• Title/Summary/Keyword: 실내마감재

Search Result 84, Processing Time 0.02 seconds

Unsteady Analysis of Indoor Radon in Apartment Buildings Considering Finishing Materials and Ventilation (마감재 및 환기를 고려한 공동주택 실내 라돈 농도의 비정상 해석)

  • Cho, Hyun;Pang, Seung-Ki
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.15 no.4
    • /
    • pp.24-31
    • /
    • 2019
  • In this paper, we simulated a new apartment building by using radon emission test values from various building materials used as interior finishing materials. The simulations evaluated the radon concentration in the room according to the radon emissions and the ventilations for each type of finishing material (gypsum board, stone, tile and concrete). Overall concrete finish simulation case showed the highest concentration than the case using other materials due to the effect of wall area at the center of each room and the mean radon concentration at 1.5 m above the floor was slightly lower than the mean value at each center. In the case of the porch, pantry and bathroom, the radon concentration was high even when the same materials were used as in the other rooms.

Interior Cost Estimating as a Design Marketing Tool - for Executive Office Interior (디자인 마케팅을 위한 인테리어 공사비 초기 예측기법- 일원공간의 인테리어 프로젝트를 중심으로 -)

  • 이혜연
    • Korean Institute of Interior Design Journal
    • /
    • no.23
    • /
    • pp.68-73
    • /
    • 2000
  • The purpose of this research is to develop interior construction cost-estimating system at the early stage of the project. Though general construction estimates are typically in quantitative, interior construction should be in rather qualitative. Therefore, design-concerned cost-estimating methods should be developed to manage interior projects from the early statge. 30 estimates of VIP-Zone interior projects, were examined to develop the general type of composition and material classification. The cost has been classified by construction parts such as wall, ceiling, floor, and doors & windows and their treatments. The composition and material related estimating system (CMRES) was consisted of the unit average costs of classification and the variation coefficients. The CMRESS was verified by the case study, and the results sowed that the difference between the actual estimate and the CMRES was competitively confident.

  • PDF

A Study on a Database Management System for Health-friendly Building Materials (건강친화형 건축자재의 DB화 연구 - 실내마감재를 중심으로 -)

  • Kwon, Gi-Deoc;Lee, Dong-Hoon;Kim, Sun-Kuk
    • KIEAE Journal
    • /
    • v.9 no.6
    • /
    • pp.3-11
    • /
    • 2009
  • Building materials have a great impact on the health of a building's occupants. Thus, it is imperative that their health-related properties be taken into during the course of construction project. Unfortunately, no current database system exists that can provide information on the health performance of building materials at each stage of construction project management, from planning and design to building and maintenance. therefore, an inordinate amount of time and effort is required to choose the right health-friendly materials(DBHM). To solve this problem, this study aims at building a database management system for health-friendly building materials. It analyzes the health-related properties and performance of various materials, and proposes a database structure and operation algorithm. The system proposed in this study is expected to contribute to the objective evaluation of health-friendly building materials through the accumulation of relevant data.

Emission rates of VOCs/VVOCs from multi-layers and their impacts on indoor air quality of Apartments (마감공사후 경과시간에 따른 복합마감재의 VOCs/VVOCs 방출량과 실내농도에 관한 연구)

  • Yoon, Chang-Hyun;Kwon, Kyung-Woo;Park, Jun-Seok
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.295-300
    • /
    • 2006
  • The purpose of this study is to evaluate the impacts of finishing materials' VVOCs and VOCs emission rates on indoor air quality of Apartment. VOCs emission rate of multi-layer finishing is predicted using the effective diffusion coefficient of each materials, and then the prediction is compared with Mock-up test and sample apartment house. From the results, the prediction of multi-layer finishing using the effective diffusion coefficient show good relation with the measured values.

  • PDF

Comparison of Acoustic Performance Depending on the Location of Sound Absorptive and Diffuser in Small Auditoriums Using 1/10 Scale Models (1/10 축소모형을 이용한 소공연장의 흡음재와 확산체의 적용위치에 따른 음향성능 비교)

  • Kim, Tae-Hee;Park, Chan-Jae;Park, Ji-Hoon;Haan, Chan-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.34 no.2
    • /
    • pp.146-156
    • /
    • 2015
  • This study investigated how the location of sound absorptive materials and sound diffusers affects the acoustic performance of small auditoriums. It was conducted for a standard model established with the averaged dimension of 36 auditoriums which had opened since 2000 in Daehak-ro, Seoul. In this study, the installation area of finishing materials was calculated upon a back wall which had the smallest installation effective area of finishing materials. To analyze the changes of acoustic performance according to installation location of finishing materials, experiments were carried out using the 1/10 down scale models for 8 cases which were made by classifying the installation location of ceiling and side wall into the front, middle and rear part.The used acoustic parameters were reverberation time (RT), early decay time (EDT), clarity (C80), definition (D50) and speech transmission index (STI). In result, the index related to the amount of reverberant sound (RT, EDT) showed the great changes when evaluating it through just noticeable difference (JND), but the one related to clarity (C80, D50, STI) hardly indicated the changes. In case to obtain short reverberation time, it was most effective to control reverberation time through the side walls when installing sound absorptive and diffusive materials, and side wall front was the location which could get the shortest reverberation time.

Evaluation of Decreasing Concentration of Radon Gas for Indoor Air Quality with Magnesium Oxide Board using Anthracite (안트라사이트를 활용한 산화마그네슘 보드의 실내 공기질 중 라돈가스 농도 저감 평가)

  • Pyeon, Su-Jeong;Lim, Hyun-Ung;Lee, Sang-Soo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.18 no.1
    • /
    • pp.9-15
    • /
    • 2018
  • Radon gas, which is present on the earth, is a primary carcinogen released from rocks, soil, building materials, etc., and exists as a unique gas phase. In order to solve the risk of radon gas, we evaluated the basic performance which can be used as indoor finishing materials in addition to the radon gas reduction properties of the matrix using anthracite. An anthracite used as a conventional filter material was used to produce a matrix, and a test was conducted to replace the gypsum board, which is one of the building materials used in the existing room. As the anthracite replacement ratio increases, flexural failure load strength increases and thermal conductivity tends to decrease. Depending on the thickness of the board, the reduction performance of radon gas shows a slight difference.

Noise and Rooms Acoustic Control in Multi-Purpose Space (다목적 공간의 소음 및 실내음향 제어)

  • Jeong, Jeong-Ho;Kim, Jung-Joong;Cho, Chang-Geun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.42-45
    • /
    • 2008
  • 다목적 공간 및 공연장은 공연 또는 강연을 위한 공간뿐만 아니라 상점, 식당 및 체육 공간 등 다양한 용도의 공간이 인접되고 있다. 다양한 공간이 인접할 경우 기존의 다목적 공연장에서는 발생하지 않았던 다양한 소음 진동 문제들이 발생한다. 본 연구는 강연 및 공연을 위한 다목적 공간 상부에 식당 및 체육 시설로 활용되는 공간이 배치되어 바닥충격음 문제가 발생할 가능성이 있었다. 바닥충격음의 강당으로의 전달을 차단하기 위하여 기본 구조체에 대한 바닥충격음 차단성능을 측정하여 적절한 저감 대책을 수립하였다. 저감대책으로는 상층부 철골 슬래브와 강당의 철골 구조의 구조적 분리, 유연한 마감재 적용, 슬래브로의 충격진동 차단을 위한 제진재 적용, 이중천장 구조 및 천장내부 흡음구조 형성 등의 종합적인 대책을 수립하였다. 이를 통해 경량충격음 및 중량충격음을 효율적으로 차단하였다. 또한 강당 공간은 강연 및 집회의 공간으로 활용될 수 있도록 하기 위하여 적절한 잔향시간 및 음성 명료도 확보가 필요하다. 플러터 에코, 과도한 잔향시간, 음의 사각지대 등을 최소화하기 위하여 측벽 형태 개선, 천장 반사판 형태를 개선하였다. 또한 측벽에서 진동 등의 영향으로 발생되는 떨림현상을 억제하기 위하여 측벽 내부를 흡음재로 충전하는 등의 대책을 수립하여 적용하였다.

  • PDF

Characteristics of VOCs Emission According Interior Finish Materials and Working Phases of New Apartments (신축 아파트의 실내 마감재 변경 및 시공단계별 휘발성유기화합물 발생 특성)

  • Pang, Seung-Ki;Cho, Woo-Jin;Sohn, Jang-Yeul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.6
    • /
    • pp.486-492
    • /
    • 2006
  • In this research, IAQ is measured to evaluate the emission performance of VOCs in three new apartment houses finished by totally EFMs (Environmental Friendly Material), partially installed EFMs and general materials. Among various VOCs, Target pollutants for the IAQ measurement are benzene, ethylbenzene, toluene, xylene, 1,4-Dichlorobenzene and formaldehyde. The measurement is conducted one day after each interior finishing material is worked over by construction schedule. The result of this research concluded that (1) Except toluene, the concentration levels of each pollutant did not exceed the national IAQ standards in all test residences, (2) As the interior finishing work schedule, A toluene level peaked when the furniture installing was ended. (3) The toluene concentration level of the house installed general interior materials as the non-EFMs furniture was one and half higher than other houses. Consequently, installing. the furniture made by EFMs is one of effective methods to improve the IAQ for new apartment houses.

The Effect on the Granodiorite Suspension Coated Indoor Finishing Materials for Reduction of TVOC Emissions (실내 마감재료의 TVOC 방출 저감을 위한 화강섬록암 현탁액 도포효과)

  • Lee, Jong-Gyu;Kim, Ji-Hyun;Lee, Jae-Yong;Lee, Soo-Yong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.8 no.5
    • /
    • pp.93-99
    • /
    • 2008
  • The environment draws attention in the global community and a growing number of Koreans have interest in improving the quality of life, the importance of house environment has attracted the attention of the public. Against this backdrop, constructors have unveiled environmentally -friendly projects. However, they failed to establish people-oriented environment by being occupied with maximizing profitability through the improvement of brand image and caused sick house syndrome that has recently made controversy. In this regard, the study analyzed the mechanism of discharge of TVOC, one of the sick house syndrome-causing materials, that affects IAQ and its characteristics and examined the effect that granodiorite has on reduction of the discharge of TVOC in order to minimize damage. Experimental sample consisted of interior finishing materials frequently used in ceiling, wall and floor and adhesives used at a time of construction, and the TVOC of building materials was measured through the use of septum bottle unlike In the existing chamber method. Measures to counter the sick house syndrome were suggested by reducing the possible damage from the stage of selection of building material and by figuring out the effect that the granodiorite has on reduction of the discharge of TVOC.

Indoor Visual Environmental Estimate Experiment Evaluation of See Through BIPV Curtainwall System (가시성확보 BIPV 커튼월시스템의 실내 시환경 예측 시험 평가)

  • Cha, Kwangseok;Jo, Boram
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.108-108
    • /
    • 2011
  • 공동주택에서 2025년 정부가 추진하고 있는 Zero Energy 건축물 구현과 친환경에 대한 탄소배출 저감 문제로 재생에너지 생산시스템의 추가 적용은 반드시 필요하다. 따라서 공동주택 적용 및 활용성을 높일 수 있는 BIPV시스템 개발을 통하여 설치면적 확보와 세대 활용성을 높일 수 있도록 하는 것이 필요하다. 특히 거실 창호의 경우 주방향이 남향, 남동 또는 남서향으로 배치되어 태양광을 적용하기에 적합한 특성을 가지고 있다. 그러나 창호는 건물외피의 역할과 재실자가 조망과 정보취득을 얻을 수 있는 중요한 통로가 되기 때문에 단열 문제나 시야 차폐의 문제는 발생하지는 않도록 하는 것이 필요하다. 본 연구에서는 a-si타입 모듈 2개를 10% 투과율로 Bsck Coating 색상을 달리한 모듈과 c-si BIPV 모듈을 커튼월 창호시스템으로 개발, 일반 2중 창호시스템과 비교 평가를 위해 실제 Test bed 건물에 시공하여 시환경 및 실내 창측면 온도변화 측정 분석을 진행하였다. 현재 국내외 출시되고 있는 a-si see through 모듈은 10~30%의 투과율로 창 마감재로 대체가 가능하나 건축 환경(시환경,열환경)에 대한 분석은 전무한 상태이다. 본 연구에서는 시환경과 창유리면의 열 부하, 자외선, 적외선 차폐 및 가시광선의 투과율에 대한 평가와 Back Coating에 따른 색온도 평가를 통해서 a-si BIPV의 공동주택 세대 발코니 창호 적합성에 대한 검토를 진행하였다. 연구결과는 아래와 같다. ${\bullet}$ 실내조도는 청천공 정오기준 가시성 확보 모듈의 경우 2,300 ~ 3,500lx를 나타내고 있어 대비 현상이나 창측의 급격한 조도 변화가 적은 시환경 구축이 가능 ${\bullet}$ 12시경 휘도는 창측면, 실내 벽체, 코너 바닥면을 대상으로 a-si BIPV 모듈을 적용한 경우 휘도비가 12:1로 KS나 IESNA의 광원과 근접면의 비 20:1 범위에 모두 존재, 적합한 것으로 분석되었으나 c-si의 경우는 그림자로 인한 대비 현상이 발생, 작업 시환경 문제 발생. ${\bullet}$ 이중시스템 창호와 비교하여 단열 성능 떨어짐. 발전시간대 창유리 면 온도 상승 으로 하절기 냉방부하 증가. ${\bullet}$ 자외선은 100% 가까이 차단, 적외선은 13~42%만 투과되고 가시광선은 13% 투과율을 나타내어 일반 창에 칼라 코팅을 적용하는 것과 유사한 경향을 나타냄.

  • PDF