• Title/Summary/Keyword: 시설용량평가

Search Result 168, Processing Time 0.031 seconds

A Methodology for Analysis of Community Infrastructure Supply Status (지역사회의 생활 인프라 공급현황 분석 방법론)

  • Yhee, Hayeon;Kim, Sungpyo;Kang, Sanghyeok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.3
    • /
    • pp.267-276
    • /
    • 2021
  • Community infrastructure contains national facilities that directly affect the quality of life of citizens. They need to be evenly supplied to every one of citizens. However, the services provided by infrastructure differ by region. In this paper, we propose a method to analyze the current status of the supply of community infrastructure consisting of accessibility and capacity. Accessibility can be evaluated by the time between residence blocks and facilities, which is an indicator of the convenience of citizens. Capacity is assessed by the area supplied for the local population, to assess whether facilities are being sufficiently supplied to the region. The method presented in this paper was applied on a case region to test the applicability. The analysis method of the supply status of community infrastructure in this study is considered to be used as a basic framework for regional supply plan of community infrastructure and urban planning.

Energy Efficiency Evaluation of Publicly Owned Wastewater Utilities (공공하수처리장의 에너지 소비현황 및 효율성 평가)

  • Cho, Eulsaeng;Han, Dae Ho;Ha, Jongsik
    • Journal of Environmental Policy
    • /
    • v.11 no.4
    • /
    • pp.85-105
    • /
    • 2012
  • In this paper, the energy efficiency of wastewater utilities was evaluated to explore ways to save energy via operational measures. The correlation of each wastewater characteristic parameter to energy was assessed to find a set of parameters that explained most of the variations in energy use among utilities. The results show that increases in inflow, influent COD concentration, and ratio of advanced treatment generally increased the energy use. On the other hand, increases in load factor (influentaverage flow/design flow) reduced the energy use. In the regression analysis, the energy efficiency was highest in the A2O advanced process. On the other hand, the membrane process (among the advanced processes) and the contacted aeration process (among the secondary processes) require more efforts in saving energy. However, the data base system related to energy use must be supplemented in order for more accurate analysis of energy consumption in wastewater treatment facilities. In particular, i) electricity consumption of relay pumps and, ii) energy usage per unit process, iii) pump power usage to discharge treated wastewater in a long distance, if necessary, and iv) alternative energy production and utilization status must be recorded. By utilizing the results of the analysis conducted in this study, it is possible to quantify a level of energy savings needed and establish customized energy saving measures to achieve a certain target level for benchmarking a successful case of wastewater utilities.

  • PDF

Development of Optimal Evacuation Model using Civil Defense Evacuation Facilities Survey Data (민방위 대피시설 실태 분석을 통한 최적의 대피모형 개발에 관한 연구)

  • Yeo, Wookhyun;Park, Namhee;Kim, Taewhan;Koo, Wonyong
    • Journal of the Society of Disaster Information
    • /
    • v.8 no.1
    • /
    • pp.71-80
    • /
    • 2012
  • It is necessary to establish guidelines when we selecting the civil defense evacuation facilities through quantitative analysis by civil defense evacuation facilities volume. The purpose of this study is to evaluate according to population density and distribution of the capacity of evacuation facilities. The results of this study are as follows. First, it is necessary to consider the capacity of evacuation facilities in order to set up the exact districts of civil defense evacuation facilities. Second, basic data based on to compare the condition of civil defense evacuation facilities is produced by an analysis on evacuation status of the target region. Third, it is proved to consider topographical conditions which do not move the shortest distance. Fourth, in order to create a realistic model, it is necessary to consider the model set various parameters.

Development of a Water Balance Analysis Tool to Evaluate the Usability of Rainwater Harvesting System (빗물이용시설 활용성 평가를 위한 물수지 분석 도구 개발)

  • Park, Jongpyo;Sim, Inkyeong;Won, Changyeon;Kim, Reeho
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.380-380
    • /
    • 2022
  • 빗물이용시설은 2014년 「물재이용법」 개정에 따라 시설 확충에 맞춘 획일적인 운영으로 시설수는 증가하고 있으나 대상 시설의 이용량 증가에 대한 부분은 한계를 나타내고 있다. 따라서 설치 의무대상시설에 대한 적정한 시설의 이용현황을 조사 및 분석을 통해 이용시설의 효율적인 운영 및 관리 방안 마련이 필요한 실정이다. 빗물이용시설의 효율적 관리방안 설정을 위해서는 의무 대상시설별 설치 및 운영관리 실태조사, 빗물이용시설관련 기준 검토 및 분석, 빗물이용시설 개선방안 마련의 단계로 방안을 수립하여야 한다. 본 연구에서는 빗물이용시설 기준 검토 및 분석에서 지역별, 수요처별, 용도별 일정 빗물이용 활용률을 확보할 수 있는 빗물이용시설의 평가를 위해 수문학적 물수지 분석을 통한 물수요-공급시계열 분석을 수행하였다. 물수지 분석 툴이 없기 때문에 본 연구를 통해 빗물이용시설 물수지 분석 excel 도구를 개발하였으며, 이를 통해 빗물이용시설 공급충족률(필요수량 대비 빗물이용량), 빗물보장률(전체일수 대비 빗물이용일수), 빗물이용시설 이용률(빗물이용시설용량 대비 빗물이용가능량)에 대해 분석을 수행하였다. 개발한 물수지 분석 excel 도구를 이용하여 현재 설치되고 운영하고 있는 의무대상시설의 운영현황과 도구에서 계산된 활용성 평가 결과의 비교를 통해 현재 운영 현황을 개선할 수 있으며, 다양한 시나리오 적용에 따른 운영 결과를 시설 설치 이전에 확인하여 최적 운영방안 도출에 활용할 수 있을 것으로 판단된다.

  • PDF

Analysis of area-based optimal capacity design method in vegetation type LID (식생형 LID 시설에서 면적 기반의 적정 용량 설계 방법 연구)

  • Park, Seowon;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.20 no.4
    • /
    • pp.383-389
    • /
    • 2018
  • Recently, it has been reported that water pollution due to non-point pollutants continues. Studies have been actively carried out to prevent such non-point pollutants from flowing into the water system and to prevent water pollution. In this study, to evaluate the adequate design of the LID facilities the rainfall corresponding to 80% of the cumulative rainfall of Yongin city was applied to an SA / CA graph obtained from the analysis of monitoring results of the vegetation type LID facility. As a result, the appropriate SA/CA ratio was 0.6% for stormwater sustain efficiency 80% and the appropriate SA/CA ratio was 0.5% for TSS removal efficiency 80%. The appropriate SA/CA ratio of the vegetation type LID proposed in this study can be used as a basis. for the future vegetation type LID design. If more data of vegetation type LID are added through continuous research, it will be more accurate.

Study on Design Technique Improvement of Urban Flood Control Facilities considering River and Inland Flood Stage (내외수를 고려한 내배수시설의 설계기술 개선 연구)

  • Kim, Hyung-Jun;Rhee, Dong Sop;Kim, Young Do;Yoon, Sei Eui;Yoon, Byung Man
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.4-4
    • /
    • 2016
  • 기후변화에 따른 강우패턴의 변화로 인하여 도시홍수에 의한 인명 및 재산피해가 증가하여 대응 방안의 마련이 필요한 상황이다. 도시홍수 피해원인을 조사한 기존의 연구결과(심우배, 2008)를 살펴보면, 도시유역에서의 침수피해는 배수능력부족, 하수관거 용량부족 등의 치수시설물의 성능부족이 주원인으로 나타나고 있다. 이와 같은 문제를 해결하기 위해서는 시설물의 설계기술을 향상시켜 치수능력의 증대를 기대할 수 있는 연구성과가 필요하다. 본 연구에서는 내수배제시설의 성능강화를 위하여 내수배제시설 계획수립 기준, 내수배제시설의 성능개선을 위한 정량적 설계지침 개발, 배수시스템의 개선 기법 개발을 수행하였다. 내수배제시설의 계획수립 및 기준 개발을 위하여 침수위험지역 특성에 따른 내배수시설 도입 기준과 내배수시설 설치에 침수위험 저감 효과 분석기법 및 내배수시설 최적 조합을 통한 내수배제능력 평가기법을 개발하였다. 내수배제시설의 성능개선을 위해서는 빗물펌프장 성능 평가 기법과 유입 유출부 및 흡수조 개선 기술, 유출부 주변 부속시설 안정성 향상 기술 개발을 주요 연구내용으로 설정하였다. 마지막으로, 배수시스템의 개선 기법 개발을 위해서는 도시하천 설계빈도 상향에 따른 우수관거 구조개선 기술을 개발하고, 우수관거 시스템 저류능력 평가 기술 및 우수관거 연계 저류시스템 설계 기술개발을 수행하였다. 본 연구에서는 내수배제시설에 대한 정량적 설계기법을 개발하여 도시침수에 대한 구조적인 대응방안을 수립하였다. 시설물 계획단계에서 고려하여야하는 문제점을 연구내용에 반영하여 내수배제시설 설계실무에 실용적으로 적용할 수 있는 성과를 도출하였다. 향후 내수배제시설 설계실무자의 의견을 반영하여 연구성과를 고도화한다면 실무에 적용가능한 성과가 도출될 것으로 기대된다.

  • PDF

성공적인 소아 진정법

  • Baek, Gwang-U
    • 대한치과마취과학회:학술대회논문집
    • /
    • 2005.09a
    • /
    • pp.36-37
    • /
    • 2005
  • 1. 술자가 확실히 수련 받을 때 사용하고, 완전히 익숙해진 약제와 술식만을 사용하여야 한다. 2. 치료의 범위와 종류, 정신적인 필요, 의학적인 상태에 따라서, 필요한 환자에게만 제한적으로 사용하여야 한다. 3. 각 환자의 상태를 술전에 충분히 평가하여야 한다. 4. 치료가 시작해서 끝날 때까지 계속해서 Monitoring을 하여야 한다. 5. 적절한 어린이용 응급약물, 장비, 시설을 갖추고 유지 관리하여야 한다. 6. 사용된 약물의 투여시간, 용량, vital sign, 부작용에 관한 문서화된 기록을 남긴다. 7. 수련 받은 인력을 확보하여야 한다, 8. 위험성이 높은 환자응 병원 혹은 병원급의 시설, 장비가 구비된 곳에서 치료한다.

  • PDF

Estimation on the Design Capacities of Residuals Treatment Facilities by the Quantity of Dewatered Sludge Generated from Water Treatment Plants (정수장에서 발생된 탈수슬러지의 량에 의한 배출수처리시설용량에 대한 평가)

  • Moon, Yong-Taik
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.6
    • /
    • pp.715-723
    • /
    • 2004
  • The quantity of residuals generated from water treatment plants depends upon the raw water quality, dosage of chemicals used, performance of the treatment process, method of sludge removal, efficiency of sedimentation, and backwashing frequency. Sludge production by the physical separation of SS occurs under quiescent conditions in the primary clarifier, where suspended solids are allowed to settle and to consolidate on the clarifier bottom. Raw primary sludge results when the settled solids are hydraulically removed from the tank. The relative solid and liquid fractions of a slurry are most commonly described by the solids concentration, expressed as mg/L or percent solids. The purpose of the present investigation is to estimate a suitability on the design capacities of residuals treatment facilities by the quantity of dewatered sludge generated from water treatment plants.

A Study on the Generation Capacity and Cost Analysis of Solar-Wind Hybrid Power System (태양광-풍력 복합발전시스템의 용량 산정과 경제성 분석에 관한 연구)

  • Kim, Jong-Hwan;Lee, Seung-Chul;Kwon, Byeong-Gook;Oh, Hae-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.348-350
    • /
    • 2003
  • 본 논문에서는 태양광-풍력 복합발전시스템의 발전용량 예측을 통한 시스템 시설투자비 및 발전단가와 경제성에 대하여 분석한다. 도시지역의 일사량 및 풍속 데이터를 기초로 하여 복합발전시스템의 일일 발전량을 구하고, 수용가의 일일부하패턴과 수요부하를 고려하여 태양전지 어레이와 풍력발전기의 용량을 산정한다. 그리고 용량 산정에 따른 복합발전시스템의 초기투자비용과 연간 발전량, 연간 소요경비 등의 요소를 고려하여 총 수명가 분석법(Total Life-Cycle Cost Analysis)에 기초한 발전단가를 계산하고 잉여전력을 계통에 판매할 경우의 경제성을 평가한다.

  • PDF

Green Belt Abolition and Strategic Environmental Assessment: The Case Study of Chongju City (개발제한구역의 해제와 전략환경평가: 청주시를 사례로)

  • Lee, Jong-Ho
    • Journal of Environmental Impact Assessment
    • /
    • v.12 no.3
    • /
    • pp.121-135
    • /
    • 2003
  • 1999년 7월 청주권을 비롯한 7개 지방중소도시권은 친환경적 도시기본계획을 수립한 후 개발제한구역을 해제하도록 하고, 수도권을 비롯한 7개 대도시권은 보전가치가 낮은 지역을 위주로 부분적으로 해제하도록 하였다. 그리하여 표고, 경사도, 농업적성도, 식물상, 임업적성도, 수질 등 6개 항목에 대한 환경평가를 통해 개발제한구역에 용도지역이 지정되었다. 청주시의 경우 환경평가와 주민의견 반영 후 도시계획재정비에 따라 용도지역이 지정되었으나, 평지나 산림생산성이 떨어지는 곳은 낮은 환경등급을 받아 개발이 가능한 용도지역이 지정됨으로써 벨트형 녹지 유지가 어려워져, 시가지 팽창, 대전과 연담화, 도시 허파기능 상실 등의 가능성이 커지게 되었다. 따라서 청주권 개발제한구역의 시가화 영향을 토지피복, 지목, 용도지역 등의 변화를 통해 살펴보고, 6개 항목에 대한 환경평가 과정상 문제점을 고찰한 후, 개발제한구역의 해제 영향을 도시성장측면과 환경용량평가를 통해 규명하고, 전략환경평가의 적용방안을 모색하고자 한다. 전략환경평가의 시행을 위해서는 먼저 오염총량관리제, 국토의 계획 및 이용에 관한 법률에 의한 개발밀도관리구역, 수도권정비계획법에 의한 인구집중시설에 대한 개발총량규제 등이 반영되어야 할 것이다. 그리고 이미 시행중인 개발사업 및 개발계획중인 사업에 대한 누적영향평가와 함께 해당 지역에 대한 환경용량평가가 이뤄져야 하고, 아울러 개발제한구역 해제지역에 대한 사전환경성검토업무편람의 내용을 토대로 하여 환경평가항목에 대한 스코우핑, 환경평가 지표 개발이 이뤄져야 할 것이다.