Equipment for Measuring the Adiabatic Temperature Rise of Concrete by Compensating Heat Loss (열손실량 보정을 통한 콘크리트 단열온도상승량 예측 장치)

  • Jin, Eun-Woong;Kim, Chin-Yong;Kim, Jin-Keun
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.5
    • /
    • pp.535-542
    • /
    • 2012
  • Adiabatic temperature rise test for predicting heat of hydration in mass concrete is especially inconvenient in the field. In order to overcome the problem, the equipment to effectively and conveniently measure semi-adiabatic temperature change was developed. The main objective of this paper is to propose a new and simple equipment for measuring semi-adiabatic temperature rise by using insulation bottles. In order to predict exact heat loss of concrete using this device, it is required to assume the specific heat loss coefficient of the device by water temperature change inside the experimental device. According to experimental and analytical results, the adiabatic temperature rise does not have significant differences in changes of temperature and humidity of air, as well as initial temperature of water. By comparing adiabatic temperature rise tests, the equipment for measuring semi-adiabatic temperature change can be used to predict the hydration heat of concrete within sufficient accuracy.

Development of Decompressed Dryer for Mushroom (버섯의 감압건조기 개발)

  • 김영민;김유호;조영길;최희석;조광환
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2003.07a
    • /
    • pp.267-272
    • /
    • 2003
  • 본 연구에서는 버섯의 건조시간을 줄여 건조 후 버섯의 품질을 향상시키기 위하여 버섯의 감압건조기를 개발하였으며 연구 결과는 다음과 같다. 가. 버섯의 감압건조기의 시작기를 제작하였고, 시작기의 구조는 건조실, 감압블로워, 흡ㆍ배기구 솔레노이드 밸브, 제습장치, 송풍기, 전기히터로 구성되어 있으며, 건조실의 내부 압력이 표준대기압-900hPa, 열풍온도는 상온에서 5$0^{\circ}C$까지 조절할 수 있도록 제작하였다. 나. 시작기를 이용하여 표고버섯을 대상으로 건조특성시험을 실시한 결과, 열풍온도 5$0^{\circ}C$, 건조실 내부압력 900-940hPa에서 건조시간은 11.5h으로 대기압과 비교하여 6.5h 단축되는 것으로 나타났다. 또한, 건조 전ㆍ후의 색차, 수축률, 복원률의 품위가 우수한 것으로 나타났으며 F-test 유의성 검증 결과, 5%의 유의수준에서 갓주름의 색차, 갓직경의 수축률, 복원률에서 유의차가 있는 것으로 나타났다. 다. 열풍온도 5$0^{\circ}C$, 건조실 내부압력 900-940hPa로 표고버섯과 아가리쿠스에 대하여 건조성능시험을 실시한 결과, 표고버섯의 경우 건조시간은 13h으로 열풍식 농산물 건조기와 비교하여 건조시간이 4.5h 단축되는 것으로 나타났으며, 아가리쿠스의 경우 건조시간이 17.5h로 나타났다. 라. 성능시험 결과, 시작기가 열풍식 농산물건조기와 비교하여 건감률, 색택, 수축률, 복원률 등의 품위가 전반적으로 우수한 것으로 나타났다. 마. 시작기의 건조비용을 분석한 결과, 건조시간은 단축되었지만 시설투자비가 높아 건조비용이 표고버섯의 경우 2,461원/kg으로 열풍식 농산물건조기 보다 13% 높은 것으로 나타났지만, 추후 고품질 건조버섯 생산을 위한 기초자료로 활용이 가능할 것으로 판단된다.라갈수록 낮은 온도분포를 나타내고 있는 것은 상부에는 외부공기가 유입되면서 온도가 떨어지는 반면 하부에는 외부공기 유입이 적기 때문으로 사료된다. 또한 열풍실의 길이방향 위치별 온도 분포에서도 같은 현상으로 나타났고, 버너쪽과 송풍기쪽의 온도편차는 나타나지 않아 균일 건조를 기대할 수 있다. 마. 열풍온도를 45$^{\circ}C$로 설정하고 조사거리와 방사체 길이를 각각 119, 1,470mm로 하여 벼의 건조성능시험을 열풍건조기(대비구)와 비교시험 결과 시험구에서 건감률, 건조소요에너지가 각각 0.58%(w.b.), 470kcal/kg - water로 대비구보다 각각 건감율은 23% 높았고, 건조소요에너지는 2%의 절감되었다. 바. 건조기에서 발생되는 소음은 버너쪽 근처에서는 대비구 94.12㏈의 87%에 불과하였으나, 거리가 멀어질수록 차이는 크지 않았다. 이것은 버너에서 멀어질수록 외부적인 요인이 소음에 영향을 미쳤기 때문인 것으로 생각된다. 사. 시작기와 대비구간의 경제성에서 시작기의 구입가격이 20% 비싸기 때문에 시간당 고정비가 높았으나, 건조성능이 우수하여 건조비용이 69,350원/톤으로 대비구보다 14% 절감되는 것으로 나타났다.작용하는 것으로 사료된다.된다.정량 분석한 결과이다. 시편의 조성은 33.6 at% U, 66.4 at% O의 결과를 얻었다. 산화물 핵연료의 표면 관찰 및 정량 분석 시험시 시편 표면을 전도성 물질로 증착시키지 않고, Silver Paint 에 시편을 접착하는 방법으로도 만족한 시험 결과를 얻을 수 있었다.째, 회복기 중에 일어나는 입자들의 유입은 자기폭풍의 지속시간을 연장시키는 경향을 보이며 큰 자기폭풍일수록 현저했다. 주상에서 관측된 이러한 특성은 서브스톰 확장기 활동이 자기폭풍의 발달과 밀접한 관계가 있음을 시사한다.se that were all

  • PDF

Performance evaluation of Surface Temperature Reduction by using Green infrastructure Surface Temperature Measurement for Urban Heat Island Mitigation (도시열섬완화를 위한 그린인프라시설의 표면온도 저감 성능평가)

  • Ko, Jong Hwan;Bae, Woo Bin;Park, Dae Geun;Jung, Won Kyong;Park, Yun mi;Kim, Yong Gil;Kim, Sang Rae
    • Ecology and Resilient Infrastructure
    • /
    • v.5 no.4
    • /
    • pp.257-263
    • /
    • 2018
  • This study is to develop a GSTM (Green infrastructure Surface Temperature Measurment) equipment for reducing the surface temperature of GI by using LID Method. The tests were conducted including GI products such as Greening block, Pervious Block, Soil Block and so on. The GSTM equipment developed by considering the literature surveys are characterized as follows. The non-contact infrared temperature sensor was used to measure the surface temperature, and it was improved to measure the overall average temperature including the center and the corner temperature of the specimen. The developed GSTM equipment was used to compare performance of asphalt and GI products. As a result, the Greening Block show a high difference of $18.4^{\circ}C$ and it contributes to the decrease of surface temperature.

An Experimental Study on the Evaluation of Adiabatic Temperature Rise of Concrete (콘크리트의 단열온도 상승량의 정량화에 관한 실험적 연구)

  • 강석화;이용호;정한중;박칠림
    • Magazine of the Korea Concrete Institute
    • /
    • v.7 no.6
    • /
    • pp.186-196
    • /
    • 1995
  • In this study, parameters such as unit cement weight and placing temperature which influence on temperature rise and temperature rise velocity are investigated through adiabatic tests for the domestic ordinary portland cement(0PC). Adiabatic temperature rise suggested by Korean Concrete Spec. are compared with that from this experimental results. As a result of this study, adiabatic temperature rise of OPC suggested spec. is overestimated. Also it is shown that 2-parameter equation suggested in the spec. overestimate heat evolution at early age and reasonable prediction of heat evolution can be obtained by using 3-parameter equation. Results of numerical analysis by using the input data from this test and the suggested values from spec. shows similar temperatures. However thermal stresses pridicted using input value from spec. may result 20% more than that from this test in case of externally restricted state.

Thermal Stability Test Evaluation of Applying the Artificial-Crack of Water-Leakage Repair Materials Used in the Maintenance of Concrete Structure (콘크리트 구조물의 유지보수에 사용되는 누수보수재료의 인공 균열을 이용한 온도 안정성 시험평가)

  • Kim, Soo-Youn;Kim, Byoung-ll;Oh, Sang-Keun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.3
    • /
    • pp.322-329
    • /
    • 2016
  • This study is about the method to control the quality of material used to repair leakage and crack of concrete structure and suggests the "Temperature Stability Test Method" as a follow-up study. In the result of performance evaluation for 45 samples of 15 types in 5 series, the temperature stability test showed different material changes including rolling down, volume change, and color change as they are frozen and melt repeatedly in the somewhat extreme conditions at low($-20^{\circ}C$) and high($60^{\circ}C$) temperatures, where 13 samples (approx. 29%) and 32 samples (approx. 71%) showed leakage, respectively, in the permeability test to evaluate leakage. This result shows the enough importance of setting the quality control criteria of leakage repair material currently used to maintain concrete structures considering the temperature conditions, and proves the applicability of the Temperature Stability Test Method as a standard test method to ensure long-term durability of concrete structure.

Pseudo-Power Cycling을 이용한 솔더 조인트의 가속시험

  • Kim, Il-Ho;Lee, Sun-Bok
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2006.05a
    • /
    • pp.32-39
    • /
    • 2006
  • 전자 부품의 신뢰성 평가를 위해서 다양한 방법의 시험법이 사용된다. 전자 부품은 반복적인 작동과 휴식에 의한 열피로를 받게 된다. 이에 대한 신뢰성 평가를 위해 오래전부터 다양한 시험 규격이 만들어지고, 그에 따라 열챔버를 이용한 챔버 사이클링 시험이 수행되고 있다. 하지만, 최근에는 이러한 시험 규격들에 대한 문제가 지적되고 있으며, 또한 챔버 사이클링을 이용한 가속 실험의 경우 실제 작동환경을 완벽히 묘사하지 못하며, 가속할 수 있는 정도가 제한되고 있다. 본 연구에서는 파워 사이클링 시험을 묘사하는 시험 방법을 제안하고, 그를 이용하여 BGA 패키지의 솔더 조인트에 대한 열피로 시험을 수행하였다. 본 연구에서 제안된 파워 사이클링 시험기는 실제 작동 환경과 유사한 온도 구배를 패키지에 만들어 준다. 그리고 패키지에 열전도를 이용하여 열을 공급함으로써, 대류를 통해 열을 공급하는 챔버 사이클링 시험에 비해 빠르게 가열 및 냉각이 가능하다. 파워사이클링 테스트 방법을 이용하여 다양한 온도 조건에 대해 열피로 수행하여 솔더 조인트의 열피로 특성을 평가하였다.

  • PDF

소형펀치시험법에 의한 발전용 증기관의 경년재질열화 평가에 의한 연구

  • 김정기;이종기;윤기봉;정세희
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.5
    • /
    • pp.1665-1673
    • /
    • 1991
  • 본 연구에서는 운전이력이 다른 보일러 과열기 및 재열기에서 수취한 Cr-Mo강 증기관을 대상으로 이 SP 시험법을 도입하여 SP시험에 의한 재질열화의 평가 가능성을 연구 검토하였다.

Analysis and test of athermalizaion for 20:1 zoom thermal imaging system (20:1 줌 열영상 장비 비열화 분석 및 시험)

  • 김현숙;최세철;최세철;이국환;박용찬;김현규
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.4
    • /
    • pp.281-288
    • /
    • 2001
  • In this study we carried out athermalization analysis and tests to meet the required optical performance for thennal imaging systems even if the systems were operating over a wide temperature range. By using optical design programs such as Code- V and SIGMA2100, the simulation for athermalization was done with FPA thermal imaging system. In the athermalization test putting the thermal imaging system and collimator into a temperature chamber, the images depending on the temperature were recorded on video tape. In particular, the zoom thermal imaging system with two dimensional array detector was tested to check the result of the athermalization simulation. As a result, it was proved to meet the required optical performance for the thermal imaging system within $-32-+50^{\circ}C$ temperature range. range.

  • PDF

Integrity of Optical Fiber Sensor for Measurement of Ground Thermal Conductivity (지중 열전도도 측정을 위한 광섬유 센서의 건전성)

  • Yoon, Seok;Choi, Jung-Chan;Lee, Seung-Rae;Lee, Michael-MyungSub
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.157-160
    • /
    • 2011
  • 본 연구에서는 광섬유 센서 기반 스마트 모니터링 시스템이 지중 열전도도 측정에도 효율적으로 적용될 수 있는지를 분석하였다. 이를 위해 광섬유 온도센서를 이용하여 지반의 열전도도를 측정할 수 있는 열응답 시험기가 개발되었다. 개발된 열응답 시험기는 기존의 RTD(Resistance Temperature Detector) 온도 센서 외에 광섬유 센서의 한 종류인 FBG(Fiber Bragg Grating) 센서도 실시간적으로 측정할 수 있는 시스템으로 구성되어 있다. 개발된 장비의 적용성 검증을 위하여 주문진 표준사를 이용하여 모형토조 내에 일정한 간극비에 맞추어 시료가 조성되었으며 지중열교환기는 U자형 파이프가 사용되었다. 20시간동안 열응답 시험을 통하여 광섬유 센서와 RTD 센서를 동시에 이용하여 온도값을 측정하여 표준사의 열전도도 값을 산출하였다. 그 결과 모형실험을 통한 열전도도 값은 탐침법을 통해 얻어진 열전도도 값과 선형 열원 모델(line source model) 해석해와 거의 유사하게 나타났으며 광섬유 센서와 RTD 센서와의 온도차는 0.1~0.3$^{\circ}$로써 유사한 값을 나타내었다. 따라서 본 연구에서 개발된 광섬유 기반 열응답 시험기는 지반의 열전도도를 측정하는데 효과적으로 사용될 수 있음을 알 수 있었으며 향후 지열시스템 가동에 따른 지중열 교환기의 손상도 평가 및 경보시스템 개발을 위해 지중열교환기의 거동을 실시간으로 모니터링 하는데 있어서도 효과적으로 사용될 수 있을 것으로 생각된다.

  • PDF

A Study on the Nozzle Flow in the Sub-scale High-Altitude Test (축소형 고공환경모사 시험에서의 노즐 유동에 관한 연구)

  • Choi, Jiseon;Lee, Seongmin;Lee, Heejune;Ko, Youngsung;Kim, Seonjin;Lee, Jungmin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.1011-1015
    • /
    • 2017
  • In this study, numerical and experimental studies on the nozzle flow in a sub-scale cold flow test were conducted to simulate high altitude condition. In the theoretical calculation, the temperature of the nozzle outlet is calculated to be lower than the liquefaction point, and the fluid exists at the phase change point. Also, numerical analysis result is higher than theory calculation but lower than liquefaction temperature. As a result of cold flow test, it was confirmed that the temperature was much higher than theory and analysis. This is because it assumed that it is adiabatic in the theoretical calculation, but the experiment in the actual environment is not the adiabatic but the heat exchange with the outside exists.

  • PDF