• Title/Summary/Keyword: 시험비용

Search Result 1,090, Processing Time 0.028 seconds

Determinants Affecting Organizational Open Source Software Switch and the Moderating Effects of Managers' Willingness to Secure SW Competitiveness (조직의 오픈소스 소프트웨어 전환에 영향을 미치는 요인과 관리자의 SW 경쟁력 확보의지의 조절효과)

  • Sanghyun Kim;Hyunsun Park
    • Information Systems Review
    • /
    • v.21 no.4
    • /
    • pp.99-123
    • /
    • 2019
  • The software industry is a high value-added industry in the knowledge information age, and its importance is growing as it not only plays a key role in knowledge creation and utilization, but also secures global competitiveness. Among various SW available in today's business environment, Open Source Software(OSS) is rapidly expanding its activity area by not only leading software development, but also integrating with new information technology. Therefore, the purpose of this research is to empirically examine and analyze the effect of factors on the switching behavior to OSS. To accomplish the study's purpose, we suggest the research model based on "Push-Pull-Mooring" framework. This study empirically examines the two categories of antecedents for switching behavior toward OSS. The survey was conducted to employees at various firms that already switched OSS. A total of 268 responses were collected and analyzed by using the structural equational modeling. The results of this study are as follows; first, continuous maintenance cost, vender dependency, functional indifference, and SW resource inefficiency are significantly related to switch to OSS. Second, network-oriented support, testability and strategic flexibility are significantly related to switch to OSS. Finally, the results show that willingness to secures SW competitiveness has a moderating effect on the relationships between push factors and pull factor with exception of improved knowledge, and switch to OSS. The results of this study will contribute to fields related to OSS both theoretically and practically.

Individual Bioequivalence Tests under 3 X 2 Design (3 X 2 교차설계법에서 개인 생물학적 동등성 검정)

  • Jung, Gyu-Jin;Lim, Nam-Kyoo;Park, Sang-Gue
    • The Korean Journal of Applied Statistics
    • /
    • v.23 no.1
    • /
    • pp.139-150
    • /
    • 2010
  • In recent years, more generic drug products became available. The current regulation for assessing the bioequivalence of two drug formulations is based on the concept of average bioequivalence. This approach has been indicated to be insufficient for assessing switchability between two drug formulations and US FDA has adopted individual bioequivalence as one of the bioequivalence criterion since 2001. The US FDA recommends that individual bioequivalence be assessed based on $2\;{\times}\;4$ crossover design, while a $2\;{\times}\;3$ crossover design may be used as an alternative design to reduce the length and cost of the study. In this paper, a statistical procedure for assessment of individual bioequivalence under $3\;{\times}\;2$ crossover designs is proposed and some statistical points are discussed with $2\;{\times}\;3$ crossover design and $2\;{\times}\;3$ extra-reference design through simulation studies.

A Design and Implementation of Process Controller for BMW (Bacteria Mineral Water) Plant (비엠 활성수 플랜트의 공정제어기 설계 및 구현)

  • Lee, Sang-Yun
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.16 no.2
    • /
    • pp.74-82
    • /
    • 2015
  • In this study, a BMW plant process control system model which produces BMW is suggested and the BMW plant process controller with the following functions is developed. The first function is to operate the electronic overload relays to stop the blower for a certain period of time and to re-operate it again when the blower is overloaded. The second function is to close the motor operated valve automatically in case of power failure to prevent the circulation from the guided tank to the compost throwing tank and to block leak from the compost throwing tank due to the failure of ball valve. The third function is to transfer produced BMW from the concentration tank to 4 storage tanks for automatic managing of the BMW output. A device to measure the signal of the BMW plant process controller and a test equipment are developed. The designed BMW plant process controller is checked to see if it operates correctly according to the design specifications. The sequence control method based on BMW plant process controller is developed at a low cost in this study, so it is expected to bring improvements in the stability and the efficiency of system and to cause reductions in the operation and the management costs in the future.

Development and Application of Cone Penetrometer with Impact Penetration Rod for Evaluation of Track Substructure (철도궤도 하부구조물 평가를 위한 타격식 관입 롯드가 체결된 콘 관입기의 개발 및 적용)

  • Hong, Wontaek;Byun, Yonghoon;Kim, Sangyeob;Choi, Chanyong;Lee, Jongsub
    • Journal of the Korean GEO-environmental Society
    • /
    • v.16 no.2
    • /
    • pp.45-52
    • /
    • 2015
  • To minimize the cost of maintenance, repair and over-design of track substructure, an accurate evaluation of strength and stiffness of the track substructure is necessary. In this study, a cone penetrometer with impact penetration rod (CPI) is developed for the evaluation of track substructure. For applicability test, the chamber and field tests were performed. As the experimental results of the CPI, dynamic cone penetration endex (DCPI), cone tip resistance ($q_c$), friction resistance ($f_s$) and friction ratio (Fr) were obtained. In the chamber test, the experimental results show reasonable values for the simulated track substructure. In the field test, the CPI clearly detects the interface between the ballast and the subgrade. Also, discontinuous layers are detected in the subgrade. It is expected that the developed CPI may be an effective tool for the evaluation of track substructure by evaluating the ballast layer by dynamic penetration and the subgrade by static penetration of the inner rod.

Improvement and Effectiveness for Chemical Control Protocol of Sweet Persimmon Anthracnose Disease (단감 탄저병 방제법 개선을 위한 살균제 선발 및 효과)

  • Jeon, Chang Wook;Kwon, Youngho;Lee, Jung Han;Kwak, Youn-Sig
    • The Korean Journal of Pesticide Science
    • /
    • v.19 no.3
    • /
    • pp.312-316
    • /
    • 2015
  • Anthracnose, caused by Colletotrichum spp. is the most important and devastating disease in sweet persimmon production in worldwide. There is no alternative control method or resistant cultivar is available. Therefore, chemical controls are widely accepted to control the disease. Three fungicides among 16 fungicides have been selected to apply in field condition. The selected three fungicides (metconazole, dithianon and propineb) showed lower EC50 and reliable control effect in both in vitro and in vivo. According to general guide line of anthracnose disease control method recommended 8 times spay of the fungicide. In this study, we performed 8, 4, and 2 times spay of the fungicides. For 8 times application, practice spray machine has been used and for 4 and 2 time application, a recently invented spray machine was input. The fungicides have been treated from middle of June to end of August in 2014 year. Control effect of among the selected fungicides showed similar result regardless of sort of the fungicide. However, frequency of spray result showed significantly different results, 8 and 4 times fungicide application showed low and similar disease occurrence, but 2 times application showed intermediated disease occurrence between 4 times treatment and untreated control. Taken together, result showed that 4 times application with effective fungicide, mechanically advanced tool can reduced the anthracnose disease damage in sweet persimmon production.

Development of Land Fill Gas(LFG)-MGT Power Generation and Green House Design Technology (쓰레기 매립지 MGT 발전 및 유리온실 설계기술개발)

  • Hur, Kwang-Beom;Park, Jung-Keuk;Lee, Jung-Bin
    • Journal of Energy Engineering
    • /
    • v.20 no.1
    • /
    • pp.13-20
    • /
    • 2011
  • The high fuel flexibility of Micro Gas Turbine(MGT) has boosted their use in a wide variety of applications. Recently, the demand for biogas generated from the digestion of organic wastes and landfill as a fuel for gas turbines has increased. We researched the influence of firing landfill gas(LFG) on the performance and operating characteristics of a micro gas turbine combined heat and power system. $CH_4$ and $CO_2$ simultaneous recovery process has been developed for field plant scale to provide an isothermal, low operating cost method for carrying out the contaminants removal in Land Fill Gas(LFG) by liquid phase catalyst for introduce into the green house for the purpose of $CO_2$ rich cultivation of the plants. Methane purification and carbon dioxide stripping by muti panel autocirculation bubble lift column reactor utilizing Fe-EDTA was conducted for evaluate optimum conditions for land fill gas. Based on inflow rate of LFG as 0.207 $m^3$/min, 5.5 kg/$cm^2$, we designed reactor system for 70% $CH_4$ and 27% $CO_2$ gas introduce into MGT system with $H_2S$ 99% removal efficiency. A green house designed for four different carbon dioxide concentration from ambient air to 1500 ppm by utilizing the exhaust gas and hot water from MGT system.

Performance Improvement of an Air Source Heat Pump by Storage of Surplus Solar Energy in Greenhouse (온실 내 잉여 태양열을 이용한 공기열원 히트펌프 성능향상)

  • Kwon, Jin Kyung;Kang, Geum Chun;Moon, Jong Pil;Kang, Youn Ku;Kim, Chung Kil;Lee, Su Jang
    • Journal of Bio-Environment Control
    • /
    • v.22 no.4
    • /
    • pp.328-334
    • /
    • 2013
  • A greenhouse heating system to improve heat pump performance using inside and outside air of greenhouse as a heat source selectively and cut $CO_2$ enrichment costs by delay of greenhouse ventilation was developed. In this system, thermal storage modes divided into inside circulation mode using surplus solar energy and outside circulation mode using outside air heat. The thermal storage modes were designed to be switched mutually according to inside greenhouse temperature and six temperature values were input to control the heat pump operating, thermal storage mode switching and greenhouse heating automatically. Operating characteristics of this system were tested in a plastic greenhouse of non-ventilation condition. The results of test showed that the inside circulation mode began at about 11:00 and lasted for about 210 minutes and inside greenhouse temperature was maintained between $20{\sim}28^{\circ}C$ in spite of non-ventilation. System heating COP of the inside circulation mode in the daytime was 3.35, which was 36% and 25% higher than that of the outside circulation modes in the nighttime and daytime respectively.

Performance Analysis of a 3 Pressured Combined Cycle Power Plant (3압 복합 발전 플랜트 사이클에 대한 성능해석)

  • Kim, S. Y.;K. S. Oh;Park, B. C.
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.2 no.2
    • /
    • pp.74-82
    • /
    • 1998
  • Combined cycle power plant is a system where a gas turbine or a steam turbine is used to produce shaft power to drive a generator for producing electrical power and the steam from the HRSG is expanded in a steam turbine for additional shaft power. The temperature of the exhaust gases from a gas turbine ranges from $400{\sim}650^{\circ}C$, and can be used effectively in a heat recovery steam generator to produce steam. Combined cycle can be classed as a topping and bottoming cycle. The first cycle, to which most of the heat is supplied, is a Brayton gas turbine cycle. The wasted heat it produces is then utilized in a second process which operates at a lower temperature level is a steam turbine cycle. The combined gas and steam turbine power plant have been widely accepted because, first, each separate system has already proven themselves in power plants as an independent cycle, therefore, the development costs are low. Secondly, using the air as a working medium, the operation is relatively non- problematic and inexpensive and can be used in gas turbines at an elevated temperature level over $1000^{\circ}C$. The steam process uses water, which is likewise inexpensive and widely available, but better suited for the medium and low temperature ranges. It therefore, is quite reasonable to use the steam process for the bottoming cycle. Recently gas turbine attained inlet temperature that make it possible to design a highly efficient combined cycle. In the present study, performance analysis of a 3 pressured combined cycle power plant is carried out to investigate the influence of topping cycle to combined cycle performance. Present calculation is compared with acceptance performance test data from SeoInchon combined cycle power plant. Present results is expected to shed some light to design and manufacture 150~200MW class heavy duty gas turbine whose conceptual design is already being undertaken.

  • PDF

Reduction of Organic Sludge using High Efficiency Aeration System(HEAS) (고효율 포기 시스템을 이용한 유기성 슬러지의 감량화)

  • Oh, Sea-Bae;Lee, Sang-Houck
    • Journal of Digital Convergence
    • /
    • v.10 no.10
    • /
    • pp.221-227
    • /
    • 2012
  • In Korea, ocean dumping has been widely used as the ultimate disposal of sewage sludge. However, ocean dumping of food wasted and sewage sludge from 2013 is expected to legally restricted as London convention on marine pollution prevention has been effective in 2009. This research aims to examine the effect of HEAS in treating the environmental pollution load caused by organic high concentrated sludge. Thus, onsite laboratory scale treatability test using HEAS was adopted to treat the high concentrated organic sludge from sewage and industrial wastewater treatment plant. The research results showed that the HEAS is useful to reduce the environmental pollution caused by organic high concentrated sludge. Specific results are as follows. 1. The organic removal after the sludge digestion using the high efficiency aeration system was 55.2-85.8%. Although these results were lower than those from the general sewage treatment, the high efficiency aeration system could be evaluated as efficient, considering the object sludge contained the industrial waster water. 2. The average removal efficiency was about 25.2%. 3. It was revealed that sludge digestion by the high efficiency aeration system could effectively contribute to the sludge treatment cost. Especially, the high efficiency aeration system is more applicable to the onsite treatment of small sewage and wastewater treatment plant that contains high solid content sludge, industrial wastewater sludge, high fixed solid sludge.

Application of Screenings by-product of Crushing Rock in Quarry as Lean Concrete Pavement (산업부산물인 스크리닝스의 활용도 증진을 위한 린콘크리트 적용성 평가)

  • Kang, Min-Soo;Lee, Kyung-Ha;Suh, Young-Chan;Kim, In-Soo
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.6 no.4
    • /
    • pp.75-81
    • /
    • 2012
  • In case of crushing rock to produce materials for lean concrete subbase layer in concrete pavement, natural sand is used for the gradation adjustment of aggregates, and the percentage of natural sand used is 30%~40% of the weight ratio of aggregate mix. The supply of natural sand that is used in lean concrete as a fine aggregate is getting harder due to the current of exhaustion of source, and the cost for the purchase of natural sand is included in the cost of roadway construction. This study, therefore, was conducted in order to resolve the exhaustion of materials and economize in construction expenditure by the application of screenings, which is by-product of crushing rock in quarry, as an alternative to natural sand. As a result of a comparative analysis on the application of screenings and natural sand with typical types of rock that is produced in domestic, which was conducted in the first year, It is found out that the use of screenings as a fine aggregate showed better unconfined compression strength. Verification of actual application of screenings was conducted in the second year, after test construction and follow-up investigation. The compressive strength, compaction density, settlement of screenings applied case was higher than that of natural sand. Thus, it is expected that application of screenings to construction in field will contribute to the cost saving, material recycling and the protection of environment.

  • PDF