• Title/Summary/Keyword: 시험연소로

Search Result 1,285, Processing Time 0.035 seconds

Application of Fire Risk and Fire Risk Rating Assessment for Four Species of Wood According to Chung's Equation-XII (Chung's Equation-XII에 의한 목재 4종의 화재위험성 및 화재위험성 등급 평가 적용)

  • Yeong-Jin Chung;Eui Jin
    • Applied Chemistry for Engineering
    • /
    • v.35 no.1
    • /
    • pp.29-36
    • /
    • 2024
  • The fire risk and fire safety of four types of wood were comprehensively evaluated according to Chung's equation-XII. White ash, willow, fraxinus mandshurica, and sagent cherry trees were selected as test specimens. A cone calorimetery (ISO 5660-1) was used to examine the combustion characteristics of the test piece, and finally, the fire risk rating (FRR) was predicted using the fire risk index-XII (FRI-XII). The predicted fire performance index-X (FPI-X) and fire growth index-X (FGI-X) ranged from 469.03 to 1109.73 s2/kW and 0.0009 to 0.0280 kW/s2, respectively. Additionally, the fire performance index-XI (FPI-XI) and fire growth index-XI (FGI-XI) ranged from 0.41 to 0.97 and 1.11 to 3.11, respectively. The fire risk index-XII (FRI-XII), representing a fire risk rating, showed that the fire risk of frasxinus mandsurica tree (FM) was very high at 7.60 (fire risk rating: D). And it was compared with Chung's equation-IX, fire risk index-IX (FRI-IX). The fire risk ratings according to FRI-IX and FRI-XII were generally high for willow and frasxinus mandsurica trees. Additionally, the results of FRI-XII and FRI-IX had a similar relationship, and the size of each fire safety rating closely matched each other.

Fire Risk Prediction and Fire Risk Rating Evaluation of Four Wood Types by Comparing Chung's Equation-IX and Chung's Equation-XII (Chung's Equation-IX과 Chung's Equation-XII의 비교에 의한 목재 4종의 화재위험성 예측 및 화재위험성 등급 평가)

  • JiSun You;Yeong-Jin Chung
    • Applied Chemistry for Engineering
    • /
    • v.35 no.3
    • /
    • pp.200-208
    • /
    • 2024
  • Chung's equations-IX and Chung's equation-XII were utilized to predict the fire risk and evaluate fire risk ratings for four types of wood: camphor, cherry, rubber, and elm trees. The combustion tests were conducted using a cone calorimeter test method by ISO 5660-1 standards. The fire risk and fire risk rating (FRR) were compared for Fire Risk Index-IX (FRI-IX) and Fire Risk Index-XII (FRI-XII). The results yielded Fire Performance Index-XI (FPI-XI) ranging from 0.08 to 11.48 and Fire Growth Index-XI (FGI-XI) ranging from 0.67 to 111.89. The Fire Risk Index-XII (FRI-XII), indicating fire risk rating, exhibited an increasing order of cherry (0.45): Grade A (Ranking 5) < PMMA (1): Grade A (Ranking 4) < elm (1.23): Grade A (Ranking 3) < rubber (1.56): Grade A (Ranking 2) << camphor (148.23): Grade G (Ranking 1). Additionally, the fire risk index-IX (FRI-IX) was cherry (0): Grade A (Ranking 3) ≈ rubber (0): Grade A (Ranking 3) ≈ elm tree (0): Grade A (Ranking 3) < PMMA (1): Grade A (Ranking 2) << camphor tree (66.67): Grade G (Ranking 1). In general, camphor was found to have the highest fire risk. In conclusion, although the expression of the index is different as shown based on the standards of FRI-IX and FRI-XII, predictions based on fire risk assessment of combustible materials showed similar trends.

Prediction of Fire Risk and Fire Risk Grade of Five Wood Species by Chung's Equation-IX and Chung's Equation-XII (Chung's equation-IX 및 Chung's equation-XII에 의한 목재 5종의 화재위험성과 화재위험성등급 예측)

  • JiSun You;Yeong-Jin Chung
    • Applied Chemistry for Engineering
    • /
    • v.35 no.5
    • /
    • pp.458-467
    • /
    • 2024
  • Chung's equation-IX and Chung's equation-XII were utilized to predict the fire risk and evaluate fire risk ratings for five types of wood: white ash, hard maple, willow, fraxinus mandschurica, and sagent cherrys. The combustion tests were conducted using a cone calorimeter test method by ISO 5660-1 standards. The fire risk and fire risk rating (FRR) were compared with fire risk index-IX (FRI-IX) and fire risk index-XII (FRI-XII). The results yielded a fire performance index-XI (FPI-XI) ranging from 0.44 to 1.05 and a fire growth index-XI (FGI-XI) ranging from 0.89 to 3.11. Also, the fire risk index-XII (FRI-XII), indicated fire risk rating, exhibited an increasing order of sagent cherry (0.85): Grade A ≈ PMMA (1): Grade A ≈ white ash (1.22): Grade A ≈ hard maple (1.53): Grade A < willow (4.00): Grade C < faxinus mandschurica (7.07): Grade D. Additionally, the fire risk index-IX (FRI-IX) was PMMA (1): Grade A ≈ hard maple (2.28): Grade A ≈ sagent cherry (3.24): Grade A < white ash (5.73): Grade B < fraxinus mandschurica (10.29): Grade C ≪ willow (48.30): Grade G. In general, the willow and fraxinus mandschurica showed the highest fire risk. In conclusion, although the expression of the index is different as shown based on the criteria of FRI-IX and FRI-XII, predictions based on fire risk assessment of combustible materials showed a similar tendency.

Comparative Study on the Performance of Small Satellites Launch Vehicle Employing ElecPump Cycle Upper Stage Engine (전기펌프 사이클 상단 엔진을 적용한 소형발사체 성능 비교연구)

  • Yu, Byungil;Kwak, Hyun-Duck;Kim, Hongjip
    • Journal of Aerospace System Engineering
    • /
    • v.14 no.5
    • /
    • pp.107-121
    • /
    • 2020
  • The performance analysis of the small satellites launch vehicle using the electric pump cycle as the upper stage engines was performed. The first stage is the launch vehicle that uses the test launch vehicle of the Korea Space Launch Vehicle II and the second stage employs elecpump cycle engine that uses liquid methane and kerosene (RP-1) as fuel. A model for the mass estimation was presented and the analysis was conducted for the range of thrust of 20 to 40 kN and combustion pressure of 3 to 6 MPa with a nozzle expansion ratio of 60 to 100. The mixture ratio with the maximum velocity increment was calculated and the performance of the LEO and SSO payload were calculated from the stage mass estimation. In both the cases, liquid methane, and RP-1 showed maximum payload for 20 kN thrust, 3 MPa combustion pressure, and the nozzle expansion ratio of 100, with a mixture ratio of 3.49 for liquid methane and 2.75 for RP-1. In addition, the ditching points of the first stage and the fairing in the LEO mission were analyzed using ASTOS.

The Characteristics of Particulate PAHs Concentrations at a Roadside in Seoul (서울시 도로변에서 입자상 다환방향족탄화수소의 농도 특성)

  • Lee, Ji-Yi;Kim, Yong-Pyo;Bae, Gwi-Nam;Park, Su-Mi;Jin, Hyun-Chur
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.2
    • /
    • pp.133-142
    • /
    • 2008
  • Five intensive measurements of particulate PAHs were made at a roadside in Seoul from May 2005 to June 2006. The average concentration of particulate PAHs was $15.1{\pm}10.6ng\;m^{-3}$. The high concentrations of particulate fluoranthene and pyrene were observed in November 2005 due to the influence of the lower ambient temperature. Compared to the previous results at tunnel and ambient sites in Seoul, larger fraction of the high molecular PAH compounds which consist with five or six benzene rings, was observed at a roadside. This might indicate high influence of vehicle emission at a roadside. The distribution of diagnostic ratios for specific PAH compounds indicated that the influence of vehicular emission, especially diesel vehicular emission seems to be high at a roadside.

Preparation of Photosynthesis Nanofiber Composite Membrane by Using Chlorophyll and Polymer Nanofiber (식물 엽록소와 고분자 나노섬유를 이용한 광합성 나노섬유복합막의 제조)

  • Yun, Jaehan;Jang, Wongi;Byun, Hongsik
    • Membrane Journal
    • /
    • v.25 no.1
    • /
    • pp.75-83
    • /
    • 2015
  • In this study, chlorophylls were been extracted from common local plants, deposited on polypropylene (PP) substrate using various approaches, and the oxygen generation effect of the chlorophylls were investigated. The loading of chlorophylls on the substrates was achieved by dipping and spraying methods, where the spraying coating showed overall better results regarding oxygen generation from the combustion experiments in the closed vessel or in the isolated vacuum oven cell than those of dip coating. In addition, a composite substrate was prepared by nylon6/6 nanofiber on the PP substrate, and it exhibited an increase in the activation of chlorophylls. In the case of samples containing titanium dioxide ($TiO_2$), the reaching time of oxygen concentration from 16% to 21% and the combustion test using a candle for a sample with 50% chlorophylls showed similar results to those of a sample without $TiO_2$. As such, combining a spray coating and $TiO_2$ incorporation into gas separation membrane systems are expected to be useful to understand the fundamentals of material properties for their applications as oxygen generation membranes and air filtration systems.

The Heavy Metals Recovery from Carbonized CCA Treated Wood (CCA방부목재의 탄화가 중금속 회수에 미치는 영향)

  • Son, Dong-won;Cheon, Seon-Hae;Lee, Myung Jae;Lee, Dong-heub
    • Journal of the Korean Wood Science and Technology
    • /
    • v.33 no.6 s.134
    • /
    • pp.95-100
    • /
    • 2005
  • The using amount of preservative-treated wood equipments has been increased. Specially, chromate copper arsenate (CCA) has been widely used to exterior wood. We are faced to the disposal problem after service period of CCA treated wood due to its toxic heavy metals. For the disposal of end-used treated wood, land-filling and incinerating methods are mainly applied. The essential problem of incinerating is an arsenic release into atmosphere. Low pyrolysis is suggested as the methods of protecting arsenic release during incineration. The heavy metals were recovered after combustion of the treated wood at the low temperature which arsenic can not released. The recovery amounts of effectiveness compounds was determined in various solvents (citric acid, nitric acid, sulfuric acid, acetic acid, phosphoric acid) and different temperature (300, 400, $500^{\circ}C$). The higher temperature was applied, the more copper was recovered. The chromium was difficult to be recovered on the carbonized CCA treated wood at 0.5% acid concentration. The recovery mass of arsenic decreased on the higher combustion treated wood. The recovery of chromium was difficult due to the chemical change of the chromium arsenate during pyrolysis.

A Study on Functionality of the Ulreungdo Seokganju as Korean Traditional Red Pigment (한국 전통 적색광물안료 울릉도석간주의 기능성 연구)

  • Do, Jin-Young;Kim, Soo-Jin;Lee, Sang-Jin;Ahn, Byung-Chan;Yun, Seong-Chul;Kim, Kwang-Jong
    • Journal of the Mineralogical Society of Korea
    • /
    • v.22 no.2
    • /
    • pp.153-162
    • /
    • 2009
  • The main compositions of "Seokganju", a Korean traditional red mineral pigment, are iron oxides. To investigate its mineralogical and functional properties, we had got its ore from Juto cave in Ulreoung island, which was a famous field of it in Korean documents. The ore occurs as a paleosol between the olivine basalt and amphibole trachyte in discontinuously. It is reddish brown and yellowish brown and consists mainly of clay minerals with minor debris. Its reddish and yellowish brown color are due to the hematite and ferrihydrate, respectively. These iron oxides are precipitated as ferrihydrate from the ferrous water in the paleosol and partly changed to hematite. The color reproduced in timber by using seokganju pigment with traditional tools and methods is similar to that in heritage building. The moistureproofing and fire resistance of Ulreungdo seokganju is far better than that of artificial seokganju. Moreover, the combustion tests show that the artificial seokganju promote the ignition and combustion of the timber. Ulreungdo seokganju is regarded as a pigment with fungicidal efficacy because growth of two wood decay fungi (cov. and typ.) are inhibited in solid medium with it.

Experimental Study on the Self-extinguishing Performance of Extruded Polystyrene Insulation for Buildings and Suggestions on Institutional Management (건축용 압출법 단열판(XPS)의 자기소화성에 대한 실험적 연구 및 제도적 관리에 관한 제언)

  • Kang, Jung Ki;Choi, Don Mook
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.141-149
    • /
    • 2020
  • The Korea Industrial Standards (KS) stipulates methods and test procedures for measuring the horizontal combustibility of cellular plastics exposed to small flames (KS M ISO 9772:2018) and recommendations regarding the magnetic digestion of extruded polystyrene insulation (XPS) for measurement results (KS M 3808:2020). Although products that are certified to conform to KS standards must have burning characteristics (self-extinguishing), they are incinerated and spread by welds at construction sites, causing significant human and property damages. In this study, XPS produced by five companies, certified by KS, and sold in the market were purchased and tested for ignition and diffusion caused by a weld bullion at a construction site. The results showed that the five products had differences in performance. Three out of the five products were found to be self-saturated, but the other two were easily ignited and diffused, making it difficult for them to be self-extinguishing. Based on the result of this experimental investigation in line with the KS regulations, all the three types of products, including two types of products that were incinerated through weld defects, were found to be non-self-extinguishing, as specified in KS M 3808.

Risk of Smoke Occurring in the Combustion of Plastics (플라스틱의 연소 시 발생하는 연기 위험성에 관한 연구)

  • You, Jisun;Chung, Yeong-jin
    • Fire Science and Engineering
    • /
    • v.33 no.1
    • /
    • pp.69-75
    • /
    • 2019
  • In this study, the combustibility of five types of plastic plates, fiber reinforced plastic (FRP), polystyrene (PS), polycarbonate (PC), polypropylene (PP), and polyvinyl chloride (PVC), were tested using a cone calorimeter (ISO 5660). The PVC plate showed a $44.65kW/m^2$ lower peak heat release rate (HRR) and a $30.97kW/m^2$ lower maximum average rate of heat emission than the other four types of plastics, whereas the PS plate showed a $773.44kW/m^2$ higher peak HRR and $399.14kW/m^2$ higher maximum average rate of heat emission. The PC plate and PS plate showed the highest HRR by a maximum of 3.88 times in $CO_{mean}$ yields, while the PS pate and PP plate showed the highest HRR by a maximum 4.88 times in $CO_{2mean}$ yields. In addition, the smoke performance index (SPI) of the PS plate decreased by 74.81%~95.99%; the smoke growth index (SGI) increased to 76%~300%; the smoke intensity (SI) also increased to 917.73% ~ 9607.57%, and the danger of smoke increased. The PS plate was found to have the highest risk of life damage due to smoke on the thermal and smoke sides.