• Title/Summary/Keyword: 신재생 에너지원

Search Result 705, Processing Time 0.041 seconds

A Study on Oxygen Evolution Activity of Co3O4 with different morphology prepared by Ultrasonic Spray Pyrolysis for Water Electrolysis (분무열분해로 합성한 수전해용 Co3O4의 입자형태에 따른 산소발생 활성에 관한 연구)

  • Kim, Ingyeom;Nah, In Wook;Park, Sehkyu
    • Korean Chemical Engineering Research
    • /
    • v.54 no.6
    • /
    • pp.854-862
    • /
    • 2016
  • As the demand for a clean energy to replace fossil fuel being depleted increases, hydrogen energy is considered as a promising candidate for future energy source. Water electrolysis which produces hydrogen has high energy efficiency and stability but still has a large overpotential for oxygen evolution reaction (OER). In this study, $Co_3O_4$ catalysts with different morphology were prepared by spray pyrolysis from solutions which contain Co precursor and various organic additives (urea, sucrose, and citric acid), followed by post heat treatment. For the catalysts synthesized, X-ray diffraction (XRD) measurements were performed to identify their crystal structure. Morphology and surface shape of the catalysts were observed by scanning electron microscopy (SEM) and transmission electron microscopy (TEM). Surface area and pore volume were examined by nitrogen adsortpion & desorption tests and X-ray photoelectron spectroscopy (XPS) was conducted to confirm nitrogen doping. Linear sweep voltammetry (LSV) was carried out to investigate OER activity of $Co_3O_4$ catalysts. As a result, bare-$Co_3O_4$ which has high surface area and small particle size determined by spray pyrolysis showed high activity toward OER.

Development of Anion Exchange Membrane based on Crosslinked Poly(2,6-dimethyl-1,4-phenylene oxide) for Alkaline Fuel Cell Application (화학적 가교를 이용한 Poly(2,6-dimethyl-1,4-phenylene oxde)계 음이온 교환막의 제조 및 알칼리 연료전지용 특성평가)

  • Sung, Seounghwa;Lee, Boryeon;Choi, Ook;Kim, Tae-Hyun
    • Membrane Journal
    • /
    • v.29 no.3
    • /
    • pp.173-182
    • /
    • 2019
  • Much research has been made for finding new and eco-friendly alternative sources of energy to solve the problems related with the pollution caused by emissions of greenhouse gases such as carbon dioxide as the use of fossil fuels increases worldwide. Among them, fuel cells draws particular interests as an eco-friendly energy generator because only water is obtained as a by-product. Anion exchange membrane-based alkaline fuel cell (AEMFC) that uses anion exchange membrane as an electrolyte is of increased interest recently because of its advantages in using low-cost metal catalyst unlike the PEMFC (potton exchange membrane fuel cell) due to the high-catalyst activity in alkaline conditions. The main properties required as an anion exchange membrane are high hydroxide conductivity and chemical stability at high pH. Recently we reported a chemically crosslinked poly(2-dimethyl-1,4-phenylene oxide) (PPO) by reacting PPO with N,N,N',N'-tetramethyl-1,6-hexanediamine as novel anion exchange membranes. In the current work, we further developed the same crosslinked polymer but having enhanced physicochemical properties, including higher conductivity, increased mechanical and dimensional stabilities by using the PPO with a higher molecular weight and also by increasing the crosslinking density. The obtained polymer membrane also showed a good cell performance.

A study on a power plant using Dye-sensitized solar cells in low light environments (저조도 환경에서의 염료감응형 태양전지를 활용한 발전소자에 관한 연구)

  • Kim, Sun-Geum;Baek, Sung-June
    • Journal of IKEEE
    • /
    • v.25 no.2
    • /
    • pp.267-272
    • /
    • 2021
  • Recently, attention has been focused on renewable energy and carbon neutrality to resolve fossil energy depletion and environmental problems. In addition, high-rise urban buildings and an increase in building energy are rapidly increasing. There are many restrictions on installing solar power in urban areas. In addition, as buildings become taller, a lot of low-light environments in which shade is formed occur. Therefore, in this study, we intend to develop a power plant capable of generating electric power in an outdoor low-light environment and indoor lighting environment. The power plant in a low-light environment used a dye-sensitized solar cell. A unit cell and a 20cm×20cm module were manufactured, and the electrical characteristics of the power plant were measured using light sources of LED, halogen lamp, and 3-wavelength lamp. The photoelectric conversion efficiency of the unit cell was 17.2%, 1.28%, 19,2% for each LED, halogen lamp, and 3-wavelength lamp, and the photoelectric conversion efficiency of the 20cm×20cm module was 10.9%, 8.7%, and 11.8%, respectively. In addition, the maximum power value of the module was 13.1mW, 15.7 mW, and 14.2 mW for each light source, respectively, confirming the possibility of power generation in a low-light environment

Design of Suitable a New Active Clamp Sepic-Flyback Converter for a Fuel Cell Generation System (연료전지 발전시스템에 적합한 새로운 능동 클램프 Sepic-Flyback 컨버터의 개발)

  • Lee, T.W.;Jang, S.J.;Kim, S.S.;Lee, B.K.;Kim, H.S.;Won, C.Y.
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.3
    • /
    • pp.258-265
    • /
    • 2006
  • In this paper, an active clamping sepic-flyback converter has been proposed, which is suitable for a fuel cell based power generation system. The proposed converter is superposition of sepic converter mode and flyback mode. It has outstanding high boosting output voltage, component utilization and high efficiency characteristics under the inherently severe low output voltage of the fuel cell generator. In this paper, the validity of the proposed converter has been verified by the informative simulation and experimental results that make used of the PEMFC.

Design and Implementation of KPX's next control center (전력거래소 차기 계통운영시스템 설계에 관한 연구)

  • Choi, Young-Min;Park, Min-Ryung;Lee, Jin-Su;Lee, Gun-Woong
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.380-381
    • /
    • 2011
  • 전력거래소는 2014년 나주본사이전 이후 1억kW 대용량 전력계통을 운영하기 위한 차기 계통운영시스템(이하 차기EMS) 구축을 계획하고 있다. EMS(Energy Management System)는 전국의 발, 변전소에서 계통정보를 실시간으로 취득하여 전력계통을 감시하며, 연료비 기반의 최적 경제점을 찾아 발전기를 제어하고, 전력계통을 수식화한 상태추정 결과를 기반으로 상정사고분석, 고장전류계산 등 전력계통운영을 위한 종합시스템이다. 국내 EMS의 역사는 1979년 미국의 L&N 시스템 도입을 시작으로 1988년 일본의 Toshiba EMS, 2001년 Alstom사의 NEMS를 구축하여 현재 운영중에 있다. 하지만, 외산 제품 도입에 따른 기술이전, 유지보수의 어려움을 타개하기 위해 2004년 한국형 EMS(이하 K-EMS) 연구개발계획을 수립하고 전력거래소를 주축으로 한 산학연을 구성하여 2010년 K-EMS 개발을 성공적으로 완료하였다. 차기 EMS는 국내 기술력으로 개발된 정부연구과제 성과물인 K-EMS를 기반으로 구축이 이루어지며, 총 3년간의 개발 및 시험과정을 거쳐 실계통운영을 담당할 예정이다. 차기EMS가 설치되어 운영예정인 급전소는 전력수급 균형유지와 발전소 운영 총괄 지휘 및 765kV, 345kV 송전망 운영역할을 담당할 나주급전소와 154kV 비수도권 송전망 운영을 담당할 천안급전소, 154kV 수도권 송전망 운영을 책임질 서울급전소 이상 3곳이다. 차기EMS는 발전 및 송, 변전 설비의 대형화, 다양한 FACTS 설비, 신재생에너지원으로 대표되는 분산전원의 등장과 같은 급변하는 전력계통 변화에 능동적인 역할을 성공적으로 수행할 것으로 기대하고 있다.

  • PDF

Maintenance-Effectiveness Analysis of Photovoltaic Equipment for Detached Houses (주택용 태양광발전설비의 유지관리 효과 분석)

  • Park, Byeong-Hun;Choi, Jong-Won;Kim, Jae-Yeob
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.4
    • /
    • pp.359-365
    • /
    • 2016
  • With the government's support using new and renewable energy, photovoltaic equipment has been rapidly supplied. However, compared to supply rate, maintenance has not supported enough and relevant research has not much conducted. Even though large power plant facilities have been maintained well, small equipment for detached houses has been rarely maintained. Therefore, the purpose of this study is to analyze maintenance effectiveness of photovoltaic equipment for detached houses. It was analyzed that photovoltaic equipments were merely maintained. What is the most important in maintenance effectiveness is increase of power generation. It was estimated that if photovoltaic equipment for detached houses is maintained well, power generation increases by 6.5% at least. That produces the same effect as the additional supply of photovoltaic equipment to 9,700 households. As a result, it is necessary to maximize the effectiveness of the government's budget investment through well maintenance of photovoltaic equipments.

Correlation Analysis between the Renewable Energy Source Generation and the Utilization for Smart Grid in Korea (한국의 스마트 그리드를 위한 신재생에너지원 생산과 활용률 간의 상관관계 분석)

  • Hyun, Jung Suk;Park, Chan Jung;Lee, Junghoon;Park, Kyung Leen
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.2
    • /
    • pp.347-353
    • /
    • 2017
  • In order to prohibit global warming, various kinds of regulatory policies have been established in the whole world. One example is the establishment of the Renewable Portfolio Standard. It requires the increased portion in energy production from renewable energy sources. The Republic of Korea adopted the act on the promotion of the development, use, and diffusion of new and renewable energy since 2012. However, in spite of the effort on the consideration of the renewable energy sources, it was reported the carbon intensity of electricity in Korea was not that low in 2015. Thus, it is required to examine the recent state of the utilization degree of the renewable energy sources in Korea. This paper analyzed the statistical data provided by Korea Power Exchange (KPX) to examine any problems and solutions for generating electricity from the renewable energy sources. We focused on the generation capacity provided by the power plants participated in the market, the electric power trading amount, and the utilization coefficient for 10 years. By analyzing the data, we provide an alternative to solve some imbalance among the factors contributing to renewable energy use.

Feasibility Study of small hydropower at a municipal wastewater treatment plant by model analysis (모델분석을 통한 하수처리장 소수력발전 경제성 평가)

  • Kim, Won-Kyoung;Kim, Dong-Soo;Kang, Ji-Hoon;Chae, Kyu-Jung;Kim, Jung-Yeon;Lee, Chul-Hyung;Park, Wan-Soon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.216-220
    • /
    • 2012
  • 본 연구는 경기도 용인시에 위치한 공공하수처리장을 대상으로 소수력발전 성능특성을 예측하고 경제성을 분석하여 소수력발전소의 건설타당성을 제시하였다. 방류구에서의 수준측량 조사에 따르면 실제 유효 낙차는 4.3m로 나타났다. 최근 5년간 방류량 자료를 살펴보면 일평균 실제 처리량은 약 $30,000m^3/day$로 나타났으며, 우수 유입과 물 사용량이 증가하는 여름 및 가을에 처리량이 증가하였다. 설계유량은 유량변화에 따른 누적 확률밀도와 유량지속곡선에 근거해 산정하였으며, 시간빈도로 보았을 때 17%의 유량이 지속되는 $0.35m^3/sec$가 설계유량으로 나타났다. 예상되는 수차 발전용량은 11kW급이며, 시스템 가동율은 74%, 그리고 계통선에 송출될 수 있는 연 전력생산량은 71.3MWh로 나타났다. 경제성 평가는 신재생에너지 경제성 분석 도구인 RETScreen 프로그램을 사용하여 B/C ratio, IRR, 개발투자비 등의 경제성 평가지표들을 산정하였다. 편익(Benefit) 산정시 전력기준단가는 133.67원/kWh, 할인율 7%를 적용하였으며, 비용(Cost) 산정시 유지관리비는 초기 건설비의 1%, 사용연한 30년을 적용하였다. 경제성 분석결과 기흥레스피아의 소수력발전소 건설시 초기 건설공사비가 $165,000 일 때, B/C 1.0, NPV $3,534, 투자회수기간 15.1년으로 산정되었고 따라서 초기 건설비용이 $165,000 이하일 때 가장 경제적인 것으로 파악되었다.

  • PDF

Identification of Strategic Fields for Developing Smart City in Busan Using Text Mining (텍스트 마이닝을 이용한 스마트 도시계획 수립을 위한 전략분야 도출연구: 부산 사례를 바탕으로)

  • Chae, Yoonsik;Lee, Sanghoon
    • Journal of Digital Convergence
    • /
    • v.16 no.11
    • /
    • pp.1-15
    • /
    • 2018
  • The purpose of this study is to analyze bibliographic information of Busan and other cities' reports for urban development initiative and identify the strategic fields for future smart city plan. Text mining method is used in this study to extract keywords and identify the characteristics and patterns of information in urban development reports. As a result, in earlier stage, Busan city focused on service creation for industrial development but there are lack of discussions on the linkage of information systems with ICT technology. However, recent urban planning in Busan contained various contents related to integrated connections of infrastructure, ICT system, and operation management of city in the specific fields of traffic, tourism, welfare, port/logistics, culture/MICE. This results of study is expected to provide policy implications for planning the future urban initiatives of smart city development.

A Study on the Structural System and Implementation of Cantilever Actuator System (외팔보 엑츄에이터 시스템 구조 및 구현에 관한 연구)

  • Yoon, Keun-Young;Baek, Soo-Whang
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.4
    • /
    • pp.651-656
    • /
    • 2019
  • This paper is a study on the structure system and implementation of cantilever actuator for decontamination. There are many kinds of exterior materials that attach to the exterior walls of a building. Glass, in particular, can be contaminated in a short period of time due to external exposure. The pollutants like this damage the appearance of a building. It can also cause health problems for users, and dust attached to solar panels creates problems that greatly reduce the power generation of solar panels. In order to remove such contaminants, professional workers usually remove contaminants attached to the outer walls. However, even with stability, accidents are often caused by a number of unexpected variables that occur in the field. Thus, to overcome these shortcomings, the cantilever actuator structure system was proposed. The system was designed through research. Then, we made a cantilever actuator and checked its operability. Finally, the effectiveness of the cantilever actuator was reviewed.