• Title/Summary/Keyword: 실내시험

Search Result 1,528, Processing Time 0.029 seconds

Cooling Control of Greenhouse Using Roof Window Ventilation by Simple Fuzzy Algorithm (단순 퍼지 제어기법을 이용한 온실의 천창환기에 의한 냉방제어)

  • Min, Young-Bong;Yoon, Yong-Cheol;Huh, Moo-Ryong;Kang, Dong-Hyun;Kim, Hyeon-Tae
    • Journal of agriculture & life science
    • /
    • v.44 no.4
    • /
    • pp.69-77
    • /
    • 2010
  • Fuzzy control is widely used for improving temperature control performance as controlling ventilation in greenhouse because the technique can respond more flexibly to the outside air temperature and wind speed. By pre-studied PID and normal fuzzy control this study was performed to obtain the fundamental data that can be established in better greenhouse ventilation control method. The temperature control error by the simple fuzzy control was $1.2^{\circ}C$. The accumulated operating size of the window and the number of operating were 84% and 13, respectively. These showed equivalent control performance with pre-studied result that control error. The accumulated operating size of the window and the number of operating were 75% and 12, respectively. The proposed fuzzy technique was simple control logic method compared with step and PID control methods, but it showed equivalent performance. Therefore, the proposed simple fuzzy control method could be used in micro controller of small programmable memory size and many applications.

Relationship between the P Wave Velocity, Static Elastic Modulus, and Dynamic Elastic Modulus of Rocks (암종별 P파 속도, 정탄성계수 및 동탄성계수의 상관관계 분석 연구)

  • Moon, Seong-Woo;Kim, Hyeong-Sin;Yun, Hyun-Seok;Seo, Yong-Seok
    • The Journal of Engineering Geology
    • /
    • v.29 no.3
    • /
    • pp.339-349
    • /
    • 2019
  • The relationship between the P wave velocity, static elastic modulus, and dynamic elastic modulus of different rock types was investigated to identify the distributive characteristics of the dynamic elastic modulus. Laboratory and in situ test results from 1,646 rock specimens, which are obtained for design and construction of structure, were analyzed, and grouped into three key rock types: gneiss, granite, and sandstone. These relationships were verified by comparing them with the results from previous studies. The gneiss samples exhibit a linear P wave velocity-static elastic modulus relationship, whereas the granite and sandstone samples exhibit exponential relationships. Their coefficient of determination ($R^2$) values are all in the 0.491-0.642 range, and are similar to those obtained in previous studies. The relationship between the static and dynamic elastic modulus exhibits a linear relationship for all rock types, yielding a coefficient of determination in the 0.543-0.676 range. The relationship between the P wave velocity and static elastic modulus follows an exponential regression for all rock types, with a high coefficient of determination that is in the 0.875-0.940 range.

Electroantennogram Responses of Spodoptera frugiperda Males (Lepidoptera: Noctuidae) to Sex Pheromone Compounds (열대거세미나방 성페로몬 성분에 대한 수컷의 촉각 반응)

  • Cho, Jum Rae;Kim, Jeong Hwan;Seo, Bo Yoon;Seo, Meeja;Lee, Gwan Seok
    • Korean journal of applied entomology
    • /
    • v.60 no.4
    • /
    • pp.363-367
    • /
    • 2021
  • This study was conducted to investigate the EAG (electroantennogram) response of Spodoptera frugiperda male to sex pheromone compounds and whether or not S. frugiperda male adults would undergo double mating. The EAG response of S. frugiperda male adult to Z9-14:Ac increased in a dose-dependent as the dose increased. Among the 7 sex pheromone components investigated, male EAG recording was the highest to Z9-14:Ac. The EAG response of S. frugiperda male adult to the mixed sex pheromone component was greater than that to the single component. Male adults of S. frugiperda were capable of double mating under laboratory condition, and the secondary mating rate increased to 72.2% compared to the 58.3% of primary mating rate. The EAG response of mated S. frugiperda male adult was not different from that of unmated S. frugiperda male. In the net house test with sex pheromone lure, mated male adults were not captured during the test period. Also, strangely, unmated male adults were not captured even in a trap equipped with virgin female adults, although the antennae of mated male adult were responded to the sex pheromone component in the laboratory. Probably, it is thought that the mated male adults may not have been caught in the trap be due to flight ability which has been decreased after mating. The field attractiveness of S. frugiperda male adults to sex pheromones remains to be further elucidated.

Analysis of Sand Water Ratio and Drying Unit Weight Using Flat TDR System (Flat TDR 시스템을 이용한 모래의 함수비와 건조단위중량 분석)

  • Lee, Junesung;Kim, Daehyeon
    • The Journal of Engineering Geology
    • /
    • v.31 no.3
    • /
    • pp.333-342
    • /
    • 2021
  • In this study was conducted to measure the water content and dry unit weight of the ground using TDR (Time Domain Reflectometry) in order to supplement the problems of the conventional compaction management method. The Flat TDR system is a device that does not cause ground disturbance, and in order to verify the measured values, the dry density and water content were measured for samples of the ground subject at 7 sites other than Jumunjin Standard Temple. The water content section was divided into 6 sections of 3, 6, 9, 12, 15, and 18%, and the experimental results were confirmed according to the unified classification method. As a result of the indoor experiment, the water content showed an error of about 0.7% for the SP sample and about 1.3% for the SM sample. In addition, the dry unit weight confirmed an error of about 7% for the SP sample and about 5% for the SM sample. It was confirmed that stable values were derived in sandy or silty sandy ground except for clay or gravel. Through the experimental results, it was confirmed that the measured values of the flat TDR system derive similar values to the existing traditional compaction management method, and it was determined that the flat TDR equipment was suitable for construction sites that require quick constructability and economic feasibility.

The Condition Evaluation of Mortar Parts of Stupa of State Preceptor Jigwang from Wonju Beopcheonsa Temple Site by Half Cell Potential Measurement - with Focus on the Mortar Parts the RoofStone - (반전위 측정을 통한 원주 법천사지 지광국사탑 모르타르 복원부위 상태평가 연구 - 옥개석 모르타르 복원부위를 중심으로 -)

  • Lee, Tae Jong;Cho, Ha Jin;Park, Hee Jeong;Chae, Seung A
    • Journal of Conservation Science
    • /
    • v.34 no.6
    • /
    • pp.503-515
    • /
    • 2018
  • Stupa of State Preceptor Jigwang at Beopcheonsa temple site, Wonju, was conserved and restored in 1957. It was necessary to assess the degree of damage to the used mortar and to provide objective data on the necessity of its removal. Therefore, the HCP(half-cell potential) measurement used in concrete fields was applied. Multi-regression analysis of HCP data, following the rapid corrosion test of the roofstone mortar used by the rebar, resulted in a high correlation of HCP values(0.86), depending on the amount of corrosion and cover depth used for the steel bar. As a result, high correlation values(0.86) for the coefficients of determination were derived. The showed that the measurement of the wet conditions -431 to -663 mV on the roofstone indicated a corrosion damage rate of 90% or more after removal and restoration.

Suggestion of Deterioration Curve for New-type Coating on Atmospheric Environment by Acceleration Corrosion Test (부식촉진 실험을 통한 대기환경에서 신설 도장계의 노화곡선 제안)

  • Jeong, Young-Soo;Kim, Min-Jeong;Jeon, Seok-Hyeon;Ahn, Jin-Hee;Kim, In-Tae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.2
    • /
    • pp.75-83
    • /
    • 2019
  • In this study, to propose the deterioration curves of urethane, ceramic, polysiloxane and fluorocarbon coating for the steel bridge, an accelerated corrosion tests were carried out. The each coating system wes applied on the top of the specimens, and circular initial defects were introduced with different diameters with 0.5, 1.0, 3.0, 5.0 mm. An accelerated corrosion test condition was used to simulate severe corrosive environment depending on ISO 20340. The deterioration curve of each coating type was evaluated based on deteriorated area from the circular defects. In order to evaluate the coating service life of installed steel bridge using deterioration curve, the acceleration coefficient was calculated at correlation between ISO 20340 and corrosivity categories by ISO 9223 based on field corrosion rate. From test results, the propagation rate of coating deterioration area was different to diameter of circular defects. In case of urethane coating, the coating service lifes of 3% deterioration area was evaluated in 31.8, 15.8, 9.9 and 3.9 years with C2, C3, C4 and C5 category.

Field Application and Maintenance of sidewalk concrete block for PV Power Generation (태양광 발전을 위한 보도형 콘크리트 블록의 현장 적용과 유지관리)

  • Kim, Bong-Kyun;Kim, Yun-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.5
    • /
    • pp.75-83
    • /
    • 2019
  • In order to fulfill the obligation to voluntarily reduce greenhouse gas emissions under the Paris Climate Agreement, the proportion of coal and nuclear power generation is reduced worldwide and national efforts are being made to spread renewable energy including solar power generation. Korea also intends to increase the proportion of renewable energy generation to 30~35% by 2040 by introducing laws and regulations. In addition, while the country is trying to apply solar power generation to sidewalks and roads, there is no research related to it in Korea. Therefore, as a precedent study to develop solar power generation roads, solar power generation concrete blocks applicable to sidewalks and plazas were developed and the applicability was evaluated by constructing them on the site. As a result of indoor experiment, compressive strength was measured by 25.5~35.7MPa and flexural strength was measured by 5.1~10.5MPa, which showed that all domestic standards were satisfied. However, the higher the unit cement amount, the lower the strength was measured according to the mixing of the broken fine aggregate. The absorption rate was 5.7%, which satisfied the domestic standard of 7% or less. As a result of the freeze-thawing test, the reduction rate of the compressive strength after 100 cycles was up to 6.3%. As a result of measuring the settlement amount after construction, the maximum of 2.498mm was measured and irregular settlement occurred in the overall area, which is because the resolution of the sand layer was poor during construction. Maintenance techniques of sidewalk concrete block and solar panel need to be established more efficiently through long-term operation in the further.

Borehole Elemental Concentration Logs: Theory, Current Trends and Next Level (암석구성성분검층: 원리, 연구동향 및 향후 과제)

  • Shin, Jehyun;Hwang, Seho
    • Geophysics and Geophysical Exploration
    • /
    • v.22 no.3
    • /
    • pp.149-159
    • /
    • 2019
  • Borehole elemental concentration logging, measuring neutron-induced gamma rays by inelastic scattering and neutron capture interactions between neutron and formation, delivers concentrations of the most common elements found in the minerals and fluids of subsurface formation. X-ray diffraction and X-ray fluorescence analysis from core samples are traditionally used to understand formation composition and mineralogy, but it represents only part of formations. Additionally, it is difficult to obtain elemental analysis over the whole intervals because of poor core recovery zones such as fractures or sand layers mainly responsible for groundwater flow. The development of borehole technique for in situ elemental analysis plays a key role in assessing subsurface environment. Although this technology has advanced consistently starting from conventional and unconventional resources evaluation, it has been considered as exclusive techniques of some major service company. As regards domestic research and development, it has still remained an unexplored field because of some barriers such as the deficiency of detailed information on tools and calibration facility for chemistry and mineralogy database. This article reviews the basic theory of spectroscopy measurements, system configuration, calibration facility, and current status. In addition, this article introduces the domestic researches and self-development status on borehole elemental concentration tools.

Evaluation of Soil-Water Characteristic Curve for Domestic Bentonite Buffer (국내 벤토나이트 완충재의 함수특성곡선 평가)

  • Yoon, Seok;Jeon, Jun-Seo;Lee, Changsoo;Cho, Won-Jin;Lee, Seung-Rae;Kim, Geon-Young
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.17 no.1
    • /
    • pp.29-36
    • /
    • 2019
  • High-level radioactive waste (HLW) such as spent fuel is inevitably produced when nuclear power plants are operated. A geological repository has been considered as one of the most adequate options for the disposal of HLW, and it will be constructed in host rock at a depth of 500~1,000 meters below ground level with the concept of an engineered barrier system (EBS) and a natural barrier system. The compacted bentonite buffer is one of the most important components of the EBS. As the compacted bentonite buffer is located between disposal canisters with spent fuel and the host rock, it can restrain the release of radionuclides and protect canisters from the inflow of groundwater. Because of inflow of groundwater into the compacted bentonite buffer, it is essential to investigate soil-water characteristic curves (SWCC) of the compacted bentonite buffer in order to evaluate the entire safety performance of the EBS. Therefore, this paper conducted laboratory experiments to analyze the SWCC for a Korean Ca-type compacted bentonite buffer considering dry density, confined or unconfined condition, and drying or wetting path. There was no significant difference of SWCC considering dry density under unconfined condition. Furthermore, it was found that there was higher water suction in unconfined condition that in confined condition, and higher water suction during drying path than during wetting path.

A Basic Study on Borehole Breakout under Room Temperature and High Temperature True Triaxial Compression (상온 및 고온 하 진삼축압축실험을 이용한 시추공의 파괴 거동 기초 연구)

  • Yoon, Jeonghwan;Min, Ki-Bok;Park, Eui-Seob;Jung, Yong-Bok
    • Tunnel and Underground Space
    • /
    • v.30 no.6
    • /
    • pp.559-572
    • /
    • 2020
  • This paper performs laboratory experiments for borehole stability considering temperature and true triaxial stress condition, and observes a thermo-mechanical behavior of the rock under stress and temperature conditions of deep underground. China yellow sandstone and Hwangdeung granite specimens were used to perform a true triaxial compression test. Mechanical tests were carried out under nine confining pressure conditions, and thermo-mechanical tests using granite samples were carried out under six confining pressure conditions at 60-100℃. In the mechanical tests, maximum principal stress at borehole breakout was proportional to intermediate principal stress. In the thermo-mechanical tests, it was confirmed that thermal stress is added to the stress field of the borehole with the increase in temperature, resulting in additional breakout progress. To analyze the results of the laboratory experiment, Mogi-Coulomb failure criterion was used. The results of traditional triaxial compression test on cylindrical specimens and borehole breakout under true triaxial compressions matched well with Mogi-Coulomb failure criterion.