• Title/Summary/Keyword: 실내피난

Search Result 46, Processing Time 0.026 seconds

A Study on the Indoor Evacuation Using Matsim (활동기반 교통모형 MATSim을 이용한 실내 피난 분석)

  • Kim, Joo young;Lee, Seung jae;Ahn, Chi won
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.17 no.2
    • /
    • pp.18-31
    • /
    • 2018
  • It is important to conduct various analyzes to evacuate occupants in advance, because the disaster can cause serious injury. Therefore, it is necessary to analyze all the predictable scenarios that may occur. In this study, we propose a method to analyze the evacuation of indoor disaster using activity - based transport model MATSim. We have developed the university building as target area and simulated about 5,000 occupants. The analysis scenarios are set as basic evacuation conditions, exit closures and emergency stair closures. As a result of analysis of each scenario, the evacuation time was analyzed to be about 5:40(340s) in the base scenario, increased by 15% in the scenario 2 and increased by 23% in scenario 3. As a result of this study, we suggest that it is important to manage illegal obstacles of emergency stairs for rapid evacuation. Therefore, this study can contribute to the effective disaster prevention strategy of the building.

A Study on the Fire Drill Behavior Characteristics in Rehabilitation Center for Visually Impaired Persons (시각장애인 복지관의 화재 피난행태 특성분석 연구)

  • Lee, Jeong-Soo;Kwon, Heung-Soon;Kim, Eung Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.8
    • /
    • pp.5646-5653
    • /
    • 2015
  • This study focused on the architectural, interior and management guidelines in rehabilitation center for visually impaired persons. For these purposes, we reviewed the movement behaviors and the characteristics of fire drill in rehabilitation center for visually impaired persons. The results are as follows. : First, the liner circulation paths and interior landmarks are recommended, and dwelling units and program rooms should be located in ground floor for barrier free evacuation. Second, It is important to establish continuous handrail, variations of paving patterns and materials, good color definition, tactile informations and directional sound. Third, it is necessary to serve more specified architectural, interior, and management guidelines according to impaired prototypes.

A study on the Means of Egress Codes for Interior Architecture in the United States - Focused on Evacuation Elements in the Interior Architectural Design - (미국의 실내건축 피난 규정에 관한 연구 - 실내건축계획에 있어 피난 요소를 중심으로 -)

  • Kim, Young-Sung;Cho, Sung-O
    • Korean Institute of Interior Design Journal
    • /
    • v.27 no.3
    • /
    • pp.24-32
    • /
    • 2018
  • The law reflects the situation of the times, understands the society, and shows the will of the state and the community. The Means of Egress should be maintained from design to construction, supervision, as well as use, in order to protect the lives and property of the residents as well as the safe use of the facilities. However, Interior Architects are think that evacuation and safety regulations are complex elements that change frequently and may inhibit the idea of design. The purpose of this study is to propose a design method for the use of safe facilities in the interior architectural design on the evacuation regulations affecting the actual design by the IBC(the International Building Code) and NFPA(National Fire Protection Association) LSC (Life Safety Code). The research method is to investigate and analyze the provisions related to the evacuation of interior architecture in the US and to understand the current regulations and the evacuation regulations. We suggest to design method to the details of the hallway, corridors, aisle accessway, door way, exit path, In particular, the design of furniture, tables and chairs layout that could be obstacles to evacuation situations is presented.

A Fire Computer Simulation of Inner Space with Fire Shutters and Refuge Stairs (방화셔터와 피난계단이 존재하는 실내 환경의 화재 컴퓨터 시뮬레이션)

  • Yoo, Doo-Yul;Yang, Jung-Min
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.11
    • /
    • pp.1617-1624
    • /
    • 2013
  • This paper analyzes the relation between fire shutters and fire spread by conducting fire simulation on inner space with fire shutters. Using Fire Dynamics Simulator (FDS), a commercial fire simulation software, the simulation is done on an ideal inner robby, where fire size and the open/close of fire shutters are varied. Our simulation environment can derive significant fire parameters such as temperature variation of fire room walls and entrances of refuge stairs, variation of carbon dioxide, and soot spread. According to the simulation results, temperature and carbon dioxide distribution in refuge stairs have little dependence on vent open or close, but the part close of fire shutters blocks soot inflow to refuge stairs.

Risk Evaluation and Analysis on Simulation Model of Fire Evacuation based on CFD - Focusing on Incheon Bus Terminal Station (CFD기반 화재 대피 시뮬레이션 모델을 적용한 위험도 평가 분석 -인천터미널역 역사를 대상으로)

  • Kim, Min Gyu;Joo, Yong Jin;Park, Soo Hong
    • Spatial Information Research
    • /
    • v.21 no.6
    • /
    • pp.43-55
    • /
    • 2013
  • Recently, the research to visualize and to reproduce evacuation situations such as terrorism, the disaster and fire indoor space has been come into the spotlight and designing a model for interior space and reliable analysis through safety evaluation of the life is required. Therefore, this paper aims to develop simulation model which is able to suggest evacuation route guidance and safety analysis by considering the major risk factor of fire in actual building. First of all, we designed 3D-based fire and evacuation model at a subway station building in Incheon and performed fire risk analysis through thermal parameters on the basis of interior materials supplied by Incheon Transit Corporation. In order to evaluate safety of a life, ASET (Available Safe Egress Time), which is the time for occupants to endure without damage, and RSET (Required Safe Egress Time) are calculated through evacuation simulation by Fire Dynamics Simulator. Finally, we can come to the conclusion that a more realistic safety assessment is carried out through indoor space model based on 3-dimension building information and simulation analysis applied by safety guideline for measurement of fire and evacuation risk.

A Study on Behavior Characteristics through Way Decision of Indoor Evacuation (실내 피난경로 선택 특성)

  • Hwang, Kwang-Il;Sim, Young-Hoon;Kim, Hyun-Sung
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2014.10a
    • /
    • pp.268-269
    • /
    • 2014
  • The purpose of this research is to investigate characteristics for way decision of indoor evacuation, when humans are faced on disaster such as fire, earthquake and explosion. As a research, it is found that majority of evacuation behavior characteristics was in a fire, disaster.

  • PDF

Design and Implementation of LoRa-based Emergency Exit Guide System (LoRa 기반 피난 유도 체계의 설계 및 구현)

  • Shin, Jaejun;Eun, Seongbae;So, Sun-Sup;Kim, Byungho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.4
    • /
    • pp.569-574
    • /
    • 2018
  • This paper proposes and implements a LoRa-based emergency exit guide system which can direct the optimal refuge path accounting for the real state of the fires. Each 4-way emergency exit guide sign presents a right direction through one of four LED signs toward the possible exit dynamically calculated by the shortest path algorithm. We constructed a simulation environment with 8 spots of the emergency exit guide signs and 2 exits, which can simulate variant cases of fire accidents, and showed that the proposed algorithm can presents the right guidance for each emergency exit guide sign. We also evaluated the performances of LoRa-based wireless communications using a self developed communication module in the various indoor and outdoor environments. The proposed system can be applied to small and medium sized buildings as well as larger ones in terms of cost efficiency, in which there's no needs to invest for the complex equipments except only sensors and emergency exit guide signs.

Optimal Deployment for Evacuation Safety Zone at Intermodal Transfer Station (복합환승센터 피난대피구역 적정 배치 방법론 개발)

  • You, So-Young;Jeong, Eunbi
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.18 no.1
    • /
    • pp.27-42
    • /
    • 2019
  • It is not easy to evacuate when people face with emergency situation in deep underground space because space perception and synthetic judgement are readily lowered. In stead of evacuating safely outside within the given time, evacuation safety zone is required to be designed and installed. In this study, PATS (Pedestrian movement based Assessment Toolkit for Simulation) is applied to build a comprehensive and analytic framework for seeking the optimal (or proper) numbers and locations of evacuation safety zone. With two scenarios of emergency situation at intermodal transfer center with the 6 floor in underground, the problematic location on the evacuation path has been identified and the proper locations has been presented.

Implementation of Emergency Evacuation Support System in Panic-type Disaster (돌발성 재해에 대비한 긴급 피난 지원 시스템의 구현)

  • Hwang, Jun-Su;Choi, Young-Bok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.7
    • /
    • pp.1269-1276
    • /
    • 2016
  • Recently, natural disasters including earthquakes, tsunamis, floods, and snowstorms, in addition to disasters of human origin such as arson, and acts of terror, have caused numerous injuries and fatalities around the world. During such disasters, victims need to obtain information such as the exact location of the disaster and appropriate evacuation routes in order to relocate to safe areas. In this study, We propose the algorithm for Emergency Rescue Evacuation Support System(ERESS). In case a emergency disaster occurs, ERESS is possible to detect it quickly using through the movement of people. The mobile terminal analyzes behavior and location of indoor pedestrian. And it sends the result to the server. The server determines whether an emergency situation occurred or not based on the received transmission information. When an emergency situation occurs, the server will notify it to the mobile terminal. Then, indoor pedestrian conduct emergency evacuation using mobile terminal.

Analysis on Activation Characteristic of Heat Detectors in a Compartment Fire (실내화재에서의 열감지기 동작특성 분석)

  • Ryu, Hocheol
    • Journal of the Society of Disaster Information
    • /
    • v.10 no.4
    • /
    • pp.598-608
    • /
    • 2014
  • The first operation of alarm system starts at a detector. And the largest effect is produced on the operation of detector by the fire source position and installation position. Nevertheless, the Korean standard for the installation of detector only specifies matters of fire detector installation according to area and height, without consideration of installation position and fire source position. Therefore, this study carried out a fire test in consideration of detector installation position and fire source position (5 places) in order to minimize casualties owing to the fast operation of fire detector when a fire occurred. Considering that it took the longest time for a detector close to a wall to work in the results of this test, it was possible to find that a minimum clearance to the wall was required.