Evaluation of Rain Shelters by Ventilation Rate and Inside Air Temperature (환기율 및 실내온도 해석에 의한 간이시설의 효율성 평가)

  • 손정익;김문기;남상운;이동근;유인호;윤남규;이재영
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1994.05a
    • /
    • pp.75-78
    • /
    • 1994
  • 비가림 시설은 경제적이고 간편하기 때문에 실용적으로 많이 사용되는 재배방법으로서, 하절기 재배를 위한 간이시설 중의 하나이다. 그러나 고온기의 시설재배이기 때문에 환기를 통하여 온도상승을 억제할 필요가 있다. 따라서 관행의 비가림 시설에 뒤지지 않는 작업성을 유지하면서 효율적인 환기로 온도상승을 억제할 수 있는 시설 형태의 개발이 필요하다. 본 연구에서는 간이시설의 효율적 형태의 설정을 위하여 특징적으로 분류한 3형태의 간이시설에 대하여 환기율 및 실내온도 해석을 통하여 효율성을 검토하였다. (중략)

  • PDF

A Study on the Heating and Cooling Energy Load Analysis of the KNU Plant Factory (KNU 식물공장의 냉난방 에너지 부하 해석에 관한 연구)

  • Lee, Chan-Kyu;Kim, Woo-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.4
    • /
    • pp.1419-1426
    • /
    • 2012
  • The heating and cooling energy load of the KNU plant factory was analyzed using the DesignBuilder. Indoor temperature set-point, LED supplemental lighting schedule, LED heat gain, and type of double skin window were selected as simulation parameters. For the cases without LED supplemental lighting, the proper growth temperature of lettuce $20^{\circ}C$ was selected as indoor temperature set-point together with $15^{\circ}C$ and $25^{\circ}C$. The annual heating and cooling loads which are required to maintain a constant indoor temperature were calculated for all the given temperatures. The cooling load was highest for $15^{\circ}C$ and heating load was highest for $25^{\circ}C$. For the cases with LED supplemental lighting, the heating load was decreased and the cooling load was 6 times higher than the case without LED. In addition, night time lighting schedule gave better result as compared to day time lighting schedule. To investigate the effect of window type on annual energy load, 5 different double skin window types were selected. As the U-value of double skin window decreases, the heating load decreases and the cooling load increases. To optimize the total energy consumption in the plant factory, it is required to set a proper indoor temperature for the selected plantation crop, to select a suitable window type depending on LED heat gain, and to apply passive and active energy saving technology.

A Study on the Foundation of the Standard of Temperature and Humidity for Preventing Condensation in Apartment Housings (공동주택 세대내 결로방지 설계를 위한 실내외 온습도 기준 수립 연구)

  • Hwang, Ha-Jin;Kim, Jong-Yeop;Lee, Jong-Sung
    • Land and Housing Review
    • /
    • v.2 no.3
    • /
    • pp.269-276
    • /
    • 2011
  • Recently, the chance of dew condensation in apartment buildings is increasing because of several reasons. For example, ventilation rate has been decreased because of high-insulations and airtightness for saving energy. Besides, the humidity has been made by drying washes, cooking and bathing inside of apartment buildings. However, there is lack of resonable design criteria for preventing condensation in real life and real surroundings. Therefore, this study is aimed at making a resonable design criteria of preventing condensation by measuring the indoor temperature and humidity in real life. In addition to this, it is aimed at making a resonable outdoor condition and classifying regions by using weather data. The following are the results. The interior criterion for condensation was set up $25^{\circ}C$ and a relative humidity of 55%. The outdoor criterion for condensation was set up $20^{\circ}C$, $-15^{\circ}C$, and $10^{\circ}C$ respectively for the hard frost, middle, and southern areas.

CFD Analysis Based Optimal Temperature Measurement (CFD 해석 기반 실내 최적 온도 계측)

  • Lee, Min-Goo;Park, Yong-Kuk;Jung, Kyung-Kwon;Yoo, Jun-Jae
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.05a
    • /
    • pp.735-738
    • /
    • 2011
  • This paper proposed the method to find out the optimal sensing point of temperature in test-bed with the sensor of temperature, such as real residence. We selected optimal locations by checking temperature change which was simulated by the means of CFD (Computational Fluid Dynamics) and the variation of air flow. We installed 30 temperature sensors in real place. After that, we compared the real one with the result of simulation.

  • PDF

Effect of Foliage Plant Pachira aquatica on the Change of Indoor Temperature and Humidity (관엽식물 파키라가 실내 온·습도 변화에 미치는 영향)

  • Son, Ki-Cheol;Kim, Mi-Kyoung;Park, So-Hong;Chang, Myoung-Kap
    • Horticultural Science & Technology
    • /
    • v.16 no.3
    • /
    • pp.377-380
    • /
    • 1998
  • In order to investigate the effects of foliage plants on the changes of indoor thermal- and hygro- environments, experiments were carried out in two rooms with similar physical factors. Changes of indoor environmental parameters according to the existence of plants, their arrangement methods, and the existence of wrapseal for protecting the loss of water from the pot soil were measured during certain periods in winter and summer season, using Pachira aquatica which is widely used as indoor plant and has higher photosynthetic and traspiration rate than other foliage plants. The data suggested that the existence of plants didn't affect directly on the indoor thermal environment, while relative humidity increased about 3~5%, regardless of season, by putting plants which had volume equivalent to 2.4% of room volume. In summer, there was no difference in increasing effect of relative humidity between parallel arrangement with window and spread arrangement in the room, but in winter the former arrangement was more effective than the later.

  • PDF

Simnlation of a Thermal Behavior in Solar Heating and Cooling System with respect to Demand Room Temperature (실내 설정온도에 따른 태양열 냉난방 시스템의 동적 거동 해석)

  • Jang, H.Y.;Lee, S.B.;Chung, K.T.;Suh, J.S.
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3446-3451
    • /
    • 2007
  • The thermal behavior of a building in response to heat input from an active solar space heating system is analysed to determine the effect of the variable storage tank temperature on the cycling rate, on and off temperature of a heating cycle and on the comfort characteristics of room air temperature. A computer simulation of the system behavior has been performed and verified by comparisons with various parameters. Especially, this study is focused on the effect of the system's performance when subjected to dynamic cooling loads. The heat input to the absorption system is provided by an array of solar collectors that coupled to a thermal storage tank.

  • PDF

The Steady-State Operating Characteristics of a Catalytic Combustor Using Methanol Mixture (메타놀 예혼합기를 이용한 촉매연소기의 정상상태 운전특성)

  • ;伊藤獻一
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.6
    • /
    • pp.1223-1230
    • /
    • 1989
  • 본 연구에서는 이러한 관점으로부터, 개방식 연촉매치를 상정하여, 백금의 모노리스형 촉매를 이용한 메타놀예%%합형 촉매연소기의 정상운전의 실용성에 관한 실험 및 수치계산을 행하였다. 먼저 촉매연소기의 온도분포 및 배기가스 온도분포를 파악하고, 촉매연소기의 실용성을 평가하기 위하여 실내환경예측을 행하였다. 또한 실험만으로는 연소기의 여러가지 운전조건에 관한 전테이타를 얻는 것은 어렵다. 이 때문에 본 연구에서는, 이전의 연구에서 이용한 계산과 같이 메타놀이 완전연소하는 는 것으로 보고 중간산하물의 생성을 무시한 1차원 수치계산모델로 연소특성, 배기가 스의 배출특성등의 예측을 하였으며, 명종 운전 파라메타의 설정한계 등에 대하여 검토를 행하였다.

A Fire Computer Simulation of Inner Space with Fire Shutters and Refuge Stairs (방화셔터와 피난계단이 존재하는 실내 환경의 화재 컴퓨터 시뮬레이션)

  • Yoo, Doo-Yul;Yang, Jung-Min
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.11
    • /
    • pp.1617-1624
    • /
    • 2013
  • This paper analyzes the relation between fire shutters and fire spread by conducting fire simulation on inner space with fire shutters. Using Fire Dynamics Simulator (FDS), a commercial fire simulation software, the simulation is done on an ideal inner robby, where fire size and the open/close of fire shutters are varied. Our simulation environment can derive significant fire parameters such as temperature variation of fire room walls and entrances of refuge stairs, variation of carbon dioxide, and soot spread. According to the simulation results, temperature and carbon dioxide distribution in refuge stairs have little dependence on vent open or close, but the part close of fire shutters blocks soot inflow to refuge stairs.

A Study on the State feedback with Integral Control for a Variable Air Volume Unit (가변 풍량 유닛에 대한 적분기를 가진 상태 궤환 제어에 관한 연구)

  • 박세화
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.1 no.2
    • /
    • pp.9-14
    • /
    • 2000
  • State feedback with integral control for a variable air volume(VAV) unit which is recently taken notice of for the energy efficiency and saving in the building is studied to investigate the performance of the digital control methodology for the possible practical application. The digital controller which acquires the targat zone temperature and the air flow rate of the supplied air to the zone controls the opening of the damper in the VAV unit. Simulation results are performed for the conditions including reference changes and external thermal variations. In the simulation. simplified conditioned zone and the damper actuator modelling is considered. and relationships between controller gain Parameters and the system dynamics are investigated.

  • PDF