• Title/Summary/Keyword: 시스템에어컨

Search Result 237, Processing Time 0.024 seconds

Performance Analysis of a Hybrid Desiccant Cooling System for Residential Air Conditioning in the Seoul Region under the Climate Scenarios SSP5 and SSP1 (기후 시나리오 SSP5와 SSP1에서의 2100년 서울 지역에서의 여름철 주택 냉방을 위한 하이브리드 제습 냉방 시스템 성능 분석)

  • YULHO LEE;SUNGJIN PARK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.34 no.6
    • /
    • pp.773-784
    • /
    • 2023
  • In this study, a comparative analysis between an electric heat pump cooling system and a hybrid desiccant cooling system is conducted. Desiccant cooling is a thermal driven system with potentially lower electric power consumption than electric heat pump. Hybrid desiccant cooling system simulation includes components such as a desiccant rotor, direct and indirect evaporative coolers, heat exchangers, fans, and a heat pump system. Using dynamic simulations by climate conditions, house cooling temperatures and power consumption for both systems are analyzed for 16 days period in the summer season under climate scenarios for the year 2100 prediction. The results reveal that the hybrid desiccant cooling system exhibits a 5-18% reduction in electric consumption compared to the heat pump system.

The residential solar air-conditioner using duplex power system (양방향성 전원장치를 이용한 가정용 태양광 에어컨 시스템)

  • Park, Y.J.;Suh, K.Y.;Lee, H.W.;Go, T.E.;Mun, S.P.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1058-1060
    • /
    • 2002
  • This paper to overcome the peak power problems in summer and to endure good AC input characteristics, solar air conditioning system using the PWM converter is proposed and while the proposed circuit uses smaller ones and a small reactor not to boost the output voltage but improve the input current waveform. A high input power factor of 97[%] and an efficiency of 98[%] are also obtained.

  • PDF

Study on the Performance Improvement for an Automobile Air Conditioning System Using Alternative Refrigerant R1234yf (대체냉매 R1234yf를 적용한 자동차용 에어컨 시스템의 성능 향상에 관한 연구)

  • Cho, Honghyun;Lee, Hoseong;Park, Chasik
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.4
    • /
    • pp.201-207
    • /
    • 2013
  • The performance of automobile air conditioning systems of R1234yf was evaluated and compared with that of R134a. In particular, the performance evaluation was carried out by installing an internal heat exchanger in order to improve the performance of the system used in R1234yf. A performance comparison between the R1234yf and R134a for automotive air conditioning revealed that the cooling capacity and COP of the 1234yf system without the IHX decreased by up to 7% and 4.5%, respectively, but those with the IHX decreased by up to 1.8% and 2.9%, respectively.

Protection of the Inverter for Electric Vehicles (전기자동차용 인버터의 보호기능)

  • Jun, Bum-su;Lee, Jae-shin;Kim, Ung-hoe;Kim, Hyoung-taek;Won, Chung-yuen
    • Proceedings of the KIPE Conference
    • /
    • 2011.11a
    • /
    • pp.227-228
    • /
    • 2011
  • EV의 중요한 부품은 MCU(인버터), BMS(고전압), LCD(저전압 충전장치), OBC(완속충전장치), EWP(냉각장치), PTC(히터), A/C(에어컨) 등으로 구성되어 있으며, 특히 EV용 인버터의 경우 핵심 부품으로 신뢰성 및 보호기능에 대한 중요성이 인식되고 있다. EV 인버터는 온도(인버터, 모터), 단락과 단선, 인터락 및 최대출력제한 등에 대한 보호기능 구현이 되어 있으며, 고장발생시 고장을 진단할 수 있는 기능(DTC)이 구현되어 있다. 이러한 보호기능 중에 단락과 단선 시 인버터의 보호는 중요한 요소이며, 이를 구현하기 위한 회로설계 및 회로분석이 필요하다. 본 논문에서는 EV용 인버터에 사용되는 병렬 운전형 인버터의 단락 및 단선 시 시스템을 보호할 수 있는 드라이버 회로 설계 및 분석을 수행하며, 실험을 통해 그 결과를 검증한다.

  • PDF

A Study on the Swash Plate Behavior of Variable Displacement Compressor for Automotive Air Conditioning System (차량용 가변용량 압축기의 사판 거동에 관한 연구)

  • Lee, Tae-Jin;Lee, Geon-Ho
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1335-1340
    • /
    • 2004
  • Due to the distinct advantages of comfort, drive ability and fuel economy standard, the variable displacement swash plate type compressor which can control the compressor displacement by increasing or reducing the swash plate angle has been developed for automotive air-conditioning system. That can be obtained constant temperature of car room on the variation cooling capacities or engine speeds. This paper was carried out the analysis of swash plate behavior to obtain the forces and moments applied to the swash plate and to get the variable controlability on the variation of compressor speeds and swash plate chamber pressures. The results of simuation agree very well with the experimental data.

  • PDF

Source Identification and Reduction of Noise for the Outdoor Unit of Room Air Conditioner (에어컨 실외기의 소음원 규명 및 소음저감)

  • 서상호;임금식;이내영;진심원
    • Journal of KSNVE
    • /
    • v.8 no.6
    • /
    • pp.1043-1052
    • /
    • 1998
  • The noise sources in the outdoor unit of RAC are identified by the sound intensity method. The main noise sources are compressor noise and fluid noise which is caused by the fan. heat exchanger and shroud. First. the fluid noise is reduced through the design of new fan and shroud. reduction of the system resistance by rearrangement of heat exchanger. and optimization of the complex parameter between the fan and shroud. Next, in order to reduce the compressor noise, the new shape of compressor mount and sound-proof material was applied. As a result, the overall noise was reduced by 4∼5dB (A).

  • PDF

자동차 부품 고장 진단에 관한 연구

  • 오재웅;한창수;이호택;신준;모종운;국두윤
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.10a
    • /
    • pp.144-148
    • /
    • 2001
  • 자동차의 발전과 함께 유지 보수를 위한 사용자의 요구는 급증하고 있으나 정비사의 부족으로 인해 경제성 및 신속성 등 이 문제가 되고 있고 이를 해결하기 위해 현재 개발되고 있는 장치들은 대부분 전자 제어 유닛에서 발생시키는 신호를 분석하거나 운전자와의 대화를 통하여 진단하는 방식으로 고장으로 인한 소음이나 진동등 운전자들의 주관적인 평가대상에 대해서는 적절한 해결책으로 제시해 주지 못하고 있다. 그러므로 계측에 의한 소음과 진동 데이터를 이용하여 전문가의 판단을 가지고 고장의 원인을 규명하며 운전자를 위한 오디오적인 표현을 해 줄 수 있는 진단 전문가 시스템이 필요하게 되었다. 본 논문에서는 자동차의 여러 단품중 쇼크 옵서버와 에어컨에 대하여 소음 진동 현상의 정상 및 이상 증상과 신호 계측 방법을 연구하였고 계측된 신호에 대해 패턴 화하여 인공 신경 회로망과 퍼지 추론을 통한 진단을 할 수 있는 알고리즘을 개발하였으며 차후 계속되는 연구에 사용될 정상 및 이상신호에 대한 기본적인 데이터 베이스를 구축하였다.

A Feasibility Study of Educational Calorimeter through Performance Evaluation of Automotive Air-conditioning Heat Exchangers (자동차 에어컨 열교환기 성능평가를 통한 교육용 열량계의 타당성 검토)

  • Song, Jun-Ho;Kang, Kyung-Ho;Lee, Kee-Man
    • Proceedings of the KAIS Fall Conference
    • /
    • 2012.05b
    • /
    • pp.583-586
    • /
    • 2012
  • 현대의 지속적인 기술개발과 산업발전은 삶의 질을 향상시키는 긍정적인 시각이 있는 반면 심각한 환경문제를 안고 있다. 자동차 공조기술도 지구 환경보호라는 거대한 과제와 탑승자의 쾌적성 만족이라는 두 가지 다른 관점을 동시에 충족시켜야 하는 과제를 가지고 있으며, 이 분야 산업에 전문적인 지식으로 공조 열량계 운용에 대한 경험이 대학 교육과정에서도 강조되고 있다. 본 논문에서는 대학 교육과정 특성상 장비의 활용성, 경제성, 장비설치 및 취급의 용이성 등을 고려하여 교육용으로 적합한 간이 열량계를 제작하였다. 교육 및 연구용으로 제작한 간이 열량계의 타당성을 확인하기위해 현재 가장 많이 쓰이고 있는 R134a 자동차용 냉방시스템을 구성하여 압축기 회전속도, 실내 풍량, 냉매 충전량 등을 변수로 하여 열교환기 냉방성능을 평가한 후 비교하여 교육용 열량계의 유용성을 확인하였다.

  • PDF

Commercial Vehicle Anti-Start Air Conditioner Compressor System Using a Power Conversion Unit (전력변환장치를 이용한 상용차용 무시동 에어컨 압축기 시스템)

  • Han, Keun-Woo;Kim, Seong-Gon;Lee, Chung-Hoon;Choi, Myoung-Hyun;Jung, Young-Gook;Lim, Young-Cheol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.6
    • /
    • pp.96-108
    • /
    • 2015
  • his study deals with a power conversion unit of an anti-start air conditioner compressor system for the commercial vehicle. In case of converter, to reduce the switching losses and current stresses of the device, applies LLC resonant topology. Transformer leakage inductance in the full-bridge converter is used for making the resonance with the capacitor of the voltage-doubler. Through this method we can increase power and decrease volume of system. Both circuit analysis and design guideline are described. So in this paper, power conversion unit is designed. 2.5kW anti-start air conditioner compressor system was implemented, and system operation and stability was verified through experiment.

The characteristic analysis of inverter air-conditioner power system with low power dissipation type (저소비전력형 인버터 에어컨 전원시스템의 특성 해석)

  • Park, Young-Jo;Suh, Ki-Young;Mun, Sang-Pil;Kim, Young-Mun
    • Proceedings of the KIEE Conference
    • /
    • 2003.07e
    • /
    • pp.52-54
    • /
    • 2003
  • By having the proposed circuit using a smaller one with a small reactor, the output voltage is boosted-up and improves the input of the current waveform. Therefore, we are able to follow the harmonics guidelines Greater power and efficiency is obtained from the proposed circuit. This also reduces some switching loss and holds the over-shooting by using the inverter of eliminated dead-time HPWM which is a non-linear impedance of the circuit to make up the diodes, the capacitance, and the reactor. We compared the conventional PWM inverter and proposed HPWM inverter.

  • PDF