conditioner outdoor unit by investigating the effects of fan location and shroud shape. To determine optimal design parameters, we investigated the exhaust flow rate by changing shroud height, fan height, fan guide height, and fan width. The 3rd order central composite design was performed to select three most important parameters affecting the exhaust flow rate. According to the result of response surface method, the exhaust flow rate of the optimum model increased by 6.25% compared to that of the base model.

실외기 shroud 설계 인자에 따른 유량 특성 (Characteristics of flow rate according to design parameters of a shroud in outdoor unit)

  • 유기정;김민수;차우호;이관수
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.244-249
    • /
    • 2008
  • In this study, the characteristics of flow in outdoor unit were numerically analyzed. Parametric studies were performed to compare the effect of bell mouth height, fan height and fan width concerned with flow rate. The result indicated that the flow rate was dependent on the bell mouth height, while it was negligibly affected by the fan height and fan width. The fan width was found to affect the velocity distribution at heat exchanger face.

  • PDF

구조 인텐서티법을 이용한 에어컨 실외기의 제진재 적용 (Damping Patch Placement on Outdoor Unit of Air-conditioner by Using Structural Intensity Technique)

  • 김규식;진심원;정인화;이정우;강연준
    • 한국소음진동공학회논문집
    • /
    • 제14권7호
    • /
    • pp.577-585
    • /
    • 2004
  • In this paper, reactive shearing structural intensity method is extended to damping patches placement on outer panels of outdoor unit of air-conditioner to reduce its structural borne noise. The structural intensity is calculated from the normal velocities of structures that are measured by using a laser scanning vibrometer, and $textsc{k}$-space (wave-number domain) signal processing is used to obtain the spatial derivatives in formulation of structural intensity. This method is applied to the outdoor unit of air-conditioner on shaker-exciting mode and operating mode. and then damping patches are placed over area of high reactive shearing structural intensity for reducing the radiated noise. Experimental results show the largest reduction of sound pressure level of an outdoor unit by appling small damping patches to optimal position.

실외기 기능 교번을 통한 착상 방지 및 지연에 대한 실증 연구 (Feasibility Study on the Frost Prevention and Delay by the Method of Alternating the function of Outdoor Coil Rows)

  • 전창덕
    • 융복합기술연구소 논문집
    • /
    • 제1권1호
    • /
    • pp.1-4
    • /
    • 2011
  • The object of this experimental study is to investigate the effect on frost prevention and delay by the method of alternating the function of outdoor coil rows under the frost conditions ($2^{\circ}C/1^{\circ}C$). The heat pump system with the new method can make frost delay time longer and eliminate frost effectively. It is withstand over 280 minutes without a conventional defrosting method. Maximum COP in case of adopting new method is 13% higher than that in case of reverse cycle defrosting method. Also in case of moving air injection duct faster, the frost delay time is lengthened and its COP is enhanced more.

  • PDF

여름철 피크전력제어 ESCO에 맡기면 척척!!

  • 에너지절약전문기업협회
    • ESCO지
    • /
    • 통권10호
    • /
    • pp.22-25
    • /
    • 2001
  • 아주대학교가 전력수요관리를 위해 설치한 Demand Controller는 전기 사용량을 상시 감시하면서 목표전력을 초과할 것이 예상될 경우 에어컨 실외기를 자동제어 해준다. 지난해 ESCO사업으로 공사를 실시, 절감효과가 뛰어나 2차 추가공사를 진행하고 있다.

  • PDF

시스템 에어컨 실외기 포장품의 낙하충격해석 및 시험적 검증 (Drop Impact Analysis of Outside Cooling Unit Package of System Air-Conditioner and Experimental Verification)

  • 김형석;이부윤;이상훈
    • 한국산학기술학회논문지
    • /
    • 제19권4호
    • /
    • pp.111-116
    • /
    • 2018
  • 본 논문은 시스템 에어컨 실외기 포장품의 낙하충격해석 및 시험검증을 수행한 내용을 다룬다. 포장은 낙하충격으로 부터 제품을 보호할 수 있도록 충격에너지를 흡수할 수 있는 완충재질과 이를 제품에 고정하기 위한 부재로 구성되는데 작은 부피로 충분한 완충성능을 발휘하는 포장 설계를 위해서는 충격 시 제품에 가해지는 충격가속도 등을 정확히 평가하는 것이 필수적이다. 본 논문에서는 외연적 시간적분을 활용하는 유한요소해석 기법을 활용하여 실외기 포장품의 낙하충격해석을 수행하였다. 정확한 해석을 위한 해석모델 구축, 재료 시험을 통한 데이터 획득 및 재료 모델의 선정, 신뢰성 있는 해석 데이터 확보를 위한 계측 센서의 모델링 등이 수행되었으며 이렇게 구해진 해석데이터와 시험으로 구해진 가속도 및 변형률 시간이력을 비교하였다. 해석모델에 반영된 감쇄계수 등의 오차로 인하여 대체로 해석결과가 시험 결과에 비해 충격 가속도 및 변형률을 크게 예측하고 있으나 전체적인 데이터의 경향과 낙하 방향의 충격가속도는 정확하게 계산되었다. 이에 본 연구에 사용된 모델 및 해석기법을 에어컨 실외기 포장 설계에 활용할 수 있음을 확인하였다.