• Title/Summary/Keyword: 신호시스템

Search Result 9,960, Processing Time 0.051 seconds

A 10b 250MS/s $1.8mm^2$ 85mW 0.13um CMOS ADC Based on High-Accuracy Integrated Capacitors (높은 정확도를 가진 집적 커페시터 기반의 10비트 250MS/s $1.8mm^2$ 85mW 0.13un CMOS A/D 변환기)

  • Sa, Doo-Hwan;Choi, Hee-Cheol;Kim, Young-Lok;Lee, Seung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.11 s.353
    • /
    • pp.58-68
    • /
    • 2006
  • This work proposes a 10b 250MS/s $1.8mm^2$ 85mW 0.13um CMOS A/D Converter (ADC) for high-performance integrated systems such as next-generation DTV and WLAN simultaneously requiring low voltage, low power, and small area at high speed. The proposed 3-stage pipeline ADC minimizes chip area and power dissipation at the target resolution and sampling rate. The input SHA maintains 10b resolution with either gate-bootstrapped sampling switches or nominal CMOS sampling switches. The SHA and two MDACs based on a conventional 2-stage amplifier employ optimized trans-conductance ratios of two amplifier stages to achieve the required DC gain, bandwidth, and phase margin. The proposed signal insensitive 3-D fully symmetric capacitor layout reduces the device mismatch of two MDACs. The low-noise on-chip current and voltage references can choose optional off-chip voltage references. The prototype ADC is implemented in a 0.13um 1P8M CMOS process. The measured DNL and INL are within 0.24LSB and 0.35LSB while the ADC shows a maximum SNDR of 54dB and 48dB and a maximum SFDR of 67dB and 61dB at 200MS/s and 250MS/s, respectively. The ADC with an active die area of $1.8mm^2$ consumes 85mW at 250MS/s at a 1.2V supply.

Study of Variation of Internal Taget Volume between 4DCT and Slow-CT in Respiratory Patterns Using Respiratory Motion Phantom (호흡 동조 구동 팬톰을 이용한 호흡패턴에 따른 4DCT, Slow-CT의 내부표적체적 변화 연구)

  • Lee, Soon Sung;Choi, Sang Hyoun;Min, Chul Kee;Ji, Young Hoon;Kim, Mi-Sook;Yoo, Hyoung Jun;Kim, Chan Hyeong;Kim, Kum Bae
    • Progress in Medical Physics
    • /
    • v.25 no.1
    • /
    • pp.53-63
    • /
    • 2014
  • The objective of this study is to investigate the difference of ITV lengths and ITVs between 4DCT and Slow-CT images according to respiratory patterns using a respiratory motion phantom. The respiratory periods 1~4 s and target motion 1~3 cm were applied on each respiratory pattern. 4DCT and Slow-CT images were acquired for 3 times. 4DCT and Slow-CT ITVs were measured with contouring the target in the Eclipse RTP system. The measured ITV lenghts and ITVs in 4DCT and Slow-CT images were compared to the known values. For the ITV lengths and ITVs in the 4DCT, the difference of them were reduced as the respiratory period is longer and target motion is shorter. For the Slow-CT, there was same tendency with change in 4DCT ITV lengths and ITVs about target motion. However, the difference of ITV lengths and ITVs for the respiratory periods were the lowest in respiratory period 1 second and different slightly within respiratory period 2-4 seconds. According to the respiratory patterns, pattern A had the highest reproducibility. Pattern B, C and D were showed the difference similar to each other. However, for pattern E, the reproducibility was the lowest compared with other four patterns. The difference of ITV lengths and ITVs between Slow-CT and 4DCT was increased by increasing the respiratory periods and target motion for all respiratory patterns. When the difference of Slow-CT ITV lengths and ITVs were compared with that of 4DCT ITV lengths and ITVs, Slow-CT ITV lengths and ITVs were approximately 22 % smaller than 4DCT, and the representations of target were different in each pattern. In case of pattern A, B and C, length difference was 3 mm at S (superior) and I (inferior) direction, and the length difference of pattern D was 1.45 cm at only "I" direction whereas the length difference of pattern E was 5 mm longer in "S" direction than "I" direction. Therefore, the margin in SI directions should be determined by considering the respiratory patterns when the margin of Slow-CT is compensated for 4DCT ITV lengths. Afterward, we think that the result of this study will be useful to analyze the ITV lengths and ITVs from the CT images on the basis of the patient respiratory signals.

Assessment of the Hydration Effect on In Vitro Human Skin by $^1H$ MRS at 14.1T System (고자장 14.1 T MRI/MRS 시스템에서 양성자 자기공명분광법을 이용한 생체 외 인체피부 보습효과에 대한 연구)

  • Choi Chi-Bong;Hong Sung-Tak;Woo Dong-Chul;Yoon Seong-Ik;Yoon Moon-Hyun;Cho Ji-Hyun;Lee Chul-Hyun;Cheong Chae-Joon;Park Sang-Yong;Oh Chil-Hwan;Choe Bo-Young
    • Progress in Medical Physics
    • /
    • v.17 no.2
    • /
    • pp.83-88
    • /
    • 2006
  • Purpose: We Investigated to achieve high resolution magnetic resonance (MR) Imaging and spectra of human skin in vitro with using a 14.1 T MRI/MRS system, and to evaluate the hydration effect of a moisturizer by measuring the skin's water concentration. Materials and Methods: We used the Brukrer 14.1 T MRI/MRS system with a vertical standard bore that was equipped with a DMX spectrometer gradient system (200 G/cm at a maximum 40 A), RF resonators (2, 5 and 10 mm) and Para Vision software. Spin echo and fast spin echo pulse sequences were employed for obtaining the high resolution MR images. The 3D-localized point resolved spectroscopy (PRESS) method was used to acquire the MR spectra. Results: The high resolution MR images and spectra of human skin in vitro were successfully obtained on a 14.IT system. The water concentration of human skin after applying a moisturizer was higher than that before applying a moisturizer. Conclusions: The present study demonstrated that the high-resolution MR images and spectra of human skin from a high field MRS instrument could be applicable to evaluating the hydration state of the stratum corneum.

  • PDF

Analyzing Heart Rate Variability for Automatic Sleep Stage Classification (수면단계 자동분류를 위한 심박동변이도 분석)

  • 김원식;김교헌;박세진;신재우;윤영로
    • Science of Emotion and Sensibility
    • /
    • v.6 no.4
    • /
    • pp.9-14
    • /
    • 2003
  • Sleep stages have been useful indicator to check a person's comfortableness in a sleep, But the traditional method of scoring sleep stages with polysomnography based on the integrated analysis of the electroencephalogram(EEG), electrooculogram(EOG), electrocardiogram(ECG), and electromyogram(EMG) is too restrictive to take a comfortable sleep for the participants, While the sympathetic nervous system is predominant during a wakefulness, the parasympathetic nervous system is more active during a sleep, Cardiovascular function is controlled by this autonomic nervous system, So, we have interpreted the heart rate variability(HRV) among sleep stages to find a simple method of classifying sleep stages, Six healthy male college students participated, and 12 night sleeps were recorded in this research, Sleep stages based on the "Standard scoring system for sleep stage" were automatically classified with polysomnograph by measuring EEG, EOG, ECG, and EMG(chin and leg) for the six participants during sleeping, To extract only the ECG signals from the polysomnograph and to interpret the HRV, a Sleep Data Acquisition/Analysis System was devised in this research, The power spectrum of HRV was divided into three ranges; low frequency(LF), medium frequency(MF), and high frequency(HF), It showed that, the LF/HF ratio of the Stage W(Wakefulness) was 325% higher than that of the Stage 2(p<.05), 628% higher than that of the Stage 3(p<.001), and 800% higher than that of the Stage 4(p<.001), Moreover, this ratio of the Stage 4 was 427% lower than that of the Stage REM (rapid eye movement) (p<.05) and 418% lower than that of the Stage l(p<.05), respectively, It was observed that the LF/HF ratio decreased monotonously as the sleep stage changes from the Stage W, Stage REM, Stage 1, Stage 2, Stage 3, to Stage 4, While the difference of the MF/(LF+HF) ratio among sleep Stages was not significant, it was higher in the Stage REM and Stage 3 than that of in the other sleep stages in view of descriptive statistic analysis for the sample group.

  • PDF

Imaging of Herpes Simplex Virus Type 1 Thymidine Kinase Gene Expression with Radiolabeled 5-(2-iodovinyl)-2'-deoxyuridine (IVDU) in liver by Hydrodynamic-based Procedure (Hydrodynamic-based Procedure를 이용한 간에서의 HSV1-tk 발현 확인을 위한 방사표지 5-(2-iodovinyl)-2'-deoxyuridine (IVDU)의 영상연구)

  • Song, In-Ho;Lee, Tae-Sup;Kang, Joo-Hyun;Lee, Yong-Jin;Kim, Kwang-Il;An, Gwang-Il;Chung, Wee-Sup;Cheon, Gi-Jeong;Choi, Chang-Woon;Lim, Sang-Moo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.5
    • /
    • pp.468-477
    • /
    • 2009
  • Purpose: Hydrodynamic-based procedure is a simple and effective gene delivery method to lead a high gene expression in liver tissue. Non-invasive imaging reporter gene system has been used widely with herpes simplex virus type 1 thymidine kinase (HSV1-tk) and its various substrates. In the present study, we investigated to image the expression of HSV1-tk gene with 5-(2-iodovinyD-2'-deoxyuridine (IVDU) in mouse liver by the hydrodynamicbased procedure. Materials and Methods: HSV1-tk or enhanced green fluorescence protein (EGFP) encoded plasmid DNA was transferred into the mouse liver by hydrodynaminc injection. At 24 h post-injection, RT-PCR, biodistribution, fluorescence imaging, nuclear imaging and digital wholebody autoradiography (DWBA) were performed to confirm transferred gene expression. Results: In RT-PCR assay using mRNA from the mouse liver, specific bands of HSV1-tk and EGFP gene were observed in HSV1-tk and EGFP expressing plasmid injected mouse, respectively. Higher uptake of radiolabeled IVDU was exhibited in liver of HSV1-tk gene transferred mouse by biodistribution study. In fluorescence imaging, the liver showed specific fluorescence signal in EGFP gene transferred mouse. Gamma-camera image and DWBA results showed that radiolabeled IVDU was accumulated in the liver of HSV1-tk gene transferred mouse. Conclusion: In this study, hydrodynamic-based procedure was effective in liver-specific gene delivery and it could be quantified with molecular imaging methods. Therefore, co-expression of HSV1-tk reporter gene and target gene by hydrodynamic-based procedure is expected to be a useful method for the evaluation of the target gene expression level with radiolabeled IVDU.

Real-Time 3D Ultrasound Imaging Method Using a Cross Array Based on Synthetic Aperture Focusing: I. Spherical Wave Transmission Approach (합성구경 기반의 교차어레이를 이용한 실시간 3차원 초음파 영상화 기법 : I. 구형파 송신 방법)

  • 김강식;송태경
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.5
    • /
    • pp.391-401
    • /
    • 2004
  • 3D imaging systems using 2D phased arrays have a large number of active channels, compelling to use a very expensive and bulky beamforming hardware, and suffer from low volume rate because, in principle, at least one ultrasound transmit-receive event is necessary to construct each scanline. A high speed 3D imaging method using a cross array proposed previously to solve the above limitations can implement fast scanning and dynamic focusing in the lateral direction but suffer from low resolution except at the fixed transmit focusing along the elevational direction. To overcome these limitations, we propose a new real-time volumetric imaging method using a cross array based on the synthetic aperture technique. In the proposed method, ultrasound wave is transmitted successively using each elements of an 1D transmit array transducer, one at a time, which is placed along the elevational direction and for each firing, the returning pulse echoes are received using all elements of an 1D receive array transducer placed along the lateral direction. On receive, by employing the conventional dynamic focusing and synthetic aperture method along lateral and elevational directions, respectively, ultrasound waves can be focused effectively at all imaging points. In addition, in the proposed method, a volume of interest consisting of any required number of slice images, can be constructed with the same number of transmit-receive steps as the total number of transmit array elements. Computer simulation results show that the proposed method can provide the same and greatly improved resolutions in the lateral and elevational directions, respectively, compared with the 3D imaging method using a cross array based on the conventional fixed focusing. In the accompanying paper, we will also propose a new real-time 3D imaging method using a cross array for improving transmit power and elevational spatial resolution, which uses linear wave fronts on transmit.

Changes in $A_{1}$, Adenosine Receptor-Adenylyl Cyclase System of Rat Adipocytes Fellowing Induction of Experimental Diabetes by Streptozotocin Treatment (Streptozotocin으로 당뇨병을 유발시킨 쥐의 지방세포에 나타나는 $A_{1}$, Adenosine Receptor-Adenylyl Cyclase System의 변화)

  • Park, Kyung-Sun;Lee, Myung-Soon;Kim, Kyung-Hwan
    • The Korean Journal of Pharmacology
    • /
    • v.29 no.1
    • /
    • pp.97-105
    • /
    • 1993
  • Adenosine receptors in rat adipose tissues have been reported to be of $A_{1}$ subclass, and their stimulation leads to inhibition of adenylyl cyclase, resulting in inhibition of lipolysis. In the present study we investigated changes in $A_{1}$ adenosine receptor-adenylyl cyclase system of adipocytes following induction of experimental diabetes in rats. One week following experimental diabetes were induced by intravenous injection of streptozotocin (50 mg/kg body wt.), adipocytes from rats $(170{\sim}230g)$ fed ad libitum were isolated using collagenase. When adipocytes were incubated for 1 h with 1 unit/ml adenosine deaminase and $1\;{\mu}M$ isoproterenol, and assayed for glycerol formation, it was found that the inhibition of lipolysis in diabetic adipocytes by $(-)-N^{6}-(R-phenylisopropyl)adenosine$ (PIA), an $A_{1}$, adenosine receptor agonist, was twice that of control adipocytes. In an effort to delineate the mechanism(s), $[^{3}H]PIA$ binding to adipocytic membranes from diabetic and control rats were determined. Neither the affinities nor numbers of $A_{1}$ adenosine receptor were significantly different from each other (Best fit parameters for the one-site model are: $K_{d}=0.51{\pm}0.09nM$ and $B_{max}=1.60{\pm}0.12\;pmoles/mg$ protein for control membranes; $K_{d}=0.54{\pm}0.21\;nM$ and $B_{max}=1.72{\pm}0.31\;pmoles/mg$ protein for diabetic membranes). However, the inhibiton by PIA of the isoproterenol-stimulated adenylyl cyclase activities was found to be 1.9 times higher in adipocytic membranes from diabetic rats than those from controls. These results suggest that the increased sensitivity of inhibition of lipolysis to PIA in adipocytic membranes from diabetic rats is due to changes in signal transduction pathways, rather than alterations of $A_{1}4 adenosine receptor molecules themselves.

  • PDF

Application of Borehole Radar to Tunnel Detection (시추공 레이다 탐사에 의한 지하 터널 탐지 적용성 연구)

  • Cho, Seong-Jun;Kim, Jung-Ho;Kim, Chang-Ryol;Son, Jeong-Sul;Sung, Nak-Hun
    • Geophysics and Geophysical Exploration
    • /
    • v.9 no.4
    • /
    • pp.279-290
    • /
    • 2006
  • The borehole radar methods used to tunnel detection are mainly classified into borehole radar reflection, directional antenna, crosshole scanning, and radar tomography methods. In this study, we have investigated the feasibility and limitation of each method to tunnel detection through case studies. In the borehole radar reflection data, there were much more clear diffraction signals of the upper wings than lower wings of the hyperbolas reflected from the tunnel, and their upper and lower wings were spreaded out to more than 10m higher and lower traces from the peaks of the hyperbolas. As the ratio of borehole diameter to antenna length increases, the ringing gets stronger on the data due to the increase in the impedance mismatching between antennas and water in the boreholes. It is also found that the reflection signals from the tunnel could be enhanced using the optimal offset distance between transmitter and receiver antennas. Nevertheless, the borehole radar reflection data could not provide directional information of the reflectors in the subsurface. Direction finding antenna system had a advantage to take a three dimensional location of a tunnel with only one borehole survey even though the cost is still very high and it required very high expertise. The data from crosshole scanning could be a good indicator for tunnel detection and it could give more reliable result when the borehole radar reflection survey is carried out together. The images of the subsurface also can be reconstructed using travel time tomography which could provide the physical property of the medium and would be effective for imaging the underground structure such as tunnels. Based on the results described above, we suggest a cost-effective field procedure for detection of a tunnel using borehole radar techniques; borehole radar reflection survey using dipole antenna can firstly be applied to pick up anomalous regions within the borehole, and crosshole scanning or reflection survey using directional antenna can then be applied only to the anomalous regions to detect the tunnel.

Microarray Analysis of Gene Expression in Rat Glioma after Ethanol Treatment (에탄올 처리에 의한 흰쥐 신경아교종(Glioma) 세포에서의 유전자 발현 - DNA 칩을 이용한 분석 -)

  • Lee, So Hee;Oh, Dong-Yul;Han, Jin-Hee;Choi, Ihn-Geun;Jeon, Yang-Whan;Lee, Joon-Noh;Lee, Tae Kyung;Jeong, Jong-Hyun;Jung, Kyung Hwa;Chai, Young-Gyu
    • Korean Journal of Biological Psychiatry
    • /
    • v.14 no.2
    • /
    • pp.115-121
    • /
    • 2007
  • Objetives : Identification of target genes for ethanol in neurons is important for understanding its molecular and cellular mechanism of action and the neuropathological changes seen in alcoholics. The purpose of this study is to identify of altered gene expression after acute treatmet of ethanol in rat gliom cells. Methods : We used high density cDNA microarray chip to measure the expression patterns of multiple genes in cultured rat glioma cells. DNA microarrays allow for the simultaneous measurement of the expression of several hundreds of genes. Results : After comparing hybridized signals between control and ethanol treated groups, we found that treatment with ethanol increased the expression of 15 genes and decreased the expression of 12 genes. Upregulated genes included Orthodenticle(Drosophila) homolog 1, procollagen type II, adenosine A2a receptor, GATA bindning protein 2. Downregulated genes included diacylglycerol kinase beta, PRKC, Protein phosphatase 1, clathrin-associated protein 17, nucleoporin p58, proteasome. Conclusion : The gene changes noted were those related to the regulation of transcription, signal transduction, second messenger systems. modulation of ischemic brain injury, and neurodengeneration. Although some of the genes were previously known to be ethanol responsive, we have for the most part identified novel genes involved in the brain response to ethanol.

  • PDF

Evaluation of Metabolic Abnormality in Brain Tumors by In Viuo $^1$H MR Spectroscopy at 3 Tesla (3T 양성자 자기공명분광에 의한 뇌종양의 대사물질 이상소견)

  • Choe, Bo-Young;Jeun, Sin-Soo;Kim, Bum-Soo;Lee, Jae-Mun;Chung, Sung-Taek;Ahn, Chang-Beom;Oh, Chang-Hyun;Kim, Sun I.;Lee, Hyoung-Koo
    • Progress in Medical Physics
    • /
    • v.13 no.3
    • /
    • pp.120-128
    • /
    • 2002
  • To investigate differences between the metabolic ratios of normal controls and brain tumors such as astrocytomas and glioblastoma multiforme (GM) by proton MR spectroscopy (MRS) at 37 high field system. Using 3T MRI/MRS system, localized water-suppressed single-voxel technique in patients with brain tumors was employed to evaluate spectra with peaks of N-acetyl aspartate (NAA), choline-containing compounds (Cho), creatine/phosphocreatine (Cr) and lactate. On the basis of Cr, these peak areas were quantificated as a relative ratio. The variation of metabolites measurements of the designated region in 10 normal volunteers was less than 10%. Normal ranges of NAA/Cr and Cho/Cr ratios were 1.67$\pm$018 and 1.16$\pm$0.15, respectively. NAA/Cr ratio of all tumor tissues was significantly lower than that of the normal tissues (P=0.005). Cho/Cr ratio of glioblastoma multiforme was significantly higher than that of astrocytomas (P=0.001). Lactate was observed in all tumor cases. The present study demonstrated that the neuronal degradation or loss was observed in all tumor tissues. Higher grade of brain tumors was correlated with higher Cho/Cr ratio, indicating a significant dependence of Cho levels on malignancy of gliomas. This results suggest that clinical proton MR spectroscopy could be useful to predict tumor malignancy.

  • PDF