• Title/Summary/Keyword: 신뢰성시험

Search Result 2,281, Processing Time 0.036 seconds

A Study on the Necessity of Verification about depot level maintenance plan through the Weapons System cases analysis (무기체계 사례 분석을 통한 창정비개발계획안 검증 필요성 연구)

  • Ahn, Jung-Jun;Kim, Su-Dong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.2
    • /
    • pp.76-82
    • /
    • 2019
  • This study has done to search for a solution to remove risk limitedly caused by separating weapon system acquisition from operation and maintenance at the view point of Logistic Commander who's responsible for stable operation and maintenance after acquiring weapon system. At the System development stage, unverified overhaul development plan may cause additional manpower and costs after the development, and furthermore it is likely to have risk to lower reliability of the military. Thus, research and development agency should write overhaul development plan at the System development stage, and it should be verified through evaluation and verification test. Secondly, during research and development, institutional supplementation is needed to calculate human and material resources writing overhaul development plan. Thirdly, it should be able to analyze proper operation & maintenance plan and cost for overhaul plan at the pre-investigation stage. Fourthly, the base which can develop overhaul concept and overhaul factors should be included in the need and need determination document. Lastly, for the weapon system which has small amount of high power figure, project management should be performed to be able to specify at the each acquisition level of weapon system to realize Article 28, clause 3 and 4 of Defense business law.

The History and Development of the Marine Environment QA/QC (Quality Assurance/Quality Control) Management System (해양환경 정도관리제도 운영에 대한 고찰)

  • PARK, MI-OK;PARK, JUN-KUN;KIM, SEONG-GIL;KIM, SEONG-SOO
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.26 no.3
    • /
    • pp.185-200
    • /
    • 2021
  • The Marine Environment QA/QC management system has been operated since 2010 to secure the reliability of data and improve the analysis capabilities of measurement and analysis institutions. From 2010 to 2020, the cumulative number of measurement and analysis institutions participated in the QA/QC management system was 266. And the number of certificates issued by the ministry of oceans and fisheries is 182. A total of 32 reference materials for proficiency testing and interlaboratory comparisons have been developed. They were first developed focusing on items (Nutrients, COD) commonly analyzed in marine environmental measuring network, marine pollution impact surveys, sea area utilization impact assessment, deepsea water surveys, and information network on fishing ground environments. In addition, it is time to expand the filed of the QA/QC management system, such as seawater temperature, salinity, PCBs and PAHs in sediments, which are mainly analyzed in most monitoring programs. On-site assessment has been conducted for 162 laboratories according to ISO/IEC 17025 to evaluate their conformity of the quality management system and deficiency. In terms of management and technology requirements, about 4.2% of organizations showed insufficient division of duties among employees 8.7% of them revealed the lack of employee training. By test item, about 6.3% of organizations showed the lack of standard substance management and the state of the cleaning glassware was pointed out in about 5.4% of them. The QA/QC management system should be continuously supplemented by identifying the causes of nonconformities and area for improvement.

Structural Performance Evaluation of a Multi-span Greenhouse with Venlo-type Roof According to Bracing Installation (가새 설치에 따른 벤로형 지붕 연동온실의 구조성능 평가)

  • Shin, Hyun Ho;Choi, Man Kwon;Cho, Myeong Whan;Kim, Jin Hyun;Seo, Tae Cheol;Lee, Choung Kuen;Kim, Seung Yu
    • Journal of Bio-Environment Control
    • /
    • v.31 no.4
    • /
    • pp.438-443
    • /
    • 2022
  • In this study, the lateral loading test was performed to analyze structural performance of multi-span plastic greenhouse through full-scale experiment and numerical analysis. In order to analyze the lateral stiffness and stress, we installed 9 displacement sensors and 19 strain gauge sensors on the specimen, respectively, and load of l mm per minute was applied until the specimen failure. In the comparison between the full-scale experiment and the structural analysis results of a multi-span greenhouse with venlo-type roof according to bracing installation, there was a large difference in the lateral stiffness of the structure. By installing a brace system, the lateral stiffness measured near the side elevation of the specimen increased by up 44%. As the bracing joint used in the field did not secure sufficient rigidity, the external force could not be transmitted to the entire structure properly. Therefore, it is necessary to establish a bracing construction method and design standards in order for a greenhouse to which bracing applied to have sufficient performance.

Defect Inspection and Physical-parameter Measurement for Silicon Carbide Large-aperture Optical Satellite Telescope Mirrors Made by the Liquid-silicon Infiltration Method (액상 실리콘 침투법으로 제작된 대구경 위성 망원경용 SiC 반사경의 결함 검사와 물성 계수 측정)

  • Bae, Jong In;Kim, Jeong Won;Lee, Haeng Bok;Kim, Myung-Whun
    • Korean Journal of Optics and Photonics
    • /
    • v.33 no.5
    • /
    • pp.218-229
    • /
    • 2022
  • We have investigated reliable inspection methods for finding the defects generated during the manufacturing process of lightweight, large-aperture satellite telescope mirrors using silicon carbide, and we have measured the basic physical properties of the mirrors. We applied the advanced ceramic material (ACM) method, a combined method using liquid-silicon penetration sintering and chemical vapor deposition for the carbon molded body, to manufacture four SiC mirrors of different sizes and shapes. We have provided the defect standards for the reflectors systematically by classifying the defects according to the size and shape of the mirrors, and have suggested effective nondestructive methods for mirror surface inspection and internal defect detection. In addition, we have analyzed the measurements of 14 physical parameters (including density, modulus of elasticity, specific heat, and heat-transfer coefficient) that are required to design the mirrors and to predict the mechanical and thermal stability of the final products. In particular, we have studied the detailed measurement methods and results for the elastic modulus, thermal expansion coefficient, and flexural strength to improve the reliability of mechanical property tests.

Analysis of Influence Factors on the Satisfaction of Viewers on China's CCTV-9 Channel (중국 CCTV-9 채널 시청자의 프로그램 관람 만족도 결정요인 분석)

  • Guo, Yuan;Wang, Zhifeng
    • Journal of Korea Entertainment Industry Association
    • /
    • v.15 no.8
    • /
    • pp.107-116
    • /
    • 2021
  • In recent years, the research on audience satisfaction after watching programs has been carried out in various fields. However, there is no precedent for the study of simply analyzing the influencing factors of audience satisfaction with the newly established CCTV-9 channel. For CCTV-9, how to explore the strategy of industrial development based on the needs of the audience in the era of big data is a very important part. This article exploratively focuses on the influencing factors related to CCTV-9 audience satisfaction. Using questionnaires, 101 samples of the satisfaction with the channel of men and women of different ages, education backgrounds, majors, and incomes were collected to test, and 9 hypotheses were tentatively proposed as relevant influencing factors of channel satisfaction. Through empirical analysis, this research searches for the determinants. The reliability and validity of the measurement were properly analyzed, and all hypotheses were statistically tested. The empirical results show that: subject matter, program format, program scheduling, program broadcast time, channel advertising, simulcast series of documentaries, diversified communication platforms, brand image packaging and audience satisfaction are significantly positively correlated.

Loneliness as a Risk Factor for Suicidal Ideation and Depressive Mood Among Korean Adolescents in 2020-2021 (한국청소년의 자살생각 및 우울감의 위험요인으로서의 외로움, 2020-2021년)

  • Inmyung Song
    • Journal of Industrial Convergence
    • /
    • v.21 no.5
    • /
    • pp.77-85
    • /
    • 2023
  • Suicide is the leading cause of death among Korean adolescents. There is a growing interest in the role of loneliness as a risk factor for suicide ideation and depressive symptoms. However, little is known in the Korean context. This study analyzed a total of 109,796 respondents from the Korea Youth Health Behavior Survey in 2020 and 2021. Multiple logistic regression models were implemented to test the association between loneliness and either of suicidal ideation and depressive mood. Covariates included demographic characteristics, school enrolled, household income, living arrangement, self-rated health, and the number of times treated for violence. Adjusted odd ratio (OR) and 95% confidence intervals (CI) were computed. 12.0% of adolescents reported to have felt lonely frequently and 3.0% always. 11.8% and 26.0% had suicidal ideation and depressive mood, respectively. The prevalence of suicidal ideation was higher in the always-lonely adolescents (52.6%) than in the frequently-lonely adolescents (35.1%). The always-lonely adolescents were nearly 30 times more likely to have suicidal ideation (OR=30.7; 95% CI, 27.1 - 34.8) and to feel depressed (OR=32.5; 95% CI, 29.2 - 36.4) than adolescents who felt never lonely. In conclusion, Loneliness was a major risk factor for suicidal ideation and depressive mood among Korean adolescents. Monitoring and addressing the condition of loneliness may help reduce suicidal ideation and depressive mood.

Modification of SPT-Uphole Method using Two Component Surface Geophones (2방향 지표면 속도계를 활용한 SPT-업홀 기법 개선 연구)

  • Bang, Eun-Seok;Kim, Jong-Tae;Kim, Dong-Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.2C
    • /
    • pp.109-120
    • /
    • 2006
  • SPT-Uphole test is a seismic field test using receivers on ground surface and a SPT (Standard penetration test) source in depth. Even though this method is simple and economic, it makes hesitate to apply in real field that it is difficult to obtain reliable travel time information of shear wave because of the characteristics of SPT impact source. To overcome this shortcoming, in this paper, modified SPT-Uphole method using two component surface geophones was suggested. Numerical analysis was performed using finite element method for understanding the characteristics of surface motion induced by in-depth vertical source, and comparison study of the various methods which determine the travel time information in SPT-Uphole method was performed. In result, it is thought that the most reasonable method is using the first local maximum point of the root mean square value signals of vertical and horizontal component in time domain. Finally, modified SPT-Uphole method using two component surface geophones was performed at the site, and the applicability in field was verified by comparing wave velocity profiles determined by the SPT-Uphole method with the profiles determined by SASW method and SPT-N values.

Bioequivalence Evaluation of Two Cefquinome 2.5% Injectable Products in Piglets (돼지에서 두 가지 Cefquinome 2.5% 제제의 생물학적 동등성 평가)

  • Song, In-Bae;Kim, Tae-Won;Lee, Hong-Gee;Kim, Myoung-Seok;Hwang, Youn-Hwan;Park, Byung-Kwon;Lim, Jong-Hwan;Yun, Hyo-In
    • Journal of Veterinary Clinics
    • /
    • v.29 no.3
    • /
    • pp.233-236
    • /
    • 2012
  • Cefquinome, a fourth generation cephalosporin, has been solely used for veterinary medicine and has a broad antibacterial spectrum against gram-negatives and gram-positives being very stable to ${\beta}$-lactamases. This study was conducted to evaluate the bioequivalence of two cefquinome 2.5% products in piglets. Plasma cefquinome concentrations were analyzed by liquid chromatography-mass spectrometry (LC/MS). Mean maximum concentration ($C_{max}$) of test product ($Cequus^{(R)}$) and reference product ($Cobactan^{(R)}$) were $4.34{\pm}0.58$ and $4.22{\pm}0.47{\mu}g/mL$, and mean area under the concentration time curve ($AUC_{0{\rightarrow}{\infty}}$) values were $10.43{\pm}1.96$ and $10.25{\pm}2.98{\mu}g{\cdot}h/mL$, respectively. The 90% confidence intervals for the ratio of $C_{max}$ (0.941-1.115), and $AUC_{0{\rightarrow}{\infty}}$ (0.927-1.172) values for the test and reference products were within the acceptable bioequivalence limit of 0.80-1.25. It is concluded that two commercial cefquinome injectable solutions are bioequivalent in their extent of drug absorption in piglets.

Development of an Official Analytical Method for Determination of Aclonifen in Agricultural Products Using GC-ECD (GC-ECD를 이용한 농산물 중 제초제 aclonifen의 공정분석법 확립)

  • Ko, Ah-Young;Kim, Hee-Jung;Jang, Jin;Lee, Eun-Hyang;Joo, Yoon-Ji;Kwon, Chan-Hyeok;Son, Young-Wook;Chang, Moon-Ik;Rhee, Gyu-Seek
    • Korean Journal of Environmental Agriculture
    • /
    • v.33 no.4
    • /
    • pp.388-394
    • /
    • 2014
  • BACKGROUND: Aclonifen is used as a systemic and selective herbicide to control a wide spectrum broad-leaf weeds by inhibition carotenoid biosynthesis, and then its MRLs(Maximum Residue Limits) will be determined in onion and garlic. In this study, a new official method was developed for aclonifen determination in agricultural products to routinely inspect the violation of MRL as well as to evaluate the terminal residue level. METHODS AND RESULTS: Aclonifen was extracted from crop samples with acetone and the extract was partitioned with dichloromethane and then purified by silica solid phase extraction(SPE) cartridge. The purified samples were detected GC using an ECD detector. Limits of detection(LOD) was 0.001 mg/kg and quantification(LOQ) was 0.005 mg/kg, respectively. For validation purposes, recovery studies were carried out at three different concentration levels (LOQ, $10{\times}LOQ$, $50{\times}LOQ$, n=5). The recoveries were ranged from 74.3 to 95.0% with relative standard deviations(RSDs) of less than 8%. All values were consistent with the criteria ranges requested in the Codex guidelines(CAC/GL 40). CONCLUSION: The proposed analytical method was accurate, effective and sensitive for aclonifen determination and it will be used to as an official method in Korea.

Test Bed Studies with Highly Efficient Amine CO2 Solvent (KoSol-4) (고효율 습식 아민 CO2 흡수제(KoSol-4)를 적용한 Test bed 성능시험)

  • Lee, Ji Hyun;Kwak, No-Sang;Lee, In Young;Jang, Kyung Ryoung;Jang, Se Gyu;Lee, Kyung Ja;Han, Gwang Su;Oh, Dong-Hun;Shim, Jae-Goo
    • Korean Chemical Engineering Research
    • /
    • v.51 no.2
    • /
    • pp.267-271
    • /
    • 2013
  • Test bed studies with highly efficient amine $CO_2$ solvent (KoSol-4) developed by KEPCO research institute were performed. For the first time in Korea, evaluation of post-combustion $CO_2$ capture technology to capture 2 ton $CO_2$/day from a slipstream of the flue gas from a coal-fired power station was performed. Also the analysis of solvent regeneration energy was conducted to suggest the reliable performance data of the KoSol-4 solvent. For this purpose, we have tested 5 campaigns changing the operating conditions of the solvent flow rate and the stripper pressure. The overall results of these campaigns showed that the $CO_2$ removal rate met the technical guideline ($CO_2$ removal rate: 90%) suggested by IEA-GHG and that the regeneration energy of the KoSol-4 showed about 3.0~3.2 GJ/$tCO_2$ which was, compared to that of the commercial solvent MEA (Monoethanolamine), about 25% reduction of regeneration energy. Based on these results, we could confirm the good performance of the KoSol-4 solvent and the $CO_2$ capture process developed by KEPCO research institute. And also it was expected that the cost of $CO_2$ avoided could be reduced drastically if the KoSol-4 is applied to the commercial scale $CO_2$ capture plant.