• Title/Summary/Keyword: 실내 온도차비율

Search Result 3, Processing Time 0.016 seconds

Condensation Prevention Performance Assessment Taking Into Account Thermal Insulation Performance Degradation Due to Aging for Apartment Housing

  • Choi, Doo-Sung;Lee, Myung-Eun
    • KIEAE Journal
    • /
    • v.15 no.6
    • /
    • pp.11-18
    • /
    • 2015
  • Purpose: The current study analyzed trends in thermal insulation performance with aging, and condensation characteristics caused by the former. Method: Thermal insulation and condensation prevention performance of an architecture were assessed using Temperature Difference Ration Inside, or TDRi. Subjects of this quantitative analysis in thermal insulation performance change due to aging included recently constructed apartments and aged apartments older than 40 years. Time series comparison and analysis were conducted to observed changes in the thermal insulation performance and condensation characteristics. Result: Analysis showed that wall insulation performance degraded with aging regardless of fortified insulating material usage or insulating material type, which caused increased danger of condensation. In addition, when fortified insulating material was installed on the connection between the walls, insulation performance degradation was lower compared to cases in which fortified materials were not used. In all cases from 1 to 10, the rate of thermal insulation performance degradation increased after 20 years of aging.

A Studs on Farmers Syndrome and Its Risk Factors of Vinylhouse Workers and Evaluation of Risk Factors of Vinylhouse Works (일부 농촌지역 비닐하우스 농사자들의 작업환경 및 농부증 실태와 관련요인평가)

  • Lee, Jung-Jeung
    • Journal of agricultural medicine and community health
    • /
    • v.29 no.1
    • /
    • pp.101-119
    • /
    • 2004
  • Objectives: In order to estimate risk factors affecting the health of vinylhouse workers and harmful environments in vinylhouse working. Methods: The investigator performed questionnaires and laboratory examinations on 102 vinylhouse workers and 69 farmers in 7 myoens (Korean subcounties). one eup (a Korean town), Goryeong-gun, Gyeongsangbuk-do between April 8 and 18, 2004 (for 11 days), and measured the heavy metal in the air and the soil, temperature, humidity, air current, harmful gases in vinylhouses. Results: Even in cloudy days, the temperature in vinylhouses in daylight was $33.4^{\circ}$ and the temperature difference between inside and outside vinylhouses was around $16^{\circ}$. Oxygen concentration was similar inside and outside vinylhouses, while carbon dioxide concentration was lower inside than outside vinylhouses. Carbon monoxide was not detected. In the air inside vinylhouses, cadmium was not detected. Lean concentration in the soil was lower inside vinylhouses than outside vinylhouses at surface, while cadmium concentration was similar inside and outside vinylhouses in the soil except some areas. Out of male vinylhouse workers. 16.4---- were positive farmer's syndrome and 49.2---- were suspicious, while out of females, 41.5---- were positive and 46.3---- were suspicious. Out of male farmers, 30.4---- were positive farmer's syndrome, while out of female farmers, 60.0---- were positive and 28.3---- were suspicious. There was no difference between vinylhouse workers and farmers in the distribution of hypertension and abnormal liver function, while diabetes mellitus was more common in farmers than in vinylhouse workers. Vinylhouse working, sex, and hours of farming per day were selected as significant variables affecting farmer's syndrome in this study, and the rate of positive farmer's syndrome was rather lower in vinylhouse workers than in farmers. Females were higher than males in the rate, and those who farmed at least 10 hours per day were higher in the rate than those who farmed less than 10 hours per day. Out of the vinylhouse workers, no differences were found between the distribution of farmer's syndrome and farming-related variables such as the total period of farming, the size of farm land, the mean farming hours per day, the number of family members who farm together, the frequency of scattering agricultural chemicals. In addition, there were no differences between the distribution and the wearing masks and protectors and personal sanitation among those who scattered agricultural chemicals by themselves. There were no differences found in blood lean concentration, urinary cadmium concentration, serum cholinesterase, and hemoglobin according to the distribution of farmer's syndrome. In the vinylhouse workers, females were higher than males in the rate of farmer's syndrome, and those who farmed at least 10 hours per day were higher in the rate than those who farmed less than 10 hours per day. Meanwhile, the rate was lower in those who slept at least 8 hours a day than in those who slept less than 8 hours. Conclusions: In conclusion, the physical environments inside vinylhouses were harmful, but no significant difference was found in harmfulness of the chemical environments. The chronic diseases such as farmer's syndrome. hypertension, diabetes, and dyshepatia were not common in the vinylhouse workers than in the farmers. Meanwhile, farmer's syndrome was more common in the vinylhouse workers who worked longer and slept less.

  • PDF

Insulation Performance Analysis of Vulnerable Parts of Thermal Bridge and Condensation in Modular Buildings (모듈러 주택의 열교 및 결로 취약부위별 단열성능 분석)

  • Kim, Miyeon;Kim, Hyunggeun;Park, Jinchul
    • Korean Journal of Construction Engineering and Management
    • /
    • v.22 no.3
    • /
    • pp.31-39
    • /
    • 2021
  • The modular construction method is an off-site construction method using built-in structures from the manufacturing facilities. Modular construction is commonly applied to buildings which have relatively smaller and simpler structures than other types of buildings. Although modular building has emerged in the domestic construction industry as an alternative building strategy, previous researches on the environmental characteristics of modular building has not been comprehensively studied. Thus, this study empirically analyzed the insulation performance of thermal bridge and condensation parts of the modular buildings by using IR image analysis, Air-Surface Temperature Ratio method, and temperature difference ratio. The insulation performance analysis was conducted by comparing a modular building and a RC building in Seoul. The results shows that there was no significant difference between insulation performances of RC building and modular building. Furthermore