• 제목/요약/키워드: 실별제어시스템

검색결과 7건 처리시간 0.02초

바닥복사난방의 실별제어시스템에 관한 열성능 평가 (An Evaluation on the Thermal Performance of the Room Control System for Radiant Floor Heating)

  • 석호태;김오봉;조영흠;김광우;여명석
    • 한국주거학회논문집
    • /
    • 제14권5호
    • /
    • pp.75-82
    • /
    • 2003
  • In this study, the thermal performance of the room control system is analyzed in terms of control performance, potential for coil expansion and energy consumption through experiments comparing the individual room control system and an existing system. The results of this study show that the existing system is not able to supply design water flow rate and does not accurately maintain the set point temperature in each room. However, the individual room control system can set a room air temperature for each room, for it is able to supply design water flow and accurately control the set point temperature in each room and can reduce the energy consumption compared to the existing system. Moreover, the individual room control system can reduce the number of coil division zone and facilitates the construction process, because it can extend the length of the coil division.

변풍량 공조 시스템의 제어

  • 주영덕
    • 대한설비공학회지:설비저널
    • /
    • 제29권2호
    • /
    • pp.39-45
    • /
    • 2000
  • 1970년대부터 사용된 변풍량 공조 시스템 (Variable Air Volume System)은 실내 부하 변동에 따라 급기 온도를 일정하게 유지시키고 실별, 존별 송풍량을 변화시켜 실온을 제어하는 방식으로, 에너지 절약, 개별 제어 등의 장점 때문에 적용이 확대되었고 특히 단일덕트 변풍량 공조 시스템은 이러한 이유 때문에 많은 건물에 적용되고 있다. 그러나 현 제어시스댐의 풍량 측정의 문제점과 공조기내에서 풍량변화 및 급/배기 댐퍼의 개도 변경으로 인한 환기 댐퍼의 비선형 특성을 고려하지 않고 제어하기 때문에 외기량 확보를 정확히 유지 못하는 실정이다. 따라서 단일덕트 변풍량 시스템의 환기댐퍼 및 급기, 환기 팬의 제어 방식의 종류와 특성 및 문제점에 대하여 설명하고자 한다.

  • PDF

실별제어 온수분배기의 유량분배 특성 (A Flow Quantity Distribution Characteristics of the Hot Water Header for Individual Room Control System)

  • 성순경
    • 설비공학논문집
    • /
    • 제20권3호
    • /
    • pp.175-180
    • /
    • 2008
  • Flow quantity to supply to a coil in floor heating system is important to achieve comfortable indoor air condition in the winter season. The hot water header is used to distribute the water into the coil. Experimental study has been performed using the water header that have 5 branches consisted of flow control valves and automatic shut-off valves. Each branch line connected it with X-L pipe. Experimental tests accomplished it to investigate the flow distribution characteristics of the hot water header. Experimental results show that the selection of the pump head and differential pressure are very important to save running energy of the system, and high differential pressure needs more friction loss in the case of suitable differential pressure for balancing of the header.

난방시 실별 연동형 세대자동유량제어 시스템 (Auto Flow Rate Regulating System Synchronized with Room Control)

  • 김영균;김남근;서범석
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.77-82
    • /
    • 2009
  • If we can supply accurate minute flow rate to the households, we can solve many problems that are occurring in consequences of uncontrolled flow rate for the households. Therefore, this paper presents an innovative solution to the source of the problems by illustrating how we can control the flow rate to the household. This paper proves such problems even can be solved in a case when there is a room turned off the heating.

  • PDF

RFID를 이용한 교도소의 온라인 통제 시스템 개발 (Development of On-line Control System Using RFID On the Prison)

  • 박승환;구자일
    • 전자공학회논문지 IE
    • /
    • 제45권4호
    • /
    • pp.74-79
    • /
    • 2008
  • 본 논문은 교도소 출입문의 모든 개폐 현황과 정보를 온라인 네트워크를 통하여 중앙의 통제실에서 실시간으로 확인할 수 있도록 하고, 실별, 층별로 위치한 다수의 출입문 개폐동작을 개별 또는 병렬로 동시에 동작할 수 있도록 하는 중앙통제에 의한 양방향 제어시스템을 구성하였다. 현재 사용 중인 125kHz대 RFID기술의 단점을 보완하기 위해서 13.55MHz대 RFID 기술을 적용하여 보안 및 신뢰성 문제를 해결하였으며, 비정상적으로 문이 열릴 경우 경광등 및 경보음을 울리도록 하는 온라인 통제 및 관리 시스템을 개발하였다.

공동주택에서 바닥복사 난방시스템의 실별 제어에 관한 연구 (A Study on the Individual Room Control of Radiant Floor Heating System in Apartment Buildings)

  • 김오봉;이미경;김광우;여명석
    • 설비공학논문집
    • /
    • 제16권5호
    • /
    • pp.421-429
    • /
    • 2004
  • In Korea, the radiant heating system has been widely used as a residential heating method, which has been modernized to use hot water running into the tubes embedded in the floor structure. According to the recent improvement of living standard of residential buildings, the requirement of the thermal comfort and energy saving in heating system has been raised. Until now, the radiant floor heating system has been controlled by room thermostat installed in the living room, but for better thermal comfort, an individual room control method is adopted as an alternative. Therefore, it is necessary to evaluate the control performance between the current control method and the individual room control method. In this study, the control performance between the two systems is evaluated through the field experiment. And the control performances of room air temperature and energy performances are analyzed through the simulation using TRNSYS. Firstly, the simulations are performed in the various outdoor conditions and the flow rates and the simulation results are analyzed for the control performances. Also, to evaluate the energy performance, the simulations are performed under the operating conditions in which the set-point of the room air temperature is fixed or changed according to the schedule of occupancy, and the simulation results are analyzed between the two methods.