The Impact of Ventilation Strategies on Indoor Air Pollution: A Comparative Study of HVAC Systems Using a Numerical Model (실내오염물질의 환기기술전략에 따른 영향평가 : 수치적 모델을 이용한 HVAC 시스템의 비교연구)

  • Park, Sung-Woo;Song, Dong-Woong;D.J. Moschandreas
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.11 no.E
    • /
    • pp.45-54
    • /
    • 1995
  • Indoor air quality models are useful to predict indoor air pollutant concentrations as a function of several indoor factors. Indoor air quality model was developed to evaluate the pollutant removal efficiency of variable-air-volume/bypass filtration system (VAV/BPFS) compared with the conventional variable-air-volume (VAV) system. This model provides relative pollutant removal effectiveness of VAV/BPFS by concentration ratio between the conventional VAV system and VAV/BPFS. The predictions agree closely, from 5 to 10 percent, with the measured values for each energy load. As a results, we recommend the VAV/BPFS is a promising alternative to conventional VAV system because it is capable of reducing indoor air pollutant concentration and maintaining good indoor air quality.

  • PDF

A Development of Coupled Simulation Tool to Evaluate Performance of Ventilation System (환기시스템의 성능평가를 위한 통합 시뮬레이션 Tool의 개발)

  • Cho Wang-Hee;Song Doo-Sam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.2
    • /
    • pp.112-121
    • /
    • 2006
  • To evaluate the performance of ventilation system properly, the correlations among the ventilation rate, indoor air-quality and cooling/heating load should be analysed. In this study, simulation tool to analyze the performance of ventilation system was developed. The simulation tool is based on the TRNSYS and some modules to calculate concentration of pollutants with the operation of ventilation system and to decide the signal of ventilation system were newly developed in this study. And these modules coupled with building load and heating/cooling simulation modules. To verify the validity of developed simulation tool, comparison study between simulation and field study were accomplished. As results, the simulation tool developed in this study can be used to predict the performance of ventilation system with accuracy.

A Research on the Noise Reduction of a Kitchen Ventilation System and the Prediction of Sound Distribution in a Kitchen and Room (주방환기 시스템의 소음 저감과 실내 음장분포 예측에 관한 연구)

  • Song, Hwa-Young;Lee, Dong-Hoon;Lee, Chang-Kun;Kim, Dong-Yun;Hong, Byung-Kuk
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.494-499
    • /
    • 2005
  • This paper introduces a study for the noise reduction of a range hood for household. Generally, range hoods have a built-in sirocco fan from which harsh noises are generated. Though the harsh noises have low noise level, these kinds of noises make most of the users nervous. For the purpose of noise reduction, in this study, a perforated plate system is installed in the fan housing of range hood. From the experimental results, it is confirmed that the noise level emitted from the range hood was decreased more than 10dB(A) in all 1/3 octave bands due to the effect of noise reduction by perforated plate systems.

  • PDF

A Study on Concentration of Volatile Organic Compounds in Newly-Apartment House by Measurement (실측을 통한 신축공동주택의 주요 VOCs 물질 농도에 관한 연구)

  • Kim, Chang-Nam;Kim, Young-Kyoung;Lee, Sung-Jin
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1220-1224
    • /
    • 2008
  • Because of the high airtightness and insulation of the building, indoor environment has been largely polluted resulted from insufficient ventilation and occurrence of new air pollutant. These factors have made worse indoor air quality and caused symptoms of the SHS(Sick House Syndrome), MCS(Multi Chemical Sensitivity). The purpose of this study is to present the fundamental strategies for improving the Indoor Air Quality(IAQ) in newly-constructed apartment buildings. To investigate the concentration of indoor air pollutants such as Formaldehyde and VOCs, the field measurement were conducted.

  • PDF

A Research to Decrease Airborne Microoganism the Train (전동차내 부유 미생물 저감방안에 관한 연구)

  • Choi, Sung-Ho;Choi, Soon-Gi;Son, Young-Jin
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2895-2901
    • /
    • 2011
  • SeoulMetro(line number 1 to 4) for the first half of the year. Therefore air quality in the subway is very important. It is passengers, such as sneezing and respiratory vital activities, Suspended due to skin keratin microbial action, and Microbial contaminants such as viruses. Hypersensitivity disorders, an atopic dermatitis, infectious diseases, allergic diseases, and can cause respiratory diseases. Ministry of Environment and National Institute of Environmental Research is managed so the life bacteria. It is emerging as the occupational health problems. Introduction of an appropriate ventilation system for cooling and dehumidification is needed. In line number 2, commuting and normal trains are measured in-room floating microbes. Suspended bacteria and fungi suspended in 2011 for 85 ~ 385$cfu/m^3$, 67 ~ 98$cfu/m^3$ is lower than baseline. Suspended to prevent microbial contamination and air conditioning equipment performance is a substantial improvement. Suspended micro-organisms and the impact on passenger room ventilation is increased. Electric car how to improve air quality substantially investigated.

  • PDF

Stabilization of Soil Moisture and Improvement of Indoor Air Quality by a Plant-Biofilter Integration System (식물-바이오필터에 의한 토양수분 안정화 및 실내 공기질 향상)

  • Lee, Chang Hee;Choi, Bom;Chun, Man Young
    • Horticultural Science & Technology
    • /
    • v.33 no.5
    • /
    • pp.751-762
    • /
    • 2015
  • This study was performed to investigate the stability of soil moisture in controlling air ventilation rate within a horizontal biofilter, and to compare removal efficiency (RE) of indoor air pollutants including fine dust, volatile organic compounds (VOCs), and formaldehyde (HCHO), depending on whether dieffenbachias (Diffenbachia amoena) were planted in the biofilter. The relative humidity, air temperature, and soil moisture contents showed stable values, regardless of the presence of D. amoena, and the plants grew normally in the biofilter. REs for number of fine dust particles (PM10 and PM2.5) within the biofilter filled with only soil were at least 30% and 2%, respectively. REs for number of fine dust particles (PM10 and PM2.5) within the biofilter including the plants were above 40% and 4%, respectively. RE for fine dust (PM10) weight was above 4% and 20%, respectively, in the biofilter containing only soil or soil together with plants. In the case of the biofilter filled with only soil, REs for xylene, ethylbenzene, toluene or total VOC (T-VOC) were each more than 63%; however, REs for benzene and formaldehyde (HCHO) were above 22% and 38%, respectively. In the biofilter with the plants, REs for xylene, ethylbenzene, toluene, and T-VOC were each above 72%, and REs for benzene and HCHO were above 39%. Thus, RE of the biofilter integrated with plants was found to be higher for volatile organic compounds than for fine dust. Hence, the biofilter was very effective for indoor air quality improvement and the effect was higher when integrated with plants.

Particulate Matter and CO2 Improvement Effects by Vegetation-based Bio-filters and the Indoor Comfort Index Analysis (식생기반 바이오필터의 미세먼지, 이산화탄소 개선효과와 실내쾌적지수 분석)

  • Kim, Tae-Han;Choi, Boo-Hun;Choi, Na-Hyun;Jang, Eun-Suk
    • Korean Journal of Environmental Agriculture
    • /
    • v.37 no.4
    • /
    • pp.268-276
    • /
    • 2018
  • BACKGROUND: In the month of January 2018, fine dust alerts and warnings were issued 36 times for $PM_{10}$ and 81 times for PM2.5. Air quality is becoming a serious issue nation-wide. Although interest in air-purifying plants is growing due to the controversy over the risk of chemical substances of regular air-purifying solutions, industrial spread of the plants has been limited due to their efficiency in air-conditioning perspective. METHODS AND RESULTS: This study aims to propose a vegetation-based bio-filter system that can assure total indoor air volume for the efficient application of air-purifying plants. In order to evaluate the quantitative performance of the system, time-series analysis was conducted on air-conditioning performance, indoor air quality, and comfort index improvement effects in a lecture room-style laboratory with 16 persons present in the room. The system provided 4.24 ACH ventilation rate and reduced indoor temperature by $1.6^{\circ}C$ and black bulb temperature by $1.0^{\circ}C$. Relative humidity increased by 24.4% and deteriorated comfort index. However, this seemed to be offset by turbulent flow created from the operation of air blowers. While $PM_{10}$ was reduced by 39.5% to $22.11{\mu}g/m^3$, $CO_2$ increased up to 1,329ppm. It is interpreted that released $CO_2$ could not be processed because light compensation point was not reached. As for the indoor comfort index, PMV was reduced by 83.6 % and PPD was reduced by 47.0% on average, indicating that indoor space in a comfort range could be created by operating vegetation-based bio-filters. CONCLUSION: The study confirmed that the vegetation-based bio-filter system is effective in lowering indoor temperature and $PM_{10}$ and has positive effects on creating comfortable indoor space in terms of PMV and PPD.

The Evaluation of Occupational Health Program at a Granite Company in U.S.A. (일개 채석산업장의 산업보건프로그램 평가)

  • Yi, Sung-Eun
    • Research in Community and Public Health Nursing
    • /
    • v.13 no.3
    • /
    • pp.574-583
    • /
    • 2002
  • '채석(quarrying)'산업은 노천광산에서 광물을 캐내는 작업을 모두 포함하는 광범위한 산업을 의미한다. 1900년대에 들어오면서 채석작업에 홈연소기(channel burner)을 이용한 불꽃절개법(flame cutting)이 이용하여 근로자의 먼지 노출이 많이 감소하였다. 채석작업으로 인한 주 된 건강문제는 먼지, 소음, 진동 노출이며, 노천작업장으로 작업환경이 개방되어 있어 환경측정 및 관리가 불가능하므로 개별근로자의 먼지와 소음 노출 측정 및 예방이 중요하다. 본 연구는 미국의 일개 채석회사의 근로자 건강관리사업을 평가하였다. 연구자료는 저자가 현장 방문을 통하여 구한 자료와 연구대상 회사의 안전관리자의 의견 및 미국 산업안전보건국 전산자료를 이용하였다. 채석사업장에서 이루어지는 작업은 크게 채석작업과 실내에서 이루어지는 가공작업 및 운반과 보관이며, 미국 산업안전보건국(OSHA)의 표준산업분류(SIC)에서 1411(채석업)과 3281(채석가공업)에 해당한다<표 1>. 연구 대상 사업장에서 이루어지는 산업보건프로그램은 먼지 노출 예방을 위해 석재 채취시 물분사법(water jet quarrying)과 국소환기법을 사용하고 소음 노출 예방을 위해 귀마개를 사용하며 사고 예방을 위하여 안전모와 철모, 보안경, 안전조끼, 보호장갑, 안전끈(harness)을 착용하였다. 평가 결과로 나온 연구 대상 사업장에서 적용하여야 할 산업보건 프로그램은 첫째, 먼지 노출로 인한 건강문제를 예방하기 위하여 근로자 개별 노출 측정을 하고, 둘째 실내가공작업장의 근로자를 대상으로 한 먼지와 소음 노출 측정 및 환경측정이 필요하며, 셋째 안전관리를 위해 채석장에 안전표지판을 설치하여야 하며, 실내가공 작업장의 자동이동시스템을 작업별로 채색하여 식별을 용이하게 하여야 하겠다. 또한 이 연구 결과를 영세사업장의 산업간호프로그램인 'Clean 3D'사업에서 적용하여 우리나라 채석사업장 근로자 건강관리를 발전시켜야 하겠다.

  • PDF

A Study on Electronically Controlled R-134a Heat Pump System for a Fuel Cell Electric Vehicle (FCEV) (연료전지 자동차용 R-134a 전동식 히트펌프 시스템 개발에 관한 연구)

  • Lee, Jun-Kyoung;Lee, Dong-Hyuk;Won, Jong-Phil
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.3
    • /
    • pp.124-132
    • /
    • 2007
  • The main objective of this work is to investigate the characteristics of a heat pump system for fuel cell electric vehicle (FCEV). The present heat pump system adopts an electrically driven compressor running with R134a and uses the heat from the fuel cell stack as the heat source for the exterior heat exchanger. The experimental work has been done with various operating conditions such as different compressor speeds, fuel cell stack coolant temperatures and flow rates. The heating capacity was measured to be from 4 to 10 kW at $-20^{\circ}C$ ambient temperature, and the outlet temperature of interior heat exchanger was up to $70^{\circ}C$. After 30 seconds from start-up, the system reached a steady state and the heating capacity of 6.8 kW was acquired, and after 90 seconds, the air outlet temperature of interior heat exchanger became $35^{\circ}C$.

바닥 급기 공조의 전망

  • 김영일
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.30 no.8
    • /
    • pp.54-59
    • /
    • 2001
  • 바낙 공기 급기(UFAD, underfloor air distribution)는 사무실과 상업 건물의 공조를 위하여 바닥 하부 공간을 사용하는 혁신적인 기술이다. 북미에서는 UFAD가 기존 천장 공기 급기 방식에 비하여 많은 장점을 지니므로 그 수요가 날로 증가하고 있다. 잘 설계된 UFAD 시스템은 다음과 같은 장점을 지닌다. - 건물의 용도 변경에 따픈 유연성이 우수하므로 건물의 생애 주기 비용을 감소시킨다. - 개별 쾌적성 제어가 가능하므로 온열 쾌적성, 거주자의 만족도 그리고 생산성을 향상시킨다. - 거주자주변에 직접 선선한 공기를 공급하므로 환기 효율, 실내 공기질 그리고 건강 상태를 향상시킨다. - 이코노마이저 운전, 온도 성층화 그리고 낮은 정합 운전에 의하여 에너지 비용을 감소시킨다. - 설비 공간이 축소되고 표준 철골 구조에서는 콘크리트 구조체 변경이 가능하므로 새 건축 공법에서는 충고를 감소시킬 수 있다. 1995년까지만 해도 UFAD는 파격적인 설계 기법이라고 여겨졌지만, 이제 설계자와 건축업자들은 2004년까지 신축되는 사무용 건축품의 35%는 바닥을 높인 기법이 적용되며 이 중 반 정도가 UFAD를 채택할 것이라고 예측하고 있다. 2000년 2억불이라고 추정되던 바닥을 높이는 건축의 시장 규모가 2004년에는 최소 10억불이 되리라고 예측된다. UFAD는 기본 연구에 의한 정립된 표준화된 설계 기법과 지침이 아직 마련되지 않았음에도 불구하고 현재 설계, 시공되고 있다. 이라한 경향은 펄수적인 연구가 수행되어 관련 업계가 지식과 경험을 충분히 쌓기 전까지는 계속될 전망이다. 본고는 시스템 설계와 운영의 주요한 특징, 기존 방식과 비교하여 지니고 있는 잠재적인 장점, 한계와 기술 개발의 필요성, UFAD 기술 개발을 위하여 계속적으로 요구되는 연구 분야 등을 서술함으로써 현재 UFAD 기술에 대한 평가를 한다.

  • PDF