• Title/Summary/Keyword: 실내석면농도

Search Result 14, Processing Time 0.022 seconds

Airborne Asbestos Concentrations of Dental Laboratories in One Metropolitan City (치과기공소의 공기 중 석면농도 분포에 관한 연구 -일개 광역시를 중심으로-)

  • Jung, In-Ho
    • Journal of the Korea Convergence Society
    • /
    • v.2 no.1
    • /
    • pp.31-36
    • /
    • 2011
  • This study was performed to investigate the problems of using asbestos for dental technicians. Samples for analysing were sampled by personal sampler in 40 sampling points of 10 dental laboratories in Daegu city from December 2010 to January 2011 and counted with phase contrast microscopy. The results were as follows: 1. Asbestos concentration(geometric mean) of 40 sampling points in 10 dental laboratories was 0.0061 f/cc and it was under recommended industrial and indoor air standard, but the concentration of asbestos in only two dental laboratories was over indoor recommended standard. 2. The concentration of asbestos in processing room and burnout room was 0.0099 f/cc and 0.0037 f/cc, respectively. 3. The mean concentration(GM) of asbestos by kinds of casting ring liners was 0.0159 f/cc in dental laboratories using industrial asbestos, 0.0104 f/cc in them using asbestos containing ring liners, and 0.0026 f/cc in them using non-asbestos ring liners. Casting ring liners using in dental laboratories should be substituted with non-asbestos liners, because most of dental laboratories were using asbestos containing ring liners and a few of them showed higher concentration than recommended standard.

건축물 석면관리 가이드라인 제정.시행

  • 대한설비건설협회
    • 월간 기계설비
    • /
    • s.226
    • /
    • pp.53-57
    • /
    • 2009
  • 그동안 많은 논란이 있었던 석면문제가 또다시 도마 위에 올랐다. 최근 아기에게 바르는 파우더를 비롯하여 화장품 등에까지 석면공포가 확산됨에 따라 환경부는 석면이 주로 건축자재(80% 이상)에 사용된 만큼 국민건강 보호를 위해 건축물에 사용된 석면의 안전한 관리가 무엇보다 중요하다고 판단, 가이드라인을 제정, 시행에 들어갔다. 가이드라인의 주요 내용은 $\Delta$건축물에 사용된 석면함유 설비 또는 자재를 조사하여 석면지도 작성 및 6개월마다 훼손 여부 평가 관리 $\Delta$석면 해체 제거작업 과정에서 석면이 비산되지 않도록 주변 대기 중 석면농도 0.01개/cc(실내공기질 권고기준) 기준 설정 $\Delta$석면 해체 제거 작업 및 폐석면 처리 시 안전한 석면관리를 위한 준수사항 등이다. 이번 가이드라인은 건축물 사용단계부터 철거 폐기까지 전 생에에 걸친 석면 관리 방법 및 기준 등을 포함하고 있어 건축물 이용자, 철거지역 인근 주민의 석면 노출 차단에 기여할 것으로 기대된다. 환경부는 가이드라인을 자치단체, 다중이용시설 관리자, 건축물 철거업체 등을 통해 널리 알리는 한편, 노동부 등 관계부처와 함께 관련제도 보완 등 건축물 석면관리 개선방안을 오는 6월까지 마련할 계획이다.

  • PDF

A study on the survey and reduction of indoor asbestos concentration (실내의 석면농도 실태 조사 및 저감에 관한 연구)

  • Seo, Byong-Won;Lee, Ju-Hwa;Park, Jihoon;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.3
    • /
    • pp.325-337
    • /
    • 2014
  • The research on the actual condition of indoor asbestos concentration in Korea has not been thoroughly accomplished up to now. In this research the ratio of asbestos-containing buildings and indoor asbestos concentration was studied. This investigation was conducted in 2012 and 2013 and buildings were categorized based on region, building type by use, existing space(ground or basement), and construction year, respectively. Also the indoor asbestos concentration change was monitored to evaluation the efficiencies of two types of asbestos-concentration abatement devices. As a result, the ratio of asbestos-containing buildings in Seoul was largely decreased. The ratio of asbestos-containing buildings was higher in hospitals and schools regionally and in ground buildings than in basement. The average indoor asbestos concentrations were 0.0011, 0.0008 piece/cc in 2012 and 2013 investigation, respectively. Those values were much lower than standards(0.01 piece/cc), therefore the threat of indoor asbestos concentration might be negligible. In asbestos-concentration abatement experiments, the circulation velocity of ventilator were changed 2-6.7 m/sec. With 6.7 m/sec of velocity of ventilator, the concentration of indoor asbestos was fluctuated and maximum value was 2.4 piece/cc. With 4.5 and 2 m/sec of velocities of ventilator, the maximum concentration of indoor asbestos was fluctuated and maximum value was 0.9 piece/cc. This indicated that the concentration of indoor asbestos was decreased partly due to the free drop of asbestos. From these results, the proper velocity of ventilator seems to be between 4.7 and 6.5m/sec under this circumstance and further research is required. These research results may be used to guideline of asbestos management policy.

A Study on Characteristics of Airborne Asbestos Concentrations at Demolition Sites and Surrounding Areas of Asbestos Containing Buildings in Seoul (서울시내 건축물 석면해체·제거 사업장 및 주변에서의 공기 중 석면농도 특성에 관한 연구)

  • Lee, Jinhyo;Lee, Suhyun;Kim, Jeongyeun;Kim, Jihui;Chung, Sooknye;Kim, Jina;Kim, Iksoo;Eo, Soomi;Jung, Kweon;Lee, Jinsook;Koo, Jayong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.6
    • /
    • pp.434-441
    • /
    • 2014
  • This study is purposed to measure airborne asbestos concentrations at demolition sites and surrounding areas of asbestos containing buildings in Seoul and examine whether the measurement results correspond with allowable exhaust standard for asbestos of the Asbestos Safety Control Act. The airborne asbestos concentrations for 37 sites were below the detection limit ($7fiber/mm^2$) in 101 (35%) out of 288 samples. The whole average airborne asbestos concentration in 37 sites was $0.003{\pm}0.002f/cc$(max 0.0013 f/cc) and almost the whole airborne asbestos concentrations were satisfied with allowable exhaust standard for asbestos, 0.01 f/cc, of the Asbestos Safety Control Act. So possibility of asbestos exposure is not yet a major concern at current levels for sites demolished of asbestos containing buildings in Seoul. Looking at each sampling point, the average airborne asbestos concentrations in boundary line of site, entrance of sanitation, around the workplace (in), around the workplace (out), negative pressure units, storage area for waste, outlet for waste and residential area of residents were respectively $0.002{\pm}0.002f/cc$, $0.004{\pm}0.002f/cc$, $0.004{\pm}0.002f/cc$, $0.004{\pm}0.002f/cc$, $0.004{\pm}0.002f/cc$, $0.005{\pm}0.004f/cc$, $0.005{\pm}0.003f/cc$ and $0.003{\pm}0.002f/cc$. As a result, all sampling points of study were satisfied with allowable exhaust standard for asbestos, 0.01 f/cc, of the Asbestos Safety Control Act.

A Study on Characteristics of Airborne Asbestos Concentrations Using PCM and TEM in Life Environment Surroundings of Seoul (서울지역 생활환경주변의 공기 중 석면분포 특성에 관한 연구)

  • Lee, Jinhyo;Lee, Suhyun;Kim, Jihui;Oh, Seokryul;Shin, Jinho;Eom, Seokwon;Chae, Youngzoo;Lee, Jinsook;Koo, Jayong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.9
    • /
    • pp.613-623
    • /
    • 2013
  • This study is purposed to evaluate the airborne asbestos concentrations in life environment surroundings in Seoul. In study, we investigated airborne asbestos concentrations in thirteen subway stations, four monitoring networks and each vicinity roadside, six stream surroundings, four tunnels quarterly and we also investigated relationship between the airborne asbestos concentrations and ambient temperature in monitoring networks and time-based airborne asbestos concentration variability for two typical monitoring networks, two subway stations transferred and used by lots of people through Phase Contrast Microscopy (PCM) and Transmission Electron Microscopy (TEM). The airborne asbestos concentrations by PCM for 4 objects of study were less than the detection limit (7 fiber/$mm^2$) in 111 (50%) out of 223 samples. The highest concentration was 0.0130 f/cc. But additional TEM analysis result for samples exceeding the guideline value for indoor air quality (0.01 f/cc) proposed by the Ministry of Environment (Korea), no asbestos was detected. Similarly TEM analysis result for 124 samples, no asbestos was detected. The average airborne asbestos concentrations by PCM in subway stations, monitoring networks, streams and tunnels were $0.0041{\pm}0.0027$ f/cc, $0.0015{\pm}0.0011$ f/cc, $0.0024{\pm}0.0012$ f/cc and $0.0016{\pm}0.0020$ f/cc. All objects of study were satisfied with the guideline value for indoor air quality. The relationship between the airborne asbestos concentrations and ambient temperature in monitoring networks was generally positive correlation (r = 0.660). The higher ambient temperature was and the more transient population was, the airborne asbestos concentrations by time for two subway stations were increased. While the airborne asbestos concentrations for two monitoring networks showed no variation pattern according to time.

Characteristics of Indoor air concentration of asbestos in buildings (건물의 실내공기 중 석면 분포 특성)

  • 김윤신;이철민;박원석;문정숙;엽무종;이태형
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.05b
    • /
    • pp.427-428
    • /
    • 2003
  • 현대인의 경우 대부분이 하루 중 80% 이상의 시간을 어떤 형태의 가정, 사무실, 공공건물, 학교, 병원, 지하시설물, 상가, 음식점, 자동차, 지하철 등의 실내공간에서 생활하고 있으며, 특히 어린이와 노약자, 병약자들의 경우 대부분의 시간을 실내에서 보내고 있는 실정에 있어 실내공기오염이 인체에 미치는 영향은 크다고 할 수 있다. 실내환경에는 대기환경과는 달리 물리적, 화학적, 생물학적으로 매우 다양한 오염물질들은 복합적인 배출원에서 기인되며 그 배출량은 물질에 따라 상당히 편차가 있을 뿐 아니라 오염물질 농도분포 역시 시간적, 공간적 특성에 따라 다양하게 나타날 수 있으며, 실내공기의 상태는 일차적으로 외부공기의 영향을 받게 되고 이차적으로는 담배연기, 스토브, 오븐, 시멘트, 건축자재, 페인트 및 벽면의 입자상 물질 등과 같은 실내오염원으로부터 영향을 받아 오염상태가 심해진다. (중략)

  • PDF

Preparation and assessment of airborne fibrous reference sample for a proficiency test (국내 공기 중 섬유상 분진 숙련도 시험용 표준시료 제조 및 평가)

  • Lim, Hoju;Ryu, Jaihyuk;Choi, Sungho;Choi, Arum;Jung, Hyunsung;Ryu, Jungmin;Kim, Hyunwook;Jang, Seongki
    • Analytical Science and Technology
    • /
    • v.22 no.5
    • /
    • pp.369-375
    • /
    • 2009
  • We evaluated the homogeneity and accuracy of low level airborne fibrous standard, and accomplished the proper proficiency test. We had found that the correlation of concentration of standard solution and asbestos density was 0.9863~0.9968, and concluded that the proper guideline of the analysis result was ${\mid}Z{\mid}{\leq}2$ interval of Z-score.

A Study on the Measurement and Investigation of Air Quality in a University Library (대학도서관 실내 공기질 측정 및 조사 연구)

  • Lee, Jae-Won
    • Journal of Korean Library and Information Science Society
    • /
    • v.50 no.4
    • /
    • pp.635-658
    • /
    • 2019
  • In this study, the harmful factors measured in S university's central library were divided into ① air harmful substance ② biological harmful factors ③ carbon monoxide, carbon dioxide, and nitrogen dioxide concentration, measured and analyzed compared to the relevant criteria. The analysis showed that the harmful substances in the air - fine dust, asbestos, volatile organic compounds and formaldehyde - were all lower than the relevant standards, and that biological harmful factors such as fungi in the air, gramophageal bacteria, and endotoxin were also found to have no particular problems. The concentration of carbon monoxide, carbon dioxide, and nitrogen dioxide in the air was also maintained without any unusual factors compared to the concentration in the ordinary atmosphere. However, the library is a multi-use facility that needs regular cleaning and ventilation to manage the environment.

Characteristics of indoor air quality in the overground and underground railway stations (지상과 지하역사의 실내공기질 특성과 외기영향 평가)

  • Namgung, Hyeong-Kyu;Song, Ji-Han;Kim, Soo-Yeon;Kim, Hee-Man;Kwon, Soon-Bark
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.17-25
    • /
    • 2016
  • In this study, the air quality of underground and overground railway stations was evaluated focusing on the degree of influence of the outside air quality. The measured components were particulate matter ($PM_{10}$), carbon dioxide ($CO_2$), carbon monoxide (CO), nitrogen dioxide ($NO_2$), formaldehyde (HCHO), ozone ($O_3$), total airborne bacteria (TAB), total volatile organic carbon (TVOC), and Radon (Rn), which are included in the maintenance standards and recommended standards of the Indoor Air Quality Management Act. Also, the indoor/outdoor concentration ratios of $PM_{10}$, $NO_2$, and $O_3$ were calculated to estimate the influence of the outdoor air quality. The concentrations of $PM_{10}$ HCHO, TVOC, $NO_2$, and Rn in the underground stations were found to be higher than those in the overground stations. These results indicate that the (present) generation of contaminants are caused by the indoor source of the underground station. The ozone concentration of the overground stations was higher than that of the underground stations, which indicates that the outdoor ozone concentration influenced that of the overground stations directly. Thus, methods of improving the IAQ should take into consideration the types of contamination.