• 제목/요약/키워드: 시스템 열펌프

검색결과 422건 처리시간 0.025초

열펌프 시스템의 최적설계 (The Optimum Design of Heat Pump Systems)

  • 배순훈;이상룡
    • 대한설비공학회지:설비저널
    • /
    • 제5권1호
    • /
    • pp.19-24
    • /
    • 1976
  • An ideal heat pump system was optimized by considering the coefficient of performance and the size of condenser and evaporator as two competing objectives. Thermodynamic limitations were included as natural constraints. Experimental data for compressor performance were utilized in evaluating the system behavior. With a varying weighting factor between the two competing objectives the optimum deiogn parameters were presented in a graphical form.

  • PDF

사이클 해석을 통한 GHP 성능 예측 (Prediction of GHP Performance Using Cycle Analysis)

  • 차우호;최송;정백영;김병순;전시문
    • 대한기계학회논문집 C: 기술과 교육
    • /
    • 제3권1호
    • /
    • pp.15-21
    • /
    • 2015
  • 가스 엔진 히트 펌프는 가스 엔진의 축동력으로 압축기를 구동하는 시스템으로 전력을 거의 사용하지 않고, 엔진 폐열을 활용하기 때문에 하절기와 동절기에 전력 Peak 를 억제하는 공조기로 주목을 받고 있는 제품이다. 제품 개발 시 시스템 성능 예측이 중요하므로 이를 위해 초기 설정한 운전점에서 열교환기 및 압축기의 특성을 반영하여 반복 계산을 수행하면 최종적인 운전점을 도출할 수 있고, 가스 엔진의 성능 데이터를 활용하면 가스 엔진 히트 펌프의 정확한 효율을 예측할 수 있다. 난방 성능을 예측할 때에는 엔진 폐열이 시스템에 공급되기 때문에 외부 열을 흡입하는 구간과 엔진 폐열을 흡입하는 구간을 동시에 고려해야 예측의 정확도를 높일 수 있다. 25 마력 가스 엔진 히트 펌프의 성능을 예측한 값은 실제 측정한 값과 비교하였을 경우 5% 정도의 오차가 발생하며 향후 성능 예측 모델을 구성되는 부품 특성을 반영하면 오차의 폭이 감소될 것으로 예상된다.

시설하우스의 폐열을 이용한 열펌프시스템의 성능평가에 관한 연구 (A Study on the Performance Evaluation of Heat Pump System Using Waste Heat in Greenhouse)

  • 조기현;박윤철;고광수
    • 한국태양에너지학회 논문집
    • /
    • 제35권4호
    • /
    • pp.35-41
    • /
    • 2015
  • This study was conducted to develop a heat pump system to utilize waste heat within the greenhouse during the daytime in winter season. The system runs at 8 am to 6 pm for the heat storage operation, and from 6 pm to 8 am of the next day for the heat radiant work. In the case of the heat storage operation, the average solar radiation was $168.3W/m^2$ with $16.3^{\circ}C$ outside temperature. The $COP_s$ of the system shows 4.59 in this operation mode. When the temperature goes up to $18.6^{\circ}C$, the system $COP_s$ reached at 5.10. On the other hand, the $COP_h$ of the system in heat radiation mode shows 2.63. In this case, the inside of the greenhouse temperature was reaches at $24.7^{\circ}C$ when the outside temperature was $12.9^{\circ}C$.

지열히트펌프와 지역냉난방 시스템의 운영사례를 중심으로 경제성 비교분석 연구 (A Study of Comparative Economic Evaluation for the System of Ground Source Heat Pump and District Heating and Cooling:Focusing on the Analysis of Operation Case)

  • 이기창;홍준희;공형진
    • 설비공학논문집
    • /
    • 제28권3호
    • /
    • pp.103-109
    • /
    • 2016
  • The purpose of this study is to perform comparative economic evaluation for the systems of ground source heat pump (GSHP) and district heating and cooling (DHC) by focusing on the analysis of operation case of GSHP. The adapted research object is a public office building located in Seoul. The capacity of ground source pump is about 3,900 kW. Ground heat exchanger is closed loop type. The analysis period for life cycle cost is 30 years. Economic evaluation is assessed from the viewpoints of the following four parts: initial cost, energy cost, maintenance and replacement cost, and environment cost. The total life cycle cost of GSHP is approximately 8,447 million won. The cost of the DHC System is approximately 3,793 million won. The cost of the DHC is approximately 46% lower than GSHP system under the condition of current rate for GSHP and DHC.

고온 초전도 전력케이볼의 냉각시스템 설계에 관한 연구 (A Study on Cooling System Basic Design for HTS Power Cable)

  • 김대웅;양병모;윤형희;강지원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 Techno-Fair 및 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.81-82
    • /
    • 2008
  • 고온초전도 케이블은 초전도 상태를 유지하기 위해서 반드시 액체질소를 이용한 냉각시스템이 필요하다. 액체질소는 순환펌프에 의해 케이블의 유로를 순환하고 케이블을 냉각시키게 된다. 논문에서는 초전도 케이블의 냉각시스템의 기돈 설계에 있어서 중요한 운전온도 운전압력, 열부하에 대해서 고찰하였고, 현재 국내 초전도 케이블의 연구개발에 대해 고찰함으로써 향후 초전도 케이블이 실용화되기 위해 나아가야 할 방향에 대해 제시하였다.

  • PDF

가정용 태양발전 랭킨시스템

  • 한국온돌난방시공협회
    • 보일러설비
    • /
    • 통권71호
    • /
    • pp.59-67
    • /
    • 1999
  • 이 논문에서는 태양발전과 저장을 위한 환경친화적 장치에 대하여 기술하였다. 컴퓨터 모델에 주안점을 두고 시스템의 최적 발전조건을 계산하였는데, 여기에는 작동유체 효율과 태양열 집열판의 크기와 효율 그리고 출력이 포함되어 있다. 영국과 멕시코의 기후조건들이 분석되고, 각 위도에 대한 신뢰 할만한 최근 기상자료가 컴퓨터 수치모사에 사용되었다. 결과를 보면, 연간 출력 4000kW.h를 얻기 위해서, 영국의 경우 시스템 설치에 필요한 집열 면적은 $92m^{\2}$이며, 멕시코의 경우에는 유사 모사조건하에서 동일한 출력을 얻기 위해서는 $48m^{\2}$의 집열면적이 필요하다. 터빈과 이송펌프, 발전기 등의 효율에 민감하여 약간의 효율향상이 있으면 집열 면적을 현저히 감소시킬 수 있다.

  • PDF