• Title/Summary/Keyword: 시트 두께

Search Result 161, Processing Time 0.029 seconds

Evaluating Impact Resistance of Externally Strengthened Steel Fiber Reinforced Concrete Slab with Fiber Reinforced Polymers (섬유 보강재로 외부 보강된 강섬유 보강 콘크리트 슬래브의 충격저항성능 평가)

  • Yoo, Doo-Yeol;Min, Kyung-Hwan;Lee, Jin-Young;Yoon, Young-Soo
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.3
    • /
    • pp.293-303
    • /
    • 2012
  • Recently, as construction technology improved, concrete structures not only became larger, taller and longer but were able to perform various functions. However, if extreme loads such as impact, blast, and fire are applied to those structures, it would cause severe property damages and human casualties. Especially, the structural responses from extreme loading are totally different than that from quasi-static loading, because large pressure is applied to structures from mass acceleration effect of impact and blast loads. Therefore, the strain rate effect and damage levels should be considered when concrete structure is designed. In this study, the low velocity impact loading test of steel fiber reinforced concrete (SFRC) slabs including 0%~1.5% (by volume) of steel fibers, and strengthened with two types of FRP sheets was performed to develop an impact resistant structural member. From the test results, the maximum impact load, dissipated energy and the number of drop to failure increased, whereas the maximum displacement and support rotation were reduced by strengthening SFRC slab with FRP sheets in tensile zone. The test results showed that the impact resistance of concrete slab can be substantially improved by externally strengthening using FRP sheets. This result can be used in designing of primary facilities exposed to such extreme loads. The dynamic responses of SFRC slab strengthened with FRP sheets under low velocity impact load were also analyzed using LS-DYNA, a finite element analysis program with an explicit time integration scheme. The comparison of test and analytical results showed that they were within 5% of error with respect to maximum displacements.

The optical analysis of the direct typed backlight for LCD TV (LCD TV용 직하형 백라이트의 광특성 분석)

  • Yoon, Dae-Keun;Oh, Young-Sik;Han, Jeong-Min;Bae, Kyung-Woon;Lim, Young-Jin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.109-112
    • /
    • 2004
  • 최근들어, TFT LCD 업체들의 제품 대형화에 따라서 서서히 제품군이 중, 대형 TV를 중심으로 넓은 광시야각 기술 (FFS, IPS, VA)이 적용되고 있으며 고휘도, 고속응답, 고색순도 등 성능향상을 지속하는 가운데 LCD 백라이트로써 LCD TV에 적용하기 위해서는 무엇보다도 현재 기존 제품군보다 높은 휘도 특성의 개선이 요구되고 있다. TV 대응 LCD Panel 은 Monitor 대응 제품에 비해서 일반적으로 해상도가 낮으므로, 투과율면에서 장점은 있으나, 현재의 백라이트 구조로는 만족할만한 성능을 낼 수 없는 상황이다. 그러므로 고휘도 백라이트를 위해서 직하방식 백라이트에 대한 개발 검토가 활발히 이루어지고 있다. 따라서 본 연구에서는 백라이트에서 6500nits를 목표로 직하형 백라이트의 시뮬레이션을 실시하였으며, 램프간 거리, 리플렉터와 램프간 거리, 램프와 확산판간 거리등에 해한 최적화를 통하여 총두께에 따른 특성분석을 실시하였다. 특히, 램프의 수량에 따른 휘도 시뮬레이션을 통해서 백라이트별 기구치수를 결정할 수 있었다. 본 연구에서의 목적인 6500nits의 휘도는 프리즘시트의 적용을 통하여 달성하였다.

  • PDF

A Study of Valve-train Life Time Estimate in Engine Durability Test (2) (엔진내구시험을 통한 Valve Train 수명예측에 관한 연구 (2))

  • Kim, Jaejin;Lee, Hwanhui;Myung, Wanghee;Min, Byengdu
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.3
    • /
    • pp.75-80
    • /
    • 2014
  • In previous study, make an attempt to estimate exhaust valve seat and seat-ring wear acceleration factor for engine durability test with measuring and consideration of wear mechanism. But found abnormal initial wear rate in exhaust valve seat-ring. And have to improve exhaust valve seat-ring wear rate for reliability reason, because next GDI/Turbo engine is based on this engine and GDI/Turbo engine have higher combustion pressure and higher thermal load. In this study, Trying to find the cause of abnormal wear factor, improve valve-train durability by change specification & design of parts and verify variant parts for improving durability of valve-train. And then I would like to propose a design guide line of valve-train system in a reliability point of view, besides make a complement of previous study.

A Study on Design of RF/UHF RFID Tag Antenna Using One-Sheet Inlay Pattern (One-Sheet Inlay 패턴을 이용한 RF/UHF RFID 태그 안테나 설계에 관한 연구)

  • Hwang, Gi-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.8
    • /
    • pp.1943-1949
    • /
    • 2010
  • In this paper, we developed a RFID tag antenna using one-sheet inlay pattern which consist of two different frequencies in one layer. The antenna in one-sheet inlay RFID tag does not use different kind RFID antennas in a card but implement 13.56MHz and 900MHz RFID tag antennas in one sheet. In order to evaluate the usability of proposed method, we configured test equipments and designed 6 different patterns and test the recognition distance of each pattern. Among the one-sheet inlay RFID tag antenna designs, the pattern no.5 has good performance with recognition distance of 5.34m at 900MHz and 3.5m at 13.56MHz.

Examination of Tensile and Adhesion Performance According to Components and Application Environment of Cement-mixed Polymer-based Waterproofing (시멘트 혼입 폴리머계 방수재의 구성요소 및 적용환경에 따른 인장·부착성능 평가)

  • Lee, Jin-Yong;Choi, Jeong-Kyun;Kim, Seong-Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.6
    • /
    • pp.41-49
    • /
    • 2021
  • Cement-mixed polymer-based waterproofing materials are generally used in the form of application by mixing in the field, and it is necessary to supplement the construction ability for air bubbles and uneven coating thickness due to irregularities during construction. The final purpose of this study is to improve the waterproofing performance by adding a sheet attaching process to the composite construction rather than the single process of painting and applying the construction method when applying the polymer waterproofing material to the field. In this regard, the applicability was evaluated by examining the material, environment, and manufacturing method.

Effects of Magnetic Powder Thickness on Electromagnetic Wave Absorption Characteristics in FeSiCr Flakes/Polymer Composite Sheets (FeSiCr 박편/폴리머 복합시트의 전자파 흡수 특성에 미치는 자성분말 두께의 영향)

  • Kim, Ju-Beom;Noh, Tae-Hwan
    • Korean Journal of Metals and Materials
    • /
    • v.47 no.12
    • /
    • pp.866-872
    • /
    • 2009
  • The effects of magnetic powder thickness on electromagnetic wave absorption characteristics in Fe-6.5Si-0.9Cr (wt%) alloy flakes/polymer composite sheets available for quasi-microwave band have been investigated. The atomized FeSiCr powders were milled by using attritor for 12, 24, and 36 h, powder thickness changed from $40{\mu}m$ to $3{\mu}m$ upon 36 h milling. The composite sheet, including thinned magnetic flakes, exhibited higher power loss in the GHz frequency range as compared with the sheets having thick flakes. Moreover, both the complex permeability and the loss factor increased with the decrease in thickness of the alloy flakes. Therefore, the enhanced power loss property of the sheets containing thin alloy flakes was attributed to the flakes of high complex permeability, especially their imaginary part. Additionally, the complex permittivity was also increased with the reduction of flake thickness, and this behavior was considered to be helpful for improvement of the electromagnetic wave absorption characteristics in the composite sheets, including thin alloy flakes.

Multi-Mode Wireless Power Transfer System with Dual Loop Structure (이중루프 구조를 갖는 다중모드 무선전력전송 시스템)

  • Han, Minseok
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.9 no.6
    • /
    • pp.578-583
    • /
    • 2016
  • In this paper, we propose a multi-mode wireless power transfer (WPT) system with a dual loop structure. The proposed multi-mode WPT system consist of outer loop module which can operate at two different frequency bands including 6.78 MHz magnetic resonance WPT mode and 13.56 MHz near field communication (NFC) mode and inner loop module connected with outer loop which can operate at two different frequency bands including WPC mode and PMA mode based on inductive coupling standards. In order to be able to embed this system into smartphone battery back cover, the electrical designs are optimized and then the size was fixed $45{\times}90{\times}0.35mm3$ (including ferrite sheet) which is the same commercial smartphone. The proposed multi-mode WPT module can cover WPC and PMA mode based on inductive coupling. Moreover, it has more than 20 dB return loss characteristics at two different frequency bands including 6.78 MHz and 13.56 MHz, and shows more than 70 % transfer efficiency between resonant coils at 6.78 MHz in magnetic resonant charging environment.

Design and Evaluation of Piezoelectric Energy Harvester using a Finite Element Method (유한요소법을 이용한 압전 에너지 하베스터의 설계 및 평가)

  • Kim, Chul-Min;Kim, Chang-Il;Lee, Joo-Hee;Paik, Jong-Hoo;Cho, Jeong-Ho;Chun, Myoung-Pyo;Jeong, Young-Hun;Lee, Young-Jin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.312-312
    • /
    • 2010
  • 모터나 기계류와 같이 주변에서 발생하는 미활용 진동에너지를 전기에너지로 수확하기 위한 Piezoelectric Energy Harvester를 개발하고자 하였다. PZT-5H의 조성으로 후막세라믹 적층 구조 캔틸레버 타입의 압전시트를 통해 압전 에너지 하베스터를 제작하였다. 일반적으로 진동에너지를 수확하여 전기에너지로 변환시키는 압전 에너지 하베스팅 기술은 에너지 효율이 낮은 문제점을 가지고 있으므로 에너지 효율을 높이기 위한 방법으로 본 연구에서는 Unimorph 와 Bimorph 타입의 캔틸레버의 가로, 세로, 두께, 재료변수에 따라 발생하는 최적의 효율을 가지는 구조를 찾고자 하였다. 캔틸레버 각 변수에 따른 공진주파수 대역에서 발생하는 전압을 분석하여 50Hz의 공진주파수를 가지는 60*35*0.2mm의 캔틸레버를 설계하였다. 시뮬레이션을 통해 얻어진 결과를 실험적으로 검증하기 위해 전력량을 측정한 결과, Bimorph는 Unimorph 타입에 비해 2배가량의 향상된 발전특성을 가지며 에너지 하베스터에서 초당 $76.2\;{\mu}W$의 전력량을 가지는 것을 확인하였고 시뮬레이션 결과와의 타당성을 확인하였다.

  • PDF

Improved Data Concealing and Detecting Methods for OOXML Document (OOXML 문서에 대한 향상된 데이터 은닉 및 탐지 방법)

  • Hong, Kiwon;Cho, Jaehyung;Kim, Soram;Kim, Jongsung
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.27 no.3
    • /
    • pp.489-499
    • /
    • 2017
  • MS office is a office software which is widely used in the world. The OOXML format has been applied to the document structure from MS office 2007 to the newest version. In this regard, the method of data concealing, which is a representative anti-forensic act has been researched and developed, so the method of detecting concealed data is very important to the digital forensic investigation. In this paper, we present an improved data concealing method bypassing the previewers detecting methods for OOXML formatted MS office documents. In addition, we show concealment of the internal data like sheets and slides for MS office 2013 Excel and PowerPoint, and suggest an improved detecting algorithm against this data concealing.

Monotonic Loading Test for CFT Square Column-to-Beam Partially Restrained Composite Connection (CFT 각형 기둥-보 합성 반강접 접합부의 단조가력 실험)

  • Choi, Sung Mo;Park, Su Hee;Park, Young Wook;Kim, Jin Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.3 s.76
    • /
    • pp.325-335
    • /
    • 2005
  • This study tackles the development of an improved detail of partially restrained CFT square column-to-beam connection and the evaluation of its mechanical behavior under monotonic loading. The connection is designed to strengthen shearing capacity at the bottom of the connection due to the ultimate behavior of PR-CC by its detail of the bottom connection and simplify the fabrication process. The suggested connection is the welded bottom beam flange connection(M-2) and is compared with the existing PR-CC of bolted seat angle connection(M-1). Two specimens were fabricated in actual size and tested under monotonic loading. Based on the test results, the welded bottom beam flange connection exhibited about 85% of the stiffness of steel beam. It was similar to the bolted seat angle connection and behaved as PR-CC. The specimen of the supposed connection type failed at the shear connection of web but was similar to the bolted seat angle connection until the failure. It obtained sufficient stiffness and capacity through the reinforcingsteel and the capacity and deformational ability equivalent to the full-plastic moment through the anchor inside the steel tube at the web connection. So, it can be said that the suggested connection exhibits sufficient ductile behavior.