Comparison for Glomerular Filtration Rate in Gamma Camera Systems Using Dynamic Renal Phantom System (동적신장팬텀시스템 개발에 따른 장비별 사구체여과율의 비교)

  • Kang, Chun Goo;Park, Hoon-Hee;Oh, Shin Hyun;Lee, Han Wool;Kim, Jung Yul;Oh, Joo Yung;Lee, Ju Young;Kim, Jae Sam;Lee, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.3-9
    • /
    • 2013
  • Purpose: Currently commercially available phantom can reproduce and evaluate only a static situation, the study is incomplete research on phantom and system which is can confirmed functional situation in the kidney by time through dynamic phantom and blood flow velocity, various difference according to the amount of radioactive. Therefore, through this study, it has produced the dynamic kidney phantom to reproduce images through the dynamic flow of the kidney, it desire to evaluate the usefulness of nuclear medicine imaging. Materials and Methods: The production of the kidney phantom was fabricated based on the normal adult kidney, in order to reproduce the dynamic situation based on the fabricated kidney phantom, in this study it was applied the volume pump that can adjust the speed of blood flow, so it can be integrated continuously radioactive isotopes in the kidney by using $^{99m}Tc-pertechnate$. Used the radioactive isotope was supplied through the two pump. It was confirmed the changes according to the infusion rate, radioactive isotopes and the different injection speeds on the left and right, analysis of the acquired images was done by drawn ten times ROI in order to check the reproducibility of each on the front and rear of the kidney and bladder. Results: Under the same conditions infusion rate 40 mL/min fixed to adjust the pressure of the pump when the radiopharmaceuticals between 2-3 minutes in the most integrated in the kidney phantom was excreted inthe bladder. Glomerular filtration rate (GFR), respectively, by each device SYMBIA 1,091 mL/min, FORTE 1,232 mL/min, ARGUS 1,264 mL/min, INFINIA 1,302 mL/min in that there isno statistically significant difference was found, Tmax values and T1/2 values stars from all equipment with no statistically significant difference was found. CV values of the coefficient of variation less than 5% was found to be repeatable, and to 2.67% of the lowest SYMBIA appeared, INFINIA was the highest in the 4.86%. Conclusion: Through this study, the results showed that the dynamic kidney phantom system is able to similarly reproduce renogram in the actual clinical. Especially, the depicted over time for the flow to be excreted through the kidney into the bladder was adequately reproduce, it is expected to be utilized as basic data to check the quality of the dynamic images. In addition, it is considered to help in the field of functional imaging and quality control.

  • PDF

Development of Dynamic Kidney Phantom System and its Evaluation of Usability of Application in Nuclear Medicine (핵의학 동적 신장팬텀시스템 개발 적용의 유용성 평가)

  • Park, Hoon-Hee;Lee, Juyoung;Kim, Sang-Wook;Lyu, Kwang Yeul;Jin, Gye Hwan
    • Journal of radiological science and technology
    • /
    • v.36 no.1
    • /
    • pp.49-55
    • /
    • 2013
  • Currently, commercially available phantom can reproduce and evaluate only a static situation, the study is incomplete research on phantom and system which is can confirmed functional situation in the kidney by time through dynamic phantom and blood flow velocity, various difference according to the amount of radioactive. Therefore, through this study, it has produced the dynamic kidney phantom to reproduce images through the dynamic flow of the kidney, it desires to evaluate the usefulness of nuclear medicine imaging. The production of the kidney phantom was fabricated based on the normal adult kidney, in order to reproduce the dynamic situation based on the fabricated kidney phantom, in this study, it was applied the volume pump that can adjust the speed of blood flow, so it can be integrated continuously radioactive isotopes in the kidney by using $^{99m}Tc$-pertechnate. Used the radioactive isotope was supplied through the two pump. It was confirmed the changes according to the infusion rate, radioactive isotopes and the different injection speeds on the left and right, analysis of the acquired images was done by drawn five times ROI in order to check the reproducibility of each on the front and rear of the kidney and bladder. Depending on the speed of injection, radioisotope was a lot of integrated and emissions up when adjusting the pressure of the pump as 30 stroke, it was the least integrated and emissions up when adjusting as 40 stroke. The integration of the left & right kidney was not reached in the amount of the highest when adjusting as 10 stroke. In the changes according to the amount of the radioactive isotope, 0.6 mCi(22.2 MBq), 0.8 mCi (29.6 MBq)was showed up similar tendency but, in the result of the different injection 0.8 mCi, it was showed up counts close to double of 0.6 mCi. In the result of the differently injection speed of the left & right kidney, as a result of different conditions that injection speed was 20 stroke through left kidney phantom, the injection speed was 30 stroke through right kidney phantom, it was enough difference in the resulting image can be easily distinguished with the naked eye. Through this study, the results showed that the dynamic kidney phantom system is able to similarly reproduce renogram in the actual clinical practice. Especially, the depicted over time for the flow to be excreted through the kidney into the bladder was adequately reproduce, it is expected to be utilized as basic data to check the quality of the dynamic images. In addition, it is considered to help in the field of functional imaging and quality control.

Pattern-based Design and Safety Analysis for Networked Supervisory Medical Systems (네트워크 통합형 의료기기를 위한 안전한 상호작용 패턴과 구조적 안전성 검사)

  • Kang, Woochul
    • KIISE Transactions on Computing Practices
    • /
    • v.20 no.10
    • /
    • pp.561-566
    • /
    • 2014
  • There are growing demands for improving the patient safety and the effectiveness of medical services through device connectivity and interoperability. However, integration through networking might greatly increase the complexity of the system if it is not properly designed, jeopardizing patient safety. In this paper, we codify safe medical device interaction patterns, and exploit them for the low complexity design and safety analysis of networked supervisory medical systems. We implement the proposed approach as a plug-in of Architecture Analysis and Description Language (AADL). Our implementation enables the modeling and safety analysis of medical devices and their interactions before actual development.

Design and Implementation of Robot for Updating Automatically Vulnerability Database (취약성 DB 자동 갱신 로봇의 설계 및 구현)

  • 서혜성;최경희;박승규;정기현;이철원;이남훈;한광택
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2002.04a
    • /
    • pp.145-147
    • /
    • 2002
  • 컴퓨터 시스템이나 네트워크의 보안을 강화하는 방안으로 보안상 취약성이 발견되는 보안 취약성을 점검 하는 것이 옳다. 그러나 취약성을 파악하기 위하여 국내외 관련 사이트를 수동적 방법으로 검사하는 것은 대단히 어려운 일이다. 따라서 스스로 관련 사이트의 홈 페이지를 검색하고 취약성 정보를 추출한 후 새로운 취약성 관련 정보가 발견되는 대로 이를 취약성 데이터베이스에 기록하는 이른바 취약성 자동 갱신 시스템[1]은 취약성 탐지 시스템의 핵심 기능이다. 본 논문에서 구현한 취약성 자동 갱신 로봇은 웹 페이지 자동 검색프로그램인 스파이더를 활용하여 구현되었으며, ICAT등과 같은 취약점 정보 제공 사이트들로부터 홈페이지를 검색하고 이에 수록된 정보를 수집 및 분석한 후, 취약성 데이터베이스를 자동으로 갱신한다.

  • PDF

Temporal Active Rules Associated with Event Frequency (사건 빈도와 연합된 시간능동규칙)

  • 박현님;윤종필
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 1998.10b
    • /
    • pp.223-225
    • /
    • 1998
  • 실시간 감시(monitor) 및 제어(control) 시스템의 데이터베이스는 계속적으로 감지기(sensors)에 의해 갱신된다. 연속적인 데이터의 변화에 의한 제약조건(constraints) 위반은 시스템에 심각한 문제를 발생시킨다. 이러한 시스템의 감시 및 제어를 능동적(active)으로 제공하기 위한 기능의 보편적인 형태로 능동규칙(Active rules)을 사용한다. 능동규칙은 정의된 사건(event)이 발생하면, 데이터베이스 상태의 변화에 대한 조건(condition)에 의해 행동(action)을 수행한다. 무결성(integrity) 제약조건을 능동규칙으로 선언함으로써 데이터베이스의 상태를 감시 및 제어하는 것이다. 일반적으로 사용되어온 능동규칙은 제한적인 시간상 무결성 제약조건 검사를 허용하고 있으며, 최근 능동규칙을 사용하여 시간상 연속적인 데이터베이스의 변화에 대한 제약조건 및 트리거(trigger)를 제공하기 위한 연구의 필요성이 대두되고 있다. 이 논문은 사건 빈도와 연합된 시간상에 연속적인 데이터베이스 상태 변화의 확장된 시간조건 상술을 지원하는 시간능동 규칙을 제안한다.

Implementation of Overflow Valve and Performance Evaluation System for Diesel Cars (디젤차량용 오버플로어밸브 및 성능평가 시스템 구현)

  • Yoon, Dal-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.4
    • /
    • pp.1890-1895
    • /
    • 2013
  • In this paper, we have implemented an overflow valve for EURO5 Type and the performance evaluation system based on IT. On injecting a diesel oil into an engine, it is necessity for an overflow valve that can sustain an engine oil status in front of the engine. In order to evaluate the performance of overflow valve, we need the leak test system with IT. The leak test system checks the pressure, switching time and operating time.

Implementation of a test and analysis program for dyslexia (난독증 테스트 및 분석 프로그램 구현)

  • Cho, Sung-Ho;Jee, Sung-Woo;Jung, Hae-Won;Nam, Ki-Chun
    • Proceedings of the KAIS Fall Conference
    • /
    • 2006.05a
    • /
    • pp.474-477
    • /
    • 2006
  • 언어와 인지분야에 관한 연구는 뇌 관련연구 중에 핵심 분야 중의 하나로 뇌의 신경학적 손상으로 언어기능을 상실하는 실어증 및 언어장애에 대한 연구는 매우 중요한 분야이다. 글자를 보고도 읽지 못하는 난독증 환자의 경우 제시되는 그림이나 단어를 얼마나 빠른 시간 안에 반응하는가를 알아내는 것은 치료에 중요한 역할을 한다. 그러나 한국 언어의 특성상 해외의 검사 및 치료도구를 수정 없이 사용하기가 어렵다. 본 논문에서는 난독증 환자를 정확하게 진 단 및 분류할 수 있는 도구를 개발한다. 이러한 시스템 설계에 있어 고려사항을 파악하고 정확한 데이터를 얻기 위해 시스템의 접근사항을 서술한다. 또한, 구현하는 시스템의 발전 방향에 대하여 논한다.

  • PDF

Archieture of Effective Image Data Storage System in PACS (의료영상 시스템에서의 효율적인 이미지 데이터 저장의 설계)

  • Yoo, Seung-Bum;Kim, Min-Su;Kim, Yong-Bin;Shin, Dong-Kyoo;Shin, Dong-Il
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2002.04a
    • /
    • pp.113-116
    • /
    • 2002
  • PACS는 의학용 영상 정보의 저장, 판독 및 검색 기능 등의 수행을 통합적으로 처리하는 시스템을 말한다. 그 중 방사선 검사 곁과를 디지털 이미지로 변환하여 대용량 기억장치에 저장시키는데 기에 따른 저장장치의 비용증가와 데이터의 효율적인 관리가 필요하게 되었다. 따라서 의료 영상 데이터의 효율적인 이동을 위한 이미지 저장 시스템의 모듈을 설계하였다.

  • PDF

LIN Communication Implementation Using the LabVIEW (LabVIEW를 활용한 LIN 통신 구현)

  • Lee, Seung-Ho;Park, Min-Kee
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.538-539
    • /
    • 2013
  • LIN(Local Interconnect Network) 통신은 CAN(Controller Area Network) 통신과 더불어 차량용 통신으로 많이 사용되고 있다. LIN 통신은 필요 성능의 수준이 높지 않은 장치 및 시스템이나 비용의 경제적인 측면에서 CAN 통신의 하부버스로 많이 사용되며 LIN 노드에 개수도 점차 늘어나고 있다. 그렇기 때문에 LIN통신으로 시스템 제어 및 모니터링 프로그램을 GUI(Graphic User Interface)로 제작한다면 시스템 상태의 디스플레이 및 모니터링이 수월해진다. 함수와 GUI로 제작되는 LabVIEW는 다른 텍스트 언어기반 개발 프로그램에 비해 설계 시간 단축 및 사후 관리도 쉽다는 장점이 있다. 본 논문에서는 LabVIEW로 제작한 IBS 모듈 기능 검사 장비개발을 통해 LIN 통신으로 송수신되는 데이터를 확인하고 모니터링, 그리고 설계가 용이하다는 것을 소개하고자 한다.

  • PDF

An Efficient Mobile Agent Recovery Scheme based on Asynchronous Agent Replication (비동기 에이전트 복제를 이용한 효율적인 이동 에이전트 복구 기법)

  • 변일수;강수석;박태순
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2003.04a
    • /
    • pp.157-159
    • /
    • 2003
  • 신뢰할 만한 이동 에이전트 시스템을 구축하기 위해서는 이동 에이전트의 결함 내성 기능이 중요하다. 지금까지 여러 결함 내성 기법이 제안되었는데. 그 중의 하나가 에이전트 복제 기법이다. 에이전트 복제는 검사점 기법에 대해 훨씬 나은 신뢰성을 제공하는 반면, 복제 에이전트의 이동과 동의 과정에 수반되는 부하가 시스템의 성능을 저하시킨다. 그러므로 본 논문에서는 비동기 에이전트 복제 기법을 제안한다. 이 기법에서는 에이전트를 비동기적으로 전송하며 동의 과정을 위해 뒤늦게 전송되는 복제 에이전트를 기다리는 것이 아니라 고정된 동의 전용 에이전트를 사용하여 동의 과정의 비용을 감소시킨다. 제안된 기법은 Aglet 시스템 상에 구현되었으면. 실험 결과 제안된 기법을 사용할 경우 35%-69%의 성능 향상을 얻을 수 있었다.

  • PDF