• Title/Summary/Keyword: 시험설계

Search Result 6,774, Processing Time 0.033 seconds

Estimated EC by the Total Amount of Equivalent Ion and Ion Balance Model (등가 이온 총량에 따른 EC 추정과 이온 균형 모형)

  • Soh, Jae-Woo;Lee, Yong-Beom
    • Horticultural Science & Technology
    • /
    • v.30 no.6
    • /
    • pp.694-699
    • /
    • 2012
  • To examine the EC model in a culture medium, basic culture medium of Rush (2005) and EC model of Robinson and Strokes (1959) were applied analyzing the equivalence ion total amount, the EC variable of cation and anion. Following the experiential translation by Steiner (1980), 130 optimized domestic and foreign culture media for crop growth were utilized, and estimated EC model was also demonstrated. Results from basic culture medium of Rush (2005) suggests an estimated EC by equivalence ion total amount and high reliable regressive model with 0.96 y = 1.33x - 0.23 of 0.96 as value $R^2$. It was found out that the change in concentration of positive ion and anion did not differ significantly with the increase and decrease of EC, however, there occurred a slight variable range. The change brings about a bigger anion influence than the previously reported positive ion, seemingly like those based on nitride ion and sulfur ion. The above EC estimated models confirmed that with optimized 130 domestic and foreign culture media for crop growth, the value derived will be as follows: $R^2$ = 0.98 with y = 1.23x - 0.02. In addition, the contour analysis of positive ion and anion for EC, with popularly known concentration range of EC $1.5-2.5dS{\cdot}m^{-1}$ reveals an equivalent of more than $11meq{\cdot}L^{-1}$ for positive ion and $15meq{\cdot}L^{-1}$ for anion. On the other hand, the left bottom, low concentration $1.5dS{\cdot}m^{-1}$ and the right above, high concentration $2.5dS{\cdot}m^{-1}$, for both positive ion and anion existed differently in a proper culture medium concentration. This study adapted variables of both positive ion and anion of EC simultaneously, unlike in the previous culture medium by ion ratio in mutual ratio of Steiner (1980), and offers an EC model that can estimate levels or positive ion and anion in proper concentration, EC $1.5-2.5dS{\cdot}m^{-1}$, with distributed features of ions.

TV Anytime and MPEG-21 DIA based Ubiquitous Consumption of TV Contents in Digital Home Environment (TV Anytime 및 MPEG-21 DIA 기반 콘텐츠 이동성을 이용한 디지털 홈 환경에서의 유비쿼터스 TV 콘텐츠 소비)

  • Kim Munjo;Yang Chanseok;Lim Jeongyeon;Kim Munchurl;Park Sungjin;Kim Kwanlae;Oh Yunje
    • Journal of Broadcast Engineering
    • /
    • v.10 no.4 s.29
    • /
    • pp.557-575
    • /
    • 2005
  • Much research in core technologies has been done to make it possible the ubiquitous video services over various kinds of user information terminals anytime anywhere in the way the users want to consume. In this paper, we design plototypesystem architecture for the ubiquitous TV program content consumption based on user preference via various kinds of intelligent information terminals in digital home environment, and present an implementation and testing results for the prototype system. For the system design, we utilize the TV Anytime specification fur the consumption of TV program contents based on user preference in TV programs, and also use the MPEG-21 DIA (Digital Item Adaptation) tools which are the representation schema formats in order to describe the context information for user environments, user terminal characteristics, user characteristics for universal access and consumption of the preferred TV program contents. The proposed ubiquitous content mobility prototype system is designed to make it possible to seamlessly consume contents by a single user or multiple users via various kinds of user terminals for the TV program contents they watch together. The proposed ubiquitous content mobility prototype system in digital home environment consists of a home server, a display TV terminal, and an intelligent information terminal. We use 42 TV programs contents in eight different genres from four different TV channels in order to test our prototype system.

Mechanism and Spray Characteristics of a Mini-Sprinkler with Downward Spray for Prevention of Drop Water (하향 분사식 미니스프링클러의 낙수방지 메카니즘과 살수 특성)

  • Kim, Hong-Gyoo;Chung, Sung-Won
    • Journal of Bio-Environment Control
    • /
    • v.16 no.3
    • /
    • pp.210-216
    • /
    • 2007
  • A study was conducted to find mechanism and spray characteristics of a mini-sprinkler with downward spray to develop a new design type to be able to prevent drop water. The experiments were executed in a plastic greenhouse to minimize the effect of the wind. Data was collected at five different operation pressures and at 4 different raiser heights. Spray characteristics of the sprinkler such as effective radius, effective area, mean application depth, absolute maximum application depth, effective maximum application depth and coefficient of variation were determined. In order to analyze the mechanism and packing supporter of sprinkler, the numerical simulation using ABAQUS was performed. The optimum pressure for preventing drop water was determined.

Dynamic Behavior of Reactor Internals under Safe Shutdown Earthquake (안전정기지진하의 원자로내부구조물 거동분석)

  • 김일곤
    • Computational Structural Engineering
    • /
    • v.7 no.3
    • /
    • pp.95-103
    • /
    • 1994
  • The safety related components in the nuclear power plant should be designed to withstand the seismic load. Among these components the integrity of reactor internals under earthquake load is important in stand points of safety and economics, because these are classified to Seismic Class I components. So far the modelling methods of reactor internals have been investigated by many authors. In this paper, the dynamic behaviour of reactor internals of Yong Gwang 1&2 nuclear power plants under SSE(Safe Shutdown Earthquake) load is analyzed by using of the simpled Global Beam Model. For this, as a first step, the characteristic analysis of reactor internal components are performed by using of the finite element code ANSYS. And the Global Beam Model for reactor internals which includes beam elements, nonlinear impact springs which have gaps in upper and lower positions, and hydrodynamical couplings which simulate the fluid-filled cylinders of reactor vessel and core barrel structures is established. And for the exciting external force the response spectrum which is applied to reactor support is converted to the time history input. With this excitation and the model the dynamic behaviour of reactor internals is obtained. As the results, the structural integrity of reactor internal components under seismic excitation is verified and the input for the detailed duel assembly series model could be obtained. And the simplicity and effectiveness of Global Beam Model and the economics of the explicit Runge-Kutta-Gills algorithm in impact problem of high frequency interface components are confirmed.

  • PDF

Thinning Intensity Effects on Carbon Storage of Soil, Forest Floor and Coarse Woody Debris in Pinus densiflora Stands (간벌 강도가 소나무림의 토양, 낙엽층 및 고사목 탄소 저장량에 미치는 영향)

  • Ko, Suin;Yoon, Tae Kyung;Kim, Seongjun;Kim, Choonsig;Lee, Sang-Tae;Seo, Kyung Won;Son, Yowhan
    • Journal of Korean Society of Forest Science
    • /
    • v.103 no.1
    • /
    • pp.30-36
    • /
    • 2014
  • This study examined the change in carbon (C) storage of soil, forest floor and coarse woody debris (CWD) for different thinning intensities in Pinus densiflora stands 4 years after the treatment. Two study stands were located in Jeongseon (Stand 1) and Gwangneung Experiment Forest (Stand 2). Three plots for different thinning intensities based on stand density were established at each stand in 2008; control plot (0%), T20 plot (20%) and T30 plot (30%) in Stand 1 and control plot (0%), T39 plot (39%) and T74 plot (74%) in Stand 2, respectively. The C storage of soil (0-50 cm), forest floor and CWD was measured in 2012. Total C storage of T30 plot ($109.80t{\cdot}C{\cdot}ha^{-1}$) was significantly higher than that of control plot ($86.69t{\cdot}C{\cdot}ha^{-1}$) in Stand 1. In stand 2, total C storage of T74 plot ($97.02t{\cdot}C{\cdot}ha^{-1}$) was significantly higher than that of control plot ($72.04t{\cdot}C{\cdot}ha^{-1}$) and T39 plot ($63.25t{\cdot}C{\cdot}ha^{-1}$). Total C storage of the heaviest thinned plot was the highest in each study stand. Since this study examined initial effects of thinning on C storage of soil, forest floor and CWD, further studies would be necessary to evaluate the long-term effects.

A Prediction of N-value Using Artificial Neural Network (인공신경망을 이용한 N치 예측)

  • Kim, Kwang Myung;Park, Hyoung June;Goo, Tae Hun;Kim, Hyung Chan
    • The Journal of Engineering Geology
    • /
    • v.30 no.4
    • /
    • pp.457-468
    • /
    • 2020
  • Problems arising during pile design works for plant construction, civil and architecture work are mostly come from uncertainty of geotechnical characteristics. In particular, obtaining the N-value measured through the Standard Penetration Test (SPT) is the most important data. However, it is difficult to obtain N-value by drilling investigation throughout the all target area. There are many constraints such as licensing, time, cost, equipment access and residential complaints etc. it is impossible to obtain geotechnical characteristics through drilling investigation within a short bidding period in overseas. The geotechnical characteristics at non-drilling investigation points are usually determined by the engineer's empirical judgment, which can leads to errors in pile design and quantity calculation causing construction delay and cost increase. It would be possible to overcome this problem if N-value could be predicted at the non-drilling investigation points using limited minimum drilling investigation data. This study was conducted to predicted the N-value using an Artificial Neural Network (ANN) which one of the Artificial intelligence (AI) method. An Artificial Neural Network treats a limited amount of geotechnical characteristics as a biological logic process, providing more reliable results for input variables. The purpose of this study is to predict N-value at the non-drilling investigation points through patterns which is studied by multi-layer perceptron and error back-propagation algorithms using the minimum geotechnical data. It has been reviewed the reliability of the values that predicted by AI method compared to the measured values, and we were able to confirm the high reliability as a result. To solving geotechnical uncertainty, we will perform sensitivity analysis of input variables to increase learning effect in next steps and it may need some technical update of program. We hope that our study will be helpful to design works in the future.

Smart Electric Mobility Operating System Integrated with Off-Grid Solar Power Plants in Tanzania: Vision and Trial Run (탄자니아의 태양광 발전소와 통합된 전기 모빌리티 운영 시스템 : 비전과 시범운행)

  • Rhee, Hyop-Seung;Im, Hyuck-Soon;Manongi, Frank Andrew;Shin, Young-In;Song, Ho-Won;Jung, Woo-Kyun;Ahn, Sung-Hoon
    • Journal of Appropriate Technology
    • /
    • v.7 no.2
    • /
    • pp.127-135
    • /
    • 2021
  • To respond to the threat of global warming, countries around the world are promoting the spread of renewable energy and reduction of carbon emissions. In accordance with the United Nation's Sustainable Development Goal to combat climate change and its impacts, global automakers are pushing for a full transition to electric vehicles within the next 10 years. Electric vehicles can be a useful means for reducing carbon emissions, but in order to reduce carbon generated in the stage of producing electricity for charging, a power generation system using eco-friendly renewable energy is required. In this study, we propose a smart electric mobility operating system integrated with off-grid solar power plants established in Tanzania, Africa. By applying smart monitoring and communication functions based on Arduino-based computing devices, information such as remaining battery capacity, battery status, location, speed, altitude, and road conditions of an electric vehicle or electric motorcycle is monitored. In addition, we present a scenario that communicates with the surrounding independent solar power plant infrastructure to predict the drivable distance and optimize the charging schedule and route to the destination. The feasibility of the proposed system was verified through test runs of electric motorcycles. In considering local environmental characteristics in Tanzania for the operation of the electric mobility system, factors such as eco-friendliness, economic feasibility, ease of operation, and compatibility should be weighed. The smart electric mobility operating system proposed in this study can be an important basis for implementing the SDGs' climate change response.

Development of heat exchanger for underground water heat. II - Design and manufacture for heat exchanger of underground water - (지하수 이용을 위한 열교환기 개발. II - 지하수이용 냉·난방기 설계제작 -)

  • Lee, W.Y.;Ahn, D.H.;Kim, S.C.;Park, W.P.;Kang, Y.G.;Kim, S.B.
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.4 no.1
    • /
    • pp.128-137
    • /
    • 2002
  • This study was conducted to develop the heat exchanger by utilizing the heat energy of underground water(15℃), which might be used for cooling and heating system of the agricultural facilities. We developed the heat exchanger by using the parallel type plat fin tube made of Aluminum(Al 6063), which was named Aloo-Heat(No. 0247164, offered by Korean Intellectual property Office). The trial manufactures were made from Aloo-heat which was 600mm, 700mm length respectively, and It were welded to the end "U" type in order to direct flow of the underground water. The performance test was carried out under the condition of open space and room temperature with the change of flow rate of the underground water and air. The results are as follows. 1. The trial manufactures had convection heat value from 33 to 156 W/m2℃, and It was coincided with design assumption. 2. The amount of energy transfer was increased with the increment of the area of heat transfer, the air flow, the gap of temperature inlet & outlet the underground water and the air. 3. The heat value was 6,825W when the air flow was 6,000m3/h and the gap of temperature between inlet and outlet of the underground water was 6℃, and It dropped from 25.8℃ to 23.2℃(-2.6℃ difference). The convection heat value was 88.5W/m2℃. 4. The heat value was 2.625W when the air flow was 4,000m3/h and the gap of temperature between inlet and outlet the underground water was 2℃, and It dropped from 27℃ to 22.5℃(-4.5℃ difference). The convection heat value was 33.6W/m2℃. 5. Correlation values(R2) of the testing heat values of the trial manufacture type I, II, and III were 0.9141, 0.8935, and 0.9323 respectively, and correlation values(R2) of the amount of the air flow 6,000m3/h, 5,000m3/h, 4,000m3/h were 0.9513, 0.9414, and 0.9003 respectively.

A study on the field tests and development of quantitative two-dimensional numerical analysis method for evaluation of effects of umbrella arch method (UAM 효과 평가를 위한 현장실험 및 정량적 2차원 수치해석기법 개발에 관한 연구)

  • Kim, Dae-Young;Lee, Hong-Sung;Chun, Byung-Sik;Jung, Jong-Ju
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.11 no.1
    • /
    • pp.57-70
    • /
    • 2009
  • Considerable advance has been made on research on effect of steel pipe Umbrella Arch Method (UAM) and mechanical reinforcement mechanism through numerical analyses and experiments. Due to long analysis time of three-dimensional analysis and its complexity, un-quantitative two-dimensional analysis is dominantly used in the design and application, where equivalent material properties of UAM reinforced area and ground are used, For this reason, development of reasonable, theoretical, quantitative and easy to use design and analysis method is required. In this study, both field UAM tests and laboratory tests were performed in the residual soil to highly weathered rock; field tests to observe the range of reinforcement, and laboratory tests to investigate the change of material properties between prior to and after UAM reinforcement. It has been observed that the increase in material property of neighboring ground is negligible, and that only stiffness of steel pipe and cement column formed inside the steel pipe and the gap between steel pipe and borehole contributes to ground reinforcement. Based on these results and concept of Convergence Confinement Method (CCM), two dimensional axisymmetric analyses have been performed to obtain the longitudinal displacement profile (LDP) corresponding to arching effect of tunnel face, UAM effect and effect of supports. In addition, modified load distribution method in two dimensional plane-strain analysis has been suggested, in which effect of UAM is transformed to internal pressure and modified load distribution ratios are suggested. Comparison between the modified method and conventional method shows that larger displacement occur in the conventional method than that in the modified method although it may be different depending on ground condition, depth and size of tunnel, types of steel pipe and initial stress state. Consequently, it can be concluded that the effect of UAM as a beam in a longitudinal direction is not considered properly in the conventional method.

Feed Value of the Different Plant Parts of Main Forage Rice Varieties (사료용 벼 주요 품종의 수확부위 별 사료가치)

  • Ahn, Eok-Keun;Won, Yong-Jae;Kang, Kyung-Ho;Park, Hyang-Mi;Jung, Kuk-Hyun;Hyun, Ung-Jo;Lee, Yoon-Sung
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.67 no.1
    • /
    • pp.1-8
    • /
    • 2022
  • In order to manufacture feed suitable for consumer use and provide feed value information, we analyzed the feed components of the four main forage rice varieties by plant parts harvested 30 days after heading. The contents of the six feed ingredients were significantly different (p<0.05) among harvested parts. In the panicle, the crude protein (CP) (6.97%) and lignin (3.11%) were the highest, while the crude ash (CA) and neutral detergent fiber (NDF) contents were significantly lower, resulting in a total digestible nutrient (TDN) content of 77.29%, which is higher than that of the stem (64.82%) and leaf blade and sheath (LBS) (63.57%) (p<0.05). In contrast, the content of crude fat (CF) did not differ significantly among parts (p<0.05). In panicles from 'Jonong', 'Nokyang' and 'Yeongwoo', the TDN content of each cultivar was 78.48-79.07%, with no significant difference among the varieties. In 'Mogwoo' (Mw), the CP content was 8.70%, which was much higher than that of other varieties (p<0.05). In particular, the Mw TDN content was slightly lower in the panicle (72.95%) but higher in the stem (75.37%) and LBS (66.49%) than in the other varieties. The CA, NDF, acid detergent fiber (ADF), and lignin contents were also very low compared to other varieties; therefore, the feed value of the stem and LBS was excellent. In addition, the total dry matter weight (DMW) was 123 g per hill, which was much higher than 82-105 g per hill for other varieties. The distribution of DMW by part was LBS (56.9 g), stem (36.8 g), and panicle (29.3 g), and because the parts, except the panicles, were much higher than the 43-57% of other varieties (grain straw ratio: 76%), rice straw is advantageous in terms of quantity and feed value when used as forage on farms. The relative feed value (RFV) of the four cultivars ranged from 86.79-403.74 across all parts, and hay of grade 3 or higher with an RFV of 100 or more increased with delayed heading in both stems and LBS. This is due to the accumulation of starch into grains during ripening, which supports the observation that the RFV of the early flowering 'Jonong' and 'Nokyang' panicles increased.