• Title/Summary/Keyword: 시험방식

Search Result 2,098, Processing Time 0.03 seconds

Analysis of Buildability and Strength Characteristics of Cement-based Composite Materials by Manufacturing Method of Laminated Specimens (적층시험체 제작 방식에 따른 시멘트계 복합재료의 적층성능 및 강도 특성 분석)

  • Eun-A Seo;Ho-Jae Lee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.5
    • /
    • pp.9-15
    • /
    • 2023
  • In this study, the lamination performance and strength characteristics of cement-based composite materials according to the laminated specimens manufacturing method were analyzed. As a result of evaluating the buildability according to the layer height, the highest dimensional stability was shown when the layer height was 10 mm in all parts. The mold casting specimen and the printing-Z specimen showed the same compressive strength performance at the age of 28 days. On the other hand, the compressive strength at 28 day of printing-X specimen was the lowest at 71.72 MPa, and 8% lower than that of the mold casting specimen and the printing-Z specimen. The split tensile strength of the laminated specimen may show similar performance to that of the mold casting specimen, but the strength performance may decrease by more than 10% depending on the direction of the layer and the number of layers in the specimen. As a result of the interface analysis of the laminated specimen through X-ray CT analysis, it was confirmed that pores of a certain size were distributed along the interface of the layer.

금융IC카드에 대한 부채널분석 도구 비교 연구

  • Choi, Chan Young;Jeong, Jae Cheol;Shin, Hyu Keun
    • Review of KIISC
    • /
    • v.22 no.8
    • /
    • pp.54-60
    • /
    • 2012
  • 기존 마그네틱 카드의 보안성을 강화하기 위해 집적회로칩이 부착된 IC카드의 사용이 날로 증가하고 있으나 IC카드에 대한 보안 위협 또한 발생하고 있는 실정이다. 그 중에서도 암호화에 사용된 키를 찾기 위해서 암호 알고리즘의 이론적인 취약점이 아닌 암호화 과정에서 누설되는 수행시간, 소비전력, 전자기 방사 등을 이용하는 물리적 공격 방법인 부채널분석 공격이 대표적인 보안 위협이다. 본 논문에서는 부채널분석 공격 기법을 구현한 국내 외 시험 도구의 차이점 및 시험방법의 유효성을 확인하기 위해, 각 도구별 시험 결과를 전력분석 관점에서 비교 분석해 보았다. 시험 결과, 각 도구별 특징을 파악할 수 있었고, 시험 도구의 동작 방식에 다소 차이가 있으나 모두 동일한 결과를 도출해 낼 수 있었다.

Drop Test for the Small Aircraft Main Landing Gear (소형항공기 주착륙장치 낙하시험)

  • Yang, Jin-Yeol;Jung, Seung-Tack;Lee, Seung-Gyu;Lee, Seong-Jin;Kim, Sung-Chan;Song, Jung-Heon
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.12b
    • /
    • pp.635-638
    • /
    • 2011
  • 항공기 착륙 시 발생되는 높은 충격하중에서 승무원 및 기체를 보호하기 위해 높은 충격흡수율이 요구된다. 따라서 착륙 시 발생하는 충격을 효과적으로 흡수할 수 있는 착륙장치는 항공기 핵심 구성요소이다. 다양한 종류의 완충장치가 존재하나, 소형항공기 주착륙장치에는 판스프링 방식을 이용하여 충격에너지를 흡수할 수 있다. 착륙장치의 완충 성능은 반드시 낙하시험을 통해 입증하여야 하며, 이는 미 연방 항공 규정에서 요구하고 있는 사항이다. 이 논문에서는 소형항공기 낙하시험을 위한 설비, 시험 절차 및 낙하시험 수행 결과를 제시한다.

  • PDF

Experimental Study on the Freezing Conditions in a Ice-making Tube Using Flowing Subcooled Water (유동과 냉각수 이용 제빙관의 동결조건에 5관한 실험적 연구)

  • 박영하;현명택;이동원
    • Journal of Energy Engineering
    • /
    • v.9 no.3
    • /
    • pp.178-183
    • /
    • 2000
  • 본 연구에서는 유동과 냉각수를 이용하는 아이슬러리 제조관정을 관찰하고, 이 시스템의 가장 큰 문제점인 관내동결 특성을 파악하였다. 시험수로는 수도수(city water)를 이용하였다. 시스템을 순환하는 시험수가 제빙관내에서 $0^{\circ}C$ 이하의 과냉각 조건이 형성되어 제빙관을 빠져 나오면서 축냉조에 설치된 충격판상에서 과냉각 해소가 일어났다. 이때 유동과냉각수는 내부에너지를 방출하면서 그 일부가 얼음 입자로 상변화되었고, 나머지는 실험장치를 계속순환하였다. 제빙관에서 시험수와 브라인의 열교환 방식을 대향류와 평행류 두 조건에서 시험수의 과냉각도는 Reynolds 수가 증가함에 따라 감소하는 경향을 보였고, 이들 결과 값으로부터 각각의 관계식을 유도하였다. 또한 브라인의 냉각속도가 0.29~0.53[$^{\circ}C$/min] 범위에서 시험수의 과냉각도는 브라인 냉각속도에 종속되지 않았다.

  • PDF

Method of Estimating Pile Load-displacement Curve Using Bi-directional Load Test (양방향 재하시험을 이용한 말뚝의 하중-변위곡선 추정방법)

  • Kwon Oh-Sung;Choi Yong-Kyu;Kwon Oh-Kyun;Kim Myoung-Mo
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.4
    • /
    • pp.11-19
    • /
    • 2006
  • For the last decade, the hi-directional testing method has been advantageous over the conventional pile load testing method in many aspects. However, because the hi-directional test uses a loading mechanism entirely different from that of the conventional pile load testing method, many investigators and practicing engineers have been concerned that the hi-directional test would give inaccurate results, especially about the pile head settlement behavior. Therefore, a hi-directional load test and the conventional top-down load test were executed on 1.5 m diameter cast-in-situ concrete piles at the same time and site. Strain gauges were placed on the piles. The two tests gave similar load transfer curves at various depth of piles. However, the top-down equivalent curve constructed from the hi-directional load test results predicted the pile head settlement under the pile design load to be about one half of that predicted by the conventional top-down load test. To improve the prediction accuracy of the top-down equivalent curve, a simple method that accounts for the pile compression is proposed. It was also shown that the strain gauge measurement data from the hi-directional load test could reproduce almost the same top-down curve.

과하중 방지기의 전기체 구조시험 적용에 관한 연구

  • Kim, Sung-Chan;Chae, Dong-Chul;Kim, Sung-Jun;Hwang, In-Hee
    • Aerospace Engineering and Technology
    • /
    • v.2 no.2
    • /
    • pp.11-17
    • /
    • 2003
  • This paper present a method of meter-out flow control for overload protection valve in full-scale airframe test. Emergency stop, which results in dump state, can be happened during full-scale airframe test by several causes. Because servo valve can't control hydraulics actuator in the dump state, pressure in cylinder chamber may rise abruptly and overload can be acted to the test article. In this paper, the procedure and technology of orifice setting are investigated to protect the test article from unexpected loads by dump. The test results show that the presented methods decrease peak loads and improve unloading characteristics of hydraulic actuators in the dump state.

  • PDF

An Implementation of Test Bed for Linux based IEEE 1394 communication test (리눅스 기반의 IEEE1394 통신 시험을 위한 시험 환경 구축)

  • 이재길
    • Journal of the Korea Society of Computer and Information
    • /
    • v.8 no.3
    • /
    • pp.9-15
    • /
    • 2003
  • IEEE1394 standard supports both isochronous and asynchronous data transmission, thus enabling high-speed data exchange between PC and networked home electronic devices. This paper describes an implementation of Test Bed for Linux based IEEE1394 communication test. In this paper, An integrated Software was developed to test IEEE1394 communication environment. To develop the software, open source software(gscanbus,dvgrab, playdv, Xine, Kino) for the Linux environment was investigated and integrated. It was tested such as the communication among the devices, asynchronous date transmission, isochronous data transmission, and its result was successful. This integrated software has the potential to become efficient test tool for the futher development of networked home electronic devices and multimedia services.

  • PDF

원전고화폐기물 특성시험을 위한 시험법 선정방법

  • Kim, Gi-Hong;Yoo, Yeong-Geol;Hong, Gwon-Pyo;Jeong, Ui-Yeong;Park, Jong-Heon;Kim, Heon
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.06a
    • /
    • pp.219-221
    • /
    • 2004
  • 국가의 규제기관과 처분장에서는 방사성 폐기물의 안전한 영구처분을 위하여 폐기물 수용(인수)기준을 폐기물 발생자에게 준수토록 요구하게 되는데 이러한 폐기물 수용(인수)기준은 처분시설의 가동동안 인간과 환경 보호 그리고 최대 300년간의 제도적 통제기간을 고려하여 처분장의 안전성 확보를 위하여 설정되어진다. 폐기물 수용(인수)기준중 고화체의 안정성 평가와 관련하여 미국(NRC/BTP)은 폐기물의 종류와 고화매질에 따라 유리수, 압축강도, 방사성 조사특성, 미생물 영향 특성, 침수 및 침출 특성, 열순환 특성 등에 대하여 표준시험법을 제시하였으며, 또한 그의 기술기준치도 제시하고 있다. 그리고 프랑스(DRDD/ BECC)에서는 미국보다 매우 세밀하게 평가항목들을 분류하는 등의 처분장 운영국가에서는 고화체의 안정성관련 평가시험들을 처분 환경과 처분방식에 맞게 표준화하고 있다. 한편 국내에서는 과기부 고시 제2001-32호 "중.저준위 방사성폐기물 인도규정"이 있으나 이에는 고화체 관련하여 정성적인 안정성에 대하여서만 기술되어 있다. 이에 따라 원전폐기물 고화체에 대한 안정성 평가를 위한 시험법을 선정하기 위하여 아래 그림과 같은 절차에 따라 수행토록 하였다. 우선 대표적인 천층처분 운영국가인 미국과 프랑스의 시험법 그리고 IAEA 권고 시험법과 유사관련 한국 산업표준법들을 조사하고, 이들 시험법들의 주요 차이점을 기술적 관점에서 비교평가하고, 이어서 모의 방사성 및 비방사성 고화체를 이용하여 상기 시험법들을 각각 적용하고 또한 이들 시험법들간의 차이(시험 조건, 시편의 크기 등)에 기인한 상호 비교시험을 통하여 얻어진 시험결과들을 종합적으로 비교 검토하여 보수적 관점에서 시험법을 선정하는 것으로 방향을 잡았다. 이때 시험결과를 얻기 위한 모든 과정에 품질보증 활동을 적용키로 하였으며, 시험결과 분석/평가 과정과 시험법 선정에 각계(규제기관, 학계, 발전소 현장 및 산업계 등) 전문가로부터 기술자문회의를 통하여 자문 의견을 받기로 하였다. 특히 현재 폐기물 인수 기술기준치가 설정된 국가의 시험법을 심층 있게 검토하기로 하였다.검토하기로 하였다.

  • PDF

Preparation of Radiopharmaceuticals (IV) Quality Control and Chemical Analysis of Radiopharmaceuticals (방사성의약품 합성 방식에 관한 연구 제4보 방사성의약품의 품질관리 및 안정도 시험)

  • Kim, You-Sun;Kim, Tae-Young
    • The Korean Journal of Nuclear Medicine
    • /
    • v.4 no.1
    • /
    • pp.51-60
    • /
    • 1970
  • In 1969 this laboratory had prepared 131 mc. of radiopharmaceuticals in total (Hippuran and other four kinds) and distributed to the major medical establishments. The quality and stability of these products were reviewed by means of radio paper partition chromatography and thin layer chromatography and results were compared to those of foreign products. Generally, the quality and stability of the product of this laboratory were better than those of the foreign product, even though the properties of the radiopharmaceutical were varied by the procedure of the preparation adopted. Various precautions for handling radiopharmaceuticals for clinical use were also described with a view of quality control and stability test there of.

  • PDF

A Study on Parameters of SUAV Landing Gear Orifice (SUAV 착륙장치 오리피스의 파라미터 연구)

  • Han, Jae-Do;Kang, Yeon-Sik;Ahn, Oh-Sung;Lee, Young-Sin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.1
    • /
    • pp.99-104
    • /
    • 2009
  • In this paper, the drop characteristic of the small aircraft landing gear of SUAV has been analyzed and performed on orifice optimal design for shock absorption efficiency. The SUAV landing gear was simple oleo pneumatic type without metering pin. The landing gear was modelled by MSC ADAMS software. Drop test evaluation was conducted to confirm the analysis model. As a result of correlation between analysis and test results, it was verified that these results were coincided with very well. After confidence review of analysis model through the correlation between test and analysis results, design parametric study was performed by using confirmed analysis model. Optimal orifice size with best efficiency have been decided in this study.