• Title/Summary/Keyword: 시험비용

Search Result 1,090, Processing Time 0.026 seconds

Development of Coolant Flow Simulation System for Nuclear Fuel Test Rigs (핵연료조사리그 냉각수 유동 모의장치 개발)

  • Hong, Jintae;Joung, Chang-Young;Heo, Sung-Ho;Kim, Ka-Hye
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.1
    • /
    • pp.117-123
    • /
    • 2015
  • To remove heat generated during a burn-up test of nuclear fuels, the heat generation rate of nuclear fuels should be calculated accurately, and a coolant should be circulated in the test loop at an adequate flow rate. HANARO is an open pool-type reactor with an independent test loop for the burn-up test of nuclear fuels. A test rig is installed in the test loop, and a coolant is circulated through the test loop to maintain the temperature of the nuclear fuel rods within a desired temperature during an irradiation test. The components and sensors in the test rig can be broken or malfunction owing to the flow-induced vibration. In this study, a coolant flow simulation system was developed to verify and confirm the soundness of components and sensors assembled in the test rig with a high flow rate of the coolant.

The Development of Low Cost Power Components Measurement and Record System for Monitoring Electrical Equipment Operation Status (전력설비 동작 상태 감시를 위한 저가형 전력 성분 측정 및 기록 시스템의 개발)

  • Jeon, Jeong-Chay;Oh, Hun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.7
    • /
    • pp.4855-4862
    • /
    • 2015
  • This paper proposes low price power component measurement and record system for preventing electrical safety accident and supporting accident cause analysis by periodically monitoring and recording the operation status of electrical equipments. The proposed system was designed by mainly using parts to measure accurate power component but reduce cost. Especially, low cost and high effectiveness system implementation was possible by using MAXIM 78M6631 to calculate power components in the definition of IEEE Standard 1459-2010 related power quality. The measurement performance of the developed system is tested by using standard devices such as YOKOGAWA power analyzer WT1600. The test results showed that accuracy of the developed system is less than 0.5 % and the developed system is tested in a real area to verify the operation reliability and remote monitoring performance of the system over 6 months.

Analysis of Detection Ability Impact of Clang Static Analysis Tool by Source Code Obfuscation Technique (소스 코드 난독화 기법에 의한 Clang 정적 분석 도구의 성능 영향 분석)

  • Jin, Hongjoo;Park, Moon Chan;Lee, Dong Hoon
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.28 no.3
    • /
    • pp.605-615
    • /
    • 2018
  • Due to the rapid growth of the Internet of Things market, the use of the C/C++ language, which is the most widely used language in embedded systems, is also increasing. To improve the quality of code in the C/C++ language and reduce development costs, it is better to use static analysis, a software verification technique that can be performed in the first half of the software development life cycle. Many programs use static analysis to verify software safety and many static analysis tools are being used and studied. In this paper, we use Clang static analysis tool to check security weakness detection performance of verified test code. In addition, we compared the static analysis results of the test codes applied with the source obfuscation techniques, layout obfuscation, data obfuscation, and control flow obfuscation techniques, and the static analysis results of the original test codes, Analyze the detection ability impact of the Clang static analysis tool.

Measurement of Physical Properties of Pepper for Particle Behavior analysis of sorting system for Pepper Harvester (고추수확기용 선별장치의 입자 거동 해석을 위한 고추 물성측정)

  • Byun, Jun Hee;Kim, Su Bin;Kim, Myoung Ho;Kim, Dae Cheol
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.9-9
    • /
    • 2017
  • 입자거동해석소프트웨어(EDEM)은 DEM(Discrete Element Method)기법을 이용한 입자 거동 전용 해석툴로 입자 유입량, 위치 등을 조절하여 입자거동과 관련된 제품 개발, 프로세스 최적화를 위한 비용 및 시간 절감에 활용도가 뛰어난 소프트웨어이다. EDEM을 활용하기 위해선 적용대상에 대한 물성치를 적용하여야 한다. 따라서 본 연구에서는 EDEM를 이용하여 현재 연구개발 중인 카드클리너 방식의 고추 선별기의 성능을 분석을 수행하기 위해 고추 물성측정 실험을 수행 하였다. EDEM을 이용한 입자거동해석에 필요한 개인 물성치에는 포아송비, 전단탄성계수, 밀도가 있다. 또한 입자-입자, 입자-Geometry 간의 상호관계를 위한 물성치인 반발계수, 정지마찰계수, 구름마찰계수가 필요하다. 공시 시료인 고추는 광주광역시 남구 승촌동 소재의 개인농가 Plastic 온실로 재배된 '천상'품종을 사용하였다. 푸아송 비와, 전단 탄성계수를 측정하기 위한 인장시험기기로는 만능인장시험기(TA-XT2, Stable Micro, 영국)를 이용하였으며, 인장에 의한 고추의 변형량 축정은 초고속카메라(NX4-SI, IDT, 미국)을 이용하였다. 밀도는 비중병법에 기초하여 질량과 부피를 측정하여 밀도를 계산하였다. 반발계수는 고추의 충돌 실험을 통해 변화한 높이를 이용하여 계산하였고, 충동 실험을 통해 변화한 높이는 초고속카메라를 이용하여 측정하였다. 정지마찰계수와 구름마찰계수는 고추의 미끄러짐이 시작하는 각도와 등속도 운동으로 구르는 각도를 초고속카메라를 이용하여 측정 후 계산하였다. 모든 실험은 3번 반복을 통해 평균값을 시험 결과 값으로 이용하였다. 고추의 대한 물성치 실험결과 고추의 푸아송 비는 0.294(std : 0.2), 전단탄성계수 4.624E+06 Pa, 밀도 $600kg/m^3$로 나타났다. 또한 입자-입자 간의 물성치인 반발계수는 0.383, 정지마찰계수는 0.455, 구름마찰 계수는 0.043로 나타났다. 추후 본 연구에서 측정한 고추의 물성치를 적용한 EDEM 입자거동해석 시뮬레이션을 통해 카드클리너 방식의 고추 선별기의 성능에 대한 분석을 하고자 한다.

  • PDF

A Study on the Water Absorption Test of Generator Stator Windings Using Probability Distributions (여러 가지 확률분포를 이용한 발전기 고정자 권선의 흡습 시험에 관한 연구)

  • Kim, Hee-Soo;Bae, Y.C.;Kim, Hee-Jeong;Na, Myung-Hwan
    • The Korean Journal of Applied Statistics
    • /
    • v.22 no.5
    • /
    • pp.961-969
    • /
    • 2009
  • Water absorption in water-cooled generator stator windings can cause serious accidents such as insulation breakdown and it brings a generator to the unexpected sudden outage. Accordingly, it is important to diagnose the water absorption of them in the effective operation of power plant. Especially, the capacitance value which is measured for diagnosis is very small so the special diagnosis methods like stochastic theory are needed. KEPRI developed the water absorption test equipment and diagnosis technology for them. In this paper we propose that water absorption test of generator stator windings using probability distributions. The proposed diagnosis technology is applied to the real system and the results of water absorption test for stator windings are agreed to them of water leak test.

Effect of the Design Parameters Change on the Hybrid Dynamometer Braking Performance (혼성동력계에서 주요 설계변수가 제동성능에 미치는 효과분석)

  • Lee, Jong-Hoon;Hwang, Jai-Hyuk;Jeong, Min-Ji;Kwon, Jun-Yong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.11
    • /
    • pp.981-988
    • /
    • 2016
  • Dynamometer is a device for testing the performance of the brake and it is composed of a test zone, the mechanical inertia zone, the electric motor and the control zone. Hybrid dynamometer is a way to compensate for the loss of mechanical inertia in accordance with the brake operation by using an electric motor to reduce the size of the mechanical inertia with the advantage that can be tested in the relatively small size of the mechanical inertia and low cost. In this paper, design the proper size of hybrid dynamometer in the laboratory level with the space constraints, analysed the effect of critical parameter on the braking performance of hybrid dynamometer such as changing the friction coefficient. With this study, could get the results of guideline to judge the poor friction material by measuring the torque of the electric motor to compensate the energy loss due to a reduced mechanical inertia.

Assessment of Geosynthetic Soilbag Method to Restore the Roadbed of Railway (철도노반 복구를 위한 토목섬유 Soilbag 공법의 적용성 평가)

  • Hwang, Seon-Keun;Koh, Tae-Hoon;Park, Sung-Hyun
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.4 no.1 s.12
    • /
    • pp.65-75
    • /
    • 2004
  • Roadbed failure due to the natural disaster may bring out social and economic damage such as the loss of life and property, the consumption of time and cost for recovery, and the delay of logistics in railway In this study, the method using geosynthetic soilbag was applied to rehabilitation of the railway roadbed which was failed by disaster. The full scale tests with the simulated train loading were performed in order to evaluate the static and dynamic performance at the railway roadbed using geosynthetic soilbag. The results of these tests were compared with unreinforced and reinforced cases with geosynthetic soilbag, respectively The data gathered by various measurement devices from these full scale tests would be useful to evaluate and understand the roadbed with geosynthetic soilbag. In conclusion, geosynthetic soilbag was evaluated as a permanent restoration method to reinforce the roadbed of railway.

Effect of N-K Compound Fertilizer Top Dressing of Paddy (수도(水稻)에 대(對)한 질소(窒素), 가리(加里) 복비추비(複肥追肥) 효과시험(效果試驗))

  • Oh, Wang-Keun;Rhee, Kang-Man;Kim, Woo-Jin
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.12 no.3
    • /
    • pp.133-139
    • /
    • 1979
  • In order to evaluate the effect of developed Nk compound fertilizers, 17-0-17 granular and powder, and 17-0-14 granules in comparison with single fertilizers, urea and potassium on rice (Oryzae sativa) ; cultivar, Milyang 23, (Orizae Sativa), a field experiment was carried out. Results obtained are as follows : 1. The top dressing of NK compound fertilizers tended to produce higher paddy yield than that of single fertilizers; urea and patasstum muriate. 2. The absorption of potassium and nitrogen by rice plant from the plot of NK granular compound fertilizer, 17-0-17, was greater than from the plots the absorption of those elements received other types of ferilizers and application method The absorded K/Ca+Mg ratio in milli equivalent basis in plant was also appeared to be in same order as the absorption of nitrogen and potassium. 3. From the results of present study it seemed necessary to evaluate the NK compound fertilizer for the top dressing at effective tillering stage of rice as well.

  • PDF

Development of a Comprehensive Performance Test Facility for Small Millimeter-wave Tracking Radar (소형 추적 레이다용 종합성능시험 시설 개발)

  • Kim, Hong-Rak;Kim, Youn-Jin;Woo, Seon-Keol;An, Se-Hwan
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.3
    • /
    • pp.121-127
    • /
    • 2020
  • The small tracking radar targets the target in a real-time, fast-moving, fast-moving target against aircraft with a large RCS that is maneuvering at low speed and a small RCS aircraft maneuvering at high speed (fighters, drones, helicopters, etc.) It is a pulsed radar that detects and tracks. Performing a performance test on a tracking radar in a real environment is expensive, and it is difficult to quantitatively measure performance in a real environment. Describes the composition of the laboratory environment's comprehensive performance test facility and the main requirements and implementation of each configuration.Anechoic chambers to simulate the room environment, simulation target generator to simulate the signal of the room target, target It is composed of a horn antenna driving device to simulate the movement of a vehicle and a Flight Motion Simulatior (FMS) to simulate the flight environment of a tracking radar, and each design and implementation has been described.

A Study on the Reliability Evaluation System for O-ring of Semiconductor Equipments (반도체장비용 오링의 종합 신뢰성 평가기술에 관한 연구)

  • 김동수;김광영;최병오;박화영
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.613-617
    • /
    • 2001
  • The test items like as endurance, air leakage and oil endurance test is requested for reliability evaluation about O-ring which is a kind of core machinery accessories of semi-conduct manufacturing equipment. For verification of these, we design and manufactured a test system for endurance, air leakage and oil endurance of O-ring for semi-conduct manufacturing equipment, and also performed the test for two kinds of O-ring, as it were Viton and Kalretz. The characteristics of this test equipment consist in realization of the test conditions of semi-conduct manufacturing equipment and satisfying the test method. The test conditions are cut gas, vacuum grade, temperature and revolution numbers in the endurance test system, vacuum grade and temperature in the air leakage test system, temperature and time in the oil endurance test system. The separating test results for wearing which is an oil endurance test item, the wearing index of domestic produced Viton O-ring is higher than foreign product by 2%, wearing rate of Kalretz O-ring better than Viton O-ring by 17%, and particles existed in various place. The test result of air leakage which is measured through the RGA sensor used Helium, the vacuum grade was $10^-3$Torr. And the test result of oil endurance, the volume change rate was 7~15%. Hereafter, we intend to analysis the reliability test evaluation and to utilize for domestic manufacturing companies by establishing data base and developing reliability softwares.

  • PDF