• Title/Summary/Keyword: 시스템 RAID

Search Result 98, Processing Time 0.021 seconds

Design of Soft RAID Storage System for SSD(Solid State Disk) (SSD를 위한 Soft RAID 저장 시스템 설계)

  • Byun, Si-Woo;Hur, Moon-Hang;Roh, Chang-Bae;Kim, Deog-Tae
    • Proceedings of the KAIS Fall Conference
    • /
    • 2008.05a
    • /
    • pp.218-219
    • /
    • 2008
  • Solid State Disks(SSD) are one of the best candidates to support next storage technology in desktop and server computing environment. The features of non-volatility, low power consumption, and fast access time for read operations are sufficient grounds to support SSD as major components of future storages. This paper describes a technical trend of HDD based RAID technology and proposes a new RAID system for SSD.

  • PDF

G-RAID: A Green RAID Mechanism for enhancing Energy-Efficiency in Massive Storage System (G-RAID: 대용량 저장장치에서 에너지 효율향상을 위한 그린 RAID 기법)

  • Kim, Young-Hwan;Suck, Jin-Sun;Park, Chang-Won;Hong, Ji-Man
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.6
    • /
    • pp.21-30
    • /
    • 2011
  • In the global IT market, a lot of issues for responding to various environmental regulations emerged. In case of the data centers, it is consuming huge amounts of energy to maintain. So there have been various technical attempts as Consolidation, Virtualization, Optimization to efficiently manage energy and data storage to fix the problems. In this paper, we propose a new RAID(Redundant Array of Independent Disks) mechanism which is differing the intensity of power consumption and works to provide data protection and disaster recovery(backup, mirroring etc.) to stratify multiple volumes. G-RAID minimize the power consumption and the lower of I/O performance by selecting the volume depending on the frequency of data access while classifying the power consumption between volumes in storage system. Also, it is possible that a filesystem and block map information of G-RAID is processed by basic unit which is group located in a row for the blocks to work efficiently and can minimize the performance degradation of block mapping load by the access frequency in each groups. As a result, we obtained to elevate a little bit of response time caused by block relocation work, but showed the decrease of power consumption by 38%.

Implementation of Hardware RAID and LVM-based Large Volume Storage on Global Data Center System of International GNSS Service

  • Lee, Dae-Kyu;Cho, Sung-Ki;Park, Jong-Uk;Park, Pil-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1553-1557
    • /
    • 2005
  • High performance and reliability of the storage system to handle a very large amount of data has been become very important. Many techniques have been applied on the various application systems to establish very large capacity storage that satisfy the requirement of high I/O speed and physical or logical failure protection. We applied RAID and LVM to construct a storage system for the global data center which needs a very reliable large capacity storage system. The storage system is successfully established and equipped on the latest Linux application server.

  • PDF

Efficient Techniques for Software RAID of SAN based on shared Storage systems (SAN기반 공유 저장 장치 시스템에서 고성능 소프트웨어 RAID를 위한 기법)

  • 김경호;황주영;안철우;박규호
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2001.10c
    • /
    • pp.55-57
    • /
    • 2001
  • 본 논문에서는 최근 이슈가 되고 있는 Fibre Channel과 같은 네트워크를 이용한 공유 디스크 시스템에서 다수의 호스트가 소프웨어 RAID\ulcorner 4 흑은 5를 이용할 때, 디스크 공유에 의해 발생하는 패리티 블록 일관성 문제를 다룬다. 본 논문에서는 XDWRITE을 이용해 Software HAID에서의 일관성 문제 해결과 디스크 1/0수 감소에 대해 설명한다. 또한, 버퍼캐쉬에서 파일 블록 쓰기 발생시 원본의 복사본을 이용하여 패리티 계산을 위한 디스크 읽기의 수를 감소 시키는 방법에 대해 제안한다. 본 논문에서 제안한 방식은 기존의 방식인 보다 1.5배에서 2배 디스크 1/0의 수를 감소시키는 것을 알 수 있다.

  • PDF

Self Recovery System With High Availability in Clustered VOD Server (클러스터형 VOD 서버에서 고가용성을 고려한 자체 복구 시스템)

  • Lee, Joa-Hyoung;Seo, Dong-Mahn;Bang, Cheol-Seok;Kim, Byoung-Gil;Park, Chong-Myung;Jung, In-Bum
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2003.11a
    • /
    • pp.149-152
    • /
    • 2003
  • 최근 VOD 서버 모델로 제안되는 클러스터형 VOD 서버는 확장성과 가용성을 높일 수 있다는 장점이 있지만 서버에 노드수가 증가하면서 서버에 장애가 발생할 가능성이 높아지는 문제점을 가지고 있다. 본 논문에서는 클러스터형 VOD 서버에서 노드 장애 발생시 이를 복구하기 위한 방안으로서 RAID-3, 4의 특성을 취합하고, 이에 파이프라인 개념을 더한 복구 시스템을 제시하고자 한다. 본 복구 시스템은 RAID-4 개념을 도입하여 디스크로의 접근을 큰 사이즈의 블록단위로 함으로써 디스크의 효율성을 증가시키며, 네트웍에는 RAID-3 개념을 적용하여 작은 사이즈의 블록으로 나누어 전송함으로써 네트웍을 효율적으로 사용하고 메모리 부하를 줄일 수 있도록 한다. 또한 파이프라인 개념을 도입하여 복구과정을 여러 노드에서 분담하여 동시에 처리함으로써 CPU, 네트웍, 메모리 등과 같은 자원에 대한 부하가 모든 노드로 분산되도록 한다.

  • PDF

The Mapping Method by Equation for Adding Disks for Striping System (스트라이핑 시스템에서 디스크 추가를 위한 계산에 의한 매핑 방법)

  • 박유현;김창수;강동재;김영호;신범주
    • Journal of Korea Multimedia Society
    • /
    • v.6 no.1
    • /
    • pp.15-27
    • /
    • 2003
  • Recently, the volume of data is increasing rapidly in server for multimedia service, according to development of multimedia application environment. In recent research for storage technology the technology like of the SAN(Storage Area Network) advantages in scalibility of storage devices, and can read data from multiple disk arrays through RAID 0, 5. The RAID 0 and 5 translate to logical address to physical address using equation, but in case of adding disks at the system with equation -based mapping, the problem that we must rearrange the whole data in the previous disks happens. We use the mapping table to solve this problem in recent, but we can not load the whole mapping table in main memory because it occupies too large space. Therefore the extra I/Os are demanded to evaluate real physical address of data, so total performance of the system is degraded. In this paper, we propose the mapping method that supports the scalibility in RAID 0 or 5 system. The proposing method applies small metadata, so- called SZIT and simple equation, so it is possible that we make translate logical address to physical address rapidly and it is scalable in disk extending simultaneously Our suggesting method, if we add disks to the striping system for expanding of storage capacity, has an advantage of never stop service. So, SZlT-based mapping method can do online-disk-expanding in real-time service.

  • PDF

Reliable and Flexible Storage System for NAS Environments (NAS를 위한 신뢰성과 확장성이 있는 저장 장치 시스템)

  • Lee, Tae-Keun;Kang, Yong-Hyeog;Eom, Young-Ik
    • The KIPS Transactions:PartD
    • /
    • v.10D no.7
    • /
    • pp.1085-1092
    • /
    • 2003
  • The rapid growth of high speed multimedia services demands the large capacity of the server's storage that maintains the multimedia contents. Among the server's devices, the low I/O speed and physical or logical failure of storage device decrease the total performance of system. The continuous increase of multimedia contents require the flexibility of storage capacity. In order to solve the these problems, we propose the uses of software RAID and LVM techniques that provide the performance improvement and reliability of storage device and the flexibility of storage device respectively. In the LINUX 2.4 kernel, we implemented the reliable and flexible storage device and evaluated the performance of it.

The SZIT based-mapping method for on-line adding disks in software RAID (소프트웨어 RAID에서 온라인 디스크 부착이 가능한 SZIT 기반 매핑 기법)

  • Bak, Yu-hyeon;Kim, Chang-soo;Kang, Dong-jae;Kim, Young-ho;Shin, Bum-joo
    • The KIPS Transactions:PartA
    • /
    • v.9A no.4
    • /
    • pp.535-546
    • /
    • 2002
  • According as the users can connect to remote hosts at anytime by using internet, the demand of non-stop system is increased. Also, the research about on-line adding/deleting disks and hosts are progressed. This paper suggests that the method of reducing additional operation when we add disks to the stripping system. That method can fast mapping like equation based mapping method because of using so-called SZIT(Striping Zone Information Table) and equations. And that method can reduce the relocation overhead in striping system at adding disks.

The method for adding disk with supporting dynamic number of disks in striping system (스트라이핑 시스템에서 동적 디스크 수를 지원하는 계산에 의한 매핑 방법)

  • Bak, Yu-Hyeon;Kim, Chang-Soo;Kim, Young-Ho;Kang, Dong-Jae;Shin, Bum-Joo
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2002.04a
    • /
    • pp.353-356
    • /
    • 2002
  • RAID 레벨 중에서 스트라이핑을 하는 시스템에서는 운영중에 디스크를 추가하려면, 기존의 디스크에 저장되어 있는 데이터들은 새로 추가된 디스크를 고려하여 스트라이핑 하기 위해 재구성하는 과정이 필요하다. 이러한 동적디스크 수의 변화에 유연하게 적응할 수 있도록 매핑 테이블을 사용하는 방법들이 제안되고 있으나 관리해야 할 데이터의 양이 디스크 용량에 비례하여 증가하고 메인 메모리에서 모두 관리할 수 없기 때문에 성능이 떨어지는 문제가 발생한다. 이 논문에서는 스트라이핑을 하는 RAID 시스템에서 적은 양의 메타데이터(SZIT)를 관리함으로써 동적 디스크 수를 지원하는 계산에 의한 매핑 방법을 제안한다.

  • PDF

The performance comparison of Erasure Code to recover from chip units based on SSD (SSD 기반의 칩 단위 복구를 위한 Erasure 코드 성능 비교)

  • Yang, Yu-Seok;Huh, Joon-Moo;Song, Jae-Seok;Kim, Deok-Hwan
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2010.06b
    • /
    • pp.347-351
    • /
    • 2010
  • SSD의 칩을 구성하는 셀의 집적도가 높아지고 시스템 오류가 높아짐에 따라, 저장장치의 고신뢰성을 보장해야 하는 필요성은 점점 증가하고 있다. 현재 SSD 의 오류를 복구하기 위한 방법으로 ECC 가 사용되고 있으나 비트단위의 오류복구만 가능하여 복구 성능의 한계를 가지고 있다. 본 논문에서는 SSD 계층구조인 하나의 칩을 디스크로 설정하고 내부에 RAID 시스템을 구성하여 칩 단위의 오류 복구 기법을 제안한다. 제안된 칩 단위의 오류 복구 기법은 기존 하드디스크 기반 RAID 시스템에 적용 되었던 세 가지 Erasure 코드들을 SSD 에 적용한 방법이다. 또한 실험을 통해 각각의 Erasure 코드 성능을 비교하였다.

  • PDF