• Title/Summary/Keyword: 습도센터

Search Result 38, Processing Time 0.022 seconds

Bridge Road Surface Frost Prediction and Monitoring System (교량구간의 결빙 예측 및 감지 시스템)

  • Sin, Geon-Hun;Song, Young-Jun;You, Young-Gap
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.11
    • /
    • pp.42-48
    • /
    • 2011
  • This paper presents a bridge road surface frost prediction and monitoring system. The node sensing hardware comprises microprocessor, temperature sensors, humidity sensors and Zigbee wireless communication. A software interface is implemented the control center to monitor and acquire the temperature and humidity data of bridge road surface. A bridge road surface frost occurs when the bridge deck temperature drops below the dew point and the freezing point. Measurement data was used for prediction of road surface frost occurrences. The actual alert is performed at least 30 minutes in advance the road surface frost. The road surface frost occurrences data are sent to nearby drivers for traffic accidents prevention purposes.

Astronomical seeing analysis of Deokheung Optical Astronomy Observatory

  • Kim, Taewoo;Kang, Wonseok;Kwon, Sun-gill;Lee, Sang-Gak
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.2
    • /
    • pp.59.2-59.2
    • /
    • 2015
  • 국립고흥청소년우주체험센터는 2014년부터 덕흥천문대에 설치된 SBIG사의 "Seeing Monitor"로 시상을 측정하고 있다. "Seeing Monitor"는 북극성을 대상으로 TDI(Time Delay and Integration) 방식을 적용하여 얻어진 시상을 분 단위로 저장해준다. 따라서 구름이 없는 맑은 날의 분 단위 시상 자료와 주변 환경 정보를 조합하여 시상에 영향을 미치는지 환경 요인을 정량적으로 분석하는 것이 가능하다. 그 첫 단계로 측정된 시상 자료와 기상청의 온도 습도 풍속 자료, 그리고 GFS(Global Forecast System)의 고도별 상층 풍속 자료를 비교하여 기상정보와 시상과의 관계를 분석해보았다. 습도와 바람이 시상에 가장 큰 영향을 주었으며, 지상 풍속 1~2m/s, 습도 75% 이하, 제트기류 풍속은 250km/h 이하 일 때 좋은 시상 값을 얻을 수 있었다. 이를 통해 덕흥천문대에서 기상정보를 통해 시상이 안정적인 날을 예측할 수 있다면, 앞으로 도입될 1m 망원경으로 훌륭한 관측 자료를 얻을 수 있을 것이라 기대된다.

  • PDF

Rack Power Solutions for Green Data Centers (그린 데이터센터를 위한 랙전원 솔루션)

  • Kwon, W.O.;Kim, S.W.
    • Electronics and Telecommunications Trends
    • /
    • v.24 no.4
    • /
    • pp.126-134
    • /
    • 2009
  • 기존의 AC 전력전달 기반의 데이터센터를 고효율의 DC 데이터센터로 변경에 관한 연구가 활발히 진행중이다. 그 중 랙 준위 DC 전원공급장치는 기존 데이터센터의 전력구조 변화 없이 랙 레벨에서 DC 전원을 서버에 공급하는 방식으로 기존 AC 데이터센터에 적용 가능한 최적의 기술이다. 본 논문은 ETRI가 개발한 데이터센터의 랙 준위 DC 전원공급장치 특징에 관한 내용을 담고 있다. 본 장치는 부하에 따라 효율을 최적으로 제어하는 지능적 제어 기법을 사용하며, 랙 준위 N+ 1 전력 이중화로 높은 안정성을 제공하고 있다. 또한 랙 준위 전력 및 랙 주위 온/습도정보의 실시간 웹 모니터링 기능을 제공하고 있다.

Design of Interface Specification for Smart Buoys in Maritime Environment (해상 환경에 적합한 스마트 항로표지용 인터페이스 규격 설계)

  • Junsu Kim;Yangseop Kim;Sungyoon Cho;Donghyun Kim;Kiwon Kwon
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2023.11a
    • /
    • pp.180-181
    • /
    • 2023
  • 본 논문은 해양 환경에서 항로표지 내에 탑재되는 등명기, 배터리, BMS, 통신장치 등의 전원 공급 및 각 모듈들 간의 유선 데이터 통신에 사용할 수 있는 커넥터 인터페이스 규격을 제시한다. 제안하는 규격은 M12 커넥터 규격을 이용하여 내구성을 확보하고 방수방진을 지원한다. 이를 통해 극한의 온·습도에 노출되며 태풍, 파도 등의 변수가 많은 해양 환경에서의 안정적인 연결성 유지를 기대할 수 있다.

  • PDF

Investigation of the shift trends of temperature and humidity in greenhouses for oak mushroom cultivation (최근 국내 표고 재배사의 온도, 습도 변화 성향 조사)

  • Kim, Ji Eun;Kim, Jun Young;Ahn, Hong Seok;Kown, Hyuk Woo;Ko, Han Gyu;Kim, Seong Hwan
    • Journal of Mushroom
    • /
    • v.16 no.4
    • /
    • pp.342-346
    • /
    • 2018
  • The temperature and humidity of 49 greenhouses for oak mushroom cultivation were investigated for 5 years to analyze the trends in the change of these parameters according to the climate change in Korea. The 5-year average temperature and humidity were $24.7^{\circ}C$ and 60.5%, respectively, in sawdust media-based cultivation houses and $24.4^{\circ}C$ and 60.0%, respectively, in log-bed cultivation houses. The average temperature in the summer was $29.8^{\circ}C$ in 2016, $29.1^{\circ}C$ in 2017, and $33.3^{\circ}C$ in 2018 in the log-bed cultivation houses and $26.8^{\circ}C$ in 2016, $20.4^{\circ}C$ in 2017, and $24.2^{\circ}C$ in 2018 in the sawdust media-based cultivation houses. During the investigation, temperatures over $30^{\circ}C$ were detected in one cultivation house in spring and five such houses in summer. When classifying by cultivation type, temperatures over $30^{\circ}C$ were found in five log-bed cultivation houses and temperatures less than $20^{\circ}C$ were found in four log-bed cultivation houses in fall. This study shows that log-bed cultivation houses for oak mushroom need to be modified to cope with the climate change.

Photovoltaic Generation System Design for Controlling the Temperature and Humidity of Hospital (병원내 온도와 습도조절을 위한 태양광 발전 시스템 설계)

  • Cho, Moon-Taek;Lee, Chung-Sik;Baek, Jong-Mu
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.3
    • /
    • pp.127-134
    • /
    • 2011
  • In this paper we propose an improved PV generation systems. Improved systems for temperature and humidity controlled heating and air conditioning offers a pleasant environment within the building, set up chopper and consists of a PWM voltage type inverter. The proposed system is stable modulation for a one-chip microprocessor using the synchronous signal and control signals was treated. The proposed system is a PWM voltage type inverter and phase of the synchronous to the grid voltage to detect the system voltage and inverter output to drive the statue, so surplus power to connection was able to, certain buildings such as buildings or hospitals, temperature and humidity sensor is applied to the good dynamic characteristic could be obtained. In addition, the system was applied to the high power factor and low-frequency harmonics by maintaining the output load and grid to power to be supplied to a stable control could get a good result.

Air-conditioning design for industrial large space (산업용 대공간에 대한 공조계획)

  • 윤원석
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.28 no.1
    • /
    • pp.25-30
    • /
    • 1999
  • 최근 고도의 경제성장과 함께 유통구조의 선진화로 대형화, 하역 및 적재, 운반기계의 자동화를 도입하므로써 생산 또는 보관제품의 품질 보존, 작업 인원의 최소화 및 교통체중에 대한 적절한 대응으로 고품격의 물류 서비스를 할 수 있게 되었다. 특히, 생산 또는 보관제품의 품질 보존을 위해서는 물류 창고 내의 물류 특성에 따른 실내 공조환경 즉, 적정한 온 습도 및 기류를 유지하도록 공조설비를 계획하여야 하는데 층고가 높고 바닥면적이 넓은 대형 물류센터 즉, 산업용 대공간에 대한 공조설비는 층고 높이로 적재된 장애물을 극복하고 취출되는 기류가 실내 전체에 골고루 확산 및 순환 될 수 있도록 적정한 공조방식을 선정하여야 한다. 따라서 본 계획에서는 주로 N-스포츠사의 이천 물류센터 공조방식의 설계 사례를 들어 산업용 대공간에 대한 공조계획 개선 방안을 소개 하고자 한다.

  • PDF

Theory of Temperature & Humidity Control for Air Condition (공기환경 온·습도제어의 이론적 고찰)

  • Lee, W.Y.
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.11 no.1
    • /
    • pp.183-195
    • /
    • 2009
  • 시설하우스의 공기환경은 작물생육에 큰 영향을 준다. 특히 기공주변 공기의 상대습도는 증산작용에 크게 영향을 주며, 안개가 끼게 되면 기공을 통한 증산작용이 일어나지 않아 작물은 생육을 멈추게 된다. 이에 대한 이론적 고찰을 습공기선도를 중심으로 살펴보았으며, 그 기술을 권왕림(경기도 이천시 백사면 모전2리 192) 쌈채소 재배 농장과 정기설(경기도 용인시 백암면 석천리) 백암육계 농장에 적용한 결과를 요약하면 다음과 같다. 1. 여름철 온실 공기의 온도를 낮추기 위하여 널리 사용하는 Pad & Fan, Mist & Fan 등의 증발냉각 방법은 사막 기후지역(온도는 높고 습도는 낮은 지역)에 적합한 방법으로 우리나라와 같이 고온 다습한 기후에는 적합하지 않다. 2. 겨울철 저녁에 온실을 보온하기 전에 따뜻한 공기의 열이 연료비를 절감 할 수 있다는 생각으로 환기를 하지 않으면 절대습도가 높아 약간의 온도가 떨어져도 안개가 발생하게 된다. 3. 겨울철 저녁에 온실을 보온하기 전에 외부 공기로 충분히 환기하여 절대습도를 낮추면 노점온도가 낮아지고, 약간의 난방으로도 온실의 안개를 방지할 수 있다. 4. 여름철 상추재배에서 시원한 바람으로 공기환경을 개선한 결과 41.6%의 증수효과가 있었다. 5. 겨울철 육계농장의 공기환경 개선으로 47,300수 기준으로 폐사율 2%와 난방연료 40%를 절감할 수 있었으며, 육계 성장의 균일도를 53%→73%로 20%정도 높일 수 있었다. ※ 정기설 백암육계 농장(경기도 용인시 백암면 석천리) (011-719-7597)

Enhancing Medium-Range Forecast Accuracy of Temperature and Relative Humidity over South Korea using Minimum Continuous Ranked Probability Score (CRPS) Statistical Correction Technique (연속 순위 확률 점수를 활용한 통합 앙상블 모델에 대한 기온 및 습도 후처리 모델 개발)

  • Hyejeong Bok;Junsu Kim;Yeon-Hee Kim;Eunju Cho;Seungbum Kim
    • Atmosphere
    • /
    • v.34 no.1
    • /
    • pp.23-34
    • /
    • 2024
  • The Korea Meteorological Administration has improved medium-range weather forecasts by implementing post-processing methods to minimize numerical model errors. In this study, we employ a statistical correction technique known as the minimum continuous ranked probability score (CRPS) to refine medium-range forecast guidance. This technique quantifies the similarity between the predicted values and the observed cumulative distribution function of the Unified Model Ensemble Prediction System for Global (UM EPSG). We evaluated the performance of the medium-range forecast guidance for surface air temperature and relative humidity, noting significant enhancements in seasonal bias and root mean squared error compared to observations. Notably, compared to the existing the medium-range forecast guidance, temperature forecasts exhibit 17.5% improvement in summer and 21.5% improvement in winter. Humidity forecasts also show 12% improvement in summer and 23% improvement in winter. The results indicate that utilizing the minimum CRPS for medium-range forecast guidance provide more reliable and improved performance than UM EPSG.

The Construction and Performance Test of Complex Networks based on Ubiquitous (유비쿼터스 기반의 복합통신망 구축 및 성능시험)

  • Hong, Sung-Taek;Shin, Gang-Wook
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.11 no.4
    • /
    • pp.23-29
    • /
    • 2011
  • We try to build the base for implementation of smart water treatment plant through identifying status by data acquisition such as temperature, humidity, flow, level, pump status and CCTV by using USN terminal such as Zigbee, Wi-Fi, UHF at the center of the flowmeter calibration center in K-water institute. The data obtained from various sensors is transmitted to data processing device through different types of USN network, the processed data is implemented to monitor by smart phone and we try to perform low cost and high efficient USN-based pilot project by implementing remote monitoring system using network performance analysis and mobile devices.