• Title/Summary/Keyword: 신호 검출

Search Result 3,064, Processing Time 0.034 seconds

A study on the implementation of Medical Telemetry systems using wireless public data network (무선공중망을 이용한 의료 정보 데이터 원격 모니터링 시스템에 관한 연구)

  • 이택규;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.10a
    • /
    • pp.278-283
    • /
    • 2000
  • As information communication technology developed we could check our blood pressure, pulsation electrocardiogram, SpO2 and blood test easily at home. To check our health at ordinary times is able though interlocking the house medical instrument with the wireless public data network This service will help the inconvenience to visit the hospital everytime and will save the individual's time and cost. In each house an organism data which is detected from the human body will be transmitted to the distance hospital and will be essentially applied through wireless public data network The medical information transmit system is utilized by wireless close range network It would transmit the obtained organism signal wirelessly from the personal device to the main center system in the hospital. Remote telemetry system is embodied by utilizing wireless media access protocol. The protocol is embodied by grafting CSMA/CA(Carrier Sense Multiple Access with Collision Avoidance) protocol falling mode which is standards from IEEE 802.11. Among the house care telemetry system which could measure blood pressure, pulsation, electrocardiogram, SpO2 the study embodies the ECC(electrocardiograph) measure part. It within the ECC function into the movable device and add 900㎒ band wireless public data interface. Then the aged, the patients even anyone in the house could obtain ECG and keep, record the data. It would be essential to control those who had a health-examination heart diseases or more complicated heart diseases and to observe the latent heart disease patient continuously. To embody the medical information transmit system which is based on wireless network. It would transmit the ECG data among the organism signal data which would be utilized by wireless network modem and NCL(Native Control Language) protocol to contact through wireless network Through the SCR(Standard Context Routing) protocol in the network it will be connected to the wired host computer. The computer will check the recorded individual information and the obtained ECC data then send the correspond examination to the movable device. The study suggests the medical transmit system model utilized by the wireless public data network.

  • PDF

Timing Driven Analytic Placement for FPGAs (타이밍 구동 FPGA 분석적 배치)

  • Kim, Kyosun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.7
    • /
    • pp.21-28
    • /
    • 2017
  • Practical models for FPGA architectures which include performance- and/or density-enhancing components such as carry chains, wide function multiplexers, and memory/multiplier blocks are being applied to academic FPGA placement tools which used to rely on simple imaginary models. Previously the techniques such as pre-packing and multi-layer density analysis are proposed to remedy issues related to such practical models, and the wire length is effectively minimized during initial analytic placement. Since timing should be optimized rather than wire length, most previous work takes into account the timing constraints. However, instead of the initial analytic placement, the timing-driven techniques are mostly applied to subsequent steps such as placement legalization and iterative improvement. This paper incorporates the timing driven techniques, which check if the placement meets the timing constraints given in the standard SDC format, and minimize the detected violations, with the existing analytic placer which implements pre-packing and multi-layer density analysis. First of all, a static timing analyzer has been used to check the timing of the wire-length minimized placement results. In order to minimize the detected violations, a function to minimize the largest arrival time at end points is added to the objective function of the analytic placer. Since each clock has a different period, the function is proposed to be evaluated for each clock, and added to the objective function. Since this function can unnecessarily reduce the unviolated paths, a new function which calculates and minimizes the largest negative slack at end points is also proposed, and compared. Since the existing legalization which is non-timing driven is used before the timing analysis, any improvement on timing is entirely due to the functions added to the objective function. The experiments on twelve industrial examples show that the minimum arrival time function improves the worst negative slack by 15% on average whereas the minimum worst negative slack function improves the negative slacks by additional 6% on average.

Development and Utility Evaluation of Portable Respiration Training Device for Image-guided Stereotactic Body Radiation Therapy (SBRT) (영상유도 체부정위방사선 치료시 호흡동조를 위한 휴대형 호흡연습장치의 개발 및 유용성 평가)

  • Hwang, Seon Bung;Park, Mun Kyu;Park, Seung Woo;Cho, Yu Ra;Lee, Dong Han;Jung, Hai Jo;Ji, Young Hoon;Kwon, Soo-Il
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.264-270
    • /
    • 2014
  • This study developed a portable respiratory training device to improve breathing stability, which is an important element in using the CyberKnife Synchrony respiratory tracking device, one of the typical Stereotactic Radiation Therapy (SRT) devices. It produced an interface for users to be able to select one of two displays, a graph type and a bar type, supported an auditory system that helps them expect next respiration by improving a sense of rhythm of their respiratory period, and provided comfortable respiratory inducement. By targeting 5 applicants and applying individual respiratory period detected through a self-developed program, it acquired signal data of 'guide respiration' that induces breathing through signal data gained from 'free respiration' and an auditory system, and evaluated the usability by comparing deviation average values of respiratory period and respiratory amplitude. It could be identified that respiratory period decreased $55.74{\pm}0.14%$ compared to free respiration, and respiratory amplitude decreased $28.12{\pm}0.10%$ compared to free respiration, which confirmed the consistency and stability of respiratory. SBRT, developed based on these results, using the portable respiratory training device, for liver cancer or lung cancer, is evaluated to be able to help reduce delayed treatment time due to respiratory instability and improve treatment accuracy, and if it could be applied to developing respiratory training applications targeting an android-based portable device in the future, even use convenience and economic efficiency are expected.

A Comparative Study of Subset Construction Methods in OSEM Algorithms using Simulated Projection Data of Compton Camera (모사된 컴프턴 카메라 투사데이터의 재구성을 위한 OSEM 알고리즘의 부분집합 구성법 비교 연구)

  • Kim, Soo-Mee;Lee, Jae-Sung;Lee, Mi-No;Lee, Ju-Hahn;Kim, Joong-Hyun;Kim, Chan-Hyeong;Lee, Chun-Sik;Lee, Dong-Soo;Lee, Soo-Jin
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.3
    • /
    • pp.234-240
    • /
    • 2007
  • Purpose: In this study we propose a block-iterative method for reconstructing Compton scattered data. This study shows that the well-known expectation maximization (EM) approach along with its accelerated version based on the ordered subsets principle can be applied to the problem of image reconstruction for Compton camera. This study also compares several methods of constructing subsets for optimal performance of our algorithms. Materials and Methods: Three reconstruction algorithms were implemented; simple backprojection (SBP), EM, and ordered subset EM (OSEM). For OSEM, the projection data were grouped into subsets in a predefined order. Three different schemes for choosing nonoverlapping subsets were considered; scatter angle-based subsets, detector position-based subsets, and both scatter angle- and detector position-based subsets. EM and OSEM with 16 subsets were performed with 64 and 4 iterations, respectively. The performance of each algorithm was evaluated in terms of computation time and normalized mean-squared error. Results: Both EM and OSEM clearly outperformed SBP in all aspects of accuracy. The OSEM with 16 subsets and 4 iterations, which is equivalent to the standard EM with 64 iterations, was approximately 14 times faster in computation time than the standard EM. In OSEM, all of the three schemes for choosing subsets yielded similar results in computation time as well as normalized mean-squared error. Conclusion: Our results show that the OSEM algorithm, which have proven useful in emission tomography, can also be applied to the problem of image reconstruction for Compton camera. With properly chosen subset construction methods and moderate numbers of subsets, our OSEM algorithm significantly improves the computational efficiency while keeping the original quality of the standard EM reconstruction. The OSEM algorithm with scatter angle- and detector position-based subsets is most available.

The Evaluation of the Radiation Dose and Image Quality Through the Change of the Tube Voltage in Cerebral CT Angiography (전산화단층촬영장치를 이용한 뇌 혈관조영 검사에서 관전압 변화에 따른 방사선량과 영상의 질 평가)

  • LEE, Ji-Won;Jung, Kang-Kyo;Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.38 no.2
    • /
    • pp.121-126
    • /
    • 2015
  • To image diagnosis in neurovascular diseases using Multi-Detector Computed Tomography(MDCT), injected the same contrast material when inspecting Brain Computed Tomography Angiography(BCTA) to examine radiation dose and Image quality on changing Cerebral Artery CT number by tube voltage. Executed an examination with same condition[Beam Collimation $128{\times}0.6mm$, Pitch 0.6, Rotation Time 0.5s, Slice Thickness 5.0mm, Increment 5.0mm, Delay Time 3.0sec, Care Dose 4D(Demension ; D)] except for tube voltage on 50 call patients for BCTA and divided them into two groups (25 people for a group, group A: 80, group B: 120kVp). From all the acquired images, set a ROI(Region of Interest) on four spots such as left cerebral artery, right cerebral artery, posterior cerebral artery and cerebral parenchyma to compare quantitative evaluation, qualitative evaluation and effective dose after measuring CT number value from Picture Archiving Communications System(PACS). Evaluating images with CT number acquired from BCTA examination, images with 80 kVp was 18% higher in Signal to Noise Ratio and 19% in Contrast to Noise Ratio than those with 120 kVp. It was seen that expose dose was decreased by over 50% with tube voltage 80 kVp than with 120 kVp. Group A (25 patients) was examination with tube voltage 80kVp while group B with 120 kVp to examine radiation dose and Image quality. It is considered effective to inspect with lower tube voltage than with conventional high kVp, which can reduce radiation dose without any affect on diagnosis.

Disturbance of $\alpha$-Amylase Secretion from Bacillus amyloliquefaciens Cells by the Treatment of Puromycin and Magnesium (Bacillus amyloliquefaciens에서 Puromycin 과 Magnesium에 의한 $\alpha$-Amylase 의 분비저해)

  • 안순자;김순옥;이동희;송방호
    • Microbiology and Biotechnology Letters
    • /
    • v.17 no.5
    • /
    • pp.412-420
    • /
    • 1989
  • To know how the ribosomes involved in secretory protein synthesis were attached to the cytoplasmic membrane in Bacillus amyloliquefaciens, the cells were treated with puromycin combinated with magnesium at the logarithmic phase, and the variation of cell-bound and extracellular $\alpha$-amylase activity was assayed for determining the $\alpha$-amylase translocation blocking through the cytoplasmic membrane. In the abnormal $\alpha$-amylase producing mutant in which the C-terminal of the $\alpha$-amylase structure was deleted, B. umytotiquefaciens CH10-2, the $\alpha$-amylase was translocated normally through the cytoplasmic membranes, and the translocation blocking by puromycin was revealed to have a similar pattern as that in the wild type. This means that the C-terminal part of the enzyme structure may not have a signal for secretion. The cell death of the logarithmic phase cells in both strains was not affected much under 20$\mu\textrm{g}$/$m\ell$ of puromycin, however, the $\alpha$-amylase translocation was blocked markedly under less than 10$\mu\textrm{g}$/$m\ell$ of the puromycin concentration. The blocking of the enzyme secretion by puromycin may be due to the detachment of the ribosomes from cytoplasmic membranes by disturbing the nascent polypeptide synthesis. Further evidence for confirming this was that the detachment was increased in 50 mM of magnesium ion because the extracellular $\alpha$-amylase activity was decreased more under this condition. If the cells were treated with trypsin combinated with Iysozyme, the extracellular $\alpha$-amylase activity from the cultured medium was reduced markedly, however, the activity from the cells treated with trypsin only was not reduced. This means that the nascent polypeptides protruding from the cytoplasmic membrane were sensitive to the trypsin digestion, whereas the matured ones were not. Therefore, the protruding polypeptides from the cytoplasmic membranes may be truncated by trypsin before forming their final tertiary structures by folding in the cell wall layer.

  • PDF

Susceptibility Weighted Image for Stem Cell Tracking in Rat Photothrombotic Infarction (흰쥐 광 혈전 뇌경색 모델에서 줄기세포 추적을 위한 자화강조영상)

  • Ha, Bon-Chul;Lim, Cheong-Hwan
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.8
    • /
    • pp.249-256
    • /
    • 2010
  • To the detect of SPIO-labelled hMSC, in vitro study on various cell concentration and in vivo molecular magnetic resonance imaging(MRI) technique using T2, $T2^*$ and SWI are compared with pathology. Cell concentration was $1.56{\times}10^4$, $3.13{\times}10^4$, $6.25{\times}10^4$, $1.25{\times}10^5$, $2.5{\times}10^5$, $5{\times}10^5\;cells/m{\ell}$ and for control $5{\times}10^5\cells/m{\ell}$. MRI technique using T2, $T^2$ and SWI. Photothrombotic infarction was located 2.5mm from bregma right, posterior. Cell injected through the tail vein of rat for 8 rats. MRI performed pre injection and post injection of 1, 3, 7 and 14days and sacrifice for pathology. MRI analysed on quantitatively. In vitro result, SWI was highest CNR as compared with $T2^*WI$, T2WI and $2.5{\times}10^5\;cells/m{\ell}$ cell concentration. In vivo result among the T2WI, $T2^WI$, SWI, T2WI is highest CNR between normal and infarction. CNR in normal-SPIO and infarction-SPIO is high score in SWI. Therefore, T2WI is good distinguish between normal and infarction, SWI are well detect SPIO-labelled hMSC from normal and infarction. Nowaday, SWI are mostly used on hemorrhage, calcification etc. in clinically, but for the future, stem cell therapy is commonly application at all disease which is good observing tool for SPIO-labelled stem cells.

The Effects of Image Quality due to Scattering X-ray according to increasing Patient Thickness (피사체 두께에 따른 산란선 발생이 화질에 미치는 영향)

  • Park, Ji-Koon;Yang, Sung-Woo;Jun, Jae-Hoon;Cho, Su-Yeon;Kim, Kyo-Tae;Heo, Ye-Ji;Kang, Sang-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.671-677
    • /
    • 2017
  • In this study, scattering factors affecting the quality of medical images were quantitatively analyzed and investigated. MCNPX simulation was conducted by using ANSI phantom, made of tissue equivalent materials, to calculate the scattering ratio occurred by the increase of the object thickness. Then, the result of the simulation was compared with the result of actual radiation measurement. In addition, we evaluated the image quality by the RMS evaluation, RSD and NPS analysis using X-ray images acquired with increasing object thickness. Furthermore, the scattering ratio was analyzed by increasing the thickness of acrylic phantom on chest phantom. The result showed that the scattering ratio was increased to 57.2%, 62.4%, and 66.8% from 48.9%, respectively, when the acrylic phantom thickness was increased by 1 inch from 6.1 inches. The results of MCNPX simulation and the actual measured scattering dose showed similar results. Also, as a result of RMS measurement from acquired x-ray images, the standard deviation decreased as the object thickness increased. However, in the RSD analysis considering the average incident dose, the results were increased from 0.028 to 0.039, 0.051, 0.062 as the acrylic phantom thickness was increased from 6.1 inches to 7.1 inch, 8.1 inch, and 9.1 inch, respectively. It can be seen that the increase of the scattering effect due to the increase of the object thickness reduces the SNR. Also, the NPS results obtained by measuring scattered radiation incident on the detector resulted in the increase of the noise as the object thickness increased.

Analysis and risk assessment of polycyclic aromatic hydrocarbons (PAHs) in seafood from oil contaminated bay (유류 오염지역의 수산물 중 다환방향족탄화수소류 (PAHs) 분석 및 위해평가)

  • Jeong, Ji-Yoon;Choi, Chan-Woong;Ryeom, Tai-Kyung;Cho, Kyoung-Hee;Park, Se-Ryung;Shin, Ho-Sang;Lee, Kwang-Ho;Lee, Hyo-Min
    • Analytical Science and Technology
    • /
    • v.23 no.2
    • /
    • pp.187-195
    • /
    • 2010
  • To assess health risk for the intake among residents after the Hebei Spirit oil spill, 16 Polycyclic Aromatic Hydrocarbons (PAHs) in seafood samples from oil contaminated bay were determined by Gas Chromatography-Mass Spectrometry (GC-MSD) and samples were personally collected and purchased by residents. Samples were hydrolyzed with KOH and extracted with methylene chloride. The extracted solution were cleaned up using silica/florisil column and 16 PAHs were eluted by methylene chloride : n-hexane (1:9) mixture and determined by GC-MSD in Selected Ion Monitoring (SIM) mode. The mean recoveries for 16 PAHs ranged from 79% to 85%. The 16 PAHs levels in 126 samples ranged from 0.17 to $6.04\;{\mu}g$/kg and the TEQBaP (Toxic EQuivalents) levels in 126 samples were calculated using benzo(a)pyrene toxic equivalency factor for individual 16 PAHs and ranged from 0 to $0.91\;{\mu}gTEQ$/kg. The average Benzo(a)pyrene dietary exposure of residents was $5.5{\times}10^{-8}\;mg/kg$ bw/day and the average PAHs chronic dietary exposure was $1.3{\times}10^{-5}\;mg$ TEQ/kg bw/day. The margin of exposure (MOE) and the excess cancer risk and were $1.8{\times}10^6$ and $9.8{\times}10^{-8}$, respectively. Therefore, the assessment result was considered as low concern for health risk.

Improvement on Fish Odor of Extracts from Salmon Frame Soaked in Soybean Milk (두유 전처리에 의한 열수추출 연어 Frame 엑스분의 비린내 개선)

  • Heu, Min-Soo;Park, Shin-Ho;Kim, Hye-Suk;Kim, Hyung-Jun;Han, Byung-Wook;Ji, Seong-Gil;Kim, Jeong-Gyun;Yoon, Min-Seok;Kim, Jin-Soo
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.37 no.2
    • /
    • pp.223-230
    • /
    • 2008
  • For the use of extracts from salmon frame as a basic material of Gomtang-like products, various methods (soaking into soybean milk, adding anchovy, and adding spices) for masking fish odor into extracts from salmon frame were examined and the food component characteristics were also compared with commercial Gomtang. According to the results of volatile basic nitrogen, transmission at 660 nm and sensory evaluation of extracts, soaking treatment, which is the soaking of salmon frame into soybean milk, was the most efficient method among the various methods for masking fish odor into extracts from salmon frame. There was no difference in the proximate composition between extracts from salmon frame soaked (FS) and unsoaked (C) into soybean milk. The FS was not detected in heavy metals, such as chromium, lead and cadmium. The taste value of FS (16.26) was higher than that of C and the major amino acids were glutamic acid and aspartic acid. Total amino acid content of FS (3.08 g/100 mL) was also higher than those of C (2.95 g/100 mL) and commercial Gomtang (1.70 g/100 mL), and the major amino acids were glycine, proline, glutamic acid and arginine. The calcium and phosphorus contents of FS/500 mL accounted for 21.7% and 18.5%, respectively, of the recommended daily allowance of mineral for adult.