• Title/Summary/Keyword: 시간간격신호

Search Result 240, Processing Time 0.035 seconds

A Comparison on the Positioning Accuracy from Different Filtering Strategies in IMU/Ranging System (IMU/Range 시스템의 필터링기법별 위치정확도 비교 연구)

  • Kwon, Jay-Hyoun;Lee, Jong-Ki
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.26 no.3
    • /
    • pp.263-273
    • /
    • 2008
  • The precision of sensors' position is particularly important in the application of road extraction or digital map generation. In general, the various ranging solution systems such as GPS, Total Station, and Laser Ranger have been employed for the position of the sensor. Basically, the ranging solution system has problems that the signal may be blocked or degraded by various environmental circumstances and has low temporal resolution. To overcome those limitations a IMU/range integrated system could be introduced. In this paper, after pointing out the limitation of extended Kalman filter which has been used for workhorse in navigation and geodetic community, the two sampling based nonlinear filters which are sigma point Kalman filter using nonlinear transformation and carefully chosen sigma points and particle filter using the non-gaussian assumption are implemented and compared with extended Kalman filter in a simulation test. For the ranging solution system, the GPS and Total station was selected and the three levels of IMUs(IMU400C, HG1700, LN100) are chosen for the simulation. For all ranging solution system and IMUs the sampling based nonlinear filter yield improved position result and it is more noticeable that the superiority of nonlinear filter in low temporal resolution such as 5 sec. Therefore, it is recommended to apply non-linear filter to determine the sensor's position with low degree position sensors.

A study on digital locking device design using detection distance 13.4mm of human body sensing type magnetic field coil (인체 감지형 자기장 코일의 감지거리 13.4mm를 이용한 디지털 잠금장치 설계에 관한 연구)

  • Lee, In-Sang;Song, Je-Ho;Bang, Jun-Ho;Lee, You-Yub
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.1
    • /
    • pp.9-14
    • /
    • 2016
  • This study evaluated a digital locking device design using detection distance of 13.4mm of a human body sensing type magnetic field coil. In contrast to digital locking devices that are used nowadays, the existing serial number entering buttons, lighting, number cover, corresponding pcb, exterior case, and data delivery cables have been deleted and are only composed of control ON/OFF power switches and emergency terminals. When the magnetic field coil substrates installed inside the inner case detects the electric resistance delivered from the opposite side of the 12mm interval exterior contacting the glass body part, the corresponding induced current flows. At this time, the magnetic field coil takes the role as a sensor when coil frequency of the circular coil is transformed. The magnetic coil as a sensor detects a change in the oscillation frequency output before and after the body is detected. This is then amplified to larger than 2,000%, transformed into digital signals, and delivered to exclusive software to compare and search for embedded data. The detection time followed by the touch area of the body standard to a $12.8{\emptyset}$ magnetic field coil was 30% contrast at 0.08sec and 80% contrast at 0.03sec, in which the detection distance was 13.4mm, showing the best level.

Trace-based Interpolation Using Machine Learning for Irregularly Missing Seismic Data (불규칙한 빠짐을 포함한 탄성파 탐사 자료의 머신러닝을 이용한 트레이스 기반 내삽)

  • Zeu Yeeh;Jiho Park;Soon Jee Seol;Daeung Yoon;Joongmoo Byun
    • Geophysics and Geophysical Exploration
    • /
    • v.26 no.2
    • /
    • pp.62-76
    • /
    • 2023
  • Recently, machine learning (ML) techniques have been actively applied for seismic trace interpolation. However, because most research is based on training-inference strategies that treat missing trace gather data as a 2D image with a blank area, a sufficient number of fully sampled data are required for training. This study proposes trace interpolation using ML, which uses only irregularly sampled field data, both in training and inference, by modifying the training-inference strategies of trace-based interpolation techniques. In this study, we describe a method for constructing networks that vary depending on the maximum number of consecutive gaps in seismic field data and the training method. To verify the applicability of the proposed method to field data, we applied our method to time-migrated seismic data acquired from the Vincent oilfield in the Exmouth Sub-basin area of Western Australia and compared the results with those of the conventional trace interpolation method. Both methods showed high interpolation performance, as confirmed by quantitative indicators, and the interpolation performance was uniformly good at all frequencies.

Cell-type Specific Activation of MAPKs in the Progression of Gastric Ulcer in Rats (위궤양의 진행에 있어 MAPKs의 세포특이적 활성)

  • Yu, Ri;Kwon, Young Sam;Oh, Tae-Ho;Kim, Tae-Hwan;Park, Sang-Joon
    • Journal of Veterinary Clinics
    • /
    • v.30 no.5
    • /
    • pp.339-345
    • /
    • 2013
  • Mitogen-activated protein kinases (MAPKs) are a family of central signaling molecules that respond to numerous stimuli and are known to participate in processes of cell survival and death. However, it is not clear on data for cell-type specific activation of MAPKs in the progression of gastric ulcer. In the present study, we assessed how MAPKs localized at various cell types during the progression of gastric ulcer induced by ibuprofen. Gastric ulcer was induced by the repeated treatment of 200 mg/kg ibuprofen with 8 hrs interval in a day. Animals were sacrificed at 24 hrs, 48 hrs, and 72 hrs after oral treatment of ibuprofen and gastric tissues were subjected to immunohistochemical and immunoblotting evaluation. Immunoreactivity of phospho-extracellular signal-regulated kinase (p-ERK) was mainly expressed at the proliferating zone of gastric mucosa in control rats. But, these signals for p-ERK were highly shifted from cells of proliferating zone to parietal cells of the basal regions 24 hrs after treatment of ibuprofen. p-ERK signal was strongly expressed in epithelial cells adjacent to ulcer margin and new capillary and infiltrated inflammatory cells within granulation tissue of the ulcer base above 48 hrs after treatment of ibuprofen. While, phospho-c-Jun $NH_2$ terminal kinase (p-JNK) was mainly localized to the nuclei of the surface epithelial cells and the glandular epithelial cells in early gastric injury. Also, p-JNK was often observed as a scattered pattern in different regions of gastric mucosa with early gastric injury. Gradually, signal of p-JNK was strongly stained in infiltrated inflammatory cells and fibroblasts within severe ulcer base. Phospho-p38 (p-p38) MAPK was observed as scattered pattern within connective tissues of gastric mucosa. Especially, p-p38 MAPK showed strong signal in infiltrated macrophages within ulcer base. These results show that each MAPK has a specific role in various cell types during the progression of gastric ulcer.

Internal Waves and Surface Mixing Observed by CTD and Echo Sounder in the mid-eastern Yellow Sea (황해 중동부해역에서 CTD와 음향탐지기로 관측한 내부파와 표층 혼합)

  • Lee, Sang-Ho;Choi, Byoung-Ju;Jeong, Woo Jin
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.18 no.1
    • /
    • pp.1-12
    • /
    • 2013
  • Acoustic backscatter profiles were measured by Eco-sounder along an east-west section in the mid-eastern Yellow Sea and at an anchoring station in the low salinity region off the Keum River estuary in September 2012, with observing physical water property structure by CTD. Tidal front was established around the sand ridge developed in 50 m depth region. Internal waves measured by Eco-sounder during low tide period in the eastern side of the sand ridge were nonlinear depression waves with wave height of 15 m and mean wavelength of 500 m. These waves were interpreted into tidal internal waves that were produced by tidal current flowing over the sand ridge to the southeast. When weakly non-linear soliton model was applied, propagation speed and period of these internal depression wave were 50 m/s and 16~18 min. Red tides by Dinoflagelates Cochlodinium were observed in the sea surface where strong acoustic scattering layer was raised up to 7 m. Hourly CTD profiles taken at the anchoring station off the Keum River estuary showed the halocline depth change by tidal current and land-sea breeze. When tidal current flowed strongly to the northeast during flood period and land-breeze of 7 m/s blew to the west, the halocline was temporally raised up as much as 2 m and acoustic profile images showed a complex structure in the surface layer within 5-m depth: in tens of seconds the declined acoustic structure of strong and weak scattering signals alternatively appeared with entrainment and intrusion shape. These acoustic profile structures in the surface mixed layer were observed for the first time in the coastal sea of the mid-eastern Yellow Sea. The acoustic profile images and turbidity data suggest that relatively transparent low-layer water be intruded or entrained into the turbid upper-layer water by vertical shear between flood current and land breeze-induced surface current.

Electrical Stimulation Parameters in Normal and Degenerate Rabbit Retina (정상 망막과 변성 망막을 위한 전기자극 파라미터)

  • Jin, Gye-Hwan;Goo, Yong-Sook
    • Progress in Medical Physics
    • /
    • v.19 no.1
    • /
    • pp.73-79
    • /
    • 2008
  • Retinal prosthesis is regarded as the most feasible method for the blind caused by retinal diseases such as retinitis pigmentosa (RP) or age related macular degeneration (AMD). Recently Korean consortium launched for developing retinal prosthesis. One of the prerequisites for the success of retinal prosthesis is the optimization of the electrical stimuli applied through the prosthesis. Since electrical characteristics of degenerate retina are expected to differ from those of normal retina, we performed voltage stimulation experiment both in normal and degenerate retina to provide a guideline for the optimization of electrical stimulation for the upcoming prosthesis. After isolation of retina, retinal patch was attached with the ganglion cell side facing the surface of microelectrode arrays (MEA). $8{\times}8$ grid layout MEA (electrode diameter: $30{\mu}m$, electrode spacing: $200{\mu}m$, and impedance: $50k{\Omega}$ at 1 kHz) was used to record in-vitro retinal ganglion cell activity. Mono-polar electrical stimulation was applied through one of the 60 MEA channel, and the remaining channels were used for recording. The electrical stimulus was a constant voltage, charge-balanced biphasic, anodic-first square wave pulse without interphase delay, and 50 trains of pulse was applied with a period of 2 sec. Different electrical stimuli were applied. First, pulse amplitude was varied (voltage: $0.5{\sim}3.0V$). Second, pulse duration was varied $(100{\sim}1,200{\mu}s)$. Evoked responses were analyzed by PSTH from averaged data with 50 trials. Charge density was calculated with Ohm's and Coulomb's law. In normal retina, by varying the pulse amplitude from 0.5 to 3V with fixed duration of $500{\mu}s$, the threshold level for reliable ganglion cell response was found at 1.5V. The calculated threshold of charge density was $2.123mC/cm^2$. By varying the pulse duration from 100 to $1,200{\mu}s$ with fixed amplitude of 2V, the threshold level was found at $300{\mu}s$. The calculated threhold of charge density was $1.698mC/cm^2$. Even after the block of ON-pathway with L-(1)-2-amino-4-phosphonobutyric acid (APB), electrical stimulus evoked ganglion cell activities. In this APB-induced degenerate retina, by varying the pulse duration from 100 to $1200{\mu}s$ with fixed voltage of 2 V, the threshold level was found at $300{\mu}s$, which is the same with normal retina. More experiment with APB-induced degenerate retina is needed to make a clear comparison of threshold of charge density between normal and degenerate retina.

  • PDF

The Analysis of Expression of Autoinducer Synthesis Genes Involved in Quorum Sensing among Catheter Associated Bacteria (요로감염에 관여하는 카테터 내 박테리아의 Quorum Sensing 관련 autoinducer 합성 유전자의 발현분석)

  • Lee, Mi-Hye;Seo, Pil-Soo;Lee, Ji-Youl;Peck, Kyong-Ran;Lee, Sang-Seob
    • Korean Journal of Microbiology
    • /
    • v.42 no.4
    • /
    • pp.277-285
    • /
    • 2006
  • The most biofilm forming bacteria in catheter, Esctherichia coli, Pseudomonas aeruginosa, and Staphylococcus aureus were isolated and identified from a patient's catheter occuring catheter-associated urinary tract infection (CA-UTI). We examined mRNA expression and its quantification of AIs synthetic genes encoding signal substance of quorum sensing from each bacterial species in order to elucidated quorum sensing mechanism. Both pure cultures for each bacterial strains and a mixed cultures with three were grown for 24 hr and 30 days. Initial densities to be able to detect mRNA expression oil single strains culture were shown at $2.4{\times}10^5$ CFU/ml, $5.4{\times}10^6$ CFU/ml of E. coli for ygaG and S. aureus for luxS, and at $6.9{\times}10^4$ CFU/ml of P. aeruginosa for rhlI and lasI. Also, in mixed culture of three, initial cell densities of mRNA expression were appear to at $7.3{\times}10^5$ CFU/ml, $1.6{\times}10^7$ CFU/ml of E. coli for ygaG and S. aureus for luxS, and at $2.1{\times}10^5$ CFU/ml of P. aeruginosa for rhlI and lasI. Each AIs synthetic gene was expressed in initial cell density and the mRNA expression of the genes were detected continously during 30 days. And then, the quantification of mRNA expression level of ygaG, rhlI, last, and luxS which were related AIs synthesis was done each time point by real-time RT-PCR. Interestingly, the mRNA levels of ygaG, rhlI, lasI, and luxS from the mixed culture was higher than those from each single strain culture. In the case of E. coli ygaG, the amount of transcript from the mixed culture was at least 30 times for that from single culture. In the case of P. aeruginosa rhlI and lasI, the amount of transcript from the mixed culture was at least 40 times and 250 times for that from single strain culture. In the case of S. aureus luxS, the amount of transcript from the mixed culture was at least 5 times for that from single strain culture. And specially, the mRNA expression of rhlI and lasI of P. aeruginosa showed the highest efficency among four AIs synthetic genes.

A Study on the Accuracy of the Loran-C Fix of Korean Chain in Pusan Area (부산지역에서의 Loran-C 한국체인의 측위정도에 관한 연구)

  • 박주삼
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.32 no.4
    • /
    • pp.372-380
    • /
    • 1996
  • The operation of Far East Chain(GRI 5970) of Loran - C system had been stopped on June, 1995, but that of Korean Chain(GRI 9930) of Loran - C system which was jointed with North West Pacific Chain(GRI 8930) and Russia Chain(GRI 7950) by international cooperation, was started on January 1996. In this paper, in order to study the accuracy of Loran - C fix of Korean Chain, the authors examined and analyzed the data of the reciever of Loran - C(LC -90, Furuno) and GPS(AccNav Sport super (TM), Eagle) measured automatically and continually for 2 seconds at interval of 5 minutes from November 22, 1992, to January 20, 1996 at the fixed position of National Fisheries University of Pusan, The results obtained were as follows ; 1)The mean time differences of M-W, M-X, and M-Y pair measured in the base observed position were 12333.09${\mu}$s, 28338.44${\mu}$s, and 42806.01${\mu}$s respectively and the mean standard deviations of that were 0.0121${\mu}$s, 0.0290${\mu}$s, and 0.0327${\mu}$s respectively. The daily and monthly variance forms of time difference at each pair appeared in a similar reappearance. 2)The mean standard deviations of the latitude and longitude by Loran - C were 9.1m and 17.4m in W.X pair, 11.5m and 13.7m in W.Y pair, and 8.1m and 29.3m in X.Y pair respectively, and then the probable radiuses within 95% of each pair were 39.2m, 35.7m, and 60.8m, respectively. Therefore, It is to be desired that W.Y par is selected to improve the accuracy in Pusan area. 3)The mean standard deviations of the latitude and longitude by GPS were 15.4m and 15.0m and the probable radius within 95% was 43.4m. 4)The position errors for GPS and each pair of Loran - C were 16.0m to the South in GPS and 265.2m to the East in W.X pair of Loran - C, 279.5m to the North in W.Y pair of that, and 224.3m to the North-West in X.Y pair of that, so GPS is about 250m higher than Loran - C in accuracy.

  • PDF

Effects of Secondary Task on Driving Performance -Control of Vehicle and Analysis of Motion signal- (동시과제가 운전 수행 능력에 미치는 영향 -차량 통제 및 동작신호 해석을 중심으로-)

  • Mun, Kyung-Ryoul;Choi, Jin-Seung;Kang, Dong-Won;Bang, Yun-Hwan;Kim, Han-Soo;Lee, Su-Jung;Yang, Jae-Woong;Kim, Ji-Hye;Choi, Mi-Hyun;Ji, Doo-Hwan;Min, Byung-Chan;Chung, Soon-Cheol;Taek, Gye-Rae
    • Science of Emotion and Sensibility
    • /
    • v.13 no.4
    • /
    • pp.613-620
    • /
    • 2010
  • The purpose of this study was to quantitatively evaluate the effects of the secondary task while simulated driving using the variable indicating control of vehicle and smoothness of motion. Fifteen healthy adults having 1~2years driving experience were participated. 9 markers were attached on the subjects' upper(shoulder, elbow, Wrist) and lower(knee, ankle, toe) limbs and all subjects were instructed to keep the 30m distance with the front vehicle running at 80km/hr speed. Sending text message(STM) and searching navigation(SN) were selected as the secondary task. Experiment consisted of driving alone for 1 min and driving with secondary task for 1 min, and was defined driving and cognition blocks respectively. To indicate the effects of secondary task, coefficient of variation of distance between vehicles and lane keeping(APCV and MLCV) and jerk-cost function(JC) were analyzed. APCV was increased by 222.1% in SN block. MLCV was increased by 318.2% in STM and 308.4% in SN. JC were increased at the drivers' elbow, knee, ankle and toe, especially the total mean JC of lower limbs were increased by 218.2% in STM and 294.7% in SN. Conclusively, Performing secondary tasks while driving decreased the smoothness of motion with increased JC and disturbed the control of vehicle with increased APCV and MLCV.

  • PDF

The Role of c-Jun N-terminal Kinase in the Radiation-Induced Lung Fibrosis (방사선에 의한 폐 섬유화증에서 c-Jun N-terminal Kinase(JNK)의 역할)

  • Uh, Soo-Taek;Hong, Ki-Young;Lee, Young-Mok;Kim, Ki-Up;Kim, Do-Jin;Moon, Seung-Hyuk;Kim, Yong-Hoon;Park, Choon-Sik;Yeom, Uk;Kim, Eun-Suk;Choi, Doo-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.50 no.4
    • /
    • pp.450-461
    • /
    • 2001
  • Background : The underlying pathogenesis of radiation-induced lung fibrosis (RTLF) has not been very well defined. However, the role of TGF-$\beta$ in the generation of RTLF has been a major focus because there is an increase in the expression of both the TGF-${\beta}m$-RNA and its protein preceding RTLF lesions. The down stream signal after a TGF-$\beta$ stimulated lung fibrosis includes the activation of many mediators such as Smad and c-Jun N-terminal kinase (JNK) through TAK1. It is we hypothesized that JNK activation may play a pivotal role in RTLF pathogenesis through increased transcription of the fibrogenic cytokines. The present study evaluates JNK activity in alveolar macrophages after irradiation and the relationship between JNK activity and the amount of collagen in the lung tissues. Methods : C57BL/6 mice(20-25 gr, males) received chlorotetracycline(2g/L) in their drinking water 1 week prior to irradiation and continuously there after. The mice were irradiated once with 1400 cGy of $60CO{\gamma}$-ray over the whole chest. The cellular composition of the whole lung bronchoalveoalr lavage fluids(BALF), elastin expression in the lung tissues, the level of hydroxyproline in lung tissues, and an in vitro JNK assay was measured before irradiation and one, four, and eight weeks after irradiation (RT). Results : The volumes of BALF retrieved from instilled 4 mL of saline with 2% heparin were 3.7-3.8 mL for each group. The cell numbers were similar before($4.1{\times}10^4{\pm}0.5{\times}10^4/mL$) and 1 week($3.1{\times}10^4{\pm}0.5{\times}10^4/mL$) after RT. At four and eight weeks after RT, the cell number reached to $14.0{\times}10^4{\pm}1.5{\times}10^4mL$ and $10.0{\times}10^4{\pm}1.3{\times}10^4/mL$, respectively. There we no changes in the lymphocytes and neutrophils population observed in the BALF after RT. The H-E stain of the lung tissues did not show any structural and fibrotic change in the lung tissues at 4 and 8 weeks after RT. In addition, the amount of elastin and collagen were not different on Verhoeff staining of the lung tissues before RT to eight weeks after RT. The hydroxyproine content was measured with the left lung dissected from the left main bronchus. The lung were homogenized and hydrolyzed with 6 N Hel for 12 hours at $110^{\circ}C$ then measured as previously described. The content of hydroxyproline, standardized with a lung protein concentration, reached a peak 4 weeks after RT, and thereafter showed a plateau. AnIn vitro JNK assay using c-$Jun_{1-79}$-GST sepharose beads were performed with the alveolar macrophages obtained from the BAL. JNK activity was not detected prior to RT, However, the JNK activity increased from one week after RT and reached a peak four weeks after RT. Conclusion : JNK may be involved in the pathogenesis because the JNK activity showed similar pattern observed with the hydroxyproine content. However, it is necessary to clarify that the JNK increases the transcription of fibrogenic cyiokines through the transcription factor.

  • PDF