• Title/Summary/Keyword: 실내공기 질

Search Result 241, Processing Time 0.03 seconds

A Numerical Study of the Air Quality Inside Automobiles According to the HVAC System Operating Conditions (HVAC 작동특성에 따른 자동차 실내 공기질 평가에 관한 수치해석적 연구)

  • Yoon, Seonghyun;Seo, Jinwon;Choi, Yunho
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.23 no.3
    • /
    • pp.299-309
    • /
    • 2014
  • When using an automotive heating, ventilation, and air conditioning (HVAC) system, we can obtain fresh outside air while maintaining the interior vehicle temperature. In this study, a correction equation considering experimental data for automotive indoor air leakage is defined to simulate the ratio of fresh air to recirculated air in the automobile cabin. With this correction equation, numerical results are compared with experimental data and validated. The $CO_2$ concentration in the automotive cabin is evaluated by considering various boarding conditions and mass flow rates of the HVAC system. The $CO_2$ concentration model derived in this study is expected to be used to control the effective air conditioning and become a basic research tool for automotive air quality control system development.

Indoor Environment and Characteristics and Satisfaction of Users of Senior Centers in Wanju County (완주군 경로당의 실내환경과 이용자들의 특성 및 만족도)

  • Jeong, In-Soo;Meng, Xiangwei
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.19 no.1
    • /
    • pp.23-34
    • /
    • 2017
  • The purpose of this paper is to suggest the preliminary data for the improvement of the senior centers' indoor environment and the upcoming progress located in rural areas. In wanju county, 81.8% of seniors were enrolled in senior centers, and used the facility everyday. Also, most of the users tended to use the facilities between 12 a.m. and 6 p.m. The majority of users had lunch at the senior centers. The facilities of most senior centers were in poor condition, and some had their restroom outdoor. Also, most senior centers are exposed to high concentrations of carbon dioxide during winter. During this season, the thermal environment in the restroom was bad. However, the users' level of the facilities' satisfaction was positive. Senior centers have been operating the facilities with difficulties, due to the low financial support from the local autonomous organization. The indoor temperature in most centers, especially, was above $30^{\circ}C$ during summer on account of lack of funding for airconditioning. Therefore, it could be recommended that the local autonomous entity start regular check-ups and repairs for the poor indoor environment and facilities, with more financial support and active supervision of the management.

A Numerical Analysis of the Abatement of VOC with Photocatalytic Reaction in a Flow Reactor (연속흐름 반응기에서 광촉매 반응에 의한 VOC 물질제거 특성에 대한 수치적 연구)

  • 최우혁;김창녕;정석진
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.7
    • /
    • pp.637-646
    • /
    • 2001
  • VOC(Volatile Organic Compound) removal characteristics in continuous flow reactors have been numerically investigated. The photocatalytic reaction have been simulated with the binding constant and the reaction rate constant obtained from experimental data for the constant-volume batch reactor, and then VOC abatement in continuous flow reactors with the same conditions as those of batch reactor has been analyzed. The standard 4\kappa-\varepsilon$ model and mass conservation equation have been employed for numerical calculation, and heterogeneous reaction rate has been used in terms of the boundary condition of the conservation equation. in the case of the continuous flow reactor, reaction characteristics have been estimated with various inlet velocities and with different number of baffles. The result shows that the concentration distribution and flow patterns are strongly affected by the inlet velocity, and that with the increased inlet velocity, VOC removal rate is increased, while removal efficiency is decreased. This result may be useful in the design of reactors with improved VOC removal efficiency.

  • PDF

Effects of Flush-out in the Reduction of Formaldehyde in Newly Built Residential Buildings (신축 공동주택에서 플러쉬아웃에 따른 폼알데하이드 농도 저감 효과에 관한 연구)

  • Park, Sang In;Kim, Joo Han;Park, J.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.30 no.3
    • /
    • pp.116-122
    • /
    • 2018
  • The purpose of this study was to confirm the effects of flush-out in the reduction of formaldehyde concentration in newly built residential buildings. The field measurements were conducted on two complexes of multi-residential buildings which are located in the suburban area of Seoul. About eight samples of residential buildings were selected to measure the changes in formaldehyde concentrations after flush-out from the two apartment complexes. The concentration of formaldehyde was measured using DNPH cartridge and HPLC. From the results of the field measurements, it was established that indoor formaldehyde concentration decreases 27.6~54.2% in the samples after flush-out. The number of days that the flush-out were conducted was noted to have no significant influence on the reduction rate of formaldehyde concentration when the flush-out continued more than 7 days. The comparison with Bake-out showed that flush-out also can reduce formaldehyde in newly built buildings as same levels of it.

A Cost Analysis of the Heat Recovery Ventilator under Various Condition (열회수형 환기장치의 운전조건에 따른 경제성 평가에 관한 연구)

  • Kang, Tae-Wook;Koh, Jae-Yoon
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.1
    • /
    • pp.21-28
    • /
    • 2006
  • Changes in building construction methods and repairing of older buildings have reduced infiltration rate. Synthetic materials, release airborne particles and uneven healthy odor are increased. For preventing pollutants introduce fresh outdoor air into the building, simply letting fresh outdoor air into building, however, Is not a cost-effective way to ventilation. When additional ventilation is added to an existing HVAC system, the heating and cooling equipment, often cannot handle the increased load. A HRV provides a way to minimize in energy costs while introducing fresh air to a building. In this study, the economical research of HRV, made of three types of materials, are conducted. Heat recovering characteristics are studied at seasonal outdoor air conditions based on the outdoor air property condition at, Seoul in 2002. As a results, the average sensible effectiveness is 0.75 in the sensible heat exchanger and average total effectiveness is 0.65 in the total heat exchanger. The pay back period of the sensible heat exchangers are $3.2{\sim}3.5$ year and it of total heat exchanger is 2.2 years.

Study on operation characteristics of the cold air distribution systems with an ice storage tank (빙축열을 이용한 저온공조시스템 운전 특성 연구)

  • 염한길;박병규;고득용
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.3
    • /
    • pp.301-312
    • /
    • 1999
  • Experiments were carried out to evaluate performance of the cold air distribution systems with an ice storage tank in test room. Cold air distribution systems provide primary air for comfort conditioning or process cooling at coil discharge temperatures$4^{\circ}C$ to$11^{\circ}C$. The application of a cold air distribution system allows for the downsizing of air distribution equipment and central plant equipment when ice storage tank is used. The benefit of a cold air distribution system include a decrease in the floor-to-floor height, increase floor space, reduced building capital costs, reduced energy use and demand. The use of cold air distribution can result in the most cost effective system and is currently being implemented world wise as the new standard in air conditioning systems. In this study, the cold air distribution system is compared with the general ice storage system. Under the same cooling load conditions, experimental results show that the supply air volume of cold air distribution system decrease 38%, and decrease 45% flow rate of brine for the general ice storage system.

  • PDF

Evaluation of Comfortableness in Railroad Electric Rolling Stock - Focused on Temperature and Humidity - (철도 전동차내의 쾌적성 평가에 관한 연구 - 온도 및 습도를 중심으로 -)

  • 박덕신;배상호;정병철;이주열
    • Journal of the Korean Society for Railway
    • /
    • v.6 no.1
    • /
    • pp.41-48
    • /
    • 2003
  • Most of people spends their times in indoor about 85% of a day. Thus, indoor is more serious than outdoor concerned with the health. We discussed comfortableness in a railroad electric rolling stock, and focused on temperature and humidity. Electric rolling stock is one of major public transportation system because of an increasing in population and heavy traffic problems. The passengers are under the influence of indoor air quality such as air temperature, relative humidity and air velocity. Ventilation system in electric rolling stock should be designed for the health and comfort. One of the main aims is to create an acceptable thermal environment without draught problem. The draught sensation increases when the air temperature decreases and the air velocity increases. Airflow in electric rolling stork is turbulent. Temperature and humidity gradients in electric rolling stock have been studied. And, the difference between mean temperature and rotative humidity measured at 0.7, 0.9, 1.2, 1.7m above the floor. It has been found that temperature and relative humidity with large fluctuations caused more draught complaints.

Radon Adsorption Characteristics of Blast Furnace Slag Matrix Using Bamboo Activated Carbon (대나무 활성탄을 활용한 고로슬래그 경화체의 라돈흡착 특성)

  • Park, Chae-Wool;Lee, Jae-Hun;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.27-28
    • /
    • 2019
  • Recently, a bed company detected a radon more than Red Politics and became a hot topic of conversation. This has led to increased interest in radon, and a number of free-of-charge bodies have also been established to recognize the dangers of radon. In addition, the Korean Institute of Geological and Resource Research is planning to assist the installation of radon alarm systems in 10,000 households nationwide, free of charge. Since radon is a colorless, odorless and tasteless gas that causes lung cancer, it aims to reduce lung cancer incidence by absorbing radon using bamboo activated carbon as a way to reduce it. Due to the use of bamboo activated carbon, radon concentration per hour tends to decrease as substitution rate increases, and table flow tends to decrease as substitution rate increases. Through this experiment, 30% of the replacement rate of bamboo activated carbon is judged to be the most suitable replacement rate.

  • PDF

Using multi-sensor for Development of Multiple Occupants' Activities Classification Model Based on LSTM (다중센서를 활용한 LSTM 기반 재실자 행동 분류 모델 개발)

  • Jin Su Park;Chul Seung Yang;Kyung-Ho Kim
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.6
    • /
    • pp.1065-1071
    • /
    • 2023
  • In this paper discuss with research developing an LSTM model for classifying the behavior of occupants within a residence. The multi-sensor consists of an IAQ (Indoor Air Quality) sensor that measures indoor air quality, a UWB radar that tracks occupancy detection and location, and a Piezo sensor to measure occupants' biometric information, and collects occupant behavior data such as going out, staying, cooking, cleaning, exercise, and sleep by constructed an experimental environment similar to the actual residential environment. After the data with removed outliers and missing, the LSTM model is used to calculate accuracy, sensitivity, specificity of the occupant behavior classification model, T1 score.

Indoor air quality analysis based on genetic algorithm for childhood facilities (유전 알고리즘을 이용한 어린이 시설의 실내 공기질 분석)

  • Seo Yeon Park;Chang Gyu Woo
    • Particle and aerosol research
    • /
    • v.20 no.1
    • /
    • pp.1-11
    • /
    • 2024
  • Children are vulnerable to bad indoor air quality, and many researches on indoor air quality have been done with various methodologies. Herein, we used the genetic algorithm, one of the optimization methods, for the analysis based on better estimation values that are not easy to measure. A children playroom and a Taekwondo gym were chosen for the different degree of physical activity. After estimation of the number of occupants, the generation degree of CO2 and PM2.5 were determined from the data of the indoor air quality monitors. Relative errors were below 1% for all cases. Due to many air-treating electronics, the PM2.5 in the children playroom was well-managed compared to that in the Taekwondo gym. The PM2.5-generating activities were calculated and that of the Taekwondo gym was higher than that of the children playroom. The PM2.5 generating values were on the positive relationship with CO2 generating values. This means that we can obtain meaningful information from limited measurement data. For the numerous children facilities, indoor air quality can be easily analyzed and this might contribute to enhancing the children health.