• Title/Summary/Keyword: 실내공기유동

Search Result 77, Processing Time 0.036 seconds

Survey of ICT Apply to Plastic Greenhouse, Rack·Pinion Adaption to Single Span and CFD Analysis (온실 ICT융복합 실태조사와 복숭아형 랙피니언천창 적용 단동온실 및 CFD 유동해석)

  • Cho, Kyu Jeong;Kim, Ki Young;Yang, Won Mo
    • Journal of Bio-Environment Control
    • /
    • v.24 no.4
    • /
    • pp.308-316
    • /
    • 2015
  • This study was conducted to investigate the situation of ICT apply to plastic greenhouse, and the results be apply to design of new one. A CFD analysis were conducted to monitering the ventilation and energy saving of the single span greenhouse newly designed. The causes of delay to apply ICT to plastic greenhouse are the high cost for installation(24%), insufficiency of after services(19%), often disorder(16%), unskillful management of soft ware(15%), insufficient ICT efficiency(13%) and unsatisfying of income increase(12%). The parts of problem occurred in ICT plastic greenhouse are the structure, actuator, environmental control system and sensor(approximate 14%, respectively), remote control technique(13%), plant management technique(12%), energy saving technique(10%) and utilization of software(8%). In the condition of lateral window closed, the average wind speed changed to slow, but it was faster in the condition of leeward side window opened than in the condition of lee and winward side window opened. The air movement in the condition of lateral window closed occur by air moving fan not by out air. It is not affect the room temperature but effective the uniformity of room temperature. The average temperature of low height greenhouse was uniform than high height one. The average temperature in condition of 3rd curtain opened become same with outside temperature after 2 hours, but take more 5 hours in condition of 3rd curtain closed.

Estimation of Indoor Environment using CFD of Multi-Purpose System with a Solar Collector -Part 1, focused on floor area and number of ventilation- (태양열온수기 적용 냉난방시스템의 CFD를 이용한 실내환경 평가 -제1보 바닥면적과 환기횟수를 중심으로-)

  • Kim, Jong-Ryeol;Choi, Kyang-Hyan
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.3
    • /
    • pp.55-61
    • /
    • 2007
  • This paper has been conducted to estimate cooling capacity of the dehumidification tower using hot water from a solar water heating system as a energy source of regeneration process when the dehumidification and drying system is applied to room cooling. A solar water heating system was operated and indoor temperature distributions were simulated according to weather conditions when the concerned solution was used to dehumidify room air in the dehumidification tower. Through this simulation researches we found th following results ; It was found that air velocity through supply and return diffusers should be controlled because it can cause uncomfort in dwelling area. It was found that in the sunny morning temperatures of dwelling area 1 and 2 are higher than those of dwelling area 3 and 4. In this research all the calculation results of heating and cooling system supported by solar water heater have confirmed that its cooling capacity could not reach PMV 0, thermal comfort.

A Study on The Hydrodynamic Behaviours of Two Phase Flow in Rectangular Entrained Flow Combustor with Cavity (캐비티가 존재한 사각 단면 분류층 연소실내에서 2상류의 유체역학적 거동에 관한 연구)

  • 박상규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.21 no.1
    • /
    • pp.43-48
    • /
    • 1997
  • The present study is aimed to investigate experimentally on the hydrodynamic behaviours of air ~ pulverized coal flow in rectangular combustor with cavity. Mean velocity, density and tur¬bulent properties of pulverized coal in rectangular entrained flow combustor were measured by PDA. Experimental results show that the flow reattachment point at the lower plane in the com¬buster chamber has been developed near X/D= 15. The similarities at each section are found after the flow reattachment point. The maximum values of turbulent intensity and Reynolds shear stress have been shown near Y/D=6, which is higher than centerline. The maximum density of the pulverized coal sited in the range ofY/D=6~8.

  • PDF

A Numerical Analysis on the Indoor Air Ventilation by Stack Effect and Outdoor Wind in a High-rise Residential Building (초고층 주거건물에서 굴뚝효과와 외풍영향에 인한 실내 환기 기류해석 및 평가에 관한 연구)

  • Kim, Chi-Wan;Lim, Tae-Kun;Ahn, Young-Chull
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.12
    • /
    • pp.828-835
    • /
    • 2011
  • The purpose of this study is to analyze and evaluate the 3 types of indoor ventilation methods such as natural, mechanical, and hybrid ventilation in high-rise building which is affected by stack effect and outdoor air pressure. For the evaluation of the ventilation capacity, CFD simulation was performed in a typical high-rise residential building. The results of the simulations are as follows: 1) Natural ventilation method is not enough to the regulation. 2) In case of mechanical ventilation, congested area is occurred but meets the regulation. 3) In case of hybrid ventilation with stack effect, all the areas of indoor meet the regulation and congested area is reduced. 4) In case of high-rise building, the differences of ventilation rate among houses in the building are not large because the mechanical ventilation is main factor.

Analysis on Characteristics of Thermal Flow for Heating Indoor Space by Air-heating Collector using Solar Heat (태양열 공기가열 집열기에 의한 난방 실내공간의 열유동 특성 해석)

  • Yang, Young-Joon
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.2_2
    • /
    • pp.271-278
    • /
    • 2022
  • The solar energy has been widely used to reduce the fossil fuel and prevent the environmental pollution. The renewable energy including solar heat tends to spread due to carbon neutrality for main country of the world. Targets of solar collector are usually acquisitions of hot water or hot air. Especially, air-heating collector using solar heat is known as the technology for obtaining hot air. This study aims to investigate of characteristics of thermal flow when the hot air by air-heating collector using solar heat flows inside of indoor space. The thermal flow of heating indoor space was simulated using ANSYS-CFX program and thus the behaviors of hot air in indoor space were evaluated with standard k-𝜀 turbulence model. As the results, as the inlet velocity was increased, the behaviors of hot air became simple, and temperature range of 25~75℃ had almost no effect on behavior of flow. As the inlet temperature was increased, the temperature curve of indoor space from bottom to top was changed from linear to quadratic. Furthermore, it was confirmed that inlet velocity as well as inlet temperature also should be considered to heat indoor space equally by air-heating collector using solar heat.

Pressure Differentials in the Elevator Lobby Depending on the Evacuation Scenarios (피난 시나리오에 따른 승강장 부속실 차압 특성 연구)

  • Park, Yong-Hwan
    • Fire Science and Engineering
    • /
    • v.21 no.4
    • /
    • pp.38-43
    • /
    • 2007
  • The aim of this paper is to investigate the change of pressure differential and smoke propagation characteristics in the elevator lobby with the resident's evacuation scenarios using fire modelling technique. The results showed absolute pressures in the fire room and elevator lobby can significantly increase to cause fire door to the stairway unclosed once it is open. This is due to constant pressure differentials, the increasing reference pressure of fire lobby and pressure leak from elevator lobby to fire lobby. Smoke exhaust mechanism was needed to prevent the continuous pressure rise in the living room. Over 200 Pa was expected upon closing the door during pressurization, which provide difficulties in opening the door for next refugee. Opening both fire door and entrance door may induce smoke flow from fire room to elevator lobby and stairway.

Applications of a Coupled Multizone and CFD Simulation to Validate Airflow and Influenza A Contaminant Dispersion in Biosafety Laboratory (생물안전밀폐시설에서 Multizone과 CFD 연동해석에 의한 실내기류 및 Influenza A 오염농도해석)

  • Hwang, Ji Hyun;Hong, Jin Kwan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.588-593
    • /
    • 2014
  • To maintain a negative pressure, the supply, exhaust airvolume are adjusted by setting volume damper and the infiltration through leakage area of the door between rooms in biosafety laboratory. Multizone simulation is useful way to predict room pressure, supply and exhaust air volume. But in a particular room, local change such as airflow and contaminants concentration distribution can not be evaluated unfortunately. Through this study, a coupled multizone and CFD simulation was performed, indoor air flow and local contaminants concentration distribution in a particular room of BSL lab are predicted. The results show that all zones of BSL lab are well ventilated by unidirectional flow without local stagnation. In addition, in case that unexpected biohazard is occured in BSL lab, multizone simulation results about the spread of pollutants along movement of the occupant also show that contaminants concentration is removing totally without the spread of the outside. In conclusion, a coupled multizone and CFD simulation can be applied to interpret differential pressure in room and local change of physical quantity in a particular room such as airflow and Influenza A contaminants concentration distribution. This simulation method is useful to enhance the reliability and accuracy of biosafety laboratory design.

A Study on Characteristics of Airborne Asbestos Concentrations Using PCM and TEM in Life Environment Surroundings of Seoul (서울지역 생활환경주변의 공기 중 석면분포 특성에 관한 연구)

  • Lee, Jinhyo;Lee, Suhyun;Kim, Jihui;Oh, Seokryul;Shin, Jinho;Eom, Seokwon;Chae, Youngzoo;Lee, Jinsook;Koo, Jayong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.9
    • /
    • pp.613-623
    • /
    • 2013
  • This study is purposed to evaluate the airborne asbestos concentrations in life environment surroundings in Seoul. In study, we investigated airborne asbestos concentrations in thirteen subway stations, four monitoring networks and each vicinity roadside, six stream surroundings, four tunnels quarterly and we also investigated relationship between the airborne asbestos concentrations and ambient temperature in monitoring networks and time-based airborne asbestos concentration variability for two typical monitoring networks, two subway stations transferred and used by lots of people through Phase Contrast Microscopy (PCM) and Transmission Electron Microscopy (TEM). The airborne asbestos concentrations by PCM for 4 objects of study were less than the detection limit (7 fiber/$mm^2$) in 111 (50%) out of 223 samples. The highest concentration was 0.0130 f/cc. But additional TEM analysis result for samples exceeding the guideline value for indoor air quality (0.01 f/cc) proposed by the Ministry of Environment (Korea), no asbestos was detected. Similarly TEM analysis result for 124 samples, no asbestos was detected. The average airborne asbestos concentrations by PCM in subway stations, monitoring networks, streams and tunnels were $0.0041{\pm}0.0027$ f/cc, $0.0015{\pm}0.0011$ f/cc, $0.0024{\pm}0.0012$ f/cc and $0.0016{\pm}0.0020$ f/cc. All objects of study were satisfied with the guideline value for indoor air quality. The relationship between the airborne asbestos concentrations and ambient temperature in monitoring networks was generally positive correlation (r = 0.660). The higher ambient temperature was and the more transient population was, the airborne asbestos concentrations by time for two subway stations were increased. While the airborne asbestos concentrations for two monitoring networks showed no variation pattern according to time.

Performance Evaluation of a Portable GC for Real-time Monitoring of Volatile Organic Compounds (휘발성 유기화합물의 실시간 모니터링을 위한 휴대형 GC의 성능 평가)

  • You, Dong-Wook;Seon, Yeong-Sik;Oh, Jun-Sik;Yi, Bongyoon;Kim, Hyun Sik;Jung, Kwang-Woo
    • Journal of the Korean Chemical Society
    • /
    • v.64 no.6
    • /
    • pp.327-333
    • /
    • 2020
  • Performance of a portable GC that can be utilized for the real time determination of volatile organic compounds in air was evaluated. It employs purified/compressed ambient air as the carrier gas eliminating the need for high pressure gas tanks. The compact system with dimensions of 35 × 26 × 15 ㎤ and weight of 5 kg is powered by either a 24 V DC external adapter or battery pack. Chromatograms of the mixture sample including benzene, toluene, ethylbenzene, and oxylene at concentrations of 1 ppmv and 20 ppmv represent a good reproducibility: 3.79% and 0.48% relative standard deviations (RSDs) for peak area variations; 0.40% and 0.08% RSDs for retention times. The method detection limit was 0.09 ppmv. A 30 m long, 0.28 mm I.D. column operated at an optimal condition yielded a peak capacity of 61 with good resolution for a 10 min isothermal analysis. The relative standard deviations (RSD) of the peak area variations and retention times during consecutive measurements over 27 h were less than 2.4%RSD and 0.5%RSD, respectively. Thus, this instrument makes it suitable for continuous and field analysis of low-concentration VOC mixtures in the indoor/outdoor environment as well as the spillage accident of hazardous chemicals.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2010 (설비공학 분야의 최근 연구 동향 : 2010년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Lee, Dae-Young;Kim, Seo-Young;Choi, Jong-Min;Kim, Su-Min;Kwon, Young-Chul;Baik, Yong-Kyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.6
    • /
    • pp.449-469
    • /
    • 2011
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering during 2010. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends of thermal and fluid engineering have been surveyed as groups of general thermal and fluid flow, fluid machinery, and new and renewable energy. Various topics were presented in the field of general thermal and fluid flow. Research issues mainly focused on the thermal reliability of axial fan and compressor in the field of fluid machinery. Studies on the design of ground source heat pump systems and solar chemical reactors were executed in the field of new and renewable energy. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included heat transfer in thermoelectric cooling/power generation systems, combined heat and power systems, carbon nano fluid with PVP, channel filled with metal foam and smoke ventilation in a rescue station of a railroad tunnel. Also the studies on flow boiling of R123/oil mixture in a plain tube bundle and R410A charge amount in an air cooled mini-channel condenser were reported. In the area of industrial heat exchangers, researches on plate heat exchanger, shell and tube heat exchanger, enthalpy exchanger, micro channel PCHE were performed. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included heat transfer in thermoelectric cooling/power generation systems, combined heat and power systems, carbon nano fluid with PVP, channel filled with metal foam and smoke ventilation in a rescue station of a railroad tunnel. Also the studies on flow boiling of R123/oil mixture in a plain tube bundle and R410A charge amount in an air cooled mini-channel condenser were reported. In the area of industrial heat exchangers, researches on plate heat exchanger, shell and tube heat exchanger, enthalpy exchanger, micro channel PCHE were performed. (3) Refrigeration systems with alternative refrigerants such as hydrocarbons, mixed refrigerants, and CO2 were studied. Performance improvement of refrigeration systems are tried applying various ideas of refrigerant subcooling, dual evaporator with hot gas bypass control and feedforward control. The hybrid solar systems combining the solar collection devices with absorption chillers or compression heat pumps are simulated and studied experimentally as well to improve the understanding and the feasibility for actual applications. (4) Research trend in the field of mechanical building facilities has been found to be mainly focused on field applications rather than performance improvements. Various studies on heating and cooling systems, HVAC facilities, indoor air environments and energy resources were carried to improve the maintenance and management of building service equipments. In the field of heating and cooling systems, papers on a transformer cooling system, a combined heat and power, a slab thermal storage and a heat pump were reported. In the field of HVAC facilities, papers on a cooling load, an ondol and a drying were presented. Also, studies on HVAC systems using unutilized indoor air environments and energy resources such as air curtains, bioviolence, cleanrooms, ventilation, district heating, landfill gas were studied. (5) In the field of architectural environment and energy, studies of various purposes were conducted such as indoor environment, building energy, renewable energy and green building. In particular, renewable energy and building energy-related researches have mainly been studied reflecting the global interest. In addition, many researches which related the domestic green building certification of school building were performed to improve the indoor environment of school.