• Title/Summary/Keyword: 시간-주파수 분석법

Search Result 195, Processing Time 0.029 seconds

Heart Rate Variability and Parenting Stress Index in Children with Attention-Deficit/Hyperactivity Disorder (주의력결핍 과잉행동장애 아동에서의 심박 변이도와 양육 스트레스)

  • Kim, Soo-Young;Lee, Moon-Soo;Yang, Jae-Won;Jung, In-Kwa
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.19 no.2
    • /
    • pp.74-82
    • /
    • 2011
  • Objective:The aim of this study was to evaluate the relationship between sustained attention deficits in Attention-Deficit/Hyperactivity Disorder(ADHD) children and short-term Heart Rate Variability(HRV) parameters. In addition, we evaluate the relationship between The ADHD rating scale(ARS), the computerized ADHD diagnostic system(ADS) and Parenting stress index- short form(PSI-SF). Methods:This study was performed in the department of children and Adolescent psychiatry, Korea university Guro hospital from august 2008 to January 2009. We evaluated HRV parameters by short-term recordings of 5 minutes. K-ARS and ADS are used for screening and identifying ADHD children. Intelligence was measured using Korean educational Developmental Institute-wechsler Intelligence Scale for Children. The caregivers Complete Parenting Stress Index scale for evaluation parent stress. Results:The low frequency(LF) was significantly correlated with response variability of ADS. However, the other variables of ARS and ADS were not significantly correlated with LF. Hyperactivity subscale of ARS was significantly correlated with parental distress subscale and difficult child subscale of PSI-SF and inattention subscale of ARS was also significantly correlated with dysfunctional interaction and difficult child subscale of PSI-SF. Conclusion:The LF, 0.10-Hz component of HRV is known to measure effort allocation. This study shows that the LF component of HRV is significantly correlated with the response variability of ADS. This means that more severe symptoms of ADHD were correlated with the increase in the LF that means decreased effort allocation. These results also support the clinical usability of HRV in the assessment of ADHD. Furthermore, PSI-SF is correlated with hyperactivity and inattention variables of ARS.

  • PDF

Crosshole EM 2.5D Modeling by the Extended Born Approximation (확장된 Born 근사에 의한 시추공간 전자탐사 2.5차원 모델링)

  • Cho, In-Ky;Suh, Jung-Hee
    • Geophysics and Geophysical Exploration
    • /
    • v.1 no.2
    • /
    • pp.127-135
    • /
    • 1998
  • The Born approximation is widely used for solving the complex scattering problems in electromagnetics. Approximating total internal electric field by the background field is reasonable for small material contrasts as long as scatterer is not too large and the frequency is not too high. However in many geophysical applications, moderate and high conductivity contrasts cause both real and imaginary part of internal electric field to differ greatly from background. In the extended Born approximation, which can improve the accuracy of Born approximation dramatically, the total electric field in the integral over the scattering volume is approximated by the background electric field projected to a depolarization tensor. The finite difference and elements methods are usually used in EM scattering problems with a 2D model and a 3D source, due to their capability for simulating complex subsurface conductivity distributions. The price paid for a 3D source is that many wavenumber domain solutions and their inverse Fourier transform must be computed. In these differential equation methods, all the area including homogeneous region should be discretized, which increases the number of nodes and matrix size. Therefore, the differential equation methods need a lot of computing time and large memory. In this study, EM modeling program for a 2D model and a 3D source is developed, which is based on the extended Born approximation. The solution is very fast and stable. Using the program, crosshole EM responses with a vertical magnetic dipole source are obtained and the results are compared with those of 3D integral equation solutions. The agreement between the integral equation solution and extended Born approximation is remarkable within the entire frequency range, but degrades with the increase of conductivity contrast between anomalous body and background medium. The extended Born approximation is accurate in the case conductivity contrast is lower than 1:10. Therefore, the location and conductivity of the anomalous body can be estimated effectively by the extended Born approximation although the quantitative estimate of conductivity is difficult for the case conductivity contrast is too high.

  • PDF

Heart Rate Variability and Autonomic Activity in Patients Affected with Rett Syndrome (Rett 증후군 환자에서의 자율신경 활성도 및 심박수 변이도 측정)

  • Choi, Deok Young;Chang, Jin Ha;Chung, Hee Jung
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.10
    • /
    • pp.996-1002
    • /
    • 2003
  • Purpose : In Rett syndrome patients, the incidence of sudden death is greater than that of the general population, and cardiac electrical instability including fatal cardiac arrhythmia is a main suspected cause. In this study, we are going to find out the possible cause of the higher risk of sudden death in Rett patients by the evaluation of heart rate variability, a marker of cardiac autonomic activity and corrected QT intervals. Methods : Diagnosis of Rett syndrome was made by molecular genetic study of Rett syndrome (MECP2 gene) or clinical diagnostic criteria of Rett syndrome. Heart rate variability and corrected QT intervals were measured by 24 h-Holter study in 12 Rett patients, and in 30 age-matched healthy children with chief complaints of chest pain or suspected heart murmurs. The were compared with the normal age-matched control. Results : Patients with total Rett syndrome, classic Rett syndrome, and Rett variants had significantly lower heart rate variability(especially rMSSD)(P<0.05) and longer corrected QT intervals than age-matched healthy children(P<0.05). Sympathovagal balance expressed by the ratio of high to low frequency(LF/HF ratio) also showed statistically significant differences between the three groups considered(P<0.05). Conclusion : A significant reduction of heart rate variability, a marker of autonomic disarray, suggests a possible explanation of cardiac dysfunction in sudden death associated with Rett syndrome.

Electrochemical Evaluation of Cadmium and Lead by Thiolated Carbon Nanotube Electrodes (티올화된 탄소나노튜브 전극을 이용한 카드뮴과 납의 전기화학적 분석)

  • Yang, Jongwon;Kim, Lae-Hyun;Kwon, Yongchai
    • Applied Chemistry for Engineering
    • /
    • v.24 no.5
    • /
    • pp.551-557
    • /
    • 2013
  • In the present study, pristine carbon nanotube (p-CNT) and thiolated carbon naotube (t-CNT) electrodes were investigated to improve their detectabilities for cadmium (Cd) and lead (Pb). In addition, we evaluate which reaction mechanism is used when the electrolyte contains both Cd and Pb metals. Square wave stripping was employed for analyzing the sensitivity for the metals. A frequency of 30 Hz, a deposition potential of -1.2 V vs. Ag/AgCl and a deposition time of 300 s were used as optimal SWSV parameters. t-CNT electrodes show the better sensitivity for both Cd and Pb metals than that of p-CNT electrodes. In case of Cd, sensitivities of p-CNT and t-CNT electrodes were $3.1{\mu}A/{\mu}M$ and $4.6{\mu}A/{\mu}M$, respectively, while the sensitivities for Pb were $6.5{\mu}A/{\mu}M$ (p-CNT) and $9.9{\mu}A/{\mu}M$ (t-CNT), respectively. The better sensitivity of p-CNT electrodes is due to the enhancement in the reaction rate of metal ions that are facilitated by thiol groups attached on the surface of CNT. When sensitivity was measured for the detection of Cd and Pb metals present simultaneously in the electrolyte, Pb indicates better sensitivity than Cd irrespective of electrode types. It is ascribed to the low standard electrode potential of Pb, which then promotes the possibility of oxidation reaction of the Pb metal ions. In turn, the Pb metal ions are deposited on the electrode surface faster than that of Cd metal ions and cover the electrode surface during deposition step, and thus Pb metals that cover the large portion of the surface are more easily stripped than that of Cd metals during stripping step.

The Change of Heart Rate Variability in Anxiety Disorder after Given Physical or Psychological Stress (불안장애 환자에서 육체적 및 정신적 스트레스 시 심박변이도의 변화)

  • Cho, Min-Kyung;Park, Doo-Heum;Yu, Jaehak;Ryu, Seung-Ho;Ha, Ji-Hyeon
    • Sleep Medicine and Psychophysiology
    • /
    • v.21 no.2
    • /
    • pp.69-73
    • /
    • 2014
  • Objectives: This study was designed to assess the change of heart rate variability (HRV) at resting, upright, and psychological stress in anxiety disorder patients. Methods: HRV was measured at resting, upright, and psychological stress states in 60 anxiety disorder patients. We used visual analogue scale (VAS) score to assess tension and stress severity. Beck depression inventory (BDI) and state trait anxiety inventories I and II (STAI-I and II) were used to assess depression and anxiety severity. Differences between HRV indices were evaluated using paired t-tests. Gender difference analysis was accomplished with ANCOVA. Results: SDNN (Standard deviation of normal RR intervals) and low frequency/high frequency (LF/HF) were significantly increased, while NN50, pNN50, and normalized HF (nHF) were significantly decreased in the upright position compared to resting state (p < 0.01). SDNN, root mean square of the differences of successive normal to normal intervals, and LF/HF were significantly increased, while nHF was significantly decreased in the psychological stress state compared to resting state (p < 0.01). SDNN, NN50, pNN50 were significantly lower in upright position compared to psychological stress and nVLF, nLF, nHF, and LF/HF showed no significant differences between them. Conclusion: The LF/HF ratio was significantly increased after both physical and psychological stress in anxiety disorder, but did not show a significant difference between these two stresses. Significant differences of SDNN, NN50, and pNN50 without any differences of nVLF, nLF, nHF, and LF/HF between two stresses might suggest that frequency domain analysis is more specific than time domain analysis.