• Title/Summary/Keyword: 신성한 물

Search Result 202, Processing Time 0.028 seconds

Spatial variability of heavy metal contamination of urban roadside sediments collected from gully pots in Seoul City (서울시 우수관에서 채취한 도로변 퇴적물의 중금속오염의 공간적 변화)

  • 이평구;유연희;윤성택;신성천
    • Journal of Soil and Groundwater Environment
    • /
    • v.8 no.2
    • /
    • pp.19-35
    • /
    • 2003
  • In order 새 investigate the spatial and seasonal variations of heavy metal pollution in heavily industrialized urban area, urban roadside sediments were collected for five years from gully pots in Seoul City. A series of studies have been carried out concerning the physicochemical characteristics of the sediments in order to evaluate the contamination of heavy metals such as Cd, Co, Cr, Cu, Ni, Pb and Zn. Roadside sediments and uncontaminated stream sediments were analyzed for total metal concentrations using acid extraction. The roadside sediments are characterized by very high concentrations of Zn (2,665.0$\pm$1,815.0 $\mu\textrm{g}$/g), Cu (445.6$\pm$708.0 $\mu\textrm{g}$/g), Pb (214.3$\pm$147.9 $\mu\textrm{g}$/g) and Cr (182.1$\pm$268.8 $\mu\textrm{g}$/g), indicating an artificial accumulation of these metals to the sediment chemistry. Comparing with average contents of uncontaminated stream sediments, roadside sediments were shown zinc 14 times (up to 64.4), copper 9 times (up to 181.7), lead 6 times (up to 63.7), cobalt 6 times (up to 168.7), nickel 4 times (up to 98.4), cadmium 2 times (up to 12.8) and chrome 2 times (up to 40.2) high content. The relative degree of heavy metal pollution for roadside sediments collected from each district in Seoul City is evaluated using the “geoaccumulation index”. As a result, heavy-metal contamination is highest centering the oldest residential district and industry area, and contamination level decreases as go to outer block of the city. The factor analysis results indicate that the levels of Cu, Ni, Fe and Cr are strongly related to numbers of factories, whereas the concentrations of Cr, Zn and Cd dependant on pollution index, indicating artificial contamination due to site-specific traffic density.

Confinement Effects of High Strength Reinforced Concrete Tied Columns (고강도 철근콘크리트 띠철근 기둥의 구속효과)

  • 신성우;한범석
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.4
    • /
    • pp.578-588
    • /
    • 2002
  • An experimental study was conducted to investigate the effectiveness of transverse reinforcement in reinforced concrete tied columns subjected to monotonically increasing axial compression. Eighteen large-scale columns(260$\times$260$\times$1200 mm) were tested. Effects of main variables such as the concrete compressive strength, the tie configuration, the transverse reinforcement ratio, the tie spacing, and the spatting of the concrete cover were considered. High-strength concrete columns under concentric axial loads show extremely brittle behavior unless the columns are confined with transverse reinforcement that can provide sufficiently high lateral confinement pressure There is a consistent decrease in deformability of column specimen with increasing concrete strength. Test results were compared with the previous confinement model such as modified Kent-Park, Sheikh-Uzumeri, Mander, and Saatcioglu-Razvi model. The comparison indicates that many previous models for confined concrete overestimate or underestimate the ductility of confined concrete.

An Evaluation on Punching Shear Capacity of R/C Flat Plate Slab (RC 플랫 플레이트 슬래브의 뚫림전단성능평가)

  • Kim, Jong-Keun;Shin, Sung-Woo;Yang, Ji-Soo;Lee, Li-Hyung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.7 no.3
    • /
    • pp.205-213
    • /
    • 2003
  • The primary purpose of this study is to investigate punching shear capacity of flat plate slab using high strength concrete in column. It may be much contributed to economy efficiency and structural advantages that High Strength Concrete(HSC) used for vertical member and Normal Strength Concrete(NSC) for horizontal member. Therefore, six plate flat slab specimens with HSC column and NSC slab had been made and tested with real scale. The major variables were compressive strength of concrete(fck=285, $460kgf/cm^2$), extended length of HSC from column face and amount of shear reinforcements. As the result of this test, the maximum load and punching shear capacity of specimens is affected by extended length and shear reinforcements.

Performance Comparison of Traffic-Dependent Displacement Estimation Model of Gwangan Bridge by Improvement Technique (개선 기법에 따른 광안대교의 교통량 의존 변위 추정 모델 성능 비교)

  • Kim, Soo-Yong;Shin, Sung-Woo;Park, Ji-Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.4
    • /
    • pp.120-130
    • /
    • 2019
  • In this study, based on the correlation between traffic volume data and vertical displacement data developed in previous research using the bridge maintenance big data of 2006, the vertical displacement estimation model using the traffic volume data of Gwangan Bridge for 10 years A comparison of the performance of the developed model with the current applicability is presented. The present applicability of the developed model is analyzed that the estimated displacement is similar to the actual displacement and that the displacement estimation performance of the model based on the structured regression analysis and the principal component analysis is not significantly different from each other. In conclusion, the vertical displacement estimation model using the traffic volume data developed by this study can be effectively used for the analysis of the behavior according to the traffic load of Gwangan Bridge.

An Experimental Study of Spalling Characteristics of High-Strength Reinforced Concrete Columns with PP Fibers (PP 섬유를 함유한 고강도 철근콘크리트 기둥의 폭열 특성에 관한 실험적 연구)

  • Sin, Sung-Woo;Yu, Suk-Hyeong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.2
    • /
    • pp.83-90
    • /
    • 2006
  • A spalling is defined as the damages of concrete exposed to high temperature during the fire by causing cracks and localized bursting of small pieces of concrete. It is reported that spalling is caused by the vapor pressure and polypropylene(PP) fiber has an important role in protecting from spalling. The characteristics of fire resistance of high-strength reinforced concrete columns with various concrete strength and various contents of PP fiber were investigated in this study. In results, the ratio of unstressed residual strength of columns increases as the concrete strength increases and the ratio of unstressed residual strength of columns exposed to fire decreases as the content of PP fiber increases from 0% to 0.2%.

A Study on the Properties of Concrete Substituting Copper Slag for Fine Aggregate (잔골재를 동슬래그로 대체한 콘크리트의 특성 연구)

  • Bae, Ju Seong;Kim, Nam Wook;Ko, Sang Hun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.3
    • /
    • pp.151-158
    • /
    • 2007
  • The recent government policy for environment is pursuing for a circular waste control system not only to reduce waste as much as possible but also to vigorously use the already produced waste. Copper slag has a higher fineness modulus and a greater specific gravity than natural aggregate. but when the substitutive ratio of fine aggregate is higher than 30%, material segregation occurs by bleeding. Thus, in this study, the strength and the physical properties were tested for the specimens manufactured by varying the types of admixtures, and the substitutive ratio of copper slag to suppress material segregation occurring due to the bleeding of concrete using copper slag as the substitutive material of fine aggregate and to find the adequate substitutive ratio of copper slag.

Influence of Column Aspect Ratio on the Punching Shear Strength of Flat Plate Slab-Column Edge Connections (플랫 플레이트 슬래브-외부기둥 접합부의 뚫림전단강도에 대한 기둥 형상비의 영향)

  • Shin, Sung-Woo;Choi, Myung-Shin;Kim, Cheol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.1
    • /
    • pp.121-129
    • /
    • 2007
  • The aim of this study is to investigate punching shear strength of exterior connections in the flat plate structure with rectangular column. To inspect the effect of column aspect ratios on the punching shear behavior, eight specimens for exterior connection were made and tested. In this experimental program the length of critical perimeter was kept constant, while column aspect ratio varied from 2.0 to 4.5. Two levels of concrete strength and slab reinforcement ratio were also considered. As the column aspect ratio increased, the punching shear strengths are decreased. The decrement of punching shear strength was small in specimens with high aspect ratio of column.

Estimation of Optimum PP Fiber Content for the Spalling Control of High Strength Reinforced Concrete Columns (고강도 철근콘크리트 기둥의 폭열제어를 위한 최적의 PP섬유함유량 산정)

  • Kim, In Ki;Yoo, Suk Hyeong;Shin, Sung Woo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.2
    • /
    • pp.155-163
    • /
    • 2007
  • High Strength Concrete (HSC) has weakness that in a fire, it is spalled and brittles. The phenomenon of spalling is made by water vapor's (resulting from evaporation in the material at over $100{^{\circ}C}$)' being confined in watertight concrete. As the concrete strength increases, the degree of damage caused by the spalling becomes more serious because of the permeability. It is reported that the polypropylene(PP) fiber has an important role in protecting concrete from spalling and the optimum dosage of PP fiber is 0.2%. This study was conducted on the nonreinforced concrete specimens. The high-temperature behavior of high-strength reinforced concrete columns with various concrete strength and various dosage of PP fibers was investigated in this study. The results show that the ratio of unstressed residual strength of columns increases as the concrete strength increases and the ratio of unstressed residual strength of columns increases as the dosage of PP fiber increases from 0% to 0.2%, however, the effect of fiber dosage on residual strength of column barely changes above 0.2%.

Induction of Apoptosis in Human Cancer Cells with Extracts of Taraxacum coreanum, Youngia sonchifolia and Ixeris dentate (흰민들레, 고들빼기, 씀바귀 추출물의 암세포 증식 억제 효과)

  • Shin, Seong-Ah;Lee, Hae-Nim;Choo, Gang-Sik;Kim, Hyeong-Jin;Park, Byung-Kwon;Kim, Byeong-Soo;Jung, Ji-Youn
    • Journal of Food Hygiene and Safety
    • /
    • v.31 no.1
    • /
    • pp.51-58
    • /
    • 2016
  • This research examined the effects of Compositae extract on the inhibition of proliferation and apoptosis in human breast and human gastric cancer cells. Compositae extracts which is used in the experiment are Taraxacum coreanum (TC), Youngia sonchifolia (YS) and Ixeris dentata (ID). The proliferation of SK-BR-3, MDA-MB-231 and AGS cells were investigated by MTT assay. ID and YS extracts inhibited proliferation of SK-BR-3, MDA-MB-231 and AGS cells in a dose-dependent manner, but TC have barely affected. In addition, the most effective extract was ID. To assess the apoptosis of ID extract, the nuclei of human cancer cells were stained with DAPI solution respectively. Chromatin condensation, indicated apoptosis, was increased in a dose-dependent manner. We investigated change of ID extract-induced apoptosis proteins on human cancer cells by western blot analysis. The level of Bcl-2 decreased, whereas the level of Bax, cleaved-PARP increased in dose-dependent manner compared with non-treatment. Also Bax/Bcl-2 ratio, which is used in clinical indicator of apoptosis, was increased at ID extract treatment group compared with non-treatment. Moreover the Bax/Bcl-2 ratio of MDA-MB-231 cell was significantly increased as against SK-BR-3, AGS cells. These results indicated that ID extract have anti-proliferation effect better than YS or TC, and induced apoptosis in human breast cancer MDA-MB-231 cell better than human breast cancer SK-BR-3 cell, human gastric cancer. Even if further research is needed, ID can be developed as a chemopreventive or therapeutic agent of breast cancer.

Physical Modeling of Horizontal Force on the Inland Vertical Structure by Tsunami-like Waves (육상의 직립구조물에 미치는 지진 해일에 의한 수평 파력 및 파압에 대한 수리모형실험)

  • Park, Hyongsu;Cox, Daniel;Shin, Sungwon
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.29 no.6
    • /
    • pp.363-368
    • /
    • 2017
  • The tsunami flood the coastal cities and damage the land structures. The study on wave pressure and force on land structures is one of the important factors in designing the stability of inland structures. In this study, two - dimensional wave flume tests on the horizontal wave force and pressure of tsunamis on a simplified box-type structure was conducted. Vertical distribution and wave power of horizontal wave pressure over time were measured by pressure sensors and force transducer. Also, those were measured from the different wave breaking types. The vertical distribution of horizontal wave pressure was uniform at the moment when the horizontal wave force to the structure was maximum under the breaking wave condition. A surf similarity parameter was employed in order to figure out the relationship between the maximum horizontal wave force on the structure as a function of various incident wave conditions. As a result, the non - dimensionalized horizontal wave force tends to decrease exponentially as the surf similarity parameter increases.