• Title/Summary/Keyword: 실시간 초음파 영상

Search Result 92, Processing Time 0.03 seconds

A Study on Location Tracking Streetlight (위치추적 가로등에 관한 연구)

  • Kim, Bum-Su;Kim, Seung-Goo;Song, Hyeong-Ho;Kim, Bo-Ryeon;Han, Young-Oh
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.6
    • /
    • pp.1275-1280
    • /
    • 2018
  • We made a smartphone interlocking location tracking streetlight and remote display device to compensate the defect of real time identifiable CCTV streetlights and child safety notification applications. It controls brightness of LED by detecting the surrounding brightness and objects with ultrasonic sensor and illuminance senor. The CCTV receives the location of smartphone by Bluetooth and takes the target of the location. It realizes a wireless transmission system that the video is upload to the tablet PC via WiFi.

Medial Gastrocnemius Ultrasound Imaging of Delayed Onset Muscle Soreness over time (시간경과에 따른 지연성근통증 내측 비복근의 초음파 영상)

  • Lee, Wan-Hee;Cho, Ki-Hun;Lee, Kyoung-Suk;Kim, Mi-Hwa
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.6
    • /
    • pp.2632-2640
    • /
    • 2012
  • The purpose of this study was to investigate whether medial gastrocnemius ultrasound imaging of the Delayed Onset Muscle Soreness (DOMS) has the possibilities as a measurement method. This study was conducted from April 21th 2011 to April 30th 2011. Thirty-five healthy subjects were included based on the absence of regular physical activity, and no history of recent trauma, musculoskeletal pathology, cardiovascular disease or drug intake. All subjects induced DOMS through climbing for 5 hours and we measured the visual analogue scale (VAS), creatine kinase (CK) and maximal voluntary isometric contraction (MVlC) of ankle plantar flexor prior to DOMS and at 24, 48 and 72 hours post DOMS and these measurements were compared with pennation angle of medial gastrocnemius measured by ultrasound imaging. Results of this study were as following. VAS, CK, and MVIC of ankle plantar flexor were found significant difference related measurement period (p<0.05) and pennation angle of medial gastrocnemius were found significant difference related measurement period (p<0.05). Furthermore, we confirmed that the flow of change between variables related measurment period was consistent. Through this study, we think that measuring the changes in pennation angle of medial gastrocnemius over time using ultrasound imaging will be able to be used as a new method measuring DOMS.

A Study on the Quality Control of Transvaginal Ultrasound Transducer using ATS-539 Ultrasound Phantom (ATS-539 초음파 팬텀을 이용한 경질 초음파 검사용 탐촉자의 정도관리에 대한 연구)

  • Park, Ji Hye;Heo, Yeong Cheol;Kim, Yon min;Han, Dong Kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.4
    • /
    • pp.463-472
    • /
    • 2021
  • Demand for examinations using transvaginal transducer with high frequencies is increasing to observe pelvic organs in gynecological ultrasound tests. However, the quality control of the replacement probe in clinical trials is not properly implemented and the evaluation criteria have not been established. Therefore, 58 transvaginal transducers and 20 convex transducers were applied to the ATS-539 ultrasound phantom for 20 ultrasound devices currently in clinical use to obtain their respective images and measure them quantitatively and qualitatively. For quantitative measurements, vertical measurement, horizontal measurement, and focal zone and qualitative measurements, dead zone, axial·lateral resolution, sensitivity, functional resolution, gray scale·dynamic range were performed. Quantitative statistical analysis showed significant differences between the two transducers in the lateral measurement and local area (p<0.05). qualitative comparative analysis showed differences in sensitivity and functional resolution. This occurs due to the difference in frequency between transducers and the transducer's injection geometry. Based on the above experiments, the tolerance for horizontal measurement is raised to 10% (±8 mm), the tolerance for sensitivity is observed up to 6 cm deep, which is 12 cm deep,which is the level of the third quartile (75%). The permissible range of functional resolution is up to 6 (12 cm), 6 (12 cm), 11 (11 cm), 9 (9 cm), 6 (6 cm) target, which is the level of the third quartile (75%). It is considered reasonable to adjust the depth of targets in gray scale·dynamic range to measure at a depth of 2 cm, which is 50% of the depth of 4 cm. As above, the criteria for evaluating the quality of transvaginal transducer for use in the past have been proposed and it is expected that this study will be used as a basic data for the production of phantom exclusively for transvaginal transducer in the future.

Development of an Automatic Sprayer Arm Control System for Unmanned Pest Control of Pear Trees (배나무 무인 방제를 위한 약대 자동 제어시스템 개발)

  • Hwa, Ji-Ho;Lee, Bong-Ki;Lee, Min-Young;Choi, Dong-Sung;Hong, Jun-Taek;Lee, Dae-Weon
    • Journal of Bio-Environment Control
    • /
    • v.23 no.1
    • /
    • pp.26-30
    • /
    • 2014
  • Purpose of this study was a development of a sprayer arm auto control system that could be operated according to distance from pear trees for automation of pest control. Auto control system included two parts, hardware and software. First, controller was made with an MCU and relay switches. Two types of ultra-sonic sensors were installed to measure distance from pear trees: one on/off type that detect up to 3 m, and the other continuous type providing 0~5 V output corresponding to distance of 0~3 m. Second, an auto control algorithm was developed to control. Each spraying arm was controlled according to the sensor-based distance from the pear trees. And it could dodge obstacles to protect itself. Max and min signal values were eliminated, when five sensor signals was collected, and then signals were averaged to reduce sensor's noises. According to results of field experiment, auto control test result was better than non auto control test result. Spraying rates were 69.25% (left line) and 98.09% (right line) under non auto control mode, because pear trees were not planted uniformly. But, auto control test's results were 92.66% (left line) and 94.64% (right line). Spraying rate was increased by maintaining distance from tree.

Active Water-Level and Distance Measurement Algorithm using Light Beam Pattern (광패턴을 이용한 능동형 수위 및 거리 측정 기법)

  • Kim, Nac-Woo;Son, Seung-Chul;Lee, Mun-Seob;Min, Gi-Hyeon;Lee, Byung-Tak
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.4
    • /
    • pp.156-163
    • /
    • 2015
  • In this paper, we propose an active water level and distance measurement algorithm using a light beam pattern. On behalf of conventional water level gauge types of pressure, float-well, ultrasonic, radar, and others, recently, extensive research for video analysis based water level measurement methods is gradually increasing as an importance of accurate measurement, monitoring convenience, and much more has been emphasized. By turning a reference light beam pattern on bridge or embankment actively, we suggest a new approach that analyzes and processes the projected light beam pattern image obtained from camera device, measures automatically water level and distance between a camera and a bridge or a levee. As contrasted with conventional methods that passively have to analyze captured video information for recognition of a watermark attached on a bridge or specific marker, we actively use the reference light beam pattern suited to the installed bridge environment. So, our method offers a robust water level measurement. The reasons are as follows. At first, our algorithm is effective against unfavorable visual field, pollution or damage of watermark, and so on, and in the next, this is possible to monitor in real-time the portable-based local situation by day and night. Furthermore, our method is not need additional floodlight. Tests are simulated under indoor environment conditions from distance measurement over 0.4-1.4m and height measurement over 13.5-32.5cm.

A Study on Apparatus of Smart Wearable for Mine Detection (스마트 웨어러블 지뢰탐지 장치 연구)

  • Kim, Chi-Wook;Koo, Kyong-Wan;Cha, Jae-Sang
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.2
    • /
    • pp.263-267
    • /
    • 2015
  • current mine detector can't division the section if it is conducted and it needs too much labor force and time. in addition to, if the user don't move the head of sensor in regular speed or move it too fast, it is hard to detect a mine exactly. according to this, to improve the problem using one direction ultrasonic wave sensing signal, that is made up of human body antenna part, main micro processor unit part, smart glasses part, body equipped LCD monitor part, wireless data transmit part, belt type power supply part, black box type camera, Security Communication headset. the user can equip this at head, body, arm, waist and leg in removable type. so it is able to detect the powder in a 360-degree on(under) the ground whether it is metal or nonmetal and it can express the 2D or 3D film about distance, form and material of the mine. so the battle combats can avoid the mine and move fast. also, through the portable battery and twin self power supply system of the power supply part, combat troops can fight without extra recharge and we can monitoring the battle situation of distant place at the command center server on real-time. and then, it makes able to sharing the information of battle among battle combats one on one. as a result, the purpose of this study is researching a smart wearable mine detector which can establish a smart battle system as if the commander is in the site of the battle.

Importance of integrating Bioinformation and Health Informatics for Healthcare

  • 곽연식
    • Proceedings of the Korean Society for Bioinformatics Conference
    • /
    • 2002.06a
    • /
    • pp.89-104
    • /
    • 2002
  • 유전체연구사업단은 국내에서 발병 및 사망빈도가 가장 높은 위암과 간암의 퇴치를 목적으로 국가적 특목전략사업으로 연구를 추진하고 있다. 이와 별도로 보건복지부에서는 22개의 중요 질병별 유전체 연구센터를 전국적으로 추진하고 있다. 따라서, 연구가 성공적으로 진행되면 각 연구소에서 독자적으로 개발하여 제공하는 생명정보의 양은 거의 무한에 이를 것이다. 그러나 생명정보는 환자진료에 도움을 주기 위해서는 궁극적으로 임상정보와 함께 유기적으로 통합되어야 한다. 임상정보와의 통합을 위해서는 의료기관의 진료정보와 연구소의 생명정보가 연계되어 엄밀한 임상실험이 추가적으로 실시되어야 한다. 뿐만 아니라 생명정보학의 발전을 위해서는 연구대상의 임상정보가 공유되어야 한다. 유전체정보를 이용하는 생명정보학(Bioinformatics)은 각 국가마다 전략사업으로 간주하여 막대한 투자가 이루어지는 새로운 분야이다. 현재 선진국에서 개발 사용 중인 시스템의 연간 사용료가 고가이므로 국내 도입은 거의 불가능하거나 또는 매우 비효율적이다. 유전체 또는 생명정보의 임상활용 및 생명정보연구를 위한 임상정보 공유를 위해서는 우선 다음의 사항이 개발되어야 한다. 1) 다음과 같은 개별환자의 정보를 각 의료기관에서 제공 받아 저장 활용한다. - 진찰 및 임상소견, 수술기록, 경과기록, 검사결과 (임상병리, 해부병리, 방사선 등), - 영상정보 (X-ray, CT, MRI, 초음파, 전자현미경, 그래픽 등), - 환자개인기록(병력, 과거력, 가족력, 알러지 등), - 예방접종 기록 2) 각 연구소에서 첨단기술을 이용하여 개발되는 생명정보를 임상에 활용하기 위해서는 유전체연구센타와 병원간에 임상정보와 유전체 분석정보의 공유가 필수적으로 발생하게 됨으로, 유전체 정보와 임상정보의 통합은 미래 의료환경에 필수기능이 될 것이다. 3) 각 생명공학 연구소에서 사용하는 첨단 분석 장비와 생명공학 정보시스템의 자동 연계가 필요하다. 현재 국내에는 전국적인 초고속정보망이 가동되어 웹을 기반으로 하는 생명정보의 공유는 기술적으로 문제가 될 수 없으나 임상정보의 유전체연구에 그리고 유전체연구정보의 임상활용은 다양한 문제를 내포하고 있다. 이에 영상을 포함한 환자정보의 유전체연구센터와 병원정보시스템과의 효율적인 연계통합 운영을 위해 국내에서는 초기 도입단계에 있는 국제적인 보건의료정보의 표준인 Health Level 7 (textural information 공유), DICOM (image 및 wave 공유), 관련 ISO표준, WHO의 ICD9/10 (질병분류), LOINC (검사 및 관련용어), SNOMED International (의학용어) 등을 활용하여야 한다.

  • PDF

Navigation system for the people who are visually impaired using ARM Cortex-A9 Platform (ARM Cortex-A9 Platform기반의 시각장애인을 위한 Navigation System 구현)

  • Lim, Ik-chan;Kim, Young-kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.93-95
    • /
    • 2013
  • The conventional assistive tool for visually impaired people provide Simple service using a ultrasound, or an RFID tag to identify the obstacles. It is impossible to clear guide and has a vulnerability to unforeseen circumstances because of short recognition distance, The ARM Cortex-A9 Platform based implementation of the Portable Navigation System and Service Center will help the visually impaired gait. The Service Center will also provide solution for the lack of jobs due to the increase of the aging population. Navigation System that the visually impaired can carry possessing devices such as a camera, GPS, Audio, Ethernet transmit Image shown at the location of the visually impaired, GPS information and Sound Via TCP / IP. The staff of the service center receives information and can provide directions by communicating with them. So, the system can provide effective guidance to the visually impaired.

  • PDF

The Effects of Task-Oriented Training for Left Trunk Flexion Pattern Using Real-Time Ultrasound Imaging -A Single-Subject Experimental Study- (편측무시 환자에게 실시간 초음파 영상을 이용한 왼쪽 몸통 굽힘 패턴을 적용한 과제지향적 훈련의 효과 -단일 사례 연구-)

  • Kim, Ji-Seon;Ki, Kyong-Il;Kang, Tae-Woo
    • PNF and Movement
    • /
    • v.17 no.1
    • /
    • pp.1-9
    • /
    • 2019
  • Purpose: This study investigates the effects of task-oriented training for a left trunk flexion pattern using real-time ultrasound imaging in a stroke patient with unilateral neglect symptoms. Methods: This study used the ABA experimental design, which is a single-subject research method among individual case research methods. For the ABA experimental design, changes in the degree of unilateral neglect, balance ability, and the thickness of the lateral abdominal muscle were visually analyzed during the baseline process, in the intervention period, and after the intervention. The experiments were performed 24 times in total for 8 times in each of the 3 periods. The unilateral neglect was measured using the Albert test, balance ability was measured using the Berg balance test, and the thickness of the lateral abdominal muscle was measured using ultrasound imaging. The subject was a 50-year-old male patient with unilateral neglect caused by right cerebral hemorrhage. He performed task-oriented training for a voluntary left trunk flexion pattern using real-time ultrasound imaging during the intervention period. Results: The result of comparing the data collected during the intervention period with the data point average of the baseline process showed that balance ability improved and the tendency line was above the baseline. The tendency line of unilateral neglect was below the baseline and showed a decreasing tendency. The thickness of the lateral abdominal muscle showed an increasing trend and the tendency line was above the baseline. Conclusion: The results of this study suggest that the task-oriented training for left trunk flexion pattern using real-time ultrasound imaging has a beneficial effect on balance ability, the degree of unilateral neglect, and the strength of the lateral abdominal muscle in unilateral neglect patients.

The Design of the Obstacle Avoidances System for Unmanned Vehicle Using a Depth Camera (깊이 카메라를 이용한 무인이동체의 장애물 회피 시스템 설계)

  • Kim, Min-Joon;Jang, Jong-Wook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.224-226
    • /
    • 2016
  • With the technical development and rapid increase of private demand, the new market for unmanned vehicle combined with the characteristics of 'unmanned automation' and 'vehicle' is rapidly growing. Even though the pilot driving is currently allowed in some countries, there is no country that has institutionalized the formal driving of self-driving cars. In case of the existing vehicles, safety incidents are frequently happening due to the frequent malfunction of the rear sensor, blind spot of the rear camera, or drivers' carelessness. Once such minor flaws are complemented, the relevant regulations for the commercialization of self-driving car and small drone could be relieved. Contrary to the ultrasonic and laser sensors used for the existing vehicles, this paper aims to attempt the distance measurement by using the depth sensor. A depth camera calculates the distance data based on the TOF method calculating the time difference by lighting laser or infrared light onto an object or area and then receiving the beam coming back. As this camera can obtain the depth data in the pixel unit of CCD camera, it can be used for collecting depth data in real-time. This paper suggests to solve problems mentioned above by using depth data in real-time and also to design the obstacle avoidance system through distance measurement.

  • PDF