• Title/Summary/Keyword: 시간의존계수

Search Result 151, Processing Time 0.021 seconds

Analysis for Effect of Diffusion Parameter with Time-dependent Diffusion Coefficient on Service Life Considering Deterministic and Probabilistic Method (시간의존성 염화물 확산계수를 고려한 확산 영향인자가 결정론적 및 확률론적 내구수명에 미치는 영향분석)

  • Kwon, Seung-Jun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.3
    • /
    • pp.259-268
    • /
    • 2016
  • The service life evaluation in RC(Reinforced Concrete) structure exposed to chloride attack can be classified into deterministic and probabilistic method, and it significantly varies with design parameters. The present work derives PDF (Probability of Durability Failure) and the related service life considering time-dependent diffusion coefficient and internal parameters such as reference diffusion coefficient, critical chloride content, and time-exponent. When critical chloride content increases to 133.3%, the changing ratios of service life are 134.0~145.4% for deterministic method and 149.2%~152.5% for probabilistic method, respectively. In the case of increasing time-exponent to 200%, they increase to 323.8% for deterministic method and 346.0% for probabilistic method. Through adopting time-diffusion coefficient for probabilistic method, reasonable service life evaluation can be achieved, and it is also verified that increasing time-exponent through mineral admixture is very effective to extension of service life in RC structure.

Analysis Technique for Chloride Penetration using Double-layer and Time-Dependent Chloride Diffusion in Concrete (콘크리트내의 이중구조와 시간의존성을 고려한 염화물 해석기법의 개발)

  • Mun, Jin-Man;Kim, Jin-Yeong;Kim, Young-Joon;Oh, Gyeong-Seok;Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.5
    • /
    • pp.83-91
    • /
    • 2015
  • With varying conditions of concrete surface, induced chloride contents are changed and this is a key parameter for steel corrosion and service life in RC (Reinforced Concrete) structures. Many surface enhancement techniques using impregnation have been developed, however the evaluation techniques for chloride behavior through doubly layered media and time-dependent diffusion are rarely proposed. This paper presents an analysis technique considering double-layer concrete and time-dependent diffusion behavior, and the results are compared with those from the previous test results through reverse analysis. The chloride profiles from the surface-impregnated concrete exposed to atmospheric, tidal, submerged zone for 2 years are adopted. Furthermore surface chloride contents and diffusion coefficients are obtained, and are compared with those from Life365. Through consideration of time effect, the relative error decreases from 0.28 to 0.20 in atmospheric, 0.29 to 0.11 in tidal, and 0.54 to 0.40 in submerged zone, respectively, which shows more reasonable results. Utilizing the diffusion coefficients from Life365, relative errors increases and it needs deeper penetration depth (e) and lower diffusion coefficient ratio ($D_1/D_2$) due to higher diffusion coefficient.

Evaluation of Chloride Diffusion Characteristics in Concrete with Fly Ash Cured for 2 Years (2년 양생된 Fly Ash 콘크리트의 염화물 확산 특성 평가)

  • Yoon, Yong-Sik;Hwang, Sang-Hyeon;Kwon, Seung-Jun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.7 no.1
    • /
    • pp.8-15
    • /
    • 2019
  • When RC(Reinforced Concrete) structures are exposed to harsh environment, deterioration phenomenon occurs, and the corrosion in rebar due to chloride intrusion is known as representative deterioration, so called chloride attack. In this paper, chloride resistance performance of 2 years aged concrete is evaluated considering 3 levels of water to binder ratio(0.37, 0.42, and 0.47) and 2 levels of substitution ratio of fly ash(0% and 30%). Accelerated chloride diffusion coefficient tests referred to Tang's method, total passed charge tests referred to ASTM C 1202, and compressive strength tests referred to KS F 2405 are performed. With adaptation of the previous test results and the results from this study, time-dependent chloride diffusion characteristics are analyzed for each concrete. The FA(Fly Ash) concrete has higher chloride resistance performance than OPC(Ordinary Portland Cement) concrete. According to the evaluation standard of ASTM C 1202, the FA concrete has "Moderate" grade after 49 days while OPC concrete does "Moderate" grade after 365 days. As the results of time-parameter for chloride diffusion, OPC concrete and FA concrete show the decreasing behavior of time-parameters with increasing water to binder ratio. Also, FA concrete has 1.57~2.74 times of time-parameter than OPC concrete. That's cause is thought that the time-parameter indicates the gradient of decreasing of diffusion coefficient. FA concrete has higher time-parameters than OPC concrete by pozzolanic reaction of FA.

Analysis Technique for Chloride Penetration in High Performance Concrete Behavior Considering Time-Dependent Accelerated Chloride Diffusivity (촉진염화물 확산계수의 시간의존성을 고려한 고성능 콘크리트의 염화물 침투 해석기법)

  • Kwon, Seung-Jun;Park, Sun-Gyu
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.2
    • /
    • pp.145-153
    • /
    • 2013
  • Recently, accelerated chloride diffusion coefficients are used for an evaluation of chloride behavior. Similar as apparent diffusion coefficients, accelerated diffusion coefficients decrease with time. In this study, decrease in diffusion coefficient with time is simulated with porosity. Utilizing DUCOM-program, porosities from 15 mix proportions are obtained and diffusion coefficients are modelled with regression analysis of porosity for 270 days. Considering non-linear binding capacity which means the relation between free and bound chloride ion, chloride behavior in high performance concrete is evaluated. Through utilizing the previous test results for concrete under chlorides for 180 days, the applicability of the proposed technique is verified. The proposed technique is evaluated to reasonably predict the chloride behavior in concrete with various w/c (water to cement) ratios and mineral admixtures (GGBFS and FA). It is also shown that decrease in chloride diffusion should be considered for chloride prediction in concrete with mineral admixture since it has very clear decrease in diffusivity with time.

Evaluation of Time-Dependent Chloride Resistance in HPC Containing Fly Ash Cured for 1 Year (1년 양생 조건의 Fly Ash를 혼입한 고성능 콘크리트의 시간의존적 염해저항성 평가)

  • Yoon, Yong-Sik;Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.4
    • /
    • pp.52-59
    • /
    • 2018
  • To control chloride attacks which is a representative deterioration in RC(Reinforced Concrete) structures, many studies have been conducted. Above all, a method using mineral admixture was known to be effective for corrosion protection. In this study, durability test about chloride attacks was carried out for concrete specimens containing FA(Fly Ash)-representative concrete mineral admixture and OPC concrete specimens considering 3 different levels of W/B(Water to Binder). Accelerated chloride diffusion coefficient tests referred to Tang's method, total passed charge tests referred to ASTM C 1202, and compressive strength tests based on KS F 2405 were performed at each target age day. Also, based on previous studies of 28 days, time-parameter which is a key parameter for diffusion behavior is evaluated and its relations with compressive strength at the age of 365 days is evaluated. After the age of 49 days, chloride resistance of FA concrete is much improved than that of OPC concrete, which arose out of stable hydrates due to pozzolan reaction of fly ash. Time-parameter of FA concrete is evaluated to be about 1.5 times larger than that of OPC concrete. Also, time-parameter of FA concrete has a linearly decreasing relation while that of OPC concrete has a linearly increasing relation with compressive strength development.

The Microwave Dielectric Properties of Sintering Condition of ZST Ceramics for Movile Telecommunication System (이동 통신용 ZST세라믹스의 소결조건에 따른 고주파 유전 특성)

  • Seo, Jung-Chull;Lee, Hee-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05b
    • /
    • pp.257-260
    • /
    • 2000
  • 소결온도 및 소결시간의 변화가 ZST세라믹의 유전상수 $\varepsilon_{\tau}$, 품질계수 $Q{\cdot}f$ 및 공진주파수의 온도계수 $\tau_f$에 미치는 영향에 대하여 연구하였다. 소결온도를 $1420^{\circ}C$까지 올렸을 때 공진기 섭동방법으로 1.6GHz에서 측정한 품질계수 Q가 가장 높았으나, 소결밀도 및 유전상수는 오히려 감소하였다. 소결시간의 증가에 따른 품질계수 Q는 $1300^{\circ}C{\sim}1380^{\circ}C$ 온도 범위에서는 소폭 상승하였으며, 소결밀도 및 유전상수는 거의 일정하였다. 공진주파수의 온도계수 $\tau_f$는 소결온도 및 소결시간의 변화에는 거의 의존하지 않았다.

  • PDF

The Effects of Stress and Time History on Pore Pressure Parameter of Overconsoldated clay (과압밀점토의 간극수압계수에 응력이력과 시간이력이 미치는 영향)

  • 김수삼;김병일;한상재;신현영
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.14 no.4
    • /
    • pp.286-294
    • /
    • 2002
  • This study investigated the effects of stress and time history of overconsolidated clayey soils on pore pressure parameter, A. Laboratory tests were carried out under the conditions of both varying stress and time history. The stress history is classified into (i) rotation angle of stress path, (ii) overconsolidation ratio, and (iii) magnitude of length of recent stress path. The time history is divided into (i) loading rate of recent stress path and (ii) rest time. Pore pressure parameters are different both in the magnitude and trend with the rotation angle, depending on the magnitude of overconsolidation ratio but not in a trend. In addition, the pore pressure parameters have no effects on the magnitude of length of recent stress path except the level of initially small strain, while loading rates of recent stress path have effects on it. Finally, the pore pressure parameters of overconsolidated clays increase with the existence of the rest time, until either the deviator stress exceeds 70 kPa or the strain up to 0.1%.

Analysis Technique on Time-dependent PDF (Probability of Durability Failure) Considering Equivalent Surface Chloride Content (균등 표면 염화물량을 고려한 시간 의존적 내구적 파괴확률 해석기법)

  • Lee, Hack-Soo;Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.2
    • /
    • pp.46-52
    • /
    • 2017
  • Recently durability design based on deterministic or probabilistic method has been attempted since service life evaluation in RC(Reinforced Concrete) structure exposed to chloride attack is important. The deterministic durability design contains a reasonable method with time effect on surface chloride content and diffusion coefficient, however the probabilistic design procedure has no consideration of time effect on both. In the paper, a technique on PDF(Probability of Durability Failure) evaluation is proposed considering time effect on diffusion and surface chloride content through equivalent surface chloride content which has same induced chloride content within a given period and cover depth. With varying period to built-up from 10 to 30 years and maximum surface chloride content from $5.0kg/m^3$ to $10.0kg/m^3$, the changing PDF and the related service life are derived. The proposed method can be reasonably applied to actual durability design with preventing conservative design parameters and considering the same analysis conditions of the deterministic method.

Estimation of error factors in concrete cable-stayed bridge considering creep (크리프를 고려한 콘크리트 사장교의 오차 요인 추정)

  • Park, Jong-Bum;Cho, Jae-Yeol;Park, Jung-Il;Chang, Sung-Pil
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.387-388
    • /
    • 2009
  • In concrete cable-stayed bridge, the time-dependent effects of concrete should be taken into account for the optimum cable force adjustment. The method for estimating the creep coefficient with using the deflections and the cable forces in concrete cable-stayed bridge is presented and the effects of the creep coefficient error are analyzed.

  • PDF