• 제목/요약/키워드: 시스템 열펌프

검색결과 422건 처리시간 0.037초

물-공기 지열 멀티형 열펌프 시스템 실증연구 (Verification Experiment of a Water-to-air Ground Source Multi-heat Pump System)

  • 김철우;김병국;이평강;임효재;강신형;최종민
    • 한국지열·수열에너지학회논문집
    • /
    • 제6권1호
    • /
    • pp.9-16
    • /
    • 2010
  • The aim of this study is to verify the performance of water-to-air multi-heat pump system with a vertical U-tube GLHX(U-tube system) and a double tube GLHX(double tube system), which were installed in a school building located in Asan. For analyzing the performance of the GSHP system, we monitored various operating da~ including the water temperature of inlet and outlet of the ground heat exchanger, mass flow rate, and power consumption. Daily average COP of the single U-tube system and the double tube system were 4.5 and 4.2 at cooling mode and were 3.5 and 3.8 at heating mode. As a result, We know that performance of water-to-air multi-heat pump unit is reliable at actual condition operated in a part load conditions for all day.

수중 하베스트형 빙축열시스템의 축열조 특성 실험 (Experiments on the Characteristic of Storage Tank in In-Water Harvest-Type Ice Storage System)

  • 최인수;김재돌;윤정인
    • 에너지공학
    • /
    • 제9권4호
    • /
    • pp.366-371
    • /
    • 2000
  • 본 연구는 동적형 빙축열시스템에 있어서 증발판이 축열조 상부에 설치되어 생성된 얼음을 주기적으로 분리, 이탈시켜 하부에 설치된 축열조에 저장하는 기존의 하베스트형 빙축열시스템과는 반대로 축열조 내에 증발판을 설치하여 수중에서 얼음을 생성시키고 분리시켜 부럭에 의해 얼음을 띄워 저장하는 새로운 방식의 수중 하베스트형 빙축열시스템 개발에 관한 연구이다. 본 방식은 축열조 내에 증발판이 설치되어 제빙과 탈빙이 이루어짐으로서 기존 시스템에 설치되는 순환펌프나 순환수 분배기 및 배관 등의 설비가 불필요하고, 또한 조내 물과 증발판이 직접접촉에 의해 열교환이 이루어지므로 기존 공기 중에서의 열교환 방식보다 전열효율이 우수한 장점을 가지고 있다. 따라서 본 연구에서는 상기의 수중 빙제조 방식에있어 빙 제조시와 방냉시 축열조의 열특성을 실험적으로 밝혀 시스템 최적화 및 성능 향상에 대한 기초 자료를 제공하고자 하였다.

  • PDF

고진공펌프종합특성평가시스템 설계, 진단기술 개발

  • 임종연;정완섭;김완중;남승환;임성규;인상열;홍승수;고득용
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제43회 하계 정기 학술대회 초록집
    • /
    • pp.100-100
    • /
    • 2012
  • 지식경제부의 청정제조기반 산업원천개발사업의 일환으로 진행 중인 "초고진공펌프 개발" 과제 중 제3세부 과제인 "고진공펌프 종합특성평가시스템 설계, 진단기술 개발" 과제에서 진행되고 있는 연구수행결과를 소개한다. 국내 초고진공펌프 개발 수준의 선진화를 위한 기본적인 초석 확립은 현존하는 모든 진공 발생 장치의 국제적 신뢰성이 있는 완벽한 성능평가의 구현에 있다고 할 수 있다. 고진공펌프개발 총괄 과제의 대명제는 "국제적 신뢰성을 가지는 상용화 제품의 완성"이며, 이를 위한 3세부과제의 추진 방향은 기 완료된 1단계 기술개발에 근거한 1세부과제 및 2세부과제와의 유기적인 infra를 통한 성공적인 지원체계 구축 및 상용화 제품 개발 단계의 모든 신뢰성 확보 전략을 수립, 수행하는 것을 골자로 하고 있다. 또한 2단계 사업 추진 동안 제품 개발 주체인 산업체에 모든 개발된 기술을 적용할 수 있는 기반 제공 및 상용화를 위한 성공적인 기술이전도 포함된다. 상용화 개발 완료 후인 Post Project 기간 동안에 발생할 수 있는 모든 지원체계의 구축도 장기간에 걸친 연구 개발의 연장선상에서 추진되어야 될 것으로 예상된다. 세부 추진내용으로 나노팹 공정현장의 고진공펌프 신뢰성평가의 기본 개념설계를 포함한 현장 데이터의 확보 및 분석 현황, 공정현장의 실제 환경에 투입하기 전 단계의 모든 신뢰성 확보 방안, 터보분자펌프의 경우 파괴실험을 포함한 over speed, shock venting, foreign debris dropping test 등 상용화 단계에 필요한 기본 시험평가 조건을 고찰하고자 한다. 상용화 단계의 내구성 및 신뢰성 확보를 위한 전제 조건은 대외적으로 공표할 수 있는 시험 평가 데이터와 개발 주체에서 기밀 수준으로 유지해야만 하는 민감한 자료의 상시 생산 infra의 구축으로 볼 수 있다. 이러한 고진공펌프개발이라는 과제의 대명제를 완성하기 위하여 추진 연구개발 방향 등 진행형인 2년간의 최종 상용화에 필요한 국제 신뢰성, 공정대응성 확보 등 핵심사업 추진내용 및 infra 구축의 상세개발 로드맵을 완성하고자 한다.

  • PDF

단독주택용 지열원 열펌프 시스템의 경제성 분석 (Economic Analysis of a Residential Ground-Source Heat Pump System)

  • 손병후;강신형;임효재
    • 신재생에너지
    • /
    • 제3권4호
    • /
    • pp.31-37
    • /
    • 2007
  • Because of their low operating and maintaining costs, ground-source heat pump(GSHP) systems are an increasingly popular choice for providing heating, cooling and water heating to public and commercial buildings. Despite these advantages and the growing awareness, GSHP systems to residential sectors have not been adopted in Korea until recently. A feasibility study of a residential GSHP system was therefore conducted using the traditional life cycle cost(LCC) analysis within the current electricity price framework and potential scenarios of that framework. As a result, when the current residential electricity costs for running the GSHP system are applied, the GSHP system has weak competitiveness to conventional HV AC systems considered. However, when the operating costs are calculated in the modified price frameworks of electricity, the residential GSHP system has the lower LCC than the existing cooling and heating equipments. The calculation results also show that the residential GSHP system has lower annual prime energy consumption and total pollutant emissions than the alternative HVAC systems considered in this work.

  • PDF

태양열 온수 시스템에 적용한 기포펌프의 동작특성에 관한 연구 (A Study of Bubble Pump that is applied Solar Heating Water System)

  • 박기태;이설송;심규진;정효민;정한식
    • 동력기계공학회지
    • /
    • 제11권4호
    • /
    • pp.32-37
    • /
    • 2007
  • Regarding the need of energy in advance and the depletion of fossil fuel energy, all researches around the world now are trying to extract energy from many alternative sources especially the renewable one. Solar, ocean tidal, wind and geothermal energy are renewable energy fields which many researches are focused on. This paper explains about effort to replace electric pump used in solar water heating system by bubble pump. The utilization of bubble pump in this system is very efficient since it needs heat energy for its operation that can be obtained easily. In addition, it can also simplify the construction of the system. Bubble pump also functions as a controller to circulate water inside the system. Before the installation of bubble pump, the special quality and performance of bubble pump should be analyzed. The result got from the analysis could show the fluctuation of water flow rate occurred because it sensitively reacts to the heat quantity. Here the heat quantity is taken from the solar that, as we know, is not stable in a whole day. Problems often occurred are the flow rate in this system is very low moreover it could be stop if the pressure exceeds the limit.

  • PDF

R744와 R22를 적용한 태양열 하이브리드 열펌프의 성능 시뮬레이션 비교 분석 (Simulation Analysis on Performance Comparison between R744 and R22 Solar Hybrid Heat Pump)

  • 강변;조홍현
    • 한국태양에너지학회 논문집
    • /
    • 제33권2호
    • /
    • pp.1-10
    • /
    • 2013
  • Simulation study of a solar hybrid heat pump using R744 and R22 for residential applications was carried out according to heat pump operating temperature, outdoor temperature and solar radiation. As a result, when the heat pump operating temperature increases from $40^{\circ}C$ to $48^{\circ}C$, the COP of a R744 and R22 heat pump system decrease from 2.15 to 1.7 and from 3.09 to 2.69, respectively. Besides, as the outdoor temperature rises from $3^{\circ}C$ to $11^{\circ}C$, the COP of R744 and R22 heat pump system increase from 1.73 to 2.12 and from 2.73 to 3.02. When the solar radiation increases from 10 to 20 $MJ/m^2$, the collector operating time and collector efficiency of R744 heat pump increase 10.3 times and 50.7%, respectively. The performance of R744 solar hybird heat pump is more sensitive to operation condition compared to that of R22. Besides, the solar heating system is more effective to the R744 heat pump system.

동시냉난방 열펌프 시스템의 운전모드별 성능특성에 관한 수치적 연구 (Numerical Study on the Performance Characteristics of a Simultaneous Heating and Cooling Heat Pump System at each Operation Mode)

  • 주영주;정현준;강훈;최종민;이무연;김용찬
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.370-375
    • /
    • 2007
  • The cooling load in winter season is significant in many commercial buildings and hotels because of the usage of office equipments and high efficiency of wall insulation. The development of a multi-heat pump that can cover heating and cooling simultaneously for each indoor unit is required. In this numerical study, a 4-room simultaneous heating and cooling heat pump system was modeled and its performance was calculated at each operating mode. Also, performance analysis was compared with experimental results.

  • PDF

지열 냉난방 시스템의 성능 및 경제성 평가 (Performance Evaluation and Economic Estimation of Ground Source Heat Pump Cooling and Heating System)

  • 임효재;송윤석;공형진;박성구
    • 에너지공학
    • /
    • 제13권4호
    • /
    • pp.296-300
    • /
    • 2004
  • 본 연구는 지열원 물 대 물(water to water)히트 펌프 시스템의 냉방 및 난방 운전시 성능 특성과 경제성 평가에 관한 것이다. 5개의 보어홀당 지중 100m의 깊이로 밀폐 수직형 지중 열교환기(closed-vertical ground source)가 설치된 냉난방 시스템이 적용된 건축물에 대하여 냉난방 운전성능을 평가하였으며, 연간 소비전력을 측정하여 실제 시스템의 경제성을 분석하였다. 또한, 순환수의 입구온도에 따른 시스템의 운전 성능을 분석한 결과 난방시에는 COP가 3.0에서 4.2로 증가한 반면, 냉방시에는 5.0에서 3.7로 감소하였다. 본 실험을 통해서,대상 건축물에 대한 지열 냉난방 시스템의 수명주기비용은 기존 냉난방 시스템(보일러+에어컨)에 비해서 68%까지 절감되었으며, 시스템의 경제성을 고려해 볼 때 기존 건축물에도 지열원 냉난방 시스템을 적용하는 것이 타당하다.

Research in Transcritical R744 at ACRC, University of lllinose at Urbana-Champaign

  • Bullard, C.;Hrnjak, P.
    • 대한설비공학회지:설비저널
    • /
    • 제31권7호
    • /
    • pp.32-44
    • /
    • 2002
  • 1989년 프레온계 냉매의 대체 가능한 물질로서 $CO_2$재 출연하게 되었고, 그 이후 관련 연구는 점차 증가하였다. 1996년 북미 지역에서 $CO_2$의 연구는 일리노이 대학내 ACRC (Air Conditioning and Refrigeration Center)에서 최대로 시작되었다. 연구비의 90%는 산업체에 의해 지원되었고, 나머지는 미국 정부에 의해 지원되었다. 본 고는 자동차 및 가정용 에어컨 및 열펌프 시스템 및 구성부품 개선에 대한 전반적인 연구활동에 관해 기술하였다. 또한 시스템 성능 비교 결과는 열전달, 압력강하, 사이를 변환,냉매 분해에 대한 연구 지침을 제시하였고, 지속적인 연구 노력을 통하여 천연냉매를 이용하여 간접적인 지구온난화 가스 방출을 최소화하기 위한 시스템 효율을 증가시키고 빈다. $CO_2$의 고유 특징인 초임계 $CO_2$사이클, $CO_2$의 열역학 및 전달 물성치를 통한 효율 개선, 내부 열교환을 통한 사이클 성능 개선방안도 기술되었다.

  • PDF

Vuilleumier열펌프용 재생기 특성 해석 (Analysis on the Regenerator Characteristics for a Vuilleumier Heat Pump)

  • 유호선
    • 대한기계학회논문집
    • /
    • 제17권6호
    • /
    • pp.1572-1583
    • /
    • 1993
  • 본 연구는 VM열펌프를 구성하는 2개 재생기의 특성을 동시에 고려하여 해석하 고자 시도되었다. 먼저, 기존의 유동 및 열전달모델들을 비교, 검토하여 VM열펌프용 재생기 특성에 부합되는 해석모델을 선정한다. 선정된 해석모델을 2차해석법(second -order method)의 개념에 의거, 실제 열펌프에 적용하여 작동조건 및 설계인자에 따른 재생기의 성능변화를 고찰한다. 여기서 2차해석법의 개념은 이상화된 전체시스템에 대한 해석결과로부터 압력, 질량유량 등 필요한 기본변수를 구하여 이들을 재생기특성 해석에 적용하는 접근방법으로서 재생기특성과 작동유체거동 사이의 상호작용은 고려 되지 않는다. 해석과정에서의 구체적인 계산은 각 구성요소에 대한 제원이 비교적 상세히 공개된 Schulz열펌프를 대상으로 수행하며 전술한 기본변수는 이미 발표된 VM사이클에 대한 단열해석법으로부터 구한다.