• Title/Summary/Keyword: 시인

Search Result 107,040, Processing Time 0.125 seconds

Experimental studies on the characteristics of the mortar using dispersing agent of cement and high fluid admxiture (시멘트 분산제(分産劑) 및 고류동화제(高流動化劑)를 사용(使用)한 모르터의 제(諸) 성질(性質)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Kim, Seong Wan;Park, In-Gyu
    • Korean Journal of Agricultural Science
    • /
    • v.11 no.1
    • /
    • pp.146-159
    • /
    • 1984
  • This study was the contrast of the compressive strength, the tensile strength, the reducing ratio and the flow of mortar using dispersing agent and high fluid admix. 1. The admix ratio of chemical admixtures espressing maximum strength appeared the same result high fluid admix SP was 0.6%, the dispersing agents LG and C211 were 0.2%, SK was 0.3%, C376 was 0.5%. But two or three times more than standard quantity made the strength's fast lowness, which influenced bad to wateriness and retard the soli-dification. 2. When proper quantity of chemical admixture was used, the increment of compressive strength was as follows. High fluid admix SP was 40.7% and the average increasing rate of dispersing agents(C211 was 19.5%, LG was 19.1%, C376 was 17.9%) was 18.7% more than normal mortar in the codition of 7 days. Also, in the condition of 28 days, high fluid admix SP was about 24.4% and the average of dispersing agents(LG was 21.1%, C211 was 16.4%, SK was 11.1%, C376 was 7.6%) was 14.1%. 3. When proper quantity of chemical admixture was used, the increment of tensile strength was as follows. High fluid admixture SP was 26.6% and the average increasing agents(SK was 16.0%, C376 was 14.7%, LG was 10%, C211 was 5.8%) was 11.6%. Also, in the condition of 28 days, high fluid admix SP was 16.5% and the average increasing rate of dispersing agents(LG was 19.1%, SK was 10.6%, C211 was 10.1%, C376 was 8.7%) was 12.1%. 4. As for the reducing ratio of each dispersing agent, he flow of mortar was less than the slump of concrete. That is; the reducing ratio of concrete was 15% adding each dispersing agent, but the reducing ratio of mortar was in the range of from 5.8% to 13.5% in 1 : 1 mixture, from 7.6% to 14.2% in 1 : 2, from 9.5% to 18.8% in 1 : 3. 5. The fluidity of each chemical admixture was as follows. High fluid admix SP in the condition of 1: 1 and 1 : 2 showed the best result than other dispersing agent and 1 : 3 showed the same result like other agents. Therefore these good dispersing agents were suitable in the prepact concrete construction using intrusion mortar.

  • PDF

Comparison of Dietary Patterns, Health, and Blood Parameters of Elderly Women and College Women in the Seoul Area (노화 과정에 따른 노인과 여대생의 식생활, 건강 상태 및 혈액 성상 비교 연구)

  • Shin, Kyung-Ok;Chung, Keun-Hee;Choi, Kyung-Soon
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.19 no.5
    • /
    • pp.703-712
    • /
    • 2009
  • The principal objective of this study was to supply basic material determine basic information regarding effective health promotion regimens for elderly women via a comparative survey of health status by aging age between elderly women (=70 y) and college women. The subject groups of elderly women (=70 y) and college women were selected and surveyed from March to October, 2008, in the Seoul area. The average age of the elderly women assessed in this study was $78.64{\pm}7.30$, the average height was $147.07{\pm}5.72$ cm, and the average weight was $50.47{\pm}7.44$ kg. As compared with college women, a higher percentage of elderly women ate breakfast regularly, but the elderly women also experienced difficulties in chewing due to dentures, and therefore ate their meals with large quantities of liquids, and usually ate their meals within 10 minutes. The majority of elderly women suffered from at least one disease, and the most common symptom reported was hypertension (25%). 52.2% of elderly women and 47.8% of college women reported that they exercised 1~2 times per week. They reported that their favorite exercise was light exercise, such as jogging and athletics (73.1%). As compared with college women, the smoking rate was lower among elderly women, but some of the elderly women were long-time smokers or alcoholics. The differences in red blood cells counts, Hb, hematocrit, and MCV of the between elderly women and college women were significant. In addition, but the MCH and MCHC were higher in elderly women compared with college women and the total cholesterol of elderly woman ($175.62{\pm}38.89$ mg/dL) was significantly lower compared with college woman ($186.13{\pm}28.19$ mg/dL). TG ($127.89{\pm}51.25$ mg/dL) and LDL-cholesterol ($120.51{\pm}32.88$ mg/dL) of elderly woman were significantly higher than TG ($79.71{\pm}40.9$ 6mg/dL) and LDL-cholesterol($103.78{\pm}22.94$ mg/dL) of college woman (p<0.05). The levels of HDL-cholesterol ($58.78{\pm}12.90$ mg/dL) in the college women was significantly higher than the HDLcholesterol levels ($48.17{\pm}13.79$ mg/dL) of the elderly women (p<0.05). Serum vitamin C levels in elderly women were significantly higher than those of college women (p<0.05), whereas no significant difference was detected between the two groups. Consequently, it can be concluded that the appropriate education programs for dietary habits and health promotion are necessary for a healthier life. Additionally, it is necessary for individuals to precisely determine precisely their own health status, and develop appropriate dietary programs for themselves.

  • PDF

Factors Affecting Pregnancy Rates on Transfer of Pronuclear Microinjected Embryos in Korean Black Goats (전핵 미세 주입법으로 생산된 한국흑염소 수정란의 이식 조건이 수태율에 미치는 영향)

  • Choi, Y.S.;Shin, H.G.;Jang, S.K.;Yang, H.S.;Lee, O.K.;Lee, D.S.;Cho, J.K.;Shin, S.T.
    • Journal of Embryo Transfer
    • /
    • v.22 no.1
    • /
    • pp.53-61
    • /
    • 2007
  • This study was investigated factors affecting the pregnancy rates after transfer of pronuclear microinjected embryos for the production of transgenic Korean black goats. Embryo transfer was carried out in 343 recipient Korean black goats from September 1999 to June 2000. Estrus was induced by the insertion of intravaginal progesterone devices $CIDR^(R)$ for 2 weeks. A single injection of 400 IU equine chorionic gonadotropin was administered at 48h before $CIDR^(R)$ removal to increase the proportion of does cycling and ovulation rate. Good quality embryos were prepared by microinjection of DNA into the pronuclei of fertilized goat oocyte and cultured in vitro. Pronuclear microinjected $1{\sim}8$ cell stage embryos were surgically transferred into the oviducts of the recipient at day 4 or 5 following $CIDR^(R)$ removal, and morula to blastocyst stage embryos were surgically transferred into uterus at day 9. Pregnancy was diagnosed by transrectal ultrasound scanning at $20{\sim}30d$ and 8 weeks following embryo transfer. The pregnancy rate was affected by several factors, such as estrus induction, the number of previous transfer, transfer site, stage of CL (corpus luteum), the number of recipient CL, stage of embryos and the number of transferred embryo. The pregnancy rate was significantly higher in recipients that came into estrus naturally than recipients that induced to come into estrus with $CIDR^(R)$(59.1% vs. 36.8%; P<0.05). The pregnancy rate was higher when the embryos were transferred into the left oviduct than transferred into the right oviduct (42.9% vs. 35.3%; P<0.05). The pregnancy rate of recipients with $CH_1$ (early) stage corpus hemorrhagicum in ovary was hi틴or than recipient with $CH_3$ (late) stage hemorrhagicum (47.5% vs. 17.9%; P<0.01). Higher pregnancy rates were obtained by transfer of 1-cell stage embryos into oviduct while late blastocysts (51.6% vs. 66.7%; P<0.01) into uterus. The pregnancy rates when 3 embryos were transferred to recipients were significantly higher than when 2 embryos we.e transferred (47.6% vs. 27.0%; P<0.05). Although there were no significant difference among the group, adhesion of reproductive organs, uterine size, ovulation rate of recipients, presence of large follicle and difficulty of transfer affected pregnancy rate of recipient. Higher pregnancy rates were obtained in the recipients with $8{\sim}15m$ diameter uterine horn as compared to the recipients with <5m diameter or >20mm diameter uterine hem (38.9%, 20% vs. 18.2%), in the recipients with large follicle in the ovulated ovary ipsilaterally (53.6% vs. 37.1%) and in the transfer which was carried out easily (39.2% vs. 27.8%, 0%). In conclusion, the high rate of pregnancy was achieved following transfer of pronuclear microinjected embryos when three or four 1-cell stage embryos were transferred into oviduct with $CH_1$ stage corpus hemorrhagicum in the ovary of recipient which came into estrus naturally.

The Influence Evaluation of $^{201}Tl$ Myocardial Perfusion SPECT Image According to the Elapsed Time Difference after the Whole Body Bone Scan (전신 뼈 스캔 후 경과 시간 차이에 따른 $^{201}Tl$ 심근관류 SPECT 영상의 영향 평가)

  • Kim, Dong-Seok;Yoo, Hee-Jae;Ryu, Jae-Kwang;Yoo, Jae-Sook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.67-72
    • /
    • 2010
  • Purpose: In Asan Medical Center we perform myocardial perfusion SPECT to evaluate cardiac event risk level for non-cardiac surgery patients. In case of patients with cancer, we check tumor metastasis using whole body bone scan and whole body PET scan and then perform myocardial perfusion SPECT to reduce unnecessary exam. In case of short term in patients, we perform $^{201}Tl$ myocardial perfusion SPECT after whole body bone scan a minimum 16 hours in order to reduce hospitalization period but it is still the actual condition in which the evaluation about the affect of the crosstalk contamination due to the each other dissimilar isotope administration doesn't properly realize. So in our experiments, we try to evaluate crosstalk contamination influence on $^{201}Tl$ myocardial perfusion SPECT using anthropomorphic torso phantom and patient's data. Materials and Methods: From 2009 August to September, we analyzed 87 patients with $^{201}Tl$ myocardial perfusion SPECT. According to $^{201}Tl$ myocardial perfusion SPECT yesterday whole body bone scan possibility of carrying out, a patient was classified. The image data are obtained by using the dual energy window in $^{201}Tl$ myocardial perfusion SPECT. We analyzed $^{201}Tl$ and $^{99m}Tc$ counts ratio in each patients groups obtained image data. We utilized anthropomorphic torso phantom in our experiment and administrated $^{201}Tl$ 14.8 MBq (0.4 mCi) at myocardium and $^{99m}Tc$ 44.4 MBq (1.2 mCi) at extracardiac region. We obtained image by $^{201}Tl$ myocardial perfusion SPECT without gate method application and analyzed spatial resolution using Xeleris ver 2.0551. Results: In case of $^{201}Tl$ window and the counts rate comparison result yesterday whole body bone scan of being counted in $^{99m}Tc$ window, the difference in which a rate to 24 hours exponential-functionally notes in 1:0.114 with Ventri (GE Healthcare, Wisconsin, USA), 1:0.249 after the bone tracer injection in 12 hours in 1:0.411 with 1:0.79 with Infinia (GE healthcare, Wisconsin, USA) according to a reduction a time-out was shown (Ventri p=0.001, Infinia p=0.001). Moreover, the rate of the case in which it doesn't perform the whole body bone scan showed up as the average 1:$0.067{\pm}0.6$ of Ventri, and 1:$0.063{\pm}0.7$ of Infinia. According to the phantom after experiment spatial resolution measurement result, and an addition or no and time-out of $^{99m}Tc$ administrated, it doesn't note any change of FWHM (p=0.134). Conclusion: Through the experiments using anthropomorphic torso phantom and patients data, we found that $^{201}Tl$ myocardium perfusion SPECT image later carried out after the bone tracer injection with 16 hours this confirmed that it doesn't receive notable influence in spatial resolution by $^{99m}Tc$. But this investigation is only aimed to image quality, so it needs more investigation in patient's radiation dose and exam accuracy and precision. The exact guideline presentation about the exam interval should be made of the validation test which is exact and in which it is standardized about the affect of the crosstalk contamination according to the isotope use in which it is different later on.

  • PDF

Serum 25-Hydroxy Vitamin $D_3$ Analysis of Korean People (한국인 일반인의 혈청 25-Hydroxy Vitamin $D_3$의 분석)

  • Kim, Bo-Kyung;Jung, Hyun-Mi;Kim, Yun-Kyung;Kim, So-Young;Kim, Jee-Hyun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.133-137
    • /
    • 2010
  • Purpose: The main function of vitamin D is the mineralization of the brain by increase of calcium and phosphorus, in case it is insufficient in children, lime deposition on cartilage cannot occur so it leads to rachitis, and in adults, it leads to osteomalacia or osteoporosis. It is also strongly believed in the academic world that vitamin D can restrict the growth of cancer cells and prevent heart diseases, which is also somewhat proven in epidemiological researches. While the right density of vitamin D is still being studied, 20-32 ng/mL is believed to be the most ideal density. Therefore, I wanted analyze how much density of 25-Hydroxyvitamin D3 that Koreans possess. Materials and Methods: From February 20th, 2008 to April 21st, 2009, the collection of 2800 serums, from medical examination treated subjects by Neodin Medical Institute, have been tested. The targets were tested by 25-Hydroxyvitamin D (125I Kit: Diasorin, USA), and were analyzed by dividing into many different categories (gender, age, season, region). Results: The average density of male were 20 ng/mL, female 17.08 ng/mL. Per age groups, the density of males were as follows: 10~20-18 ng/mL, 21~30-17 ng/mL, 31~40-19 ng/mL, 41~50-21 ng/mL, 51~60-22 ng/mL, 61~70-22 ng/mL, 71~80-22 ng/mL and 81~90-19.9 ng/mL. Average density of females per age groups, were as follows: 10~20-16 ng/mL, 20~30-15.26 ng/mL, 30~40-16 ng/mL, 40~50-17 ng/mL, 50~60-19 ng/mL, 60~70-19 ng/mL, 70~80-19 ng/mL, and 80~90-17 ng/mL. Per seasons, From December to May, the subjects showed the density of 15.97 ng/mL, while from June to November, it showed 21.60 ng/mL. On density of males from January to April regionally, Seoul+Gyeonggi-Do-15.52 ng/mL, Gangwon-Do-15.33 ng/mL, Choongchung-Do-18.03 ng/mL, Jeonla-Do-18.68 ng/mL, Gyungsang-Do-18.76 ng/mL and Cheju Do-21.23 ng/mL. Conclusions: The vitamin D of Koreans is has been insufficient compared to the suggested amount. Ultraviolet rays, which is the main source of vitamin D is critical, therefore it is suggested that more outdoor activities can definitely help.

  • PDF

The Effect of Using Two Different Type of Dose Calibrators on In Vivo Standard Uptake Value of FDG PET (FDG 사용 시 Dose Calibrator에 따른 SUV에 미치는 영향)

  • Park, Young-Jae;Bang, Seong-Ae;Lee, Seung-Min;Kim, Sang-Un;Ko, Gil-Man;Lee, Kyung-Jae;Lee, In-Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.115-121
    • /
    • 2010
  • Purpose: The purpose of this study is to measure F-18 FDG with two different types of dose calibrator measuring radionuclide and radioactivity and investigate the effect of F-18 FDG on SUV (Standard Uptake Value) in human body. Materials and Methods: Two different dose calibrators used in this study are CRC-15 Dual PET (Capintec) and CRC-15R (Capintec). Inject 1 mL, 2 mL, 3 mL of F-18 FDG into three 2 mL syringes, respectively, and measure initial radioactivity from each dose calibrator. Then measure and record radioactivity at 30 minute interval for 270 minutes. According to the initial radioactivity, linearity between decay factor driven from radioactive decay formula and the values measured by dose calibrator have been analyzed by simple linear regression. Fine linear regression line optimizing values measured with CRC-15 through regression analysis on the basis of the volume of which the measured value is close to the most ideal one in CRC-15 Dual PET. Create ROI on lung, liver, and region part of 50 persons who has taken PET/CT test, applying values from linear regression equation, and find SUV. We have also performed paired t-test to examine statistically significant difference in the radioactivity measured with CRC-15 Dual PET, CRC-15R and its SUV. Results: Regression analysis of radioactivity measured with CRC-15 Dual PET and CRC-15R shows results as follows: in the case 1 mL, the r statistic representing correlation was 0.9999 and linear regression equation was y=1.0345x+0.2601; in 2 mL case, r=0.9999, linear regression equation y=1.0226x+0.1669; in 3 mL case, r=0.9999, linear regression equation y=1.0094x+0.1577. Based on the linear regression equation from each volume, t-test results show significant difference in SUV of ROI in lung, liver, region part in all three case. P-values in each case are as follows: in 1 mL case, lung, liver and region (p<0.0001); in 2 mL case, lung (p<0.002), liver and region (p<0.0001); in 3 mL case, lung (p<0.044), liver and region (p<0.0001). Conclusion: Radioactivity measured with CRC-15 Dual PET, CRC-15R, dose calibrator for F-18 FDG test, do not show difference correlation, while these values infer that SUV has significant differences in the aspect of uptake in human body. Therefore, it is necessary to consider the difference of SUV in human body when using these dose calibrator.

  • PDF

The Effect of PET/CT Images on SUV with the Correction of CT Image by Using Contrast Media (PET/CT 영상에서 조영제를 이용한 CT 영상의 보정(Correction)에 따른 표준화섭취계수(SUV)의 영향)

  • Ahn, Sha-Ron;Park, Hoon-Hee;Park, Min-Soo;Lee, Seung-Jae;Oh, Shin-Hyun;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.77-81
    • /
    • 2009
  • Purpose: The PET of the PET/CT (Positron Emission Tomography/Computed Tomography) quantitatively shows the biological and chemical information of the body, but has limitation of presenting the clear anatomic structure. Thus combining the PET with CT, it is not only possible to offer the higher resolution but also effectively shorten the scanning time and reduce the noises by using CT data in attenuation correction. And because, at the CT scanning, the contrast media makes it easy to determine a exact range of the lesion and distinguish the normal organs, there is a certain increase in the use of it. However, in the case of using the contrast media, it affects semi-quantitative measures of the PET/CT images. In this study, therefore, we will be to establish the reliability of the SUV (Standardized Uptake Value) with CT data correction so that it can help more accurate diagnosis. Materials and Methods: In this experiment, a total of 30 people are targeted - age range: from 27 to 72, average age : 49.6 - and DSTe (General Electric Healthcare, Milwaukee, MI, USA) is used for equipment. $^{18}F$- FDG 370~555 MBq is injected into the subjects depending on their weight and, after about 60 minutes of their stable position, a whole-body scan is taken. The CT scan is set to 140 kV and 210 mA, and the injected amount of the contrast media is 2 cc per 1 kg of the patients' weight. With the raw data from the scan, we obtain a image showing the effect of the contrast media through the attenuation correction by both of the corrected and uncorrected CT data. Then we mark out ROI (Region of Interest) in each area to measure SUV and analyze the difference. Results: According to the analysis, the SUV is decreased in the liver and heart which have more bloodstream than the others, because of the contrast media correction. On the other hand, there is no difference in the lungs. Conclusions: Whereas the CT scan images with the contrast media from the PET/CT increase the contrast of the targeted region for the test so that it can improve efficiency of diagnosis, there occurred an increase of SUV, a semi-quantitative analytical method. In this research, we measure the variation of SUV through the correction of the influence of contrast media and compare the differences. As we revise the SUV which is increasing in the image with attenuation correction by using contrast media, we can expect anatomical images of high-resolution. Furthermore, it is considered that through this trusted semi-quantitative method, it will definitely enhance the diagnostic value.

  • PDF

Relationships on Magnitude and Frequency of Freshwater Discharge and Rainfall in the Altered Yeongsan Estuary (영산강 하구의 방류와 강우의 규모 및 빈도 상관성 분석)

  • Rhew, Ho-Sang;Lee, Guan-Hong
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.16 no.4
    • /
    • pp.223-237
    • /
    • 2011
  • The intermittent freshwater discharge has an critical influence upon the biophysical environments and the ecosystems of the Yeongsan Estuary where the estuary dam altered the continuous mixing of saltwater and freshwater. Though freshwater discharge is controlled by human, the extreme events are mainly driven by the heavy rainfall in the river basin, and provide various impacts, depending on its magnitude and frequency. This research aims to evaluate the magnitude and frequency of extreme freshwater discharges, and to establish the magnitude-frequency relationships between basin-wide rainfall and freshwater inflow. Daily discharge and daily basin-averaged rainfall from Jan 1, 1997 to Aug 31, 2010 were used to determine the relations between discharge and rainfall. Consecutive daily discharges were grouped into independent events using well-defined event-separation algorithm. Partial duration series were extracted to obtain the proper probability distribution function for extreme discharges and corresponding rainfall events. Extreme discharge events over the threshold 133,656,000 $m^3$ count up to 46 for 13.7y years, following the Weibull distribution with k=1.4. The 3-day accumulated rain-falls which occurred one day before peak discharges (1day-before-3day -sum rainfall), are determined as a control variable for discharge, because their magnitude is best correlated with that of the extreme discharge events. The minimum value of the corresponding 1day-before-3day-sum rainfall, 50.98mm is initially set to a threshold for the selection of discharge-inducing rainfall cases. The number of 1day-before-3day-sum rainfall groups after selection, however, exceeds that of the extreme discharge events. The canonical discriminant analysis indicates that water level over target level (-1.35 m EL.) can be useful to divide the 1day-before-3day-sum rainfall groups into discharge-induced and non-discharge ones. It also shows that the newly-set threshold, 104mm, can just separate these two cases without errors. The magnitude-frequency relationships between rainfall and discharge are established with the newly-selected lday-before-3day-sum rainfalls: $D=1.111{\times}10^8+1.677{\times}10^6{\overline{r_{3day}}$, (${\overline{r_{3day}}{\geqq}104$, $R^2=0.459$), $T_d=1.326T^{0.683}_{r3}$, $T_d=0.117{\exp}[0.0155{\overline{r_{3day}}]$, where D is the quantity of discharge, ${\overline{r_{3day}}$ the 1day-before-3day-sum rainfall, $T_{r3}$ and $T_d$, are respectively return periods of 1day-before-3day-sum rainfall and freshwater discharge. These relations provide the framework to evaluate the effect of freshwater discharge on estuarine flow structure, water quality, responses of ecosystems from the perspective of magnitude and frequency.

Surgery Alone or Postoperative Adjuvant Radiotherapy in Rectal Cancer - With Respect to Survival, Pelvic Control, Prognostic Factor - (직장암에서 수술단독 또는 수술후 방사선치료 -생존율, 골반종양제어율, 예후인자를 중심으로-)

  • Nam, Taek-Keun;Ahn, Sung-Ja;Nah, Byung-Sik
    • Radiation Oncology Journal
    • /
    • v.19 no.4
    • /
    • pp.327-334
    • /
    • 2001
  • Purpose : To find out the role of postoperative adjuvant radiotherapy in the treatment of rectal cancer by comparing survival, pelvic control, complication rate, and any prognostic factor between surgery alone and postoperative radiotherapy group. Materials and methods : From Feb. 1982 to Dec. 1996 total 212 patients were treated by radical surgery with or without postoperative radiotherapy due to rectal carcinoma of modified Astler-Coiler stage $B2\~C3$. Of them, 18 patients had incomplete radiotherapy and so the remaining 194 patients were the database analyzed in this study. One hundred four patients received postoperative radiotherapy and the other 90 patients had surgery only. Radiotherapy was peformed in the range of $39.6\~55.8\;Gy$ (mean: 49.9 Gy) to the whole pelvis and if necessary, tumor bed was boosted by $5.4\~10\;Gy$. Both survival and pelvic control rates were calculated by Kaplan-Meier method and their statistical significance was tested by Log-rank test. Multivariate analysis was peformed by Cox proportional hazards model. Results : 5-year actuarial survival rate (5YSR) and 5-year disease-free survival rate (5YDFSR) of entire patients were $53\%\;and\;49\%$, respectively. 5YSRs of surgery alone group and adjuvant radiotherapy group were $63\%\;vs\;45\%$, respectively (p=0.03). This difference is thought to reflect uneven distribution of stages between two treatment groups (p<0.05 by $\chi^2-test$) with more advanced disease patients in adjuvant radiotherapy group. 5YSRs of surgery alone vs adjuvant radiotherapy group in MAC B2+3, C1, C2+3 were $68\%\;vs\;55\%$ (p=0.09), $100\%\;vs\;100\%$, $40\%\;vs\;33\%$ (p=0.71), respectively. 5YDFSRs of surgery alone vs adjuvant radiotherapy group in above three stages were $65\%\;vs\;49\%$ (p=0.14), $100\%\;vs\;100\%$, $33\%\;vs\;31\%$ (p=0.46), respectively. 5-year pelvic control rate (5YPCR) of entire patients was $72.5\%$. 5YPCRs of surgery alone and adjuvant radiotherapy group were $71\%\;vs\;74\%$, respectively (p=0.41). 5YPCRs of surgery alone vs adjuvant radiotherapy group in B2+3, C1, C2+3 were $79\%\;vs\;75\%$ (p=0.88), $100\%\;vs\;100\%$, $44\%\;vs\;68\%$ (p=0.01), respectively. Multivariate analysis showed that only stage was significant factor affecting overall and disease-free survival in entire patients and also in both treatment groups. In view of pelvic control, stage and operation type were significant in entire patients and only stage in surgery alone group but in adjuvant radiotherapy group, operation type instead of stage was the only significant factor in multivariate analysis as a negative prognostic factor in abdominoperineal resection cases. Conclusion : Our retrospective study showed that postoperative adjuvant radiotherapy could improve the pelvic control in MAC C2+3 group. To improve both pelvic control and survival in all patients with MAC B2 or more, other treatment modality such as concurrent continuous infusion of 5-FU, which is the most standard agent, with radiotherapy should be considered.

  • PDF

Evaluation of the Positional Uncertainty of a Liver Tumor using 4-Dimensional Computed Tomography and Gated Orthogonal Kilovolt Setup Images (사차원전산화단층촬영과 호흡연동 직각 Kilovolt 준비 영상을 이용한 간 종양의 움직임 분석)

  • Ju, Sang-Gyu;Hong, Chae-Seon;Park, Hee-Chul;Ahn, Jong-Ho;Shin, Eun-Hyuk;Shin, Jung-Suk;Kim, Jin-Sung;Han, Young-Yih;Lim, Do-Hoon;Choi, Doo-Ho
    • Radiation Oncology Journal
    • /
    • v.28 no.3
    • /
    • pp.155-165
    • /
    • 2010
  • Purpose: In order to evaluate the positional uncertainty of internal organs during radiation therapy for treatment of liver cancer, we measured differences in inter- and intra-fractional variation of the tumor position and tidal amplitude using 4-dimentional computed radiograph (DCT) images and gated orthogonal setup kilovolt (KV) images taken on every treatment using the on board imaging (OBI) and real time position management (RPM) system. Materials and Methods: Twenty consecutive patients who underwent 3-dimensional (3D) conformal radiation therapy for treatment of liver cancer participated in this study. All patients received a 4DCT simulation with an RT16 scanner and an RPM system. Lipiodol, which was updated near the target volume after transarterial chemoembolization or diaphragm was chosen as a surrogate for the evaluation of the position difference of internal organs. Two reference orthogonal (anterior and lateral) digital reconstructed radiograph (DRR) images were generated using CT image sets of 0% and 50% into the respiratory phases. The maximum tidal amplitude of the surrogate was measured from 3D conformal treatment planning. After setting the patient up with laser markings on the skin, orthogonal gated setup images at 50% into the respiratory phase were acquired at each treatment session with OBI and registered on reference DRR images by setting each beam center. Online inter-fractional variation was determined with the surrogate. After adjusting the patient setup error, orthogonal setup images at 0% and 50% into the respiratory phases were obtained and tidal amplitude of the surrogate was measured. Measured tidal amplitude was compared with data from 4DCT. For evaluation of intra-fractional variation, an orthogonal gated setup image at 50% into the respiratory phase was promptly acquired after treatment and compared with the same image taken just before treatment. In addition, a statistical analysis for the quantitative evaluation was performed. Results: Medians of inter-fractional variation for twenty patients were 0.00 cm (range, -0.50 to 0.90 cm), 0.00 cm (range, -2.40 to 1.60 cm), and 0.00 cm (range, -1.10 to 0.50 cm) in the X (transaxial), Y (superior-inferior), and Z (anterior-posterior) directions, respectively. Significant inter-fractional variations over 0.5 cm were observed in four patients. Min addition, the median tidal amplitude differences between 4DCTs and the gated orthogonal setup images were -0.05 cm (range, -0.83 to 0.60 cm), -0.15 cm (range, -2.58 to 1.18 cm), and -0.02 cm (range, -1.37 to 0.59 cm) in the X, Y, and Z directions, respectively. Large differences of over 1 cm were detected in 3 patients in the Y direction, while differences of more than 0.5 but less than 1 cm were observed in 5 patients in Y and Z directions. Median intra-fractional variation was 0.00 cm (range, -0.30 to 0.40 cm), -0.03 cm (range, -1.14 to 0.50 cm), 0.05 cm (range, -0.30 to 0.50 cm) in the X, Y, and Z directions, respectively. Significant intra-fractional variation of over 1 cm was observed in 2 patients in Y direction. Conclusion: Gated setup images provided a clear image quality for the detection of organ motion without a motion artifact. Significant intra- and inter-fractional variation and tidal amplitude differences between 4DCT and gated setup images were detected in some patients during the radiation treatment period, and therefore, should be considered when setting up the target margin. Monitoring of positional uncertainty and its adaptive feedback system can enhance the accuracy of treatments.