• Title/Summary/Keyword: 신호 잡음비

Search Result 1,923, Processing Time 0.03 seconds

Signal-to-noise Ratio in Time- and Frequency-domain Photoacoustic Measurements by Different Frequency Filtering (주파수 필터링 함수에 따른 시간 및 주파수 영역 광음향 측정에 대한 신호 대 잡음비 분석)

  • Kang, DongYel
    • Korean Journal of Optics and Photonics
    • /
    • v.30 no.2
    • /
    • pp.48-58
    • /
    • 2019
  • We investigate the signal-to-noise ratios (SNRs) of time-domain (i.e. pulsed illumination) and frequency-domain (i.e. chirped illumination) photoacoustic signals measured by a spherically focused ultrasound transducer for spherical absorbers. The simulation results show that the time-domain photoacoustic SNR is higher than that of frequency-domain photoacoustic signals, as reported in the previous literature. We understand the reason for this SNR gap between the two measurement modes by analyzing photoacoustic-signal spectra, considering the incident beam energy controlled by the maximum permissible exposure. As the result of this approach, we find that filtering off the DC term in the chirped signal's spectrum improves frequency-domain photoacoustic SNRs by up to approximately 5 dB. In particular, it is observed that photoacoustic SNRs are highly sensitive to an upper-frequency value of frequency filtering functions, and the optimal upper-frequency values maximizing the SNR are different in time- and frequency-domain photoacoustic measurements.

Study on Low Temperature Radiofrequencey Coils for the Signal-to-Noise Ratio Improvement of Nuclear Magnetic Resonance (핵자기공명 신호 향상을 위한 저온 고주파코일 연구)

  • Kim, Song-Hee;Lee, Dong-Hoon
    • The Journal of Natural Sciences
    • /
    • v.13 no.1
    • /
    • pp.15-23
    • /
    • 2003
  • 본 연구에서는 코일의 온도를 액체질소 온도 정도의 저온으로 냉각시켜 핵자기공명 신호 및 영상의 신호대잡음비를 향상시키는데 그 목적을 두었다. 핵자기공명 신호의 신호대잡음비에 대한 이론적인 분석을 토대로 다양한 형태의 고주파코일을 제작했고, 저온의 표면고주파코일로 획득된 신호를 상온의 일반 구리코일로 획득된 신호와 비교하였다. 본 연구에서 제작된 저온코일의 경우, 상온코일에 비해서 신호대잡음비의 향상을 얻을 수 있었다. 이러한 신호대잡음비의 향상을 통하여 핵자기공명영상 시간을 단축할 수 있으며, 이를 통한 진단의 신뢰도 향상에 기여할 수 있을 것으로 사료된다.

  • PDF

PN Code Acquisition at Low Signal-to-Noise Ratio Based on Seed Accumulating Sequential Estimation (시드 누적 순차적 추정 기법을 이용한 낮은 신호대잡음비 환경에서의 의사 잡음 부호 획득)

  • 윤석호;김선용
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.9A
    • /
    • pp.678-683
    • /
    • 2003
  • The pseudo-noise (PN) code acquisition based on the sequential estimation (SE) proposed by Ward performs well only at relatively high chip signal-to-noise ratios (SNRs). In this paper, a seed accumulating sequential estimation (SASE) method and a PN code acquisition system based on it are proposed, which perform well at low chip SNR (of practical interest) also. Then, the mean acquisition time performance of the proposed system is investigated. Numerical results show that the system based on the SASE performs dramatically better than that based on the SE at low chip SNR, and the improvement becomes larger as the period of PN code increases.

Performance Analysis of the Adaptive Coding System Based on Received SNR over a Rayleigh Fading Channel (레일레이 페이딩 채널에서 수신신호의 신호대잡음비에 근거한 적응부호화 시스템의 성능 분석)

  • 허성호;이재홍
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.7B
    • /
    • pp.1270-1281
    • /
    • 2000
  • 본 논문에서는 수신신호의신호대잡음비를 이용하여 작동되는 적응부호화 시스템을 레일레이 페이딩 채널 환경에서 분석한다. 분석에서는 레일레이 페이딩 채널을 수신신호의 신호대잡음비를 K개의 구간으로 나누어서 유한 상태 마르코프 채널로 모델링한다. 채널 상태를 예측하는 과정에서 발생하는 오류확률을 고려하여 적응부호화 시스템의 평균 BER과 throughput이 계산된다. 본 논문에서 제안한 분석 방법을 이용하여 천공 길쌈부호를 이용한는 적응부호화 시스템의 성능을 분석한 결과가 예제로 보여진다.

  • PDF

SNR and ADC Value Change before and after the injection of contrast medium during DWI test on metastatic spinal cancer patients (전이성 척추암 환자의 확산강조영상 검사 시 조영제 주입 전.후 ADC값의 변화에 대한 고찰)

  • Kim, Eng-Chan;Kim, Ki-Hong;Park, Cheol-Soo;Lee, Sun-Yeob;Yoo, Heung-Joon;Cho, Jae-Hwan;Jang, Hyun-Cheol;Kim, Bo-Hui;Han, Man-Seok
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.1
    • /
    • pp.37-49
    • /
    • 2011
  • To examine the possible changes in the SNRs, CNRs, and ADC values for lumbar spines with metastasis based on the DW images before and after contrast agent injection taken from metastatic spinal cancer patients using a 1.5 T MR machine. The quantitative analysis revealed that in case of spinal cancer subjects, both SNRs and CNRs at all of those assessed locations significantly increased on the DWI after contrast agent injection compared to before, while on the ADC map images, SNRs significantly decreased. On the other hand, significantly decreased ADC values at all the assessed locations were found on the ADC map images. With reference to the normal group, significantly increased SNRs were found at all of the assessed locations on the DWI image after injection compared to before, while significantly decreased SNRs were found on the ADC map images. Also, significantly decreased ADC values at all the assessed locations were found on the ADC map images. For the qualitative analysis, after contrast agent injection, significantly increased signal intensities were found at the locations with spinal cancer on the DWI. In contrast, significantly decreased signal intensities were found on the ADC map images. The implication from the results showing that SNR and CNR significantly increased while ADC value significantly decreased at, above, and below the location of metastatic spinal cancer on DWI after contrast agent injection is that DWI obtained after contrast agent injection can be made available for wider application to vertebral disorders.

Eye margin characteristics of 10Gb/s signals to the variation of optical signal to noise ratio and dispersion compensation (10 Gb/s 신호의 광학적 신호대 잡음비와 색분산 보상에 따른 아이 마진 특성)

  • 이상수;한정희;이동호;주무정;김민규
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.2
    • /
    • pp.169-173
    • /
    • 1999
  • We have experimentally investigated the eye margin characteristics of intensity modulated 10Gb/s NRZ signals in optically amplified systems depending on optical signal-to-noise ratio and chromatic dispersion. For the practical system application, the minimum optical signal-to-noise ratio was 25 dB. We utilized the negative chirped transmitter and a dispersion compensation fiber to compensate the chromatic dispersion in single mode fiber. We found the optimum eye opening and receiver sensitivity in case of the residual dispersion of 0~+935 ps/nm.

  • PDF

Flaw Detection of Ultrasonic NDT in Heat Treated Environment Using WLMS Adaptive Filter (열처리 환경에서 웨이브렛 적응 필터를 이용한 초음파 비파괴 검사의 결함 검출)

  • 임내묵;전창익;김성환
    • The Journal of the Acoustical Society of Korea
    • /
    • v.18 no.7
    • /
    • pp.45-55
    • /
    • 1999
  • In this paper, we used the WLMS(Wavelet domain Least Mean Square) adaptive filter based on the wavelet transform to cancel grain noise. Usually, grain noise occurs in changes of the crystalline structure of metals in high temperature environment. It makes the detection of flaw difficult. The WLMS adaptive filtering algorithm establishes the faster convergence rate by orthogonalizaing the input vector of adaptive filter as compared with that of LMS adaptive filtering algorithm in time domain. We implemented the WLMS adaptive filter by using the delayed version of the primary input vector as the reference input vector and then implemented the CA-CFAR(Cell Averaging- Constant False Alarm Rate) threshold estimator. CA-CFAR threshold estimator enables to detect the flaw and back echo signals automatically. Here, we used the output signals of adaptive filter as its input signal. To Cow the statistical characteristic of ultrasonic signals corrupted by grain noise, we performed run test. The results showed that ultrasonic signals are nonstationary signal, that is, signals whose statistical properties vary with time. The performance of each filter is appreciated by the signal-to-noise ratio. After LMS adaptive filtering in time domain, SNR improves to about 2-3㏈ but after WLMS adaptive filtering in wavelet domain, SNR improves to about 4-6㏈.

  • PDF

Assessment of Osteoporosis Based on Changes in SNR and ADC Values on MR Diffusion Weighted Images (확산강조영상에서 신호대 잡음비, 현성 확산 계수 변화에 따른 골다공증 평가)

  • Cho, Jae-Hwan;Kim, Yeong-Soo
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.70-77
    • /
    • 2010
  • This study tested how S/N (Signal to Noise Ratio) ratios and ADC (apparent diffusion coefficient) values vary with different T-scores in a group of patients with osteoporosis. Based on DEXA (Dual Energy X-ray Absorptiometry) T-scores for L1.L4 for two groups of subjects consisting of 30 healthy people without osteoporosis and 30 patients who came for treatment of waist (lumbar or low back) pain and were suspected to have osteoporosis as judged from the simple X-ray findings, this study classified every spine into two groups of osteoporosis and osteopenia. Signal intensity measurements were made in the four regions of L1 to L4 on diffusion-weighted MR images obtained using 1.5T MR scanner, while ADC measurements were obtained from ADC map images. As an approach for quantitative analysis, the comparison of the variances in S/N ratios and ADC values for varying T-scores in the selected regions of interest was carried out based on averaged T-scores, S/N ratios, and ADC values. Also, the variances in S/N ratios and ADC values for each of the groups of osteoporosis and osteopenia, which were classified into by T-scores, were compared. For qualitative analysis, a careful naked eye examination of signal intensity differences in the area of L4 was made on T1-weighted sagittal images for each of the healthy (normal), osteopenia, and osteoporosis groups. In the qualitative analysis, it was found that for both the osteopenia group and the osteoporosis group, as T-scores deceased, the S/N ratios on diffusion-weighted MR images also decreased, with the greatest decrease in the S/N ratio found in the osteoporosis group. Additionally, among the three groups, the lowest S/N ratio was found in the osteoporosis group. With respect to ADC map, it was found that for both the osteopenia group and the osteoporosis group, as T-scores deceased, the ADC values on diffusion-weighted MR images also decreased, with the greatest decrease in the ADC values found in the osteoporosis group. Additionally, among the three groups, the lowest ADC value was found in the osteoporosis group. On the other hand, in the qualitative analysis, the osteoporosis group showed the highest signal intensity. Additionally, among the three groups, the lowest signal intensity was found in the healthy (normal) group. It was found that as osteoporosis progressed, S/N ratio and ADC decreased, whereas signal intensity increased on T1-weighted images. Also, in diagnosing osteoporosis, MRI tests turned out to be (more) effective.

The quantitative analysis of Diffusion Weighted Imaging in Breast MRI (유방 MRI 검사에서 확산강조영상의 정량적 분석)

  • Cho, Jae-Hwan;Kim, Hyeon-Ju;Hong, Yin-Sik;Lee, Hae-Kag
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.3
    • /
    • pp.149-154
    • /
    • 2011
  • The purpose of this study was to examine the usefulness of diffusion weighted images in breast MRI by performing a quantitative comparative analysis in patients diagnosed with DCIS. On a 3.0T MR scanner, diffusion weighted images and ADC map images were obtained from 20 patients histologically diagnosed with ductal carcinoma in situ (DCIS). The findings from the quantitative image analysis are the following: The diffusion weighted images showed higher SNR and CNR at the lesion area. In addition, the ADC values were lower at the lesion area.