• Title/Summary/Keyword: 시야선

Search Result 71, Processing Time 0.027 seconds

A study on the polarization transmission characteristics of liquid crystal display devices by means of Berreman's $4{\times}4$ matrix method (베레만의 $4{\times}4$행렬방식을 이용한 액정표시소자의 편광투과특성 분석)

  • Yang, Byeong-Kwan;Kim, Gyu-Seok;Rho, Bong-Gyu;Kim, Jin-Seung;Par, Hee-Gap;Park, Chan;Lee, Hyong-Jong;Kim, Jae-Ki
    • Korean Journal of Optics and Photonics
    • /
    • v.8 no.3
    • /
    • pp.223-229
    • /
    • 1997
  • A source code is developed on the basis of Berreman's 4$\times$4 matrix formalism for the analysis of polarization transmission characteristics of twisted nematic liquid crystal display. By using the program, the polarization transmission characteristics of liquid crystal cells and polarizers are analyzed. For a normally white twisted nematic liquid crystal cell, we obtained a family of iso-contrast contours which helps to understand the viewing angle characteristics of the liquid crystal display device by using the cell. The program also help us to understand the variation of the degree of polarization as well as the deviation of the state of polarization of the light transmitted through the polarizer commonly used in the LCD according to the change in incidence angle. This result suggests the contrast of the images appearing on the LCD can be limited by the characteristics of the polarizer in addition to the liquid crystal cell.

  • PDF

A Comparative Study on Discomfort Glare Sensation in Entire Visual Field for Position Index (포지션 인덱스 작성을 위한 상·하부 시야의 불쾌글레어감 비교)

  • Kim, Won-woo;Park, Sung-Ryul;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.7 no.6
    • /
    • pp.37-43
    • /
    • 2007
  • Discomfort glare is an important factor influencing appraisal for lighting environment. Unified Glare Rating (UGR) which has been proposed by CIE is one of the formula for evaluating discomfort glare. Position index is an important factor in the UGR formula. Position index was proposed by Guth in 1949. It has been used until present limiting upper visual field. Lower visual field has different sensation of brightness in comparing with upper visual field. Therefore, it is necessary to propose position index about lower visual field. The objective of this study is to investigate the brightness sensation in upper and lower visual field. First, the visual field was measured on the self-made Glare Tester. Second, luminance of the Borderline between Comfort and Discomfort (BCD) was measured on the glare Tester. Circular sources of brightness were located at various angular distances from the line of vision along five meridians, $0^{\circ}$, $45{\circ}$, $90{\circ}$, $-45{\circ}$, $-90{\circ}$. The size of the glare source is 0.0011sr. The luminance of the surrounding field, which extended over the entire visual field, was maintained $34ccd/m^2$. Ten subjects aged from 25 to 29 were participated in the experiment. The results show that the luminance of BCD on the line of vision is $4337cd/m^2$ and the glare sensation of the lower visual field is more sensitive than the upper visual field.

On-Glass Vehicle Antennas Using a Multi-Loop Structure (다중 루프 형태의 차량용 글래스 안테나)

  • Ahn, Seung-Beom;Kay, Young-Chul;Choo, Ho-Sung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.3
    • /
    • pp.230-239
    • /
    • 2009
  • In this paper, we propose a novel on-glass antenna for FM radio reception in a recreation vehicle(RV). We use a multi-loop structure that takes advantage of a broad matching bandwidth and a high vertical radiation gain by efficiently utilizing a given space of a quarter glass in spite of the simple planar structure. Transparency of the antenna is also improved by adjusting the stripline widths based on the induced current distributions. The proposed antenna is printed on a quarter glass of a commercial vehicle and antenna performances such as the return loss and the gain are measured in a semi-anechoic chamber. The result shows the average gain of -9.67 dBi along the bore-sight direction($\theta=90^{\circ}$, $\phi=270^{\circ}$) in the FM radio band(80$\sim$l10 MHz), which is higher than a commercial monopole typed on-glass antenna($G_{ave}$=-12.49 dBi) and micro-antenna($G_{ave}$=-19.24 dBi) mounted on the roof of the RV.

The Effects of Rat's Sperm Bioassay for Low Dose X-Ray (저선량 X-선 조사가 쥐의 정자에 미치는 생물학적효과)

  • Jin, Gye-Hwan;Min, Soo-Young;Lee, Sang-Bock;Lee, Sam-Yul;Park, Jong-Bae;Lee, Jun-Haeng
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.4
    • /
    • pp.184-189
    • /
    • 2007
  • In order to investigate the enhancement effects of low dose radiation on biological activation, this study applied low dose X-ray to the whole body of male rats to find out whether hormesis is induced in male germ cells. Total 36 Sprague-Dawley(SD) rats as experimental animal were subdivided into 6 groups(in 6 rats per group) such as control, 10 mGy, 20 mGy, 50 mGy, 100 mGy and 200 mGy radiation group All the groups showed slightly increasing number of sperms per 0.1g semen ($14.216{\times}10^6,\;13.901{\times}10^6,\;14.153{\times}10^6,\;13.831{\times}10^6,\;14.137{\times}10^6,\;14.677{\times}10^6$ respectively), and the motility of sperms amounted to 50.9%, 49.5%, 55.1%, 54.3%, 48.0% and 52.2% respectively. Particularly, compared to the control, the other 5 groups showed higher male hormone level, and the microscopic observations of testicle tissues showed no vacuolization in seminiferous tubules and testis cells. In the results of this experiment, no harmful effect was observed on Sprague-Dawley (SD) rats for which the dose of radiation was controlled as regulated legally by the Ministry of Science and Technology and the Ministry of Health and Welfare. However, as these results were obtained from a limited number of animals, we cannot maintain that the same effect will be observed in the human body. Therefore, there should be further research on the effect on other animals and ultimately on the human body.

B-site Cationic Ordering Structures of Donor-Doped Relaxor Ferroelectric $Pb({Mg_{1/3}}{Nb_{2/3})}O_3$ (전자 주게가 첨가된 완화형 강유전체 $Pb({Mg_{1/3}}{Nb_{2/3})}O_2$의 B자리 양이온 질서배열구조)

  • Cha, Seok-Bae;Kim, Byeong-Guk;Je, Hae-Jun
    • Korean Journal of Materials Research
    • /
    • v.10 no.7
    • /
    • pp.478-481
    • /
    • 2000
  • Single phase $Pb(Mg_{1/3}Nb_{2/3})O_3$ ceramics doped by 10 mol% of electron donors such as $La^3,\; Pr^{3+,4+},\; Nd^{3+},\; Sm^{3+}$, were synthesized and their B-site cationic ordering structures were investigated by XRD and TEM. In the XRD patterns, only fundamental reflections were observed for the undoped $Pb(Mg_{1/3}Nb_{2/3})O_3$, while the (h/2 $\textsc{k}$/2ι/2)(h,$\textsc{k}$,ι all odd) superlattice reflections resulting from the 1:1 ordering induced unit cell doubling were also observed for the donor-doped $Pb(Mg_{1/3}Nb_{2/3})O_3$. In the TEM selected area diffraction patterns, the (h/2 k/2 l/2)(h,k,l all odd) superlattice reflection spots as well as the fundamental reflection spots were observed for all the samples, but the relative intensities of the superlattice reflection spots to the fundamental reflection spots were significantly enhanced by the donor-doping. In the TEM dark-field images, antiphase boundaries were observed only for the donor-doped $Pb(Mg_{1/3}Nb_{2/3})O_3$. It was therefore experimentally verified that doping by electron donors such as $La^3,\; Pr^{3+,4+},\; Nd^{3+},\; Sm^{3+}$, enhances the B-site cationic 1:1 ordering in $Pb(Mg_{1/3}Nb_{2/3})O_3$. These experimental results were interpreted in terms of the charge compensation mechanism.

  • PDF

DOI Detector Design using Different Sized Scintillators in Each Layer (각 층의 서로 다른 크기의 섬광체를 사용한 반응 깊이 측정 검출기 설계)

  • Seung-Jae, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.11-16
    • /
    • 2023
  • In preclinical positron emisson tomography(PET), spatial resolution degradation occurs outside the field of view(FOV). To solve this problem, a depth of interaction(DOI) detector was developed that measures the position where gamma rays and the scintillator interact. There are a method in which a scintillation pixel array is composed of multiple layers, a method in which photosensors are arranged at both ends of a single layer, a method in which a scintillation pixel array is constituted in several layers and a photosensor is arranged in each layer. In this study, a new type of DOI detector was designed by analyzing the characteristics of the previously developed detectors. In the two-layer detector, different sizes of scintillation pixels were used for each layer, and the array size was configured differently. When configured in this form, the positions of the scintillation pixels for each layer are arranged to be shifted from each other, so that they are imaged at different positions in a flood image. DETECT2000 simulation was performed to confirm the possibility of measuring the depth of interaction of the designed detector. A flood image was reconstructed from a light signal acquired by a gamma-ray event generated at the center of each scintillation pixel. As a result, it was confirmed that all scintillation pixels for each layer were separated from the reconstructed flood image and imaged to measure the interaction depth. When this detector is applied to preclinical PET, it is considered that excellent images can be obtained by improving spatial resolution.

The studies of the granite landforms in South Korea (한국의 화강암 지형에 대한 연구)

  • KANG, Tay-Gyoon
    • Journal of The Geomorphological Association of Korea
    • /
    • v.18 no.4
    • /
    • pp.1-15
    • /
    • 2011
  • This work is to review the granite landforms studies by Korean geographers. It is verified that geomorphlogical characteristics of granite present landscapes characterized by 1) in case of mountains, are difficultly or irregularly weathered, so as to develop rocky forms such as domes, cliffs, and tors ; 2) in case of stream valley that is inter-massif lowland, low relief hills and flood plains with alluvium. All these facts owe to the difference of weathering mode granite properties. The granite hills and alluvial plains of southwestern coastal parts in Korean peninsula is low undulatory and large owing not only to the existence of highly weathered granitic regolith, but also to frequent flooding. Cultivated brownish field, orchard, meadow and forest are located at granite hills. On the other hand paddy rice field at granite alluvial plains. Korean peninsula have endured erodible geomorphlogical processes since Miocene when warping it up. Therefore many intermontane basins are located on the weathered granite areas which are surrounded by mountains composed of much less Precambrian gneiss complex. In fact, intermontane basin is mainly linear fault-line valley. The landforms of the intermontane basins are characterized by gentle piedmont slopes, alluvial fans, fluvial terraces and alluvial plains.

The Correlations of Parameters Using Contrast Enhanced Ultrasonography in the Evaluation of Prostate Cancer Angiogenesis (전립선암쥐모형의 신생혈관생성의 평가를 위해 시행된 역동적 조영 증강 초음파에서 얻은 변수간의 상관성연구)

  • Hwang, Sung Il;Lee, Hak Jong;Kim, Kil Joong;Chung, Jin-haeng;Jung, Hyun Sook;Jeon, Jong June
    • Ultrasonography
    • /
    • v.32 no.2
    • /
    • pp.132-142
    • /
    • 2013
  • Purpose: The purpose of this study is to investigate the correlations of various kinetic parameters derived from the time intensity curve in a xenograft mouse model injected with a prostate cancer model (PC-3 and LNCaP) using an ultrasound contrast agent with histopathologic parameters. Materials and Methods: Twenty nude mice were injected with human prostate cancer cells (15 PC-3 and five LNCaP) on their hind limbs. A bolus of $500{\mu}L$ ($1{\times}10^8$ microbubbles) of second-generation US contrast agent (SonoVue) was injected into the retroorbital vein. The region of interest was drawn over the entire tumor. The time intensity curve was acquired and then fitted to a gamma variate function. The maximal intensity (A), time to peak (Tp), maximal wash-in rate (washin), washout rate (washout), area under the curve up to 50 sec ($AUC_{50}$), area under the ascending slope ($AUC_{in}$), and area under the descending slope ($AUC_{out}$) were derived from the parameters of the gamma variate fit. Immunohistochemical staining for VEGF and CD31 was performed. Tumor volume, the area percentage of VEGF stained in a field, and the count of CD31 (microvessel density, MVD) positive vessels showed correlation with the parameters from the time intensity curve. Results: No significant differences were observed between the kinetic and histopathological parameters from each group. MVD showed positive correlation with A (r=0.625, p=0.003), washin (r=0.462, p=0.040), $AUC_{50}$ (r=0.604, p=0.005), and $AUC_{out}$ (r=0.587, p=0.007). Positive correlations were also observed between tumor volume and $AUC_{50}$ (r=0.481, p=0.032), washin (r=0.662, p=0.001), and $AUC_{out}$ (r=0.547, p=0.012). Washout showed negative correlations with MVD (r=-0.454, p=0.044) and tumor volume (r=-0.464, p=0.039). The area percentage of VEGF did not show any correlation with calculated data from the curve. Conclusion: MVD showed correlations with several of the kinetic parameters. CEUS has the potential for prediction of tumor vascularity in a prostate cancer animal model.

An Examination on the Dispersion Characteristics of Boil-off Gas in Vent Mast Exit of Membrane Type LNG Carriers (멤브레인형 LNG선박 화물탱크 벤트 마스트 출구에서의 BOG 확산 특성에 관한 연구)

  • Kang, Ho-Keun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.19 no.2
    • /
    • pp.225-231
    • /
    • 2013
  • Liquefied gas carriers generally transport cargoes of flammable or toxic nature. Since these cargoes may cause an explosion, fire or human casualty, the accommodation spaces, service spaces and control stations of liquefied gas carriers should be so located as to avoid ingress of gas. For this reason, the paragraph 8.2.9 of IGC Code in IMO requires that the height of vent exits should be not less than B/3 or 6 m whichever is greater, above the weather deck and 6 m above the working area and the fore and aft gangway to prevent any concentration of cargo vapor or gas at such spaces. Besides as known, the LNG market has been growing continually, which has led to LNG carriers becoming larger in size. Under this trend, the height of a vent will have to be raised considerably since the height of a vent pipe is generally decided by a breadth of a corresponding vessel. Accordingly, we have initiated an examination to find an alternative method which can be used to determine the safe height of vent masts, instead of the current rule requirement. This paper describes the dispersion characteristics of boil-off gas spouted from a vent mast under cargo tank cool-down conditions in the membrane type LNG carriers.

Design of DOI Detector Module for PET through the Light Spread Distribution (빛 분포를 통한 양전자방출단층촬영기기의 반응 깊이 측정 검출기 모듈 개발)

  • Lee, Seung-Jae;Baek, Cheol-Ha
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.637-643
    • /
    • 2018
  • A depth of interaction(DOI) detector module using a block scintillator and a pixellated scintillator was designed, and layer discrimination ability was calculated using DETECT2000. The block scintillator was used to improve the sensitivity and the spatial resolution was improved by measuring the DOI. The DOI was measured by analyzing the signal characteristics of each channel of the changed distribution of light. The detector module was composed to the block scintillator in the top layer and the pixellated scintillator in the bottom layer, which changes the distribution of light generated from a scintillator interacting with a gamma ray. In the flood image, the top layer was able to acquire the image at the position similar to the position of the bottom layer because the bottom layer consist of the pixellated scintillator. By using the Anger algorithm, the 16 channel signal was reduced to 4 channels to facilitate the analysis of the signal characteristics. The layer discrimination was measured using a simple algorithm and the accuracy was about 84% for each layer. When this detector module is used in preclinical PET, the spatial resolution at the outside of the field of view can be improved by measuring the DOI.