• Title/Summary/Keyword: 신호 잡음비

Search Result 1,923, Processing Time 0.03 seconds

Development of Battery-free SAW Integrated Microsensor for Real Time Simultaneous Measurement of Humidity and $CO_2$ component (습도와 $CO_2$ 농도의 실시간 동시감지를 위한 무전원 SAW 기반 집적 센서 개발)

  • Lim, Chun-Bae;Lee, Kee-Keun;Wang, Wen;Yang, Sang-Sik
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.16 no.1
    • /
    • pp.13-19
    • /
    • 2009
  • A 440MHz wireless and passive surface acoustic wave (SAW) based chemical sensor was developed on a $41^{\circ}YX\;LiNbO_3$ piezoelectric substrate for simultaneous measurement of $CO_2$ gas and relative humidity (RH) using a reflective delay line pattern as the sensor element. The reflective delay line is composed of an interdigital transducer (IDT) and several shorted grating reflectors. A Teflon AF 2400 and a hydrophilic $SiO_2$ layer were used as $CO_2$ and water vapor sensitive films. The coupling of mode (COM) modeling was conducted to determine optimal device parameters prior to fabrication. According to simulation results, the device was fabricated and then wirelessly measured using the network analyzer. The measured reflective coefficient $S_{11}$ in the time domain showed high signal/noise (S/N) ratio, small signal attenuation, and few spurious peaks. In the $CO_2$ and humidity testing, high sensitivity ($2^{\circ}/ppm$ for $CO_2$ detection and $7.45^{\circ}/%$RH for humidity sensing), good linearity and repeatability were observed in the $CO_2$ concentration ranges of $75{\sim}375ppm$ and humidity levels of $20{\sim}80%$RH. Temperature and humidity compensations were also investigated during the sensitivity evaluation process.

  • PDF

An Efficient Coding Technique of Holographic Video Signal using 3D Segment Scanning (분할영역의 3차원 스캐닝을 이용한 홀로그래픽 비디오 신호의 효율적인 부호화 기술)

  • Seo, Young-Ho;Choi, Hyun-Jun;Kim, Dong-Wook
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.2C
    • /
    • pp.132-140
    • /
    • 2007
  • In this paper, we proposed a new technique to encode and decode the digital hologram. Since the digital hologram (or fringe pattern) is generated by interference of light, it has much different property from natural 2D (2 dimensional) images. First, we acquisite optical-sensed or computer-generated hologram by digital type, and then extract a chrominance component. The extracted digital hologram for coding is separated into segments to use multi-view properties. The segmented hologram shows the similar characteristics with picturing an object with 2D cameras in various point of view. Since fringe pattern is visually observed like as noise, we expect that the fringe pattern has poor coding efficiency. To obtain high efficiency, the segment is transformed with DCT (Discrete Cosine Transform) which resembles hologram generation process with high performance. Each transformed segment passes the 3D scanning process according to time and spatial correlation, and is organized into a video stream. Since the segment which correspond to frame of a video stream consists of the transformed coefficients with wide range of value, it is classified and re-normalized. Finally it is compressed with coding tools. The proposed algorithm illustrated that it has better properties for reconstruction of 16 times higher compression rate than the previous researches.

A Study on the Development of SSB Modem (디지털 SSB 모뎀 개발에 관한 연구)

  • Kim, Jeong-Nyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.10
    • /
    • pp.1852-1857
    • /
    • 2007
  • The SSB modem performs the modulation process which converts the digital voltage level to the audible frequency band signal and the demodulation process which converts reversely the audible frequency signal to the digital voltage level. The modulator and the demodulator are implemented with a single DSP chip. Because of the SSB specific character, the distortion occurs when the frequency is changed. This distortion has no effect on voice communication but it has an significant effect on data communication. In other words, it is impossible to send data stream with adjacent 2 periods. Therefore, in case of using 2-tone FSK, it is needed to send at least 3 periods to transmit 1 bit. Therefore we implemented the modem using modified phase-delay shift keying to transmit 1 tone signal for high speed transmission. In the 1200[bps] mode, it generates 0, $187{\mu}s$, delay time at 1.3kHz symbol frequency, and in the 2400[bps] mode, 0, $70{\mu}s\;130{\mu}s\;200{\mu}s$, delay time at 1.5kHz symbol frequency. Finally, in the maximum 3600[bps] mode, it generates 0, $100{\mu}s\;160{\mu}s\;250{\mu}s$ 2.0kHz symbol frequency. The measured results of the implemented SSB modem shows a good transfer functional characteristic by spectrum analyzer, almost same bandwidth in pass band and 20dB higher SNR comparing the emu FACTOR and American CLOVER and in the experimental transmitting test, we verified the transmitted data is received correctly in platform.

Performance Test of the Iterative Method and Newly Developed True X Method (PET 검사에서 Iterative 재구성 방법과 True X 재구성 방법에 따른 영상의 균일성 및 대조도 비교 평가)

  • Choi, Jae-Min;NamKung, Chang-Kyeong;Park, Seung-Yong;Nam, Ki-Pyo;Lim, Ki-Cheon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.20-24
    • /
    • 2009
  • Objective: In this study, the differences between two reconstruction methods were analyzed by comparing image uniformity and contrast according to Iteration and Subset, which were altered through the Iterative method and True X method, used in Siemens' PET/CT studies. Methods: The Phantom images were obtained by exposure for two minutes per one bed. To determine the image uniformity, the Coefficient of variance was used. Also, in order to compare the contrast value, we measured and analyzed the ratio of the SUV mean of Phantom image's hot spheres and the background. Results: Under the same reconstruction conditions (Iteration and Subset) of CV, the Iterative method was higher than the True X method. In the comparison of the SUV mean ratio of the background and hot sphere, the True X method had a closer rate than the Iterative method. Conclusion: The newly developed True X reconstruction method is better than the previously used Iterative method in terms of uniformity and contrast. However, the date for this study was only obtained using the Phantom device. In order to obtain more accurate and useful information from the experiment, further research should be conducted. Also, it is necessary to find the appropriate standards for Iteration and Subset for further experimentation.

  • PDF

Evaluation of TOF MR Angiography and Imaging for the Half Scan Factor of Cerebral Artery (유속신호증강효과의 자기공명혈관조영술을 이용한 뇌혈관검사에서 Half Scan Factor 적용한 영상 평가)

  • Choi, Young Jae;Kweon, Dae Cheol
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.3
    • /
    • pp.92-98
    • /
    • 2016
  • To aim of this study was to assess the full scan and half scan of imaging with half scan factor. Patients without a cerebral vascular disease (n = 30) and were subject to the full scan half scan, and set a region of interest in the cerebral artery from the three regions (C1, C2, C3) in the range of 7 to 8 mm. MIP (maximum intensity projection) to reconstruct the images in signal strength SNR (signal to noise ration), PSNR (peak signal noise to ratio), RMSE (root mean square error), MAE (mean absolute error) and calculated by paired t-test for use by statistics were analyzed. Scan time was half scan (4 minutes 53 seconds), the full scan (6 minutes 04 seconds). The mean measurement range (7.21 mm) of all the ROI in the brain blood vessel, was the SNR of the first C1 is completely scanned (58.66 dB), half-scan (62.10 dB), a positive correlation ($r^2=0.503$), for the second C2 SNR is completely scanned (70.30 dB), half-scan (74.67 dB) the amount of correlation ($r^2=0.575$), third C3 of a complete scan SNR (70.33 dB), half scan SNR (74.64 dB) in the amount of correlation between the It was analyzed with ($r^2=0.523$). Comparative full scan with half of SNR ($4.75{\pm}0.26dB$), PSNR ($21.87{\pm}0.28dB$), RMSE ($48.88{\pm}1.61$), was calculated as MAE ($25.56{\pm}2.2$). SNR is also applied to examine the half-scans are not many differences in the quality of the two scan methods were not statistically significant in the scan (p-value > .05) image takes less time than a full scan was used.

Image Quality Evaluation of CsI:Tl and Gd2O2S Detectors in the Indirect-Conversion DR System (간접변환방식 DR장비에서 CsI:Tl과 Gd2O2S의 검출기 화질 평가)

  • Kong, Changgi;Choi, Namgil;Jung, Myoyoung;Song, Jongnam;Kim, Wook;Han, Jaebok
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.1
    • /
    • pp.27-35
    • /
    • 2017
  • The purpose of this study was to investigate the features of CsI:Tl and $Gd_2O_2S$ detectors with an indirect conversion method using phantom in the DR (digital radiography) system by obtaining images of thick chest phantom, medium thickness thigh phantom, and thin hand phantom and by analyzing the SNR and CNR. As a result of measuring the SNR and CNR according to the thickness change of the subject, the SNR and CNR were higher in CsI:Tl detector than in $Gd_2O_2S$ detector when the medium thickness thigh phantom and thin hand phantom were scanned. However, when the thick chest phantom was used, for the SNR at 80~125 kVp and the CNR at 80~110 kVp in the $Gd_2O_2S$ detector, the values were higher than those of CsI:Tl detector. The SNR and CNR both increased as the tube voltage increased. The SNR and CNR of CsI:Tl detector in the medium thickness thigh phantom increased at 40~50 kVp and decreased as the tube voltage increased. The SNR and CNR of $Gd_2O_2S$ detector increased at 40~60 kVp and decreased as the tube voltage increased. The SNR and CNR of CsI:Tl detctor in the thin hand phantom decreased at the low tube voltage and increased as the tube voltage increased, but they decreased again at 100~110 kVp, while the SNR and CNR of $Gd_2O_2S$ detector were found to decrease as the tube voltage increased. The MTF of CsI:Tl detector was 6.02~90.90% higher than that of $Gd_2O_2S$ detector at 0.5~3 lp/mm. The DQE of CsI:Tl detector was 66.67~233.33% higher than that of $Gd_2O_2S$ detector. In conclusion, although the values of CsI:Tl detector were higher than those of $Gd_2O_2S$ detector in the comparison of MTF and DQE, the cheaper $Gd_2O_2S$ detector had higher SNR and CNR than the expensive CsI:Tl detector at a certain tube voltage range in the thick check phantom. At chest X-ray, if the $Gd_2O_2S$ detector is used rather than the CsI:Tl detector, chest images with excellent quality can be obtained, which will be useful for examination. Moreover, price/performance should be considered when determining the detector type from the viewpoint of the user.

Analysis of the ESD and DAP According to the Change of the Cine Imaging Condition of Coronary Angiography and Usefulness of SNR and CNR of the Images: Focusing on the Change of Tube Current (관상동맥 조영술(Coronary Angiography)의 씨네(cine) 촬영조건 변화에 따른 입사표면선량(ESD)과 흡수선량(DAP) 및 영상의 SNR·CNR 유용성 분석: 관전류 변화를 중점으로)

  • Seo, Young Hyun;Song, Jong Nam
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.371-379
    • /
    • 2019
  • The purpose of this study was to investigate the effect of the change in the X-ray condition on the entrance surface dose (ESD) and dose area product (DAP) in the cine imaging of coronary angiography (CAG), and to analyze the usefulness of the condition change on the dose relation and image quality by measuring and analyzing the Signal to Noise Radio (SNR) and Contrast to Nois Ratio (CNR) of the angiographic images taken by the Image J program. Data were collected from 33 patients (24 males and 9 females) who underwent CAG at this hospital from November 2017 to March 2018. In terms of imaging condition and data acquisition, the ESD and DAP of group A with a high tube current of 397.2 mA and group B with a low tube current of 370.7 mA were retrospectively obtained for comparison and analysis. For the SNR and CNR measurement and analysis via Image J, the result values were derived by substituting the obtained data into the formula. The correlations among ESD and DAP according to the change in the imaging condition, SNR, and CNR were analyzed by using the SPSS statistical analysis software. The relationships of groups A and B, having a difference in the imaging condition, mA, with ESD ($A:483.5{\pm}60.1$; $B: 464.4{\pm}39.9$) and DAP ($A:84.3{\pm}10.7$; $B:81.5{\pm}7$) were not statistically significant (p>0.05). In the relationships with SNR and CNR based on Image J, the SNR ($5.451{\pm}0.529$) and CNR ($0.411{\pm}0.0432$) of the images obtained via the left coronary artery (LCA) imaging of group B showed differences of $0.475{\pm}0.096$ and $-0.048{\pm}0.0$, respectively, from the SNR ($4.976{\pm}0.433$) and CNR ($0.459{\pm}0.0431$) of the LCA of group A. However, the differences were not statistically significant (p<0.05). In the SNR and CNR obtained via the right coronary artery (RCA) imaging, the SNR ($4.731{\pm}0.773$) and CNR ($0.354{\pm}0.083$) of group A showed increased values of $1.491{\pm}0.405$ and $0.188{\pm}0.005$, respectively, from the SNR ($3.24{\pm}0.368$) and CNR ($0.166{\pm}0.033$) of group B. Among these, CNR was statistically significant (p<0.05). In the correlation analysis, statistically significant results were shown in SNR (LCA) and CNR (LCA); SNR (RCA) and CNR (RCA); ESD and DAP; ESD and sec; DAP and CNR (RCA); and DAP and sec (p<0.05). As a result of the analyses on the image quality evaluation and usefulness of the dose change, the SNR and CNR were increased in the RCA images of the CAG obtained by increasing the mA. Based on the result that CNR showed a statistically significant difference, it is believed that the contrast in the image quality can be further improved by increasing the mA in RCA imaging.

A Study on Bismuth tri-iodide for X-ray direct and digital imagers (직접방식 엑스선 검출기를 위한 $BiI_3$ 특성 연구)

  • Lee, S.H.;Kim, Y.S.;Kim, Y.B.;Jung, S.H.;Park, J.K.;Jung, W.B.;Jang, M.Y.;Mun, C.W.;Nam, S.H.
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.2
    • /
    • pp.27-31
    • /
    • 2009
  • Now a days, the Medical X-ray equipments has become digitalized from analog type such as film, cassette to CR, DR. And many scientists are still researching and developing the Medical X-ray equipment. In this study, we used the Bismuth tri-iodide to conversion material for digital X-ray equipments and we couldn't get the satisfying result than previous study, but it opened new possibility to cover the disadvantage of a-Se is high voltage aplly and difficultness of make. In this paper, we use $BiI_3$ powder(99.99%) as x-ray conversion material and make films that have thickness of 200um and the film size is $3cm{\times}3cm$. Also, we deposited an ITO(Indium Tin Oxide) electrode as top electrode and bottom electrode using a Magnetron Sputtering System. To evaluate a characteristics of the produced films, an electrical and structural properties are performed. Through a SEM analysis, we confirmed a surface and component part. And to analyze the electrical properties, darkcurrent, sensitivity and SNR(Signal to Noise Ratio) are measured. Darkcurrent is $1.6nA/cm^2$ and sensitivity is $0.629nC/cm^2$ and this study shows that the electrical properties of x-ray conversion material that made by screen printing method are similar to PVD method or better than that. This results suggest that $BiI_3$ is suitable for a replacement of a-Se because of the reduced manufacture processing and improved yield.

  • PDF

A Study on Usefulness of Specific Agents with Liver Disease at MRI Imaging: Comparison with Ferucarbotran and Gd-EOB-DTPA Contrast Agents (간 병변 특이성 조영제 자기공명영상에 대한 연구: Ferucarbotran과 Gd-EOB-DTPA 조영제의 비교)

  • Lee, Jae-Seung;Goo, Eun-Hoe;Park, Cheol-Soo;Lee, Sun-Yeob;Choi, Yong-Seok
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.235-243
    • /
    • 2009
  • The purpose of this experiment is to know the relation of the detection and characterization of liver's diseases as comparison of finding at MR imaging using a Ferucarbotran (SPIO) and Gd-EOB-DTPA (Primovist) agents in diffuse liver disease. A total of 50 patients (25 men and 25 women, mean age: 50 years) with liver diseases were investigated at 3.0T machine (GE, General Electric Medical System, Excite HD) "with 8 Ch body coil for comparison of diseases and contrast's uptake relation, which used the LAVA, MGRE." All images were performed on the same location with before and after Ferucarbotran and Gd-EOB-DTPA administrations (p<0.05). Contrast to noise ratio of Ferucarbotran and Gd-EOB-DTPA in the HCC were $3.08{\pm}0.12$ and $7.00{\pm}0.27$ with MGRE and LAVA pulse sequence, $3.62{\pm}0.13$ and $2.60{\pm}0.23$ in the hyper-plastic nodule, $1.70{\pm}0.09$ and $2.60{\pm}0.23$ in the meta, $2.12{\pm}0.28$ and $5.86{\pm}0.28$ in the FNH, $4.45{\pm}0.28$ and $1.73{\pm}0.02$ in the abscess and ANOVA test was used to evaluate the diagnostic performance of each disease (p<0.05). In conclusions, two techniques were well demonstrated with the relation of the detection and characterization of liver's diseases.

  • PDF

Comparison of the DGPS Positioning Accuracies for Single and Multiple Reference Stations in the South Coast of Korea (한국 남해안에서 단일 및 복수 기준국에 의한 DGPS의 측위정도 비교)

  • Park, Noh-Seon;Shin, Hyeong-Il;Lee, Dae-Jae;Shin, Hyeon-Ok;Kim, Seok-Jae;Bae, Mun-Ki
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.38 no.3
    • /
    • pp.181-189
    • /
    • 2002
  • This paper describes the positioning accuracies for single and multiple reference stations at fixed stations in Yosu harbor and Pukyong National University in the south coast of Korea from Jan. to Oct. 2001. Also we observed the change of positioning accuracy during a day and the available range of the DGPS reference station. he results obtained are main summarized as follows; 1. With single DGPS reference station, 2drms and the average positioning .error were 5.6m, 7.3m respectively. Measurement positions indicated an incline toward one way away from the actual position. 2. With multiple DGPS reference stations, 2drms and the average position error were 5.5m, 3.2m for the arithmetic mean, respectively. They were 5.3m, 3.8m for the weighted average, respectively. As far as the separation between the user and the reference station, using multiple reference stations improved position accuracy more than using single reference station. 3. The average positioning error increased between 16: 00 and 22 : 00. The average number of observed satellite and HDOP were 7.1m, 0.49 respectively. 4. Coverage of DGPS reference stations in the south coast of Korea was estimated to be 110nm. Signal strength and signal to noise ratio was not available the DGPS signal below 19㏈, 8㏈ respectively.