• Title/Summary/Keyword: 신호처리 및 필터링

Search Result 123, Processing Time 0.023 seconds

An Electronic System in Automatic Refracto-Keratometer (자동 시각 굴절력 곡률계의 전자 부문 시스템)

  • Seong, Won;Ryu, Gang-Min;Park, Jong-Won
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.8 no.6
    • /
    • pp.669-678
    • /
    • 2002
  • Currently, the domestic interests on the development of eyesight related measuring instruments are being increased. So we are developing such an electronic system of Refracto-keratometer, which contains a software and a hardware both. If this system could inform the examiner of the precise eyesight measuring result from the treatment of the image of optical system, then potentially the number of missed measuring results could be reduced. Our electronic system has been developed from the two areas divided into a software and a hardware. The software area was focused on the more exact eyesight measuring results, using morphological filtering methods and gray-leveled signal enhancing techniques. The hardware area is performing the same functions as the existing other systems. Besides, it provides the embedded software with free variables which could reduce the developing duration sharply as well as enlarge many kinds of application-extensions. Therefore, this electronic system has made effective eyesight measurement possible as the result of reducing the differences applied to sophisticated eyesight measurement.

The Basic Study on the Method of Acoustic Emission Signal Processing for the Failure Detection in the NPP Structures (원전 구조물 결함 탐지를 위한 음향방출 신호 처리 방안에 대한 기초 연구)

  • Kim, Jong-Hyun;Korea Aerospace University, Jae-Seong;Lee, Jung;Kwag, No-Gwon;Lee, Bo-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.5
    • /
    • pp.485-492
    • /
    • 2009
  • The thermal fatigue crack(TFC) is one of the life-limiting mechanisms at the nuclear power plant operating conditions. In order to evaluate the structural integrity, various non-destructive test methods such as radiographic test, ultrasonic test and eddy current are used in the industrial field. However, these methods have restrictions that defect detection is possible after the crack growth. For this reason, acoustic emission testing(AET) is becoming one of powerful inspection methods, because AET has an advantage that possible to monitor the structure continuously. Generally, every mechanism that affects the integrity of the structure or equipment is a source of acoustic emission signal. Therefore the noise filtering is one of the major works to the almost AET researchers. In this study, acoustic emission signal was collected from the pipes which were in the successive thermal fatigue cycles. The data were filtered based on the results from previous experiments. Through the data analysis, the signal characteristics to distinguish the effective signal from the noises for the TFC were proven as the waveform difference. The experiment results provide preliminary information for the acoustic emission technique to the continuous monitoring of the structure failure detection.

Smart-clothes System for Realtime Privacy Monitoring on Smart-phones (스마트폰에서 실시간 개인 모니터링을 위한 스마트의류 시스템)

  • Park, Hyun-Moon;Jeon, Byung-Chan;Park, Won-Ki;Park, Soo-Hyun;Lee, Sung-Chul
    • Journal of Korea Multimedia Society
    • /
    • v.16 no.8
    • /
    • pp.962-971
    • /
    • 2013
  • In this paper, we propose a method to infer the user's behavior and situation through collected data from multi-sensor equipped with a smart clothing and it was implemented as a smart-phone App. This smart-clothes is able to monitor wearer users' health condition and activity levels through the gyro, temp and acceleration sensor. Sensed vital signs are transmitted to a bluetooth-enabled smart-phone in the smart-clothes. Thus, users are able to have real time information about their user condition, including activities level on the smart-application. User context reasoning and behavior determine is very difficult using multi-sensor depending on the measured value of the sensor varies from environmental noise. So, the reasoning and the digital filter algorithms to determine user behavior reducing noise and are required. In this paper, we used Multi-black Filter and SVM processing behavior for 3-axis value as a representative value of one.

The Development of Signal Processing Software for Single-and Multi-Voxel MR Spectroscopy (단위용적 및 다용적 기법 자기공명분광 신호처리 분석 소프트웨어의 개발)

  • Paik, Moon-Young;Lee, Hyun-Yong;Shin, Oun-Jae;Eun, Choong-Ki;Mu, Chi-Woong
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.39 no.5
    • /
    • pp.544-555
    • /
    • 2002
  • The aim of this study is to develop the $^1H$-MRS data postprocessing software for both single-voxel and multi-voxel technique, which plays and important role as a diagnostic tool in clinical field. This software is based on graphical user interface(GUI) under windows operating system of personal computer(PC). In case of single-voxel MRS, both of raw data in time-domain and spectrum data in frequency-domain are simultaneously displayed in a screen. Several functions such as DC correction, zero filling, line broadening, Lorentz-Gauss filtering and phase correction, etc. are included to increase the quality of spectrum data. In case of multi-voxel analysis, spectroscopic image reconstructed by 3-D FFT was displayed as a spectral grid and overlapped over previously obtained T1- or T2-weighted image for the spectra to be spatially registered with the image. The analysis of MRS peaks were performed by obtaining the ratio of peak area. In single-voxel method, statistically processed peak-area ratios of MRS data obtained from normal human brain are presented. Using multi-voxel method, MR spectroscopic image and metabolite image acquired from brain tumor are demonstrated.

Noise Removal with Spatial Characteristics in Mixed Noise Environment (복합 잡음 환경에서 공간적 특성을 고려한 잡음 제거)

  • Cheon, Bong-Won;Kim, Nam-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.3
    • /
    • pp.254-260
    • /
    • 2019
  • Recently, the importance of signal processing has become gradually significant, as the frequency of video media increases in various fields. However, numerous kinds of noise generated in the transmission and reception processes can possibly affect the signal information, and the noise removal is for that reason essential as a preprocessing step. In this paper, we propose an algorithm to remove the mixed noise which is composed of impulse noise and AWGN. This algorithm is used for image restoration by noise judgment for efficient noise removal in a complex noise environment, and the noise is removed by considering spatial characteristics and pixel variations. Simulation results show that unlike existing methods, the algorithm has excellent noise cancellation characteristics by minimizing both noise effects and consequently eliminating the mixed noise; for objective judgment, we compared and analyzed the data using PSNR and profile.

Two-Channel Multiwavelet Transform and Pre/Post-Filtering for Image Compression (영상 데이터 압축을 위한 2-채널 멀티웨이브렛 변환과 전후처리 필터의 적용)

  • Heo, Ung;Choi, Jae-Ho
    • Journal of the Korea Computer Industry Society
    • /
    • v.5 no.5
    • /
    • pp.737-746
    • /
    • 2004
  • Two-channel multiwavelet system is investigated for image compression application in this paper. Generally, multiwavelets are known for their superb capability of compressing non-stationary signals like voice. However, multivavelet system have a critical problem in processing and compressing image data due to mesh-grid visual artifacts. In our two-channel multiwavelet system we have investigated incorporation of pre and post filtering to the multiwavelet transform and compression system for alleviating those ingerent visual artifacts due to multiwavelet effect. In addition, to quantify the image data compression performance of proposed multiwavelet system, computer simulations have been performed using various image data. For bit allocation and quantization, the Lagrange multiplier technique considering data rate vs. distortion rate along with a nonlinear companding method are applied equallly to all systems considered, here. The simulation results have yielded 1 ~ 2 dB compression enhancement over the scalar savelet systems. If the more advanced compression methods like SPIHT and run-length channel coding were adopted for the proposed multiwavelet system, a much higher compression gain could be obtained.

  • PDF

A gene filtering method based on fuzzy pattern matching for whole genome microarray data analysis (마이크로어레이 데이터의 게놈수준 분석을 위한 퍼지 패턴 매칭에 의한 유전자 필터링 방법)

  • Lee, Seon-A;Lee, Geon-Myeong;Lee, Seung-Ju;Kim, Won-Jae;Kim, Yong-Jun;Bae, Seok-Cheol
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2007.11a
    • /
    • pp.145-148
    • /
    • 2007
  • 생명과학분야에서 마이크로어레이 기술은 세포에서의 RNA 발현 프로파일을 관찰할 수 있도록 함으로써 생명현상의 규명 및 약물개발 둥에서 분자수준의 생명현상에 대한 관찰과 분석이 가능 해지고 있다. 마이크로어레이 데이터분석에서는 특정한 처리나 과정에서 현저한 특성을 보이는 유전자를 식별하기 위한 분석뿐만 아니라 유전자 전체인 게놈수준에서의 분석도 이루어진다. 최근 유전자의 발현이 다양한 조절, 신호전달 및 대사경로에 의해서 영향을 받고 있다는 관점에서 게놈수준의 분석에 관심이 증가하고 있다. 약물반응 실험에서는 약물에 대한 게놈수준의 발현 프로파일을 관찰하는 것도 많은 정보를 제공할 수 있다. 약물실험에서는 대조군과 실험군들간에 관심 있는 상대적인 발현특성을 갖는 유전자군을 전체적으로 추출하는 것이 필요한 경우가 있다. 예를 들면 정상군은 두개의 실험군에 대해서 중간청도의 발현정도를 갖는 유전자군을 식별하는 분석을 하는 경우, 생물학적인 데이터의 특성상 절대값을 비교하는 방법으로는 유용한 유전자들을 효과적으로 식별해 낼 수 없다. 이 논문에서는 정상군과 실험군들의 발현정도값의 경향을 판단하기 위해서 각 유전자에 대해서 집단별 대표값을 선정하여 퍼지집합으로 집단의 값의 범위를 결정하고, 이를 이용하여 특정 패턴을 갖는 유전자들을 식별해내는 방법을 제안하고, 실제 데이터를 통해서 실험한 결과를 보인다.

  • PDF

Active Noise Control in Ductilike System using Adaptive Filtering (적응필터링에 의한 덕트계의 능동소음제어)

  • 이태연;김상명;송원식;오재응
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1991.04a
    • /
    • pp.17-22
    • /
    • 1991
  • 최근 기계장치로부터 발생하는 소음을 감소시키는 새로운 방법으로서, 능동 적으로 소음을 제어하는 방법에 대한 연구가 활발히 진행되고 있다. 이것은 원하지 않는 소음을 그 신호의 역위상을 갖는 부가음을 이용하여 능동적으 로 감쇠시키는 방법으로서, 저주파수 대역에서 비효율적인 수동적인 방법인 소음기둥에 대한 대안으로 많은 학자들의 관심의 대상이 되어 왔다. 초기에 는 소음을 줄이기 위해 요구되는 여러가지 음향요소의 전달함수를 제어하는 데 대한 불가능성으로 인해 능동 소음제어에 대한 실질적인 발전이 지연되 어 왔으나 최근 마이크로 컴퓨터를 비롯한 전자공학의 발전으로 인해 적응 신호처리 분야가 등장하게 되었으며, 음향계의 소음을 원하는 수준까지 제어 하는 능동 소음제어의 실시간 구현이 가능하게 되었다. 그 중에서도 음이 1 차원적으로 전파한다고 볼 수 있는 길이가 긴 덕트구조물에서의 능동 소음 제어는 가장 기본적이며 현실적으로 자동차 배기계나 냉동.공조설비에 있어 서 실용적으로 적용할 수 있는 문제임 만큼 많은 연구가 이루어지고 있다. 이러한 능동 소음제어 방법을 음향계에 적용하였을 때, 부가적인 음을 발생 하는 제어용 스피커로 인해 입력마이크로폰으로의 음향궤환이 존재하고 이 에 따라 제어계가 불안정해질 수 있으며, 또한 변환기의 사용으로 인한 부가 적인 전달함수가 존재하므로 이에 대한 중요한 의미를 갖고 고려하여야 한 다. 본 연구에서는 적응 필터링 이론에 의한 소음원의 입력신호에 대한 최적 한 예측으로써 부가음을 발생시키고, 입력신호 및 제어된 출력신호간의 차인 오차를 최소화 시키도록 하는 오차적응제어법을 이용한 능동소음 제어 방법 을 제시하였다. 이와 아울러 제어계의 환경변화에 따른 파라메타의 변화에 적응적으로 응답이 가능해야 하는 적응 소음제어 시스템에서, 음향궤환과 함 께 필히 고려해야 하는 부가적인 전달함수의 영향을 고려한 능동 소음제어 에 대해 연구하였다. 경량화 추세에 따라 지반이나 케이싱이 경량이거나 유연하여 회전축과 동적으로 연성된 경우 회전축-베어링-지반으로 이루어진 2중구조의 회전축 계 동특성을 해석할 수 있는 프로그램을 개발하므로서 회전 기계류의 진동 전반에 걸친 문제점에 대한 그 원인과 현상을 명확히 분석하여 국내의 전기 계류의 보다 신뢰성있는 설계 및 제작자료를 확보하는데 기여할 수 있게 하 였다.존의 small molecular Gd-chelate에 비해 매우 큼을 알 수 있었다. MnPC는 간세포에 흡수된 후 담도계로 배출되는 간특이성 조영제임을 확인하였다. 장비 내에서 반복 시행한 평균값의 차이는 대체적으로 유의한 차이가 없었으나, 다른 장비에서 반복 시행한 장비간의 사이에는 유의한 차이가 있는 경우가 더 많았다. 따라서 , MRS 검사를 소뇌나 뇌교의 어떤 절환에 적용하기 전에 각 장비 마다 정상 기준치를 반드시 얻은 후에 이상여부를 판 정하는 것이 필수적이라고 생각된다.EX> 이상이 적절한 진단기준으로 생각되었다. $0.4{\;}\textrm{cm}^3$ 이상의 좌우 부피차를 보이는 모든 증례에서 육안적으로도 해마위축이 뚜렷이 나타났다. 결론 : MR영상을 이용한 해마의 부피측정은 해마경화증 환자의 진단에 있어 육안적인 MR 진단이 어려운 제한된 경우에만 실제적 도움을 줄 수 있는 보조적인 방법으로 생각된다.ofile whereas relaxivity at high field is not affected by τS. On the other hand, the change in τV does not affect low field profile but strongly in fluences on both inflection fie이 and the maximum relaxivity value. The results shows a fluences on both inflection field

  • PDF

Gaussian Kernel Smoothing of Explicit Transient Responses for Drop-Impact Analysis (낙하 충격 해석을 위한 명시법 과도응답의 가우스커널 평활화 기법)

  • Park, Moon-Shik;Kang, Bong-Soo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.3
    • /
    • pp.289-297
    • /
    • 2011
  • The explicit finite element method is an essential tool for solving large problems with severe nonlinear characteristics, but its results can be difficult to interpret. In particular, it can be impossible to evaluate its acceleration responses because of severe discontinuity, extreme noise or aliasing. We suggest a new post-processing method for transient responses and their response spectra. We propose smoothing methods using a Gaussian kernel without in depth knowledge of the complex frequency characteristics; such methods are successfully used in the filtering of digital signals. This smoothing can be done by measuring the velocity results and monitoring the response spectra. Gaussian kernel smoothing gives a better smoothness and representation of the peak values than other approaches do. The floor response spectra can be derived using smoothed accelerations for the design.

Threshold Selection Method for Capacity Optimization of the Digital Watermark Insertion (디지털 워터마크의 삽입용량 최적화를 위한 임계값 선택방법)

  • Lee, Kang-Seung;Park, Ki-Bum
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.10 no.1
    • /
    • pp.49-59
    • /
    • 2009
  • In this paper a watermarking algorithm is proposed to optimize the capacity of the digital watermark insertion in an experimental threshold using the characteristics of human visual system(HVS), adaptive scale factors, and weight functions based on discrete wavelet transform. After the original image is decomposed by a 3-level discrete wavelet transform, the watermarks for capacity optimization are inserted into all subbands except the baseband, by applying the important coefficients from the experimental threshold in the wavelet region. The adaptive scale factors and weight functions based on HVS are considered for the capacity optimization of the digital watermark insertion in order to enhance the robustness and invisibility. The watermarks are consisted of gaussian random sequences and detected by correlation. The experimental results showed that this algorithm can preserve a fine image quality against various attacks such as the JPEG lossy compression, noise addition, cropping, blurring, sharpening, linear and non-linear filtering, etc.

  • PDF